Fancom AURA 37 User manual

g

N.B.: The original, authentic version of this manual is the English version produced by Fancom B.V. or one of its
daughter companies (referred to further as Fancom). Any modifications introduced to this manual by third parties
have neither been checked nor approved by Fancom. Modifications are taken by Fancom to include translations
into languages other than English and the insertion and/or deletion of text and/or illustrations to/from the original
contents. Fancom cannot be held liable for any damages, injury, guarantee claims and other claims relating to this
type of modification, in as far as these modifications result in a content that differs from the original English
version of this manual produced by Fancom. For the latest information about product installation and operation,
please contact the customer service dept. and/or the technical service dept. of the Fancom concerned. In spite of
the care taken when compiling this manual, if you should discover any errors, please inform Fancom B.V. in
writing. Fancom B.V., PO Box 7131, 5980 AC Panningen (the Netherlands).
Copyright © 2017 Fancom B.V.
Panningen (the Netherlands)
All rights reserved. Nothing from this manual may be copied, distributed or translated into other languages, partly
or wholly, without express prior written permission from Fancom. Fancom reserves the right to modify this manual
without notice. Fancom can give no guarantee, neither implicit nor explicit, for this manual. All risks are for the
user.
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V.
Art.Nr. 5911975
GB180104

Aura 37
Table of contents
i
1. General introduction .................................................................................................................................. 1
1.1 Documentation with the control computer....................................................................................... 1
1.2 How to use this manual .................................................................................................................. 1
1.3 Fancom Sales & Service Center..................................................................................................... 1
1.4 Safety instructions and warnings.................................................................................................... 2
2. Aura 37 ........................................................................................................................................................ 3
3. Using the Aura 37....................................................................................................................................... 4
3.1 Main parts....................................................................................................................................... 4
3.2 Switching on the Aura 37................................................................................................................ 4
3.3 Working with the Aura 37................................................................................................................ 5
4. User settings............................................................................................................................................... 6
4.1 Overview screen............................................................................................................................. 6
4.2 Setting the curves........................................................................................................................... 9
4.3 Min-max........................................................................................................................................ 11
4.4 Registration .................................................................................................................................. 11
4.5 Output status................................................................................................................................ 12
5. Alarm ......................................................................................................................................................... 13
5.1 Alarm overview............................................................................................................................. 13
5.2 Alarm settings............................................................................................................................... 16
5.3 Alarm history................................................................................................................................. 17
6. Installing the Aura 37 ............................................................................................................................... 18
6.1 Determine location........................................................................................................................ 18
6.2 Mount the Aura 37........................................................................................................................ 18
6.3 Connect the Aura 37..................................................................................................................... 19
6.4 Connect the Aura 37 to FNet........................................................................................................ 20
7. Installer settings....................................................................................................................................... 21
7.1 CFG.............................................................................................................................................. 21
7.2 SYS .............................................................................................................................................. 22
7.3 INF................................................................................................................................................ 23
7.4 IN.................................................................................................................................................. 24
7.5 OUT.............................................................................................................................................. 25
7.6 CMB ............................................................................................................................................. 27
8. Appendix: Connection diagram Aura 37 ................................................................................................ 28
9. Appendix: Connection diagram for alarm .............................................................................................. 29
9.1 Single alarm-unit........................................................................................................................... 29
9.2 Multiple alarm-units ...................................................................................................................... 29
10. Technical specifications .......................................................................................................................... 30
10.1 Interior control computer............................................................................................................... 31
10.2 Powerboard RC-REL13................................................................................................................ 31
10.3 Aura board.................................................................................................................................... 32
11. Appendix: EG-declaration of compliance............................................................................................... 33

Aura 37
General introduction
1
This manual has been created with the utmost care. If, however, you should discover an error, please inform
Fancom B.V..
This manual supplies information about connecting and configuring the control computer and information about
working with the control computer after installation. Always keep the manual close to the control computer.
For more information about the principles of climate management see the Fancom climate handbook.
The following symbols are used in this manual:
Tips and suggestions.
Note providing recommendations and additional information.
Warning indicating damage to the product if you do not follow procedures carefully.
Warning indicating danger to humans or animals.
Electrical shock hazard. Danger to humans and animals.
Example of a practical application of the described functionality.
Calculation example.
Describes the key combinations for arriving at a particular screen.
Decimals
The control computer and this manual use a decimal point in values. For example: a weight is shown as 1.5 kg
(not as 1,5 kg).
For any questions and support, please contact the local Fancom Sales & Service Center.

Aura 37
General introduction
2
Before installing and commissioning the Aura 37, read the safety instructions, provisions and conditions carefully.
This paragraph contains a number of general safety instructions. The installation of the device and remedying of
any malfunctions should be performed by a certified electrical installer according to the applicable norms. The
guarantee does not apply if this product is installed in any other way than is indicated by Fancom and changes
have been made to the product.
Disconnect power before installation or before carrying out any maintenance to the control computer.
You must be able to switch off the device using a bipolar main switch.
Take precautions against electrostatic discharge (ESD) when working on the control computer. Ensure
the workplace is clean and dry.
Use the wiring/cables indicated on the connection diagrams and follow all. Only apply power after the
wiring has been connected correctly. Incorrect connections can cause permanent damage. Before a
new fuse is placed, the cause of the defect should be remedied by an authorized installer. Only replace
a defective fuse by a fuse of the same type (see connection diagram).
Inspect the control computer regularly for any damage. Report any damage to your installer
immediately. A damaged control computer is dangerous! Do not use running water (high pressure
cleaners) to clean your control computer. The control computer is water resistant, but not waterproof!
Do not switch off the computer when houses are unoccupied; otherwise there is the risk of
condensation in the computer.
The installation, of which this product is a part, must be equipped with a reliable, independent alarm
system, for example, a minimum/maximum thermostat. We advise you to test the alarm system every
day for proper functioning.
Connect each Fancom device according to the applicable legislation/regulations of the local energy
provider.
Check that the mains voltage and frequency, for which this computer is suitable, correspond to the
mains voltage and frequency on site.
Low-voltage and high-voltage wires may not be placed parallel to each other but may cross each other.
When using metal ducts, Fancom advises grounding the ducts at the ends and at as many other places
as possible.
Connect the computers to one group, from the main distributor.
Keep signal and power cables as short as possible.

Aura 37
Aura 37
3
The Aura 37 is a control designed for mechanically ventilated poultry houses with a constant (non-growing
animals) or an increasing ventilation demand (growing animals). The Aura 37 has the following features:
Ventilation temperature control based on setpoint house
Ventilation influences on high and low outside temperature
Ventilation influenced on relative humidity
Ventilation settable using a combi control matrix
Ventilation fan control using analog output
Ventilation sidewall and tunnel inlet using analog output
Ventilation settings in %
Ventilation linear or modulation control
Ventilation by adding eight additional fan outputs
Temperature measurement for two house sensors
Temperature measurement for outside sensor
Relative humidity measurement
Curve settings on day number for set temperature, set relative humidity, min vent and max vent
Heating output for one heater
Cool output for one cooling
Humidification output
Registration of water, feed and one auxiliary registration
Limited history of water, feed and auxiliary registration
Alarming on temperature, RH and power fail

Aura 37
Using the Aura 37
4
This chapter describes the main parts and the operation of the Aura 37.
The Aura 37 can be operated on the touch screen.
1. Touch screen
The controller is automatically activated as soon as you switch on the power. The start-up progress is shown on
the screen.

Aura 37
Using the Aura 37
5
The Aura 37 screens are divided in three sections:
1. Title bar: Displays the name of the control computer, daynumber and date and time field. The button in the
right corner can be used to switch between user and installer views.
2. Working area: Displays the data of user or installation settings of the control computer.
3. Menu selection and alarm bar: Provides buttons to navigate through available menus (e.g. curve) and an
alarm indicator to navigate to more details.
In the Aura 37 the Setpoint house temperature and Start ventilation temperature are equal. In this
manual both are used.

Aura 37
User settings
6
The Aura 37 displays the Overview screen by default. This screen provides the temperature, ventilation and
relative humidity dials.
Temperature dial
Readout of the temperature values (°C/°F) in the section.
1. Lower boundary of the comfort zone
2. Actual measured temperature
3. Actual measured temperature
4. Upper boundary of the comfort zone
Ventilation dial
1. Minimum ventilation
2. Actual calculated ventilation
3. Calculated ventilation
4. Maximum ventilation
Humidity dial
1. Minimum relative humidity
2. Actual measured relative humidity
3. Actual measured relative humidity
4. Maximum relative humidity
Readout of the heating status (Yellow ON / Grey OFF).
Readout of the cooling status (Blue ON / Grey OFF).

Aura 37
User settings
7
Readout of the ventilation status (8 combi fans) (Blue ON / Grey OFF).
Readout of the relative humidity status (Blue ON / Grey OFF).
Use the dials as follows:
1. Tap the dial you want to set. A pop up of the dial appears:
2. Set the value by tapping :
Tap to increase or decrease the value step by step.
Hold the to quickly increase or decrease the value.
3. Tap to confirm or to cancel all the settings in the popup window.
The temperature control ensures it does not become too cold in the section. If the temperature drops below the
set value, the computer will make a correction.
Dial
Setting the setpoint heating.

Aura 37
User settings
8
Setting the start temperature ventilation (setpoint house).
Setting the end temperature ventilation.
Setting the setpoint cooling.
Setpoint heating and Setpoint cooling can be linked to the Setpoint house temperature.
The ventilation control ensures there is always a settable minimum amount of fresh air. If the temperature in the
house becomes too high, the controller will provide extra ventilation.
Dial
Setting of the minimum ventilation.
Setting of the maximum ventilation.

Aura 37
User settings
9
The relative humidity control ensures there is always a settable minimum humdity percentage. If the relative
humidity in the house becomes too low, the controller will provide extra moisture.
Dial
Setting of the relative humidty setpoint.
It is possible to set the curve for temperature, relative humidity and ventilation. There are 10 bending points. At a
bending point start by entering the day number; the settings at this bending point apply to this day number.
Readout of the actual control values (setpoints).
Setting to adjust the offset between setpoint and curve value.
Readout of calculated curve values of the concerning day.

Aura 37
User settings
10
1,2,3...10
Readout of the bending points of the curve (maximum 10).
Setting of the day on which the new curve values must apply.
Setting of the curve value (ºC/ºF) for the start temperature ventilation (setpoint
house).
Setting of the curve value (%) for relative humidity.
Setting of the curve value (%) for minimum ventilation.
Setting of the curve value (%) for maximum ventilation.
The day number is a counter increased by the controller each day at midnight by one up to a maximum
of 999. If the day number is 0 it will not change. The Aura 37 then controls without the curve, even if the
bending points have been set.
If a curve is used, the day number is the basis used to calculate the setpoints from the relevant curve. If
a negative day number is set, the Aura 37 will control without using the curve, until the day number is a
positive number. A negative day number is also increased at midnight by one, except the jump from day
–1 to day +1 (a jump of 2).

Aura 37
User settings
11
Readout of the highest, actual and lowest measured temperatures of temperature
sensor 1. Followed by the time of measurement.
Readout of the highest, actual and lowest measured temperatures of temperature
sensor 2. Followed by the time of measurement.
Readout of the highest, actual and lowest measured temperatures of outside
temperature sensor. Followed by the time of measurement.
Readout of the highest, actual and lowest measured temperatures of relative
humidity. Followed by the time of measurement.
The highest and lowest values are measured over the last 24 hours.
Registration of water, feed and auxiliary inputs, representing the today, yesterday, day before yesterday values
and the total value since last reset.
Setting of the registration of today.
Readout of the registration of yesterday.

Aura 37
User settings
12
Readout of the registration of the day before yesterday.
Readout of the cumulative registration over the entire flock.
Readout of the amount of water registered.
Readout of the amount of feed registered.
Readout of the amount of auxilary registered.
Setting to reset all registration data to 0.
This menu shows the status and control values of the outputs.
Readout of the actual calculated position of the fans and the temperature on which
the fan is currently controlled.
Readout of the ventilation status (8 combi fans) (Blue ON / Grey OFF).
Readout of the heating status (Yellow ON / Grey OFF) and the temperature on which
the heating is currently controlled.
Readout of the cooling status (Blue ON / Grey OFF) and the temperature on which
the cooling is currently controlled.
Readout of the relative humidity status (Blue ON / Grey OFF) and the percentage on
which the relative humidity is currently controlled.
Readout of the actual calculated position of the sidewall inlet.
Readout of the actual calculated tunnel inlet position.

Aura 37
Alarm
13
The Aura 37 displays the alarm overview by pressing . There are two types of alarm:
1. Loud alarm: An active loud alarm sounds a siren, shows an alarm message and a report on the screen. This
type of alarm has a high priority.
2. Silent alarm: An active silent alarm shows an alarm message and a report on the screen. This type of alarm
has a low priority.
Status
Readout / setting the alarm status:
Alarm stand by: no alarm (stand by mode).
Alarm test: test the alarm and after reset the status will be changed to Alarm
stand by.
Alarm recovered: there was an alarm which has been recovered. The controller
switches off the alarm, but the alarm status remains visible.
Silent alarm: alarm message shown on screen only.
Alarm temp. off: switch off the current alarm. When the alarm situation has been
cancelled, this status will automatically become Alarm stand by. Always check
that the status has reverted to Alarm stand by.
Alarm disabled: switch off the alarm entirely. Only do this when houses are
unoccupied. Do not forget to reset the status to Alarm stand by.
Alarm: the type of alarm is shown on the screen.
-: function not in use.
Message
Readout of the alarms (see table below).

Aura 37
Alarm
14
Alarm messages
Temperature alarms
Alarm
Action
Min.house temp. (abs)
Max.house temp. (abs)
Min.house temp. (dif)
Max.house temp. (dif)
Minimum alarm
Check wiring and sensors.
Check if the heater works properly (if available).
Check minimum difference alarm settings.
Maximum alarm
Check wiring and sensors.
Check if the cooling works correctly (if available).
Check maximum difference alarm settings.
Check absolute maximum alarm settings.
System alarms
Alarm
Action
Backup alarm
The control computer will be active on factory settings. Please check the
settings.
Watchdog alarm
Communication alarm
Setting changed
Stack overflow
Communication assignment
EPROM error
System error
Protected software
The control computer also tests a number of functions of the
control computer itself. Always warn the installer if a system
alarm occurs.
Power failure
When the control is powered up, a silent alarm will be given.
Sensor failure
Sensor measurement is reliable between -9.9 and +99.9. The control
computer will give an alarm when the sensor goes out of range. The
control computer will continue controlling based on another sensor if
connected.

Aura 37
Alarm
15
If the value responsible for causing the alarm comes within the alarm limits again, the situation is
considered recovered and the alarm is no longer active. The siren automatically disables and the alarm
status changes into Alarm recovered. This message remains visible so you can see what caused the
alarm. Press to change the alarm status into Alarm temp. off followed by Alarm stand by.
If an alarm occurs the ‘menu selection and alarm bar’ will flash red. Perform the following actions in case of a:
1. Press . The alarm overview displays the alarm status Alarm and shows the alarm message.
2. Press once more. The siren will temporarily go off and the alarm status changes to Alarm temp. off. The
alarm message remains visible to investigate what caused the problem.
3. Solve the alarm situation. When the alarm situation is solved the alarm status changes into Alarm stand by.
1. Press . The alarm overview displays the alarm status Alarm and shows the alarm message.
2. Solve the alarm situation.
3. Press once more. The alarm message will disappear and the alarm status changes into Alarm temp. off
followed by Alarm stand by.
If the alarm is disabled the control computer will not generate any alarm messages (except system
alarms). Never switch the alarm off during regular operation.
The alarm can be fully disabled, e.g. when the house is empty. Disable the alarm as follows:
1. Press .
2. Change the alarm status to Alarm disabled. The control computer will give a warning to indicate that the
entire alarm system has been disabled and will flash red.
Reactivate the alarm by changing the alarm status to Alarm stand by. The alarm message states that the alarm
has been disabled and is active again. The message will be cleared from the alarm overview.
Fancom advises testing the alarm weekly for correct functioning. During the test the control computer
will give a loud alarm.
Test the alarm as follows:
1. Press .
2. Change the alarm status to Alarm test. The ‘menu selection and alarm bar’ will flash red and the control
computer prepares an alarm message. The Alarm overview displays the alarm message.
3. Clear the alarm by pressing . The alarm status changes into Alarm stand by.

Aura 37
Alarm
16
Abs. Maximum alarm
If the house temperature is higher than the set Abs. maximum alarm, the control
computer will give a maximum temperature alarm.
Dif. Maximum alarm
The control computer gives a maximum temperature difference alarm if the house
temperature is above: Calculated end temperature ventilation + Dif. Maximum alarm
(the calculated temperature is shown between brackets).
Calculated end temperature ventilation: 24ºC
Dif. Maximum alarm: 3ºC
Calculated alarm limit: 27ºC
An alarm will occur if a temperature becomes higher than the maximum
alarm limit: 24 + 3 = 27°C.
On hot summer days the temperature in a section can be very high. This
can result in a maximum alarm or the difference alarm will have to be set
high. This is not desirable with lower temperatures; the maximum alarm
limit would then be unnecessarily high. In order to provide effective alarms
(dif. maximum alarm as small as possible) the computer increases the
alarm limit parallel to the outside temperature, as soon as this is higher than
the point at which ventilation is maximum.
Calculated end temperature ventilation: 24ºC
Outside temperature: 25ºC
Max. difference alarm: 3ºC
Calculated alarm limit: 28ºC
An alarm will occur if a temperature becomes higher than the maximum
alarm limit: 25 + 3 = 28°C.
Calculated end temperature ventilation: 24ºC
Outside temperature: 35ºC
Max. difference alarm: 3ºC
Calculated alarm limit: 27ºC
Absolute maximum alarm: 35ºC
An alarm will occur if a temperature becomes higher than the maximum
alarm limit: 24 + 3 = 27°C. The maximum alarm is however limited by the
absolute maximum alarm to 35°C.
Abs. Minimum alarm
If the house temperature is lower than the set Abs. Minimum alarm, the control
computer will give a minimum temperature alarm.

Aura 37
Alarm
17
Dif. Minimum alarm
The control computer gives a minimum temperature difference alarm if the house
temperature is below: Start temperature ventilation - Dif. Minimum alarm.
Start temperature ventilation: 20ºC
Dif. Minimum alarm: 4ºC
Calc. min. alarm limit: 16ºC
An alarm will occur if the temperature becomes lower than 16ºC.
Temperature sensor failure
Measurements from connected sensors (except the outside sensor) are reliable as long as measurements are
between -9.9ºC and +99.9ºC. Outside these limits, the measurements are unreliable. The control computer will
give an alarm. This can mean that the temperature sensor has not been correctly connected or is defective. The
screen displays # at the temperature readout.
The control computer stores the alarm history..
The computer stores the last six alarm messages.
Table of contents
Popular Control Panel manuals by other brands

Ptotec
Ptotec 3300 Installation, commissioning and maintenance manual

Salda
Salda MC-HRS Service manual

urmet domus
urmet domus Elkron C420 installation manual

Honeywell
Honeywell Tuxedo Touch Wi-Fi Installation and setup guide

Simplex
Simplex 4100-9401 Assembly/installation instructions

Zeta
Zeta Classic 2000 MKII Installation and operation manual