Fancom iM.60 User manual

iM.60
G
MANUAL NHANDLEIDING D
ANLEITUNG
GND

N.B.: The original, authentic version of this manual is the English version produced by Fancom B.V. or one of its
daughter companies (referred to further as Fancom). Any modifications introduced to this manual by third parties
have neitherbeen checkednor approved by Fancom. Modifications are taken by Fancomto include translations into
languages other than English and the insertion and/or deletion of text and/or illustrations to/from the original
contents. Fancom cannot be held liable for any damages, injury, guarantee claims and other claims relating to this
type of modification, in as far as these modifications result in a content that differs from the original English version
of this manual produced by Fancom. For the latest information about product installation and operation, please
contact the customerservice dept. and/or the technical service dept. of the Fancom company concerned. In spite of
the care taken when compilingthis manual, if you should discover any errors, please inform Fancom B.V. in writing.
Fancom B.V., PO Box 7131, 5980 AC Panningen (the Netherlands).
Copyright © 2014 Fancom B.V.
Panningen (the Netherlands)
All rights reserved. Nothing from thismanual may be copied,distributed or translated into other languages, partly or
wholly, without express prior written permission from Fancom. Fancom reserves the right to modify this manual
without notice. Fancom can give no guarantee, neither implicit nor explicit, for this manual. All risks are for the user.
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V.
Art.Nr. 35911713
GB140401
Gnd

Gnd
i
g
Table of contents
1. General introduction .................................................................................................................................. 1
1.1 Fancom helpdesk........................................................................................................................... 1
1.2 How to use this manual..................................................................................................................1
1.3 Safety instructions and warnings....................................................................................................1
2. Installing the iM.60...................................................................................................................................... 2
2.1 Placing the iM.60............................................................................................................................2
2.2 Mounting the coercion roller ...........................................................................................................3
2.3 Mounting the steel cable on the coercion roller ..............................................................................4
2.4 Mounting the strap drum and strap.................................................................................................4
2.5 Mounting the pipe chain drive (optional).........................................................................................5
2.6 Mounting the CE cover...................................................................................................................5
2.7 Connecting the iM.60......................................................................................................................5
2.8 Testing the iM.60............................................................................................................................7
3. Using the iM.60 ........................................................................................................................................... 8
3.1 Setting the switch ...........................................................................................................................8
3.2 Remote manual operation ..............................................................................................................8
4. Adjusting the iM.60..................................................................................................................................... 9
4.1 Adjusting limit switches................................................................................................................. 11
4.2 Adjusting the CLOSED position.................................................................................................... 13
4.3 Adjusting the OPEN position ........................................................................................................ 13
4.4 Adjusting the PREDEFINED position............................................................................................ 14
4.5 Completing adjustments............................................................................................................... 14
5. Extra possibilities..................................................................................................................................... 15
5.1 Using the emergency battery (optional)........................................................................................ 15
5.2 Predefined position / adjusting independently .............................................................................. 15
5.3 Reversing the direction of rotation................................................................................................ 16
5.4 Connecting the maximum thermostat........................................................................................... 16
6. Alarms ....................................................................................................................................................... 17
7. Technical specifications .......................................................................................................................... 18
8. Appendix: connection diagram............................................................................................................... 20
9. EG declaration of conformity................................................................................................................... 21

Gnd
1
g
1. General introduction
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V.
1.1 Fancom helpdesk
For any questions and support, please contact the local Fancom Sales & Service Center.
1.2 How to use this manual
The following symbols are used in this manual:
Tips and suggestions.
Note providing recommendations and additional information.
Warning indicating damage to the product if you do not follow procedures carefully.
Warning indicating danger to humans or animals.
Electrical shock hazard. Danger to humans and animals.
Example of a practical application of the described functionality.
Calculation example.
1.3 Safety instructions and warnings
Before installing and commissioning the iM.60, read the safety instructions, provisions and conditions carefully. This
paragraph contains a number of general safety instructions. The installation of the device and remedying of any
malfunctions should be performed by a certified electrical installer according to the applicable norms. The guarantee
does not apply if this product is installed in any other way than is indicated by Fancom and if the product's motor has
been opened and changes have been made to the product.
Prevent electrostatic discharge (ESD) when working on the iM.60. Ensure that the workplace is clean and
dry.
Check the iM.60 for proper functioning regularly.
Never install a damaged iM.60! Notify your supplier of any damages.
Do not touch any of the iM.60 moving parts.

Gnd
2
g
2. Installing the iM.60
Install the iM.60 and associated components as follows:
1. Place the iM.60 (see page 2)
2. Mount the coercion roller (see page 3)
3. Mount the steel cable on the coercion roller (see page 3)
4. Mount the strap drum and strap (see page 4)
5. Mount the pipe chain drive (optional) (see page 4)
6. Mount the CE cover (see page 5)
7. Connect the iM.60 (see page 5)
8. Test the iM.60 (see page 7)
2.1 Placing the iM.60
Never place the iM.60 in a place where the weather has direct influence (not in the sun, not in places
where the temperature can rise sharply etc.).
Place the iM.60 at such a height that the manual control can be used.
Do not place the iM.60 with the driveshaft pointing upwards. This keeps water from entering the motor via
the drive
shaft. If you do place the iM.60 with the driveshaft pointing upwards, thenmount the CEcover on
the shaft.

Gnd
3
g
1. Drill holes in the floor surface. For this, you can use the included drill template. Ensure at least 130 mm of free
space behind the iM.60. This is the space required to disassemble the cover.
2. Place the iM.60 on a flat subsurface with the screw fittings on the bottom.
If the iM.60 cannot be placed on a flat subsurface, you can use the included shims (0.5 mm and 1.0 mm
thickness).
3. Seal the screw fittings with grout to prevent penetration of moisture, dust and/or corrosive gases.
2.2 Mounting the coercion roller

Gnd
4
g
2.3 Mounting the steel cable on the coercion roller
Ensure that you have the steel cable on the correct side and that you have the prope
r direction of rotation
for coiling up the steel cable.
1. Pull the steel cable through the hole in the flange.
2. Mount the retaining clip on the end of the steel cable.
3. Wrap the steel cable around the flange at least once.
2.4 Mounting the strap drum and strap
Ensure that you have the strap on the correct side and that you have the proper direction of rotation for
coiling up the strap.

Gnd
5
g
2.5 Mounting the pipe chain drive (optional)
The chain drive is suitable for 1-inch pipe.
2.6 Mounting the CE cover
Placement of
the CE cover is mandatory if the iM.60 is installed within reach (lower than 2.5 m above the
subsurface) of humans or animals.
2.7 Connecting the iM.60
You may connect to the iM.60 as an I/O network module or as a traditional terminal.
Make sure that the iM.60 is well and properly grounded according to the guidelines.
Install the cables in such a way that they cannot become damaged and so that they can easily be
replaced in the event of malfunction. Limit the length of the cables much as possible.
Low-voltage and high-voltage wires may not be placed parallel to each other but may cross each other.
When using metal ducts, Fancom advises grounding the ducts at the ends and at as many other places
as possible.

Gnd
6
g
Connection as an I/O network module
Setting the I/O address
Using the table below, set the I/O address with the dipswitch.
In an I/O network, all iM.60 units must have a unique address.
I/O
address DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8
AN.
ON
ON
ON
ON
ON
N/A
N/A
N/A
1
OFF
ON
ON
ON
ON
2
ON
OFF
ON
ON
ON
3
OFF
OFF
ON
ON
ON
4
ON
ON
OFF
ON
ON
5
OFF
ON
OFF
ON
ON
6
ON
OFF
OFF
ON
ON
7
OFF
OFF
OFF
ON
ON
8
ON
ON
ON
OFF
ON
9
OFF
ON
ON
OFF
ON
10
ON
OFF
ON
OFF
ON
11
OFF
OFF
ON
OFF
ON
12
ON
ON
OFF
OFF
ON
13
OFF
ON
OFF
OFF
ON
14
ON
OFF
OFF
OFF
ON
15
OFF
OFF
OFF
OFF
ON
16
ON
ON
ON
ON
OFF
17
OFF
ON
ON
ON
OFF
18
ON
OFF
ON
ON
OFF
19
OFF
OFF
ON
ON
OFF
20
ON
ON
OFF
ON
OFF
21
OFF
ON
OFF
ON
OFF
22
ON
OFF
OFF
ON
OFF
23
OFF
OFF
OFF
ON
OFF
24
ON
ON
ON
OFF
OFF
25
OFF
ON
ON
OFF
OFF
26
ON
OFF
ON
OFF
OFF
27
OFF
OFF
ON
OFF
OFF
28
ON
ON
OFF
OFF
OFF
29
OFF
ON
OFF
OFF
OFF
30
ON
OFF
OFF
OFF
OFF
31
OFF
OFF
OFF
OFF
OFF

Gnd
7
g
Setting the temperature measurement
As an I/O network module, the iM.60 can measure the temperature itself. This value can be used by the control
computer or for independent regulation in case of emergency.
Set JP1 to T.
Set Dip 6 to OFF.
Connection as a traditional terminal
When used as a traditional terminal, the iM.60 is controlled by a signal voltage of 0/10V or 10/0V. No temperature
measurement is possible in this application.
Set JP1 to U.
Set Dips 1 through 6 to ON.
Electrical connection
Turn on the electricity after you have connected the iM.60.
Switch on the power only after all cables have been connected correctly.
2.8 Testing the iM.60
1. Check whether the iM.60 has been connected correctly.
2. Check whether the iM.60 works optimally.

Gnd
8
g
3. Using the iM.60
3.1 Setting the switch
The switch on the front of the iM.60 allows for:
•Automatic regulation (A),
•manual closing/opening or
•off (0).
The manually operated selections work directly on the motor,
bypassing the intelligent module.
3.2 Remote manual operation
In order to operate the motor remotely and manually (for example, to disinfect), a 10kΩ potentiometer with a switch
can be connected. Once this has been turned on, the controlvalue for the air inlet will be determined by the position of
this potentiometer (8kΩ = 1%, 0kΩ = 99%).
The remote setting potentiometer takes precedent over all automatic settings - so, also over emergency
settings.
This operating possibility works only if the motor's rotating switch is set to Automatic.

Gnd
9
g
4. Adjusting the iM.60
For safe and proper functioning of the iM.60, the iM.60 must be adjusted:
1. Adjusting the limiting switches (mechanical adjustment)
2. Closed position and the potentiometer that measures the position of the intake valve
3. Open position
4. Predefined position (optional)
5. Completing adjustments
Display
After turning the iM.60 on, three characters are first displayed in sequence. These comprise the software version
number (one character per second). During adjustment, indications appear on the display. In manual mode, the
meanings of the indications are:
Display
indication Meaning
1. Adjustment closed (minimum air inlet position).
2. Adjustment open (maximum air inlet position).
3. Adjustment of the predefined air inlet position.
C. Adjustment of the minimum air inlet position accomplished. (closed)
O. Adjustment of the maximum air inlet position accomplished. (open)
P. Adjustment of the predefined air inlet position accomplished.
F. Adjust: too small difference on the control entrance between closed and open adjustment.
E. Error during the determination of the position within the adjustment procedure. (error)

Gnd
10
g
In automatic mode, the meanings of the indications are:
Display
indication Meaning
0. Idle position, waiting for a change in the control value or feedback.
1. Motor sends closed.
2. Motor sends open.
3. Waiting position after turning on (when controlled via 0-10V).
4. Waiting position after turning on (when controlled via and I own network; duration is dependent
on the address).
5. Minimum waiting position after a sending action.
6. Idle position in which the control is determined by the remote control.
7. Motor is standing still against a limiting switch.
U. Due to problems, the iM.60 now controls based on the predefined position.
L. Due to the I/O network going down, the iM.60 now runs independently based on its own
temperature measurements.
The flashing dot on the display indicates that the intelligent module is functioning normally and is getting
power from a regular 24 V AC source.
Adjustment is only possible if the operation switch is not in the automatic (A) position.
When applying a 0-10V/10-0V connection between the iM.60 and the regulator, the appropriate voltage
must be provided during the adjustment procedure for the open and closed position.
Ensure that the steel cable is always wrapped around the drum at least one complete turn when the air
inlet is completely open.
The minimum rotation from open to closed must be a minimum of 0.7 revolutions.
The minimum difference between the open and closed voltage must be 2.2 V.

Gnd
11
g
4.1 Adjusting limit switches
Check to make sure that all the electrical connections have been made properly before you adjust the
limiting switches.
No. Description No. Description
1 Cam disc in the closed position 7 Potentiometer setting
2 Screw for affixing the cam disc in the closed
position 8 Roller on the switch arm in the closed position
3 Worm gear for fine adjustment of the closed
position 9 Limiting switch for the closed position
4 Cam disc in the open position 10 Limiting switch for the open position
5 Screw for affixing the cam disc in the open
position 11 Roller on the switch arm in the open position
6 Worm gear for fine adjustment of the open
position

Gnd
12
g
To adjust the limiting switches, proceed as follows:
1. Open the iM.60 housing.
2. Position the cam discs (1 and 4) such that these are positioned freely on the shaft (so the you can twist the cam
discs).
3. Place the hand switch in the CLOSED position ().
4. Close the intake valve completely in order to adjust the CLOSED position.
5. Turn the cam disc (1) so that the cam is against the underside of the limiting switch's (9) switch arm roller (8).
6. Tighten the screw (2) on the cam disc. Fine adjustment can be done by turning the worm gear (3).
7. Place the hand switch in the OPEN position ().
8. Close the intake valve completely in order to adjust the OPEN position.
9. Turn the cam disc (4) so that the cam is against the upper side of the limiting switch's (10) switch arm roller (11).
10. Tighten the screw (5) on the cam disc. Fine adjustment can be done by turning the worm gear (6).

Gnd
13
g
4.2 Adjusting the CLOSED position
For 0-10V or 10-
0V control, you should ensure that the control computer's analogue outputsends out 1%
(for an I/O network control system this is not important).
1. Set the manual switch to the CLOSED position () and allow the air intake valve to close.
2. Turn the potentiometer completely to the left.
3. Press the pushbutton until the number 1appears in the display and then release the pushbutton. The propulsion
module is now in the 1% adjustment mode. After releasing the pushbutton, a dash will appear in the display.
4. Adjust the potentiometer with a screwdriver such that the dash is in the middle position of the display.
5. Press the pushbutton to confirm the setting. The letter Cnow appears in the display. This means that the
adjustment was successful.
Is there something other than Cin the display? Then the adjustment was not successful. If no
improvement occurs, continue with the adjustment of the OPEN position. If the OPEN position is now
correctly adjusted, then the adjustment will have been successful.
4.3 Adjusting the OPEN position
For 0-10V or 10-0V control, you should ensure that the control computer's analogue output sends out
99% (for an I/O network control system this is not important).
Factory setting 99% = 0.1V, 4000Ω
•The limiting switch may be adjusted between 95% en 100%. If the desired position is not achieved
during the adjustment (because the limiting switch is being operated), no alarm will be issued.When
activating the limiting switch below 95%, the iM.60 will stop and generates alarm A2.
1. Set the manual switch to the OPEN position () and allow the air intake fell to go to the desired position.
2. Press the pushbutton until the number 2appears in the display and then release the pushbutton. The propulsion
module is now in the 99% adjustment mode. After releasing the pushbutton, a dash will appear in the display.
3. Adjust the length (for example, by cinching) such that the dash is in the middle position of the display.
4. Press the pushbutton to confirm the setting. The letter Onow appears in the display. This means that the
adjustment was successful.
Is there something other than Oin the display? Then the adjustment was not successful. If no
improvement occurs, then repeat the entire procedure.

Gnd
14
g
4.4 Adjusting the PREDEFINED position
Factory setting = 50%. If this is the proper position for you, you don't have to perform the following steps.
1. Set the air inlet with the manual operation switch to the position that should be assumed if mains power is
interrupted.
2. Press the pushbutton until the number 3appears in the display and then release the pushbutton.
3. Press the pushbutton to confirm the setting. The letter Pnow appears in the display. This means that the
adjustment was successful.
4.5 Completing adjustments
After adjustment, set the operating switch to Automatic (A) so that normal functioning is possible.

Gnd
15
g
5. Extra possibilities
5.1 Using the emergency battery (optional)
If a battery pack is built into the iM.60, this is kept topped up by a built-in battery charger. The condition of the battery
is tested automatically during the charging process. If it doesn't meet the requirements (<22Volt) any longer, this is
then shown on the internal display as A5 (see page 17). The condition of the battery is also available via the I/O
network so that a control computer that includes the proper functionality can indicate whenever the battery is no
longer reliable.
Set Dip 7 to OFF.
5.2 Predefined position / adjusting independently
If the control signal or 24 V AC power supply is interrupted, the iM.60 can control the air inlet position independently.
This may be a calculated position or the preferential position (predefined). This predefined position can be set (see
page 13).
No control signal (power)
When the control signal is interrupted, the air inlet will open completely (with a 10-0 V control signal) or close
completely (with a 0-10 V control signal).

Gnd
16
g
No control signal (communication)
If the iM.60 is included in an I/O network and communication is interrupted, then the A4 alarm will appear after 6
minutes. Independent regulation will occur if a temperature sensor is connected. The regulation's basic principles are:
•The current temperature becomes the set point temperature.
•The current valve position becomes the minimal valve position or - if lower - the predefined valve position.
The intelligent module will calculate the air intake position itself based on the temperature measurement and the
settings. In this case, an L will be displayed on the display of the printout by pressing the pushbutton. If no
temperature sensor is connected, the predefined position will be sought. An Lappears on the display.
Loss of power (power failure)
If the regular 24 V AC power is interrupted (as long as an internal emergency battery is connected and the control
current is still good):
•With analogue control, the iM.60 goes to the preferential position (predefined).
•With control via an I/O network, adjust the iM.60 until the battery voltage is lower than 22Volt.After this, the iM.60
will go to the preferential position (predefined).
In both cases, an A3 will be shown on the display.
When using an external emergency power supply (UPS) instead of internal batteries, the 24 V AC will not be
interrupted. The UPS must, however, be equipped with a Power Fail (PF) output (normally open contact) that
connects the PF input on the iM.60 whenever regular mains power is interrupted. The iM.60 will go to the preferential
position.
5.3 Reversing the direction of rotation
Starting with software version A1.3, the direction of rotation ofthe propulsion motorcan be reversed. Thispossibilityis
used whenever the connection has been made in the opposite direction.
Reversing the direction of rotation negatively impacts precision.
After reversing the direction of rotation, the Open/Close indication on the printout is assigned the opposite
function.
To reverse the direction of rotation, perform the following steps:
1. Remove power from the motor.
2. Set DIP 8 to OFF (= inverse direction of rotation).
3. Switch the connection wires as follows:
•Switch (2) + (3) on the connector of the manual operation switch ((2) becomes brown, (3) becomes white).
•Reverse the potentiometer + and – on the printout (+ (1) becomes green, - (3) becomes red); the L stays in
the same place.
•Reverse the limiting switches on the printout (Open (4+5) becomes black, Closed (6+7) becomes brown).
4. Plug the motor in and perform the adjustment procedure again.
5.4 Connecting the maximum thermostat
You may connect a maximum thermostat as an extra security. The air intake will open completely whenever the
maximum thermostat is activated. The maximum thermostat and a remote control may be switched in parallel. The
maximum thermostat also takes precedence over (overrules) the manual control.
This operating possibility works only if the motor's rotating switch is set to A.

Gnd
17
g
6. Alarms
When an Ais shown in the display, followed by a number, this indicates an alarm. The table below provides an
overview of the alarms.
Alarm
indication
Meaning
A0 Backup alarm: No settings available, adjustment necessary! (via I/O network A100)
A1 Defective memory.
A2 Intake valve position is not achieved.
A3 Interruption of power, system is operating on emergency power facility.
A4 No I/O network communication.
A5 Battery test indicates error.
A7 Alarm test
The notification of a retracted alarm can be deleted by pressing the pushbutton on the printout.
A control computer connected to the iM.60 via an I/O network can take over the alarm notification (as long
as this functionality is supported).
An alarm test (A7) can be executed by pressing the pushbutton until the indication Ais shown in the
display. For this, the rotating switch should be operated manually.
If an alarm indication appears on the display, the alarm relay has been activated.
The calibration value for a maximum potentiometer position may expire in the event of unpowered
overload.
An interruption of power supply due to overload may cause the calibration value to expire in the event of
a maximum stroke in the fully open position.
Table of contents
Languages:
Other Fancom Servo Drive manuals
Popular Servo Drive manuals by other brands

Omron
Omron OMNUC U R88M-U Series user manual

Allen-Bradley
Allen-Bradley Kinetix 5100 2198-E1004-ERS user manual

THORLABS
THORLABS DDSM100 user guide

Watts
Watts EMUK-230-500 Mounting instructions

YASKAWA
YASKAWA E-III Series Safety precautions

Mannesmann Rexroth
Mannesmann Rexroth DDS 2.1 Applications manual