BLUM AVENTOS User manual

Installation instructions – Original
SERVO-DRIVE for AVENTOS
AVENTOS HF AVENTOS HS AVENTOS HL AVENTOS HK

Table of contents Using the installation instructions 3
Safety 3
Intended use 3
Warning signs and danger symbols 3
Safety information 4
Structural changes and spare parts 5
Disposal 5
Function 5
Planning information 6
Orientation diagram 8
Assembly Blum distance bumper 8
Distribution cable 8
Drive unit 9
Orientation diagram Blum transformer and accessories 10
Assembly Blum transformer and accessories 11
SERVO-DRIVE switch 11
Functions SERVO-DRIVE for AVENTOS 13
Start-up SERVO-DRIVE for AVENTOS 14
Deactivation SERVO-DRIVE for AVENTOS 16
LED signals LED displays 16
Assembly Cover cap 17
Replacement SERVO-DRIVE switch battery 17
Removal Drive unit 18
Distribution cable 18
Blum transformer and accessories 18
Troubleshooting 19
2

Using the installation instructions
⇒ Please read the installation instructions and safety information before SERVO-DRIVE for AVENTOS start-up.
⇒ We recommend that you use the orientation diagram for easier identification of the parts being described.
⇒ These installation instructions are for the AVENTOS HF, AVENTOS HS, AVENTOS HL and AVENTOS HK lift
systems.
However, only AVENTOS HF is used as an example in the illustrations.
⇒ Please see the special AVENTOS installation instructions for the assembly steps of the mechanical AVENTOS HF, HS,
HL and HK lift systems without SERVO-DRIVE.
Safety
SERVO-DRIVE for AVENTOS complies with current safety standards.
Nevertheless, there are certain risk factors if these installation instructions are
not followed. Please be aware that Julius Blum GmbH is not responsible for
incidental or consequential damages that may arise due to non-compliance
with these installation instructions.
Principle
Intended use SERVO-DRIVE for AVENTOS supports the opening and closing of lift systems
in furniture and may only be used under the following conditions:
• In dry, enclosed rooms.
• In combination with AVENTOS lift systems from Julius Blum GmbH within per-
mitted technical specifications.
• In combination with a Blum transformer.
Warning signs and
danger symbols
DANGER
Danger:
The DANGER sign indicates important safety information
that must be followed. If this information is not followed, this
could lead to serious injury or death.
WARNING
Warning:
The WARNING sign indicates important safety information
that must be followed. If this information is not followed, this
could lead to injury or property damage.
CAUTION
Caution:
The CAUTION sign indicates information that if not followed
may lead to property damage or premature wear.
NOTICE
NOTICE:
The NOTICE sign indicates information that should be
followed.
3

⇒ All national standards must be followed for SERVO-DRIVE for AVENTOS
assembly. This includes, in particular, those related to the mechanical
safety of moving parts and electrical cabling.
⇒ Only qualified technicians may install/replace Blum components, modify
the position of the Blum transformer or modify any cabling.
⇒ The device may only be connected to a power supply that corresponds to
the type and frequency listed on the serial tag (see Blum transformer).
⇒ The outlet must be freely accessible.
⇒ To ensure that lift elements cannot be activated unintentionally, we recom-
mended connecting the Blum transformer to a switched outlet.
⇒ Only 1 Blum transformer may be used per distribution cable.
⇒ Maintain safety distances to the Blum transformer unit listed in the installa-
tion instructions.
⇒ Make sure that moisture cannot penetrate the Blum transformer and drive
unit.
⇒ Before starting repair or maintenance work, unplug the Blum transformer
to disconnect the power.
⇒ The drive unit, Blum transformer and SERVO-DRIVE switch should only
be cleaned with a moist cloth because penetrating moisture and aggres-
sive cleaning materials can damage the electronics of the drive unit, Blum
transformer and SERVO-DRIVE switch.
⇒ Do not touch the area around the lever during the opening and closing
motion.
Safety information
⇒ Never take apart a drive unit or a SERVO-DRIVE switch.
⇒ Damaged parts should not be used.
⇒ Sharp edges may damage the cable.
⇒ Neither the Blum transformer nor any cabling should come into contact
with moving parts.
DANGER
Danger of electric shock
⇒ Never open a Blum transformer. There is a danger of electric shock.
WARNING
There is a danger of injury if the lever springs upward.
There is a danger of injury from the lever springing upwards when the front is
removed.
⇒ Do not push down on lever arm, remove it instead.
⇒ Do not connect the transformer to the power supply while the fronts are
unattached.
4

Structural changes and spare parts not approved by the manufacturer affect
the safety and functionality of SERVO-DRIVE for AVENTOS and are, therefore,
not allowed.
⇒ Only use original spare parts from Julius Blum GmbH.
⇒ Blum SERVO-DRIVE components are the only devices that should be con-
nected to the Blum transformer.
Structural changes
and spare parts
Disposal ⇒ All SERVO-DRIVE for AVENTOS electronic components, including the
battery, should be disposed of in a separate collection for electrical appli-
ances as per local regulations.
Function
⇒ Press on the front
╵→ The lift system opens
automatically
⇒ Press on the SERVO-DRIVE switch
╵→ The lift system closes automatically
⇒ Manual closing of the lift system
by moving it downwards
⇒ Manual opening of the lift system
by moving it upwards
Manual use
SERVO-DRIVE for AVENTOS supports the opening and closing of lift systems
in furniture.
The SERVO-DRIVE switch triggers the automatic opening and closing action of
SERVO-DRIVE for AVENTOS.
Electrical motion
support system
The lift system can be opened or closed manually without restrictions due to
the integrated free movement without damaging SERVO-DRIVE for AVENTOS.
5

* Alternative drilling
1) Only on the left side
Cabinet height
Do not glue the Blum distance bumper
Cabinet height
Recommendation for aluminium frames: Consider drilling Blum distance
bumper into the cabinet side.
A trial application must be carried out when fixing the Blum distance bumper
to the front.
Planning information Prefered position for distribution cable (AVENTOS HF)1)
Blum distance bumper
Blum distance bumper drilling position
For specific applications (low front
with high weight) several bumpers are
necessary.
Bumper must be installed near switch.
A trial application is recommended!
* From cabinet front edge for fronts that protrude below
6
H
480–549 mm KH x 0.3 - 28 mm
550–1.040 mm KH x 0.3 - 57 mm
AVENTOS HF AVENTOS HS / -HL
KH
AVENTOS HK
AVENTOS HF / -HS / -HL AVENTOS HK

1
Connecting piece
[2] half KB (KS 16–19mm) -193 mm
KB Cabinet width
KS Side panel thickness
CAUTION
A safety distance of 30 mm must be maintained
for air circulation; otherwise, there is a risk that the
Blum transformer could overheat.
The dimensions in the drawing take into account
the safety distance.
SERVO-DRIVE switchPlanning information
Cross stabiliser
Blum transformer safety distance
Cut to size dimension:
[1] KB (KS 16-19 mm) -193 mm and/or inner width -155 mm
7
AVENTOS HS AVENTOS HL

12 2
13
6 7 11
14
5
1 3 4
10
9
8
Installation in the front
Aluminium frame:
Installation in the cabinet side
Do not glue the Blum distance bumper
Assembly Blum distance bumper
Lift mechanism
Telescopic arm or lever arm
Drive unit with LED display
Blum transformer with LED display
Cover cap
Transformer unit housing
SERVO-DRIVE switch with battery display
Distribution cable for cutting to size
Connecting node
Cable end protector
Flex
Cabinet
Blum distance bumper
Front
Orientation diagram
8
1
2
3
4
7
5
8
6
9
10
13
11
14
12

3
2
1
✓✓
HFHSHLLOCKED
2
✓✓
75°
Distribution cableAssembly
Drive unitAdjustment
9
AVENTOS HF / -HS / -HL
AVENTOS HK
AVENTOS HF / -HS / -HL
AVENTOS HK

2
1
3
Drive unitAssembly
NOTICE
Before SERVO-DRIVE for AVENTOS assembly, the lift
mechanisms must be set so that the front remains open
in different positions.
The telescopic arm and/or lever arm must be in the completely open position
for drive unit installation.
If required, attach the opening angle stop only after drive unit installation and
before the reference run.
NOTICE
The drive unit can be locked when the orange slide
is no longer visible in the view window.
NOTICE
The drive unit can be locked once it is correctly located on the AVENTOS
mechanism.
✓
10
AVENTOS HF / -HS / -HL
AVENTOS HK
AVENTOS HF / -HS / -HL
AVENTOS HK

Blum transformer and accessoriesOrientation diagram
CAUTION Only 1 Blum transformer can be connected to each distribution cable.
Assembly on the top panel Assembly in combination with SERVO-DRIVE
for pull-out systems
Back cabling Upper cabling
11

Pull-out stop
Do not damage
piercing pins.
Assembly Blum transformer and accessories
Assembly SERVO-DRIVE switch
12

Button layout
Start-up
Deactivation
Additional features
Activating the SERVO-DRIVE switch
Activating synchronisation
Activating collision avoid-
ance
Reset Wireless
Reset Motion
Start reference run
Optional
Drive unit
SERVO-DRIVE switch
<Reset Motion> button
Motion LED
<COLL> button
<SWITCH> button
<Reset Wireless> button
<SYNC> button
Wireless LED
Overview SERVO-DRIVE for AVENTOS functions
13
A
C
D
F
E
B
1
2
3
4
7
5
8
6
9

Repeat procedure A 1–2 for additional SERVO-DRIVE switches in the
cabinet.
Press the SERVO-DRIVE switch until the LED lights up green continuously
Press on front: The reference run starts automatically
Front opens and closes 2x automatically:
Under no circumstances should you try to manually interrupt or stop the
process
Reference run is required:
LED flashes
Close the front manually
If there is an interruption, reset the reference run
→ see Reset Motion E 1. The reference run restarts.
Start-up SERVO-DRIVE for AVENTOS
Activating the
SERVO-DRIVE
switch
Each switch can only be allocated to one SERVO-DRIVE unit.
Press the <SWITCH> button until the LED flashes green.
The drive unit recognises the required parameters using the reference run.
Operation Lights up continuously Flashes
Setting up the wireless connection between the SERVO-DRIVE switch and the drive unit.
Start reference
run
NOTICE
Additional features must be activated before the reference run.
Activating synchronisation
Activating collision avoidance
14
1
1
2
4
2
3
3
C
D
A
B

SERVO-DRIVE for AVENTOS additional features
Repeat procedureC 2–3 for all additional drive units.
Repeat procedure D 2–5 for all additional cabinets.
Activating
synchronisation
Press the <SYNC> button on the first drive unit until the LED flashes green
Press the <SYNC> button on the second drive unit until the LEDs on both syn-
chronised drive units light up green continuously
Activating colli-
sion avoidance
Press the <COLL> button on the first drive unit until the LED flashes green
Close the front manually
Activating the SERVO-DRIVE switch → see A 1–3.
Open the second front manually
Press the <COLL> button on the second drive unit until the LED lights up
green continuously
If there is an activation error, reset all drive units → see Reset Wireless F 1.
Re-activate the SERVO-DRIVE switch, synchronisation and the reference run
→ see A 1–3, C 2–4 and B 1–4.
If there is an activation error, reset all drive units → see Reset Wireless F 1.
Re-activate the SERVO-DRIVE switch, collision avoidance and the reference
run → see A 1–3, D 2–6 and B 1–4.
Up to three drive units can be synchronised allowing them to move simultaneously.
This function is required for several cabinets with a uniform front.
To avoid the collision of fronts, drive units (max. 6) are linked so that only one front
can be opened at a time. A front is prevented from opening as long as a linked front
remains open.
Operation Lights up continuously Flashes
Activating the SERVO-DRIVE switch → see A 1–3.
Carry out reference run → see B 1–4.
Carry out reference run → see B 1–4.
Start-up
15
2
3
4
2
3
4
5
6
1
1
5
7
C
D

Wireless LED signals
Flashes green ⇒ Activation mode
Lights up green continu-
ously
⇒ Activation confirmation
Flashes green quickly ⇒ Deactivation confirmation
Lights red continuously ⇒ Last process was not completed
successfully
Motion LED signals
Flashes orange ⇒ Reference run is required
Lights orange continu-
ously
⇒ Power available /
Operating mode display /
Reference run was completed
successfully
Flashes orange quickly ⇒ Reset Motion confirmation
Flashes quickly
Press the <Reset Motion> button using a pen (at least 3 seconds) until the
LED flashes quickly.
Press the <Reset Wireless> button using a pen (at least 3 seconds) until the
LED flashes quickly.
Resets the reference run and enables a new reference run to be started.
Deactivates all functions.
All active SERVO-DRIVE switches, synchronisations and collision avoidance settings for the respec-
tive drive unit are deleted.
Reset Motion
Reset Wireless
Deactivation SERVO-DRIVE for AVENTOS
16
1
1
E
F

Insert new battery
Type: CR2032
NOTICE
⇒ Only use type CR2032 batteries from known manufacturers.
⇒ Make sure that the new battery is inserted correctly (note proper pole
connections +/-).
CAUTION
⇒ The SERVO-DRIVE switch battery must not be recharged or thrown into
fire.
NOTICE
If the battery is inserted incorrectly, the SERVO-DRIVE switch battery display
flashes red.
Please note
proper pole
connections
(+/-)
NOTICE
When battery power begins to weaken, the SERVO-DRIVE switch battery
display flashes red.
Assembly Cover cap
Replacement SERVO-DRIVE switch battery
17

1
2
1
DANGER
⇒ Before starting repair or maintenance work, unplug the Blum transformer
to disconnect the power.
⇒ Never open a Blum transformer. There is a danger of electric shock.
Do not damage piercing pins.
Removal
Removal Blum transformer and accessories
Removal Distribution cable
Drive unit
18
AVENTOS HF / -HS / -HL
AVENTOS HK

We recommend the following troubleshooting sequence.
Problem Possible cause Remedy
NOTICE
When using several SERVO-DRIVE switches in one cabinet, all
SERVO-DRIVE switches must be checked individually.
Troubleshooting
1 Front does not move
either by pressing on
the front or pressing the
SERVO-DRIVE switch
Front and/or SERVO-DRIVE switch
was not pressed long enough
Make a deliberate effort to press the
front and/or SERVO-DRIVE switch
(to the full extent of travel)
Front and/or SERVO-DRIVE switch
was pressed too long (leaning pro-
tection triggered)
Press the front and/or SERVO-
DRIVE switch for a briefer time
Blum transformer is not connected
to the power outlet
• Connect the flex to the Blum trans-
former and to the power outlet
• Turn on the switched outlet
Battery was inserted incorrectly into
the SERVO-DRIVE switch
╵→ Battery display on the SERVO-
DRIVE switch lights red
Insert battery correctly
Drive unit is not attached properly to
the lift mechanism
Correctly install drive unit
The SERVO-DRIVE switch is not
activated
Activate the SERVO-DRIVE switch
Collision avoidance was activated
in error
╵→ A second front would be open if
this scenario is correct
Deactivate collision avoidance
Battery is dead Replace battery
SERVO-DRIVE switch is defective Replace SERVO-DRIVE switch
Drive unit is defective Replace drive unit
Cabling or Blum transformer is
defective
Replace cabling and/or Blum
transformer
19

Do not damage piercing pins.
Problem Possible cause Remedy
Do not damage piercing pins.
2.1 The Motion LED on a
drive unit does not light
up
Cabling to drive unit was not per-
formed correctly
Trim distribution cable and re-attach
to drive unit
Distribution cable was connected
incorrectly
Connect distribution cable correctly
Drive unit is defective Replace drive unit
Connecting node is defective Replace connecting node
Distribution cable is defective Replace distribution cable
2.2 The LED on the Blum
transformer lights, the
Motion LED on several
drive units does not
Connecting node between distribu-
tion cable and Blum transformer is
defective
Replace connecting node between
distribution cable and Blum
transformer
Distribution cable is defective Replace distribution cable
2.3 The LED on the Blum
transformer does not
light
Switched outlet is turned off Turn on switched outlet
Blum transformer is not connected
to the power outlet
Connect the flex to the Blum trans-
former and to the power outlet
Blum transformer is defective Replace Blum transformer
2.4 LED does not light on
either the Blum trans-
formers or the drive units
• Two Blum transformers are con-
nected to one distribution cable
• Both Blum transformers are
defective
Only 1 Blum transformer can
be connected to each distribution
cable
Replace defective Blum transform-
ers with 1 Blum transformer
20
This manual suits for next models
4
Table of contents
Other BLUM Servo Drive manuals
Popular Servo Drive manuals by other brands

Technosoft
Technosoft iPOS4808 MY-CAN Technical reference

Technosoft
Technosoft Micro 4803 MZ Technical reference

Mitsubishi Electric
Mitsubishi Electric MELSERVO-J5 MR-J5-G Series user manual

YASKAWA
YASKAWA S-7 Series manual

SEW-Eurodrive
SEW-Eurodrive CMP Series Addendum to the operating instructions

Rockwell Automation
Rockwell Automation Allen-Bradley Kinetix VP Series installation instructions