MICROWAVE MOTION DETECTOR
Do not dispose of this device to a garbage bin with other unsorted waste!
In accordance with the Waste Electrical and Electronic Equipment Act
any household electro-waste can be turned in free of charge and in any
quantity to a collection point established for this purpose, as well as to the
store in the event of purchasing new equipment (as per the old for new rule,
regardless of brand). Electro-waste thrown in the garbage bin or abandoned
in the bosom of nature pose a threat to the environment and human health.
DRM-02
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase. Contact your
dealeror directly with us. More
information how to make a compliant can
be found on the website:
www.fif.com.pl/reklamacje
5 908312 593966
- 3 - - 4 -
- 2 -
- 1 -
Purpose
The motion detector is used for automatic, temporary lighting attach
if a person or another object appears in detector’s range in places such
as hallways, courtyards, approaches and driveways, garages, etc.
Microwave sensor allows for motion detection by wooden boards,
plasterboard panels, glass and plastics.
Functioning
DRM sensor emits and bounces high-frequency 5.8 GHz electromagnetic
waves. The sensor detects changes in the reflected waves caused
by movement of the object in the area of detection. The sensor detects
movement of an object to and from the sensor. Movement in the range
of detection will automatically attach the lighting for time set by the user.
After this time the lights will be turned off automatically. The motion sensor
is equipped with light dependant relay able to attaching lighting during
the day. Detection status and standby to attach lights are activated only after
dusk. Sensor activation time might be adjust by the user.
In addition, there is a possibility of adjustment of the detection area in range
3-10 m (for h= 2.5 m) and the receiver actuation time adjustment
to 8 s ÷ 12 min. The inclusion of the receiver is signaled by a shining green LED.
Sensor can work indoors. The sensor allows for motion detection by wooden
boards, plasterboard panels, glass and plastics. Temperature changes do not
affect on motion detection
ATTENTION!
The power of microwave radiation is relatively low and is completely safe for
humans and animals. Its value is less than 10 mW. By comparison,
microwaves and cell phones radiate about 1000mW of power (100 times
harder).
Ç
R
?
Ç
Detection range
Radius of the sensor detection can be adjusted in the range from
2 m to 10 m (the parameters for the sensor mounted at a height
of 2.5 m). Rotate the knob to the right [max] increases the area of
a field of detection, rotate left [min] reduces the area of the field
detection.
Actuation time
Receiver’s actuation time can be adjusted between 8 s for 12 min.
Rotate knob to the right [max] increases ON time, rotate left [min]
reduces the attached time. After a set time receiver is turned off
automatically.
Sensitivity of light dependant relay
Sensitivity of light dependant relay can be adjusted in
range from 2 Lx to 2000 Lx. Rotate the knob toward to the „moon”
sign - attached later, rotation to the „sun” sign - attached earlier.
In order to sensor was active throughout the day, set the knob
maximally toward the „sun”.
Settings
Technical data
supply 230V AC
current load <5A
frequency of the microwaves radiation 5,8GHz
power radiation <10mW
detection range 360°
detection ray - adjustable (for h=2,5m) 1÷10m
activation treshold - adjustable 2÷2000Lx
receiver’s activation time - adjustable 8s÷12min.
activation delay 1s
connection screw terminals 1mm
working temperature -25÷50°C
dimensions 42mm
power consumption 0,9W
fixed two screws to the substrate
protection level IP40
²
Ø103 h=
Assembly
Device assembly
1. Unscrew the outer shield of the detector. Unscrew the two screws and
remove the sensor cover (Pict. 1).
2. Disconnect the power.
3. Wires provide throughout eyelet rubber in mounting base of the sensor.
4. Basis with two screws attached to the substrate.
5. Connect according to schema.
6. Set area of detection, set the sensitivity of the light dependant relay and
activation time.
7. Assemble the sensor’s cover housing
(Pict. 2).
(Pict. 3).
Wiring diagram
L
N
N
L
L'
DRM
Pict. 1
Pict. 3
Pict. 2
D150629
X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Photoelectric Sensors category:
Click to view products by F&F manufacturer:
Other Similar products are found below :
E3JM-DS70R4T-US E3L2DC4 E3RA-DN12 2M E3RA-DP12 2M E3S5LE4S E3S-AD38 E3S-CR11 5M E3SCT11D5M E3SCT11M1J03M
E3T-SL14R E3T-SL24 5M E3T-ST12R E3X-CN02 E3X-CN11 5M E3X-CN21 10M E3ZM-B66 E3ZM-CL81H 2M E3Z-T62 2M
NJL5303R-TE1 PB10CNT15PO PD60CNX20BP CX-491-P-J CX-491-Z XUM2BKCNL2T XUM2BKCNL2T XUM2BNANL2R Y92E-
ES30M Y92E-GS08SS ZXTDS04T ZX-XC4A 4M E3E23Y2US E3JM-DS70S4-US E3RA-RN11 2M E3S5LE42M E3S-LS20XB4 5M
E3TFD14N E3T-FD14R E3T-SL21 5M E3T-SL21M E3T-ST11R E3T-ST12 5M E3X-DA41-S-M1J 0.3M E3X-DAB6 E3X-DAG8 E3ZM-
B86 E3ZM-CR81 2M E3ZM-CR86 E3Z-T61A-L 2M ZX-XGC2R ZX-XB1A

Other F&F Security Sensor manuals

F&F DRM-05 User manual

F&F

F&F DRM-05 User manual

F&F DRM-02 User manual

F&F

F&F DRM-02 User manual

F&F CKF-318 TRMS User manual

F&F

F&F CKF-318 TRMS User manual

F&F DR-09B-IP65 User manual

F&F

F&F DR-09B-IP65 User manual

F&F DRM-02 24 V User manual

F&F

F&F DRM-02 24 V User manual

F&F DRL-60-230 User manual

F&F

F&F DRL-60-230 User manual

F&F DR-08 User manual

F&F

F&F DR-08 User manual

F&F DR-04W User manual

F&F

F&F DR-04W User manual

F&F DR-09 24V User manual

F&F

F&F DR-09 24V User manual

F&F DR-03 User manual

F&F

F&F DR-03 User manual

F&F DRL-60-12 User manual

F&F

F&F DRL-60-12 User manual

F&F DR-30M User manual

F&F

F&F DR-30M User manual

F&F DR-04G User manual

F&F

F&F DR-04G User manual

Popular Security Sensor manuals by other brands

IFM Electronic OPU2 Series operating instructions

IFM Electronic

IFM Electronic OPU2 Series operating instructions

DMP Electronics DEL AOP PRO 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

DMP Electronics

DMP Electronics DEL AOP PRO 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

B.E.G. LUXOMAT PD4-S Series manual

B.E.G.

B.E.G. LUXOMAT PD4-S Series manual

CS Instruments LD 450 instruction manual

CS Instruments

CS Instruments LD 450 instruction manual

Facom SLS.G13 instruction manual

Facom

Facom SLS.G13 instruction manual

Gira 180 plus installation instructions

Gira

Gira 180 plus installation instructions

Berker 7524 10 04 installation instructions

Berker

Berker 7524 10 04 installation instructions

APG IRU Series installation guide

APG

APG IRU Series installation guide

showhome ZW1101 quick start guide

showhome

showhome ZW1101 quick start guide

SILENTRON 5120 Small PIR-W quick start guide

SILENTRON

SILENTRON 5120 Small PIR-W quick start guide

BW Technologies GasAlertMax user manual

BW Technologies

BW Technologies GasAlertMax user manual

Bircher Reglomat ProxySwitch user guide

Bircher Reglomat

Bircher Reglomat ProxySwitch user guide

Gewiss GW 90787 Technical manual

Gewiss

Gewiss GW 90787 Technical manual

IFM PN2090 operating instructions

IFM

IFM PN2090 operating instructions

urmet domus 1051 quick guide

urmet domus

urmet domus 1051 quick guide

Theben PlanoCentro 000-E Series operating manual

Theben

Theben PlanoCentro 000-E Series operating manual

WatchGas NEO Service manual

WatchGas

WatchGas NEO Service manual

NA-DE 01051 instruction manual

NA-DE

NA-DE 01051 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.