Fasel Elektronik FCU2000 Series User manual

Technical changes and errors excepted, illustration similar
Series FCU2x00/FCU3x00/FCU4x00
Operating manual
Sauna control
only Sauna with Sauna with humidity with IR
Series FCU2000 FCU2200 ---
Series FCU3000 FCU3200 FCU3400
Series FCU4000 FCU4200 FCU4400
Doc-ID:B_FCUxxxx_EN
Version: V 2.09
certificated

2 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
FASEL GmbH
Germany

Table of contents
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 3
Table of contents
1
Safety................................................................................................................................5
1.1
Explanations of symbols...............................................................................5
1.2
Demands on the operator and technicians...................................................6
1.3
Intended use .................................................................................................6
1.4
Changes and modifications ..........................................................................7
1.5
Operational safety and special dangers .......................................................7
1.6
Information on the operating and installation manual...................................8
2
Identification ....................................................................................................................9
2.1
Nameplate ....................................................................................................9
3
Technical Data:................................................................................................................9
4
Design and function......................................................................................................10
4.1
Function ......................................................................................................10
4.1.1
Sauna ....................................................................................................10
4.1.2
Sauna with humidity (only FCUx200 and FCUx400).............................10
4.1.3
Infrared (only FCUx400) ........................................................................10
4.2
Operating and display elements .................................................................11
4.2.1
FCU4x00 design and FCU4x00 design glass .......................................11
4.2.2
Control keys Sauna control ...................................................................12
4.2.3
Explanation of the display FCU2x00 .....................................................15
4.3
Display symbols..........................................................................................16
5
Operation .......................................................................................................................17
5.1
Safety and instructions ...............................................................................17
5.2
Turn sauna control on and off.....................................................................18
5.2.1
Turn sauna control on ...........................................................................18
5.2.2
Turn sauna control off ...........................................................................18
5.2.3
Select or start the mode ........................................................................19
5.3
Adjust modes ..............................................................................................19
5.3.1
Adjust "Sauna" mode.............................................................................20
5.3.2
Adjust "Sauna with humidity" mode (only FCUx200 and FCUx400).....21
5.3.3
Adjust "Infrared" mode (only FCU3400 and FCU4400) ........................22
5.4
Adjust the set point temperature, humidity, heating- and remaining time ..22
5.4.1
Maximum allowed heating time .............................................................23
5.5
Day timer ....................................................................................................24
5.6
Adjust the brightness of the cabin light (not for FCU2xxx) .........................24
5.7
Adjust the cabin fan speed (not for FCU2xxx)............................................25
5.8
Options menu .............................................................................................25
5.8.1
RGB-LED brightness (only for FCU4xxx and menu "Pro") ...................25
5.8.2
Colour light mode (including parameter description).............................26
5.8.3
Colour light start (only for menu "Pro")..................................................28
5.8.4
Adjust the flavour feed...........................................................................30

Table of contents
4 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
6
"Basic settings" menu ................................................................................................. 31
6.1
"Basic settings" - general ........................................................................... 31
6.1.1
Time and Weekday............................................................................... 31
6.1.2
Weekly timer ON/OFF (only for FCU4xxx) ........................................... 32
6.1.3
Program the weekly timer ..................................................................... 32
6.1.4
Select program (only for FCU4xxx) ...................................................... 34
6.1.5
Adjust display lighting (not for FCU2xxx).............................................. 35
6.1.6
Adjust display contrast (only for FCU4xxx)........................................... 35
6.1.7
Light settings (only for menu "Pro") ...................................................... 36
6.1.8
Fan settings (only for menu "Pro")........................................................ 37
6.2
"Basic settings" for options ........................................................................ 39
6.2.1
RGB-LED settings (only for FCU4xxx and menu "Pro")....................... 39
6.2.2
Colour light automatic (only for menu "Pro") ........................................ 40
6.2.3
Key manual infusion (only for menu "Pro")........................................... 42
6.2.4
Versions and data (only for menu "Pro") .............................................. 42
7
Options menu ............................................................................................................... 44
7.1
Small/professional...................................................................................... 44
7.2
Parental/Keypad lock ................................................................................. 44
7.3
Select language ......................................................................................... 44
8
Maintenance.................................................................................................................. 45
8.1
Cleaning..................................................................................................... 45
9
Malfunctions ................................................................................................................. 45
9.1
Safety......................................................................................................... 45
9.2
Messages and instructions on the display................................................. 46
9.3
Acknowledge the message........................................................................ 46
9.4
Malfunction messages ............................................................................... 47
9.5
Acknowledge malfunction message .......................................................... 48
10
Decommissioning and disposal ................................................................................. 48
11
General Information ..................................................................................................... 49
11.1
Liability limitation........................................................................................ 49
11.2
Copyright.................................................................................................... 49
11.3
Scope of delivery ....................................................................................... 49
11.4
Spare parts ................................................................................................ 50
11.5
Customer service ....................................................................................... 50
12
Setting value ................................................................................................................. 51
12.1
Setting value Sauna................................................................................... 51
12.2
Setting value Sauna with humidity............................................................. 51
12.3
Setting value Infrared................................................................................. 51
13
Declaration of Conformity ........................................................................................... 51
Index ...................................................................................................................................... 52
Notes: .................................................................................................................................... 54

Safety
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 5
1 Safety
1.1 Explanations of symbols
Warnings Warnings in this operating manual are indicated through symbols. The instructions are
introduced through signal words, which express the degree of danger.
Follow these instructions strictly and take care to avoid accidents, personal injuries and
property damage.
DANGER!
…indicates an imminent dangerous situation, which could lead to loss
of life or cause serious injuries if not avoided.
WARNING!
…indicates a possible dangerous situation, which can be fatal or cause
serious injuries if not avoided.
CAUTION!
…indicates a possible dangerous situation, which could lead to small or
slight injuries if not avoided.
ATTENTION!
…indicates a possible dangerous situation, which could lead to property
damage if not avoided.
Tips and
recommen-
dations
NOTE!
…highlights useful tips and recommendations as well as information for
an efficient and smooth operation.

Safety
6 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
1.2 Demands on the operator and technicians
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the appli-
ance. Cleaning and user maintenance shall not be made by children without supervi-
sion.
The operating instructions are to be read carefully before switching on the unit! To en-
sure safe operation and safe working practices you must comply with all the given
safety and handling instructions.
If you have any doubts, please contact your customer service.
Inadequate
qualifications
WARNING!
Danger caused by inadequate qualifications!
Improper handling could lead to considerable personal injuries and
damages to property.
Therefore:
The assembly, installation, commissioning, troubleshooting, mainte-
nance and repair work should be carried out only by qualified persons
unless otherwise mentioned.
1.3 Intended use
The FASEL Sauna controls of the series FCU4000, FCU4200 and FCU4400 are solely
intended for operating and controlling saunas and saunas with humidity cabins depend-
ing on the model. The control units are approved for private and commercial use.
Intended
use
CAUTION!
Danger caused by improper use!
Using the Sauna control for purposes other than the intended use could
lead to dangerous situations.
Therefore:
– Use the Sauna control only for the intended purpose.
– Operate the Sauna control only within the permissible ambient tem-
perature and humidity range. →See page 9.
– All the information in the operating and installation manual are to be
strictly followed.
– When the Sauna control is not in use, then switch off the main switch
(230V) or the fuses.
– Before switching on the Sauna control, make sure that nothing is on
the oven.
Any damage claims which arise due to improper use are excluded. Only the user is re-
sponsible for damages caused by improper use.

Safety
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 7
1.4 Changes and modifications
Changes and modifications to the control unit or to the installation could lead to unpre-
dictable dangers.
The written approval of the manufacturer must be obtained before making any technical
changes and enhancements to the Sauna control.
1.5 Operational safety and special dangers
Pay attention to the safety and warning notes in the following chapters of this manual to
minimize health hazards and to avoid dangerous situations.
The following instructions are to be adhered to for your own safety and the safety
of the unit:
Electric poten-
tial
DANGER!
Danger to life due to electric potential!
Contact with live components can be fatal.
Damage of the insulation of the individual components can be danger-
ous to life.
Therefore:
– For switching off the mains, the power supply cable must be
equipped with a fuse with a contact opening width corresponding to
the requirements of the excess voltage category III for total discon-
nection.
– Disconnect the unit from the mains before carrying out any work on
it (switch off the fuse in the distribution box) and secure against re-
starting. Check for zero potential. The control device should be dis-
connected from the mains before opening the casing.
– In case of damage to the insulation, switch off the power supply im-
mediately and carry out the repair.
– Work on electrical unit should be carried out by certified electricians
only.
– Never bypass fuses or switch them off.
– While replacing fuses, pay attention to correct current specifications.
– Keep moisture away from live components, since it can lead to short
circuit.
WARNING!
If a short circuit occurs in a 230V/400V load, the relay contact can
be welded by the high short-circuit current. Is turned on before
removing the short circuit, the safety relay can be also welded.
This can lead to the continuous operation of the load. Turn off the
circuit breaker in the junction box. Send the unit back to the fac-
tory for check/repair.

Safety
8 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
Improper
operation
WARNING!
Improper operation can result in serious injuries!
Therefore:
– read and note the operating manual.
1.6 Information on the operating and installation manual
An operating manual as well as an installation manual are available for the FASEL con-
trol unit.
The operating manual is meant for the user and gives important instructions for handling
the FASEL control unit.
The installation manual describes the assembly, installation, commissioning, rectifica-
tion of defects and repair and is provided exclusively for the technical personnel.
To ensure safe operation and working practices, all the prescribed safety instructions
and guidelines have to be followed.
Furthermore, the local accident prevention regulations and general safety regulations
applicable for the fields of use of the control unit are to be adhered to.
The operating manual must be read carefully before switching on the device. The oper-
ating manual as well as the installation manual are an integral part of the product and
must be kept in the immediate vicinity of the control unit so that they are always acces-
sible.
The number of available connections and functions depends on the version of the de-
vice. The keys and the display text can be customized depending on the particular
model and can differ from the figure shown on the first page.
If you pass on the control unit to a third party, make sure you hand over also the operat-
ing and installation manual.
Components from other suppliers have their own operating manuals, safety regulations
and guidelines, which must be followed as well.

Identification
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 9
2 Identification
2.1 Nameplate
The nameplate is located on the control unit on the left side:
2
1
8
5
3
4
7
6
Art Nr
Spg.:
Geräte Nr.: RoHS
conform
9
10 11
12
Fig.1 Control unit nameplate
1 Type designation
2 Company logo
3 Article number
4 Voltage and max. power
5 Device number
6 Barcode
7 article number
8 Barcode article number
9 VDE mark (for devices that are approved by VDE)
10 RoHS marking
11 CE mark
12 Protection category
3 Technical Data:
Label Type
Series FCU2000 Series FCU3000 Series FCU4000
Ambient temperature 0 to +40 °C
Rel. humidity max. 80 % r.H., non condensing
Table 1: Technical Data

Design and function
10 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
4 Design and function
4.1 Function
Depending on the model, the control unit is suitable for the following modes:
Sauna
Sauna with humidity
Infrared
4.1.1 Sauna
In the "Sauna" mode, the cabin is heated to the desired temperature (set point tempera-
ture) using an oven. In order then to maintain the desired temperature in the cabin, the
control unit switches the heater on and off.
As long as the heater heats, the status display shows "Heater" and the display shows
"Heat-up phase". Once the desired temperature is reached, this message disappears.
The cabin is ready for use.
4.1.2 Sauna with humidity (only FCUx200 and FCUx400)
In the "Sauna with humidity" mode, the cabin is heated to the desired temperature (set
point temperature) using an oven. In addition, the desired humidity (set point humidity)
is generated using an evaporator.
As long as the heater heats, the status display shows "Heater". As long as the evapora-
tor blows "steam" into the cabin, the status display shows "Evaporator".
Control unit with humidity control (with humidistat)
For these control units, the evaporator is controlled by the connected humidistat.
Control unit with time-controlled humidity (without humidistat)
In these control units, the evaporator is time-controlled. The amount of steam is ad-
justed by a numerical value from 1 to 9. If set to "1", steam is blown for a short time into
the cabin. If set to "9", the evaporator runs continuously and produces the maximum
amount of steam.
4.1.3 Infrared (only FCUx400)
For the "infrared" mode, the cabin is heated to the desired temperature by one or more
heat sources (set point temperature). The heat sources can be mounted on the wall or
in the wall. As long as the heat sources are working, the status display "infrared heating
system" lights up.
In addition a base temperature can be adjusted. The sauna oven heats as soon as this
temperature falls below. If this base temperature is reached, the sauna oven turns off.

Design and function
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 11
4.2 Operating and display elements
4.2.1 FCU4x00 design and FCU4x00 design glass
Fig. 2: Operation FCU4x00 design and FCU4x00 design glass view
1 Status display "Heater"
2 Status display "Evaporator"
3 Status display "Drying function”
4 Status display "Infrared heating system"
5 key "Sauna mode"
6 key "Sauna mode with humidity"
(only FCUx200 and FCUx400)
7 key "Infrared mode" (only FCUx400)
8 Control unit ON (only design)
9 Control unit OFF (only design)
10 symbol "Set temperature"
11 symbol "Set humidity "
12 symbol "Set remaining or heating time"
13 symbol “Set start time"
14 Display
15 key "Cabin light"
16 key “Fan"
17 key "Basic settings"
18 keys for navigation
19 Cleaning light OFF (only design)
20 Cleaning light ON (only design)

Design and function
12 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
4.2.2 Control keys Sauna control
The sauna control is equipped with the following control keys:
Key Description
key "Sauna mode"
Depending on the status of the green lamp, the "Sauna mode" key has different func-
tions.
Status lamp next to the key Meaning
Does not light up Mode is not selected.
The lamp flashes after pressing the "Sauna mode"
key.
Flashes Mode can be adjusted.
Control unit can be turned off using the "Control unit
OFF" switch.
The lamp lights up after pressing the "Sauna mode"
key.
Lights up "Sauna" mode is turned on.
The lamp flashes after pressing the "Sauna mode"
key.
key "Sauna mode with humidity" (only FCUx200 and FCUx400)
Depending on the status of the green lamp, the "Sauna mode with humidity" key has
different functions.
Status lamp next to the key Meaning
Does not light up Mode is not selected.
The lamp flashes after pressing the "Sauna mode
with humidity" key.
Flashes Mode can be adjusted.
Control unit can be turned off using the "Control unit
OFF" switch.
The lamp lights up after pressing the "Sauna mode
with humidity" key.
Lights up "Sauna with humidity" mode is turned on.
After pressing the "Sauna with humidity mode" key,
the drying function starts (if this mode was active for
at least 10 minutes). The 'Drying function' lamp
lights up.
After pressing the "Sauna with humidity mode" key
again, the drying function stops. An error message
appears if the drying temperature was not reached.

Design and function
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 13
Key Description
key "Infrared mode" (only FCUx400)
Depending on the status of the green lamp, the "Infrared mode" key has different func-
tions.
Status lamp next to the key Meaning
Does not light up Mode is not selected.
The lamp flashes after pressing the "Infrared mode"
key.
Flashes Mode can be adjusted.
Control unit can be turned off using the "Control unit
OFF" switch.
The lamp lights up after pressing the "Infrared
mode" key.
Lights up "Infrared" mode is on.
The lamp flashes after pressing the "Infrared mode"
key.
Special function (only FCUx000 and FCUx200)
If this function is available, use the "Infrared" key to adjust the infusion automat. After
the key has been pressed, the oven heats to the maximum temperature (max. 110°C).
When the adjusted time is over, the oven is controlling back to the adjusted set point
value. When the key is pressed or during the infusion time, on the display and on the
cabin interior display appears the message "Hot".
key "Cabin light"
Turn cabin light on and off. By pressing the key, the light is turned on or off and the
menu for adjusting the brightness is automatically displayed.
When special function light "LIS" is activated, then the light output is only active as long
as the light button is pressed. External dimmer can be controlled with this function, the
internal dimmer function is turned off.
key "Fan"
Turn the fan on and off. By pressing the key, the fan is turned on or off and the menu
for adjusting the fan speed is automatically displayed.
key "Basics menu settings"
Call "Basic settings menu".
Navigate upwards within the menu.
Navigate one line upwards in the display.
Increase the value by one.
Select option
Navigate downwards within the menu.
Navigate one line downwards in the display.
Reduce the value by one.
Select option

Design and function
14 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
Key Description
Change mode ON: (the green lamp next to navigation keys lights up): Move cursor
to the left.
Change mode OFF: (the green lamp next to navigation keys does not light up): Go
back to the parent menu.
Change mode ON: (the green lamp next to navigation keys lights up): Move cursor
to the right.
Change mode OFF: (the green lamp next to navigation keys does not light up): Call
sub-menu.
Call sub-menu.
Turn on change mode. Digit flashes.
Accept value (and go back into the parent menu).
Keys "Cleaning light OFF" and "Cleaning light ON"
(only FCU4x00 and FCU4x00 design, not for FCU4x00 design glass)
Use these keys to turn the cleaning light on and off. The control unit need not be turned
on.
Keys "Control unit mains OFF" and "Control unit mains ON"
(only FCU4x00 and FCU4x00 design)
Turn the control unit mains on and off.
Key "Control unit standby OFF" and "Control unit standby ON"
(only FCU4x00 design glass)
Turn the control unit standby on and off.
To prevent uncontrolled switching on and off, when cleaning the keyboard, the con-
trol is automatically after two minutes in the off-state. In this state, only the LED of
the Standby-Key is lighting. To restart or start a mode, press for 0.5 – 1 second the
corresponding key. From Software-Version 5.25.
Table: 2 Control keys Sauna control

Design and function
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 15
4.2.3 Explanation of the display FCU2x00
Fig. 3: Explanation of the FCU2xxx display
1-8 indicates which symbol or status display is currently enabled.
9 Colour wheel indicates whether colour light option is available.
10 Auto / manual
11-14 Colour lamps 1-4
15 Supply to the colour box
16 Thermometer is visible as soon as a value is shown on the bar graph.
17 The bar graph shows the actual and the set point temperature. In figure 4, the upper bar represents the set point
temperature (90 °C) to be reached. The lower bars represent the actual temperature (60 °C).
17

Design and function
16 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
4.3 Display symbols
The following symbols can appear in the display of the FCU4x00 control:
Display elements Description
Temperature
Humidity
Heating time
Remaining heating time
Time
Flavor
Colour light
Fan
Light
ON / OFF
Weekly timer
Display lighting
Display contrast
Start time
Infusion (Löyly)
Table: 3 Display symbols FCU4x00
The following symbols can appear in the display of the FCU2x00 and FCU3x00 control:
Display elements Description
Selection checkmark
0 / 1
Enter
Table: 4 Display symbols FCU2x00/FCU3x00

Operation
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 17
5 Operation
5.1 Safety and instructions
Electric
potential
DANGER!
Danger to life due to electric potential!
Touching live parts can cause immediate danger to life.
Therefore:
– Control unit should be opened only by authorised electricians.
– Electrical work on the machine should be carried out only by qualified
electricians.
Improper
operation
WARNING!
Improper operation can result in serious injuries!
Therefore:
– Carry out all the operating steps according to this operating manual.
Danger of fire
WARNING!
Danger of injury caused by fire!
Objects on the heater or in the vicinity of the heater can cause a fire
and thus result in injuries.
Therefore:
– Always keep the heater and the area around the heater free of ob-
jects.
Health
hazard
WARNING!
Danger of injury caused by covering the temperature sensor and /
or the humidistat!
Covering the temperature sensor and / or the humidistat could lead to
increased temperatures and humidity. These increased levels could
lead to health hazards or serious injuries.
Therefore:
– Do not cover the temperature sensor and humidistat.
– Ensure free circulation of air.

Operation
18 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
NOTE!
The temperature and humidity values displayed on the control unit may
vary from that displayed on the thermometers and hygrometers
mounted additionally in the cabin. This may be because of the following
reasons:
Depending on the cabin, temperatures differences of up to 60K and dif-
ferences in the relative humidity of up to 40% can occur from the floor to
ceiling or from the heater to the opposite wall.
Analogue instruments are slower to react than the electronic measure-
ment and display system used in the control unit.
5.2 Turn sauna control on and off
5.2.1 Turn sauna control on
Ensure that the heater, the surroundings and the sensors are free of objects.
1. Turn on the sauna control using the "Control unit ON" key. →See page 11, Fig. 2
2. The set point temperature and the set point humidity (if necessary) of the mode last
selected are displayed. The green lamp of the last selected mode flashes.
3. Select mode according to chapter.5.2.3
5.2.2 Turn sauna control off
PLEASE NOTE!
The electronic components can be damaged by repeated improper
turning off!
Therefore:
– Turn off the sauna control as described.
PLEASE NOTE!
Cabin damage for e.g. mould growth due to premature stopping of
the drying function!
After completion of the "sauna with humidity" mode, the cabin is auto-
matically dried for a certain time at a certain temperature. This drying
function is used to avoid cabin damage such as mould growth.
Therefore:
– Do not stop the drying function prematurely.
– The drying function may only be stopped if the cabin is subsequently
operated in "Sauna" mode.
– If the drying function is stopped accidentally, a message appears on
the display. Start the drying function again by following the instruc-
tions on the display.

Operation
Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09 19
A mode is selected. The corresponding green lamp lights up.
1. Press the key of the selected mode. The green lamp next to the key flashes.
2. The green lamp of the selected mode flashes. Turn off the sauna control using the
"Control unit OFF" key. →See page 11, Fig. 2
5.2.3 Select or start the mode
Mode
select or start
1. Turn on sauna control according to chapter 5.2.1.
2. The green lamp of the last selected mode flashes.
3. Press the key for the desired mode.
Key Description
Sauna mode
Sauna mode with humidity
(only FCUx200 and FCUx400)
Infrared mode
(only FCU3400 and FCU4400)
Table: 5 Mode control keys
4. If the green lamp of the selected mode flashes, press the key again. The desired
mode has been started only when the green lamp stops flashing.
5.3 Adjust modes
NOTE!
There are two menu navigations available for the control unit. All the
menus are displayed only in the "Professional" menu. These menus are
indicated accordingly in this chapter. If these menus are not displayed,
your control has been set to the "Small" menu.
→
Also see “options
menu”.
Furthermore, the control unit can be equipped with extension boards
like for e.g. for flover feeding. This requires additional menus, which are
indicated accordingly in this chapter. For information about the fittings of
your sauna control, please contact the installer or the dealer of your
sauna system.
The control unit is turned on.
1. Press the key (sauna mode), (Sauna with humidity mode) or (infrared
mode) if required. The lamp next to the key must flash or light up.
2. Following view is displayed:

Operation
20 Operating manual Sauna control FCU2x00/FCU3x00/FCU4x00 Version V 2.09
Fig. 4: "Sauna" view (example)
3. Press the key.
4. The symbol (adjust the temperature) lights up. →See page 22, chapter 5.3.3.
5. Press the key.
6. The symbol (adjust heating /
remaining heating time) lights up.
7. Depending on the status of the lamp next to the mode key, adjust the heating time
or the remaining heating time. →See page 22, chapter 5.3.3.
8. Press the key.
9. Menu option Professional: "Light brightness" view is displayed.
→See page 24, chapter Fig. 8.
10. Press the key.
11. Menu option "Professional": "Fan speed level" view is displayed.
→See page 25, Fig. 9.
12. Press the key.
13. Optional: "Adjust colour light mode" view is displayed.
→See page 27, Fig. 11.
14. Press the key.
15. Optional: "Options menu (flovor feed)" view is displayed.
→See page 30, Fig. 15.
16. Press the key. The "Sauna" view (Fig. 4) is displayed again.
NOTE!
If the key is not operated for a few seconds, the program automatically
switches back to the "main" view. (If the controller has a timer and it is
active, he switches into the timer menu.)
5.3.1 Adjust "Sauna" mode
In this mode there are no other settings.
Other manuals for FCU2000 Series
3
This manual suits for next models
7
Table of contents
Other Fasel Elektronik Control Panel manuals