Fasel Elektronik FCU2000 Series User manual

Technical changes and errors excepted, illustration similar
Operating manual
Steam bath control
Series FCU2000/FCU3000/FCU4000
Doc-ID: B_FCUxxxx-Steam_EN
Version: V 2.03

2 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
FASEL GmbH
Germany

Table of Contents
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 3
Table of Contents
1
Safety................................................................................................................................5
1.1
Explanations of symbols...............................................................................5
2.1
Demands on the operator and technicians...................................................5
1.2
Intended use .................................................................................................6
1.3
Changes and modifications ..........................................................................7
1.4
Operational safety and special dangers .......................................................7
2
Identification ....................................................................................................................8
2.1
Nameplate ....................................................................................................8
3
Technical Data:................................................................................................................8
4
Design and function........................................................................................................9
4.1
Function ........................................................................................................9
4.1.1
Steam ......................................................................................................9
4.1.2
Aroma ......................................................................................................9
4.1.3
Seat heating – (optional) .........................................................................9
4.2
Operating and display elements .................................................................10
4.2.1
FCUxxxx-Steam design and FCU-Steam design glass ........................10
4.2.2
Control keys steam bath control............................................................11
4.2.3
Explanation of the display .....................................................................13
4.3
Display symbols..........................................................................................14
5
Operation .......................................................................................................................15
5.1
Safety and instructions ...............................................................................15
5.2
Turn steam bath control on and off.............................................................16
5.2.1
Turn steam bath control on ...................................................................16
5.2.2
Turn steam bath control off ...................................................................16
5.2.3
Select or start the mode ........................................................................17
5.3
Adjust "Steam bath" mode..........................................................................17
5.4
Adjust the set point temperature, heating time, remaining heating time and
timer............................................................................................................18
5.4.1
Maximum allowed heating time.............................................................19
5.4.2
Maximum allowed heating time.............................................................20
5.5
Day timer ....................................................................................................20
5.5.1
Adjust the flavour feed...........................................................................21
5.6
Adjust the brightness of the cabin light (not for FCU2xxx) .........................22
5.7
Adjust the cabin fan speed (not for FCU2xxx)............................................22
5.8
Options menu .............................................................................................23
5.8.1
Adjust bench temperature – (optional) ..................................................23
5.8.2
RGB-LED brightness (only for FCU4xxx and menu "Pro") ...................23
5.8.3
Colour light mode (including parameter description).............................24
5.8.4
Colour light start (only for menu "Pro")..................................................26
6
"Basic settings" menu..................................................................................................28

Table of Contents
4 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
6.1
"Basic settings" - general ........................................................................... 28
6.1.1
Time and Weekday............................................................................... 28
6.1.2
Weekly timer ON/OFF (only for FCU4xxx) ........................................... 29
6.1.3
Program the weekly timer ..................................................................... 29
6.1.4
Select program (only for FCU4xxx) ...................................................... 31
6.1.5
Adjust display lighting (not for FCU2xxx).............................................. 32
6.1.6
Adjust display contrast (only for FCU4xxx)........................................... 32
6.1.7
Light settings (only for menu "Pro") ...................................................... 33
6.1.8
Fan settings (only for menu "Pro")........................................................ 34
6.2
"Basic settings" for options ........................................................................ 36
6.2.1
RGB-LED settings (only for FCU4xxx and menu "Pro")....................... 36
6.2.2
Colour light automatic (only for menu "Pro") ........................................ 37
6.2.3
Versions and data (only for menu "Pro") .............................................. 39
7
Options menu ............................................................................................................... 40
7.1
Small/professional...................................................................................... 40
7.2
Parental/Keypad lock ................................................................................. 40
7.3
Select language ......................................................................................... 40
8
Maintenance.................................................................................................................. 41
8.1
Cleaning..................................................................................................... 41
9
Malfunctions ................................................................................................................. 41
10
General Information ..................................................................................................... 41
10.1
Liability limitation........................................................................................ 41
10.2
Copyright.................................................................................................... 42
10.3
Scope of delivery ....................................................................................... 42
10.4
Spare parts ................................................................................................ 42
10.5
Customer service ....................................................................................... 42
10.6 43
10.7
Safety and instructions............................................................................... 43
10.8
Malfunction messages ............................................................................... 43
10.9
Acknowledge malfunction message .......................................................... 44
11
Decommissioning and disposal ................................................................................. 45
12
Setting value ................................................................................................................. 45
12.1
Setting value Steam bath........................................................................... 45
13
Declaration of Conformity ........................................................................................... 45
Index ...................................................................................................................................... 46

Safety
5 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
1 Safety
1.1 Explanations of symbols
Warnings Warnings in this operating manual are indicated through symbols. The instructions are
introduced through signal words, which express the degree of danger.
Follow these instructions strictly and take care to avoid accidents, personal injuries and
property damage.
DANGER!
…indicates an imminent dangerous situation, which could lead to loss of
life or cause serious injuries if not avoided.
WARNING!
…indicates a possible dangerous situation, which can be fatal or cause se-
rious injuries if not avoided.
CAUTION!
…indicates a possible dangerous situation, which could lead to small or
slight injuries if not avoided.
ATTENTION!
…indicates a possible dangerous situation, which could lead to property
damage if not avoided.
2.1 Demands on the operator and technicians
No special skills are required to operate the control unit.
The operating manual does not generally take the following into account:
Persons (including children)

Safety
6 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
– their physical, sensory or mental abilities or
– Lack of experience and / or knowledge which prevent the safe use of the device
without supervision or instruction.
Children playing with the device.
The operating instructions are to be read carefully before switching on the unit! To en-
sure safe operation and safe working practices you must comply with all the given
safety and handling instructions.
If you have any doubts, please contact your customer service.
Inadequate
qualifications
WARNING!
Danger caused by inadequate qualifications!
Improper handling could lead to considerable personal injuries
and damages to property.
Therefore:
The assembly, installation, commissioning, troubleshooting, mainte-
nance and repair work should be carried out only by qualified persons
unless otherwise mentioned.
Tips and
recommen-
dations
NOTE!
…highlights useful tips and recommendations as well as information for an
efficient and smooth operation.
1.2 Intended use
The FASEL Steam bath controls of the series FCU2000, FCU3000 and FCU4000 are
solely intended for operating and controlling steam bath cabins. The control units are
approved for private and commercial use.
Intended
use
CAUTION!
Danger caused by improper use!
Using the steam bath control for purposes other than the intended use
could lead to dangerous situations.
Therefore:
– Use the steam bath control only for the intended purpose.
– Operate the steam bath control only within the permissible ambient
temperature and humidity range. →See page 8.
– All the information in the operating and installation manual are to be
strictly followed.
– When not in use switch off the main switch (230V) or fuses
– Before switching on the steam bath control make sure that no ob-
jects are placed on the oven.

Safety
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 7
Any damage claims which arise due to improper use are excluded. Only the user is re-
sponsible for damages caused by improper use.
1.3 Changes and modifications
Changes and modifications to the steam bath control or to the installation could lead to
unexpected dangers.
The written approval of the manufacturer must be obtained before making any technical
changes and enhancements to the steam bath control.
1.4 Operational safety and special dangers
Pay attention to the safety and warning notes in the following chapters of this manual to
minimize health hazards and to avoid dangerous situations.
The following instructions are to be adhered for your own safety and the safety of
the unit:
Electric poten-
tial
DANGER!
Danger to life due to electric potential!
Contact with live components can be fatal.
Damage of the insulation of the individual components can be dange-
rous to life.
Therefore:
– For switching off the mains, the power supply cable must be
equipped with a fuse with a contact opening width corresponding to
the requirements of the excess voltage category III for total discon-
nection.
– Disconnect the unit from the mains before carrying out any work on
it (switch off the fuse in the distribution box) and secure against re-
starting. Check for zero potential. The control device should be dis-
connected from the mains before opening the casing.
– In case of damage to the insulation, switch off the power supply im-
mediately and carry out the repair.
– Work on electrical unit should be carried out by certified electricians
only.
– Never bypass fuses or put them out of operation.
– While replacing fuses, pay attention to correct current specifications.
– Keep moisture away from live components, since it can lead to short
circuit.
WARNING!
If a short circuit occurs in a 230V/400V load, the relay contact can
be welded by the high short-circuit current. Is turned on before
removing the short circuit, the safety relay can be also welded.
This can lead to the continuous operation of the load. Turn off the
circuit breaker in the distribuition box. Send the unit back to the
factory for check/repair.

Identification
8 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
Improper
operation
WARNING!
Improper operation can result in serious injuries!
Therefore:
– read and note the operating manual.
2 Identification
2.1 Nameplate
The nameplate is located on the control unit on the left side:
2
1
8
5
3
4
7
6
Art Nr
Spg.:
Geräte Nr.: RoHS
conform
9
10 11
12
Fig.1 Control unit nameplate
1 Type designation
2 Company logo
3 Article number
4 Voltage and max. power
5 Device number
6 Barcode
7 Article number
8 Barcode article number
9 VDE mark (for devices that are approved by VDE)
10 RoHS marking
11 CE mark
12 Protection category
3 Technical Data:
Label Type
Series FCU2000 Series FCU3000 Series FCU4000
Ambient temperature 0°C to +40 °C
With protective coating -20°C to +40°C
Rel. humidity max. 80 % r.H., non condensing
Table 1: Technical Data

Design and function
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 9
4 Design and function
4.1 Function
Depending on the model, the control unit is suitable for the following modes:
Steam
Aroma
Seat heating (optional)
4.1.1 Steam
In the "Steam" mode, the cabin is heated to the desired temperature (set point tempera-
ture) with the help of a vaporiser. In order to maintain the desired temperature in the
cabin, the control unit switches the vaporiser on and off.
As long as the vaporiser blows “steam” into the cabin, the status display "Steam gen-
erator" lights and the display shows "Heat-up phase". Once the desired temperature is
reached, this message disappears. The cabin is ready for use.
4.1.2 Aroma
With the help of the "Aroma" function, you can select the time intervals and the duration,
for which aromas will be blown into the cabin (blowing time). As long as aromas are
blown, the status display shows "Aroma".
4.1.3 Seat heating – (optional)
In the "Seat heating" function, a steam bath bench with seat heating is additionally
heated.
For this purpose, the "bench temperature", to which the bench should be heated, can be
adjusted. As long as the seat heating is working, the status display "Seat heating" lights
up.

Design and function
10 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
4.2 Operating and display elements
4.2.1 FCUxxxx-Steam design and FCU-Steam design glass
Fig. 2: View: Operation FCUxxxx-Steam design and FCUxxxx Steam design glass
1 Status display "Steam generator"
2 Status display "Aroma"
3 Status display "Seat heating"
5 "Steam bath" key
6 "Aroma" key
7 "Bench" key
8 Control unit ON (only design)
9 Control unit OFF (only design)
10 "Set temperature" symbol
11 "Set flavour" symbol
12 "Set or remaining heating time" symbol
13 "Set start time" symbol”
14 Display
15 Cabin light" key
16 "Fan" key"
17 "Basic settings" key
18 Navigation keys
19 Cleaning light OFF (only design)
20 Cleaning light ON (only design)

Design and function
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 11
4.2.2 Control keys steam bath control
The steam bath control is equipped with the following control keys:
Key Description
"Steam" key
Depending on the status of the green lamp, the "Steam" key has different functions.
Status lamp next to the key Meaning
Flashes Bathing mode “Steam” not active.
Control unit can be turned off using the "Control unit
OFF" switch.
Lights up "Steam" mode is turned on.
If the option “Seat Heater” is available, then the
“Seat Heater” is enabled simultaneously and ad-
justed to the desired temperature.
"Aroma" key
By pressing the "Aroma" key, the lamp can be switched on and off
Status lamp next to the key Meaning
Does not light up Main menu is displayed.
Lights up “Aroma” menu is activated and the interval setting
pause/spray can be changed.
For hose refilling, the button must pressed longer
than 2s. Then the flavour pump runs continuously
as long as the button is pressed.
"Bench" key (optional
By pressing the " Bench " key, the lamp can be switched on and off.
Status lamp next to the key Meaning
Does not light up The "Seat Heater" is turned off.
Lights up The “Seat Heater” is enabled and controls to the
desired temperature.
"Cabin light" key
Turn cabin light on and off. By pressing the key, the light is turned on or off and the
menu for adjusting the brightness is automatically displayed.
If the special function "LIS" is enabled, the light is enabled only as long as the Light key
is pressed. With this function, external dimmers can be controlled, the internal dimmer
function is switched off.
"Fan speed" key
Turn the fan on and off. By pressing the key, the fan is turned on or off and the menu
for adjusting the fan speed is automatically displayed.

Design and function
12 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
Key Description
"Basics menu settings" key
Call "Basic settings menu".
Navigate upwards within the menu.
Navigate one line upwards in the display.
Increase the value by one.
Select option
Navigate downwards within the menu.
Navigate one line downwards in the display.
Reduce the value by one.
Select option
Change mode ON: (the green lamp next to navigation keys lights up): Move cursor
to the left.
Change mode OFF: (the green lamp next to navigation keys does not light up): Go
back to the parent menu.
Change mode ON: (the green lamp next to navigation keys lights up): Move cursor
to the right.
Change mode OFF: (the green lamp next to navigation keys does not light up):
Call sub-menu.
Call sub-menu.
Turn on change mode. Digit flashes.
Accept value (and go back into the parent menu).
Keys "Cleaning light OFF" and "Cleaning light ON"
(only FCUxxxx Steam and FCUxxxx-Steam design, not for FCUxxxx Steam design
glass)
Use these keys to turn the cleaning light on and off. The control unit need not be
turned on.
Keys "Control unit OFF" and "Control unit ON"
(only FCUxxxx-Steam and FCUxxxx-Steam design)
Turn the power line for the control device on and offf.
"Activate/ deactivate control standby " key
(only FCU4x00 design glass)
Turn the control unit standby on and off.
To prevent uncontrolled switching on and off, when cleaning the keyboard, the con-
trol is automatically after two minutes in the off-state. In this state, only the LED of
the Standby-Key is lighting. To restart or start a mode, press for 0.5 – 1 second the
corresponding key. From Software-Version 5.25.
Table: 2 Control keys steam bath control

Design and function
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 13
4.2.3 Explanation of the display
Fig. 3: Explanation of the FCU2xxx display
1-8 indicates which symbol or status display is currently enabled.
9 Colour wheel indicates whether colour light option is available.
10 Auto / manual
11-14 Colour lamps 1-4
15 Supply to the colour box
16 Thermometer is visible as soon as a value is shown on the bar graph.
17 The bar graph shows the actual and the set point temperature. In figure 4, the upper bar represents the set point
temperature (90 °C) to be reached. The lower bars represent the actual temperature (60 °C).
17

Design and function
14 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
4.3 Display symbols
The following symbols can appear in the display of the FCU4x00 control:
Display elements Description
Temperature
Aroma
Heating time
Remaining heating time
Start time
Light
Fan
Colour light
Bench temperature
Time
Weekly timer
Display lighting
Display contrast
ON / OFF
Table: 3 Display symbols
The following symbols can appear in the display of the FCU2x00 and FCU3x00 control:
Display elements Description
Selection checkmark
0 / 1
Enter
Table: 4 Display symbols FCU2x00/FCU3x00

Operation
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 15
5 Operation
5.1 Safety and instructions
Electric
potential
DANGER!
Danger to life due to electric potential!
Touching live parts can cause immediate danger to life.
Therefore:
– Control unit should be opened only by authorised electricians.
– Electrical work on the machine should be carried out only by qualified
electricians.
Improper
operation
WARNING!
Improper operation can result in serious injuries!
Therefore:
– Carry out all the operating steps according to this operating manual.
Danger of fire
WARNING!
Danger of injury caused by fire!
Objects on the heater or in the vicinity of the heater can cause a fire
and thus result in injuries.
Therefore:
– Always keep the heater and the area around the heater free of ob-
jects.
Health
hazard
WARNING!
Danger of injury caused by covering the temperature sensor and /
or the humidistat!
Covering the temperature sensor and / or the humidistat could lead to
increased temperatures and humidity. These increased levels could
lead to health hazards or serious injuries.
Therefore:
– Do not cover the temperature sensor and humidistat.
– Ensure free circulation of air.

Operation
16 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
NOTE!
The temperature values displayed on additional thermometers in the
cabin can deviate from the displayed values on the control. This could
be due to the following reasons:
Depending on the cabin, the temperature differences from the floor to
the ceiling can be considerably.
Instruments with indicator needles react slower than electrical measur-
ing and display systems used for the control.
5.2 Turn steam bath control on and off
5.2.1 Turn steam bath control on
Ensure that the steam inlet, the surrounding area and the sensors are free of objects.
1. Turn on the steam bath control using the "Control unit ON" key. →See page 14,
Fig. 2
2. The set point temperature, the aroma settings and the heating time are displayed.
The green lamp of the “Steam bath” key flashes.
3. Start mode according to chapter.5.2.3.
5.2.2 Turn steam bath control off
PLEASE NOTE!
The electronic components can be damaged by repeated improper
turning off!
Therefore:
– Turn off the steam bath control as described.
PLEASE NOTE!
Cabin damage for e.g. mould growth due to premature stopping of
the fan after-run time!
In order to remove the moisture in the steam bath room, you can set a
fan after-run time in the basic setting menu after completion of the
steam bath programme. This ensures that the fan is running for the ex-
tra time you have set after the steam bath operation. This function is
used to avoid cabin damage such as mould growth.
Therefore:
– Do not stop the fan after-run time prematurely.
The "Steam bath" mode is selected. The corresponding green lamp lights up.
1. Press the key of the „steam bath“ mode. The green lamp next to the key flashes.
2. The green lamp of the „steam bath“ mode flashes. Turn off the steam bath control
using the "Control unit OFF" key. →See page 10, Fig. 2

Operation
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 17
5.2.3 Select or start the mode
Mode
select
1. Turn on steam bath control according to chapter 5.2.1.
2. The green lamp of the "Steam bath" mode flashes.
3. Press the key for the "Steam bath" mode. The lamp flashes. Mode was started.
Key Description
Steam bath mode
Table: 5 Mode control keys
5.3 Adjust "Steam bath" mode
NOTE!
There are two menu navigations available for the control unit. All the
menus are displayed only in the "Professional" menu. These menus are
indicated accordingly in this chapter. If these menus are not displayed,
your control has been set to the "Small" menu
→
See also page 39.
Furthermore, the control unit can be equipped with extension boards
like for e.g. for colour light. This requires additional menus, which are
indicated accordingly in this chapter. For information about the fittings of
your steam bath control, please contact the installer or the dealer of
your steam bath system.
The control unit is turned on.
1. The lamp next to the
"Steam bath" key must flash or light up.
2. Following view is displayed:
Fig. 4: "Steam bath" view (example)
3. Press the key.
4. The symbol (adjust the temperature) lights up. →See page 18, chapter 5.4.
5. Press the key.
6. The symbol
(Adjust aroma) lights up. →See page 21, chapter 5.5.1.
7. Press the key

Operation
18 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
8. The symbol (adjust heating /
remaining heating time) lights up.
9. Depending on the status of the lamp next to the mode key, adjust the heating time
or the remaining heating time. →See page 18, chapter 5.4.
10. Press the key.
11. Menu option Professional: "Light brightness" view is displayed.
→See page 22, chapter 5.6.
12. Press the key.
13. Menu option "Professional": "Fan speed level view is displayed.
→See page 22, chapter 5.7.
14. Press the key.
15. Optional: The "Bench temperature" view is displayed.
→See page 23, chapter 5.8.1.
16. Press the key.
17. Optional: "Adjust colour light mode" view is displayed.
→See page 25, Fig. 11.
18. Press the key. The "Steam bath" view (Fig. 4) is displayed again.
NOTE!
If the key is not operated for a few seconds, the program automatically
switches back to the "main" view. (If the controller has a timer and it is
active, he switches into the timer menu.)
5.4 Adjust the set point temperature, heating time, remaining heating time
and timer
The following example describes how to adjust the set point temperature.
The heating time, the remaining heating time and the timer are adjusted similarly.
Note the following points:
If you want to adjust the set point temperature, heating time, remaining heating time
or the timer, the corresponding symbol must light up at the right of the display. That
is, the symbol "Temperature" should light up if you want to adjust the temperature.
The heating time and the remaining heating time use the same symbol. The value
which you adjust depends on the status of the lamp next to the mode key.

Operation
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000 B_FCUxxxx-Steam_EN / Version V 2.03 19
Heating time Remaining heating time
The heating time is the operating time for
the "Steam bath" mode.
The remaining heating time is the re-
maining time when the "Steam bath"
mode is turned on. The remaining heat-
ing time is reduced automatically.
The heating time can be adjusted if the
lamp next to the "Steam bath" mode key
flashes.
The remaining heating time can be ad-
justed if the lamp next to the "Steam
bath" mode key lights up.
The modified remaining heating time
does not change the programmed heat-
ing time.
Table: 6 Heating time / remaining heating time
The timer may be enabled or disabled depending on the setting. In the series
FCU2000-Steam and FCU3000-Steam, weekly timer is not available.
1. The "Steam bath" (Fig. 4) is displayed.
2. Press the key till the symbol (adjust temperature) lights up.
3. Press the key.
4. Following view is displayed:
Fig. 5: "Change values" view (example)
5. Press the key. Last digit flashes.
6. Adjust the desired value:
Press the key: Reduce value.
Press the key: Increase value.
Note!
After the digit "9" or "0", the higher digit of the temperature value is changed. That
is "40" is displayed after "39".
You can also select the higher digit using the key or key and then change.
7. Press the key. The "Steam bath" view is displayed again.
5.4.1 Maximum allowed heating time
After starting a mode, the remaining heating time is displayed in place of the full heating
time. The heating time can be changed only in standby mode.

Operation
20 Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
The EN 60335-2-53 "Specific requirements for sauna heating devices" allows the follo-
wing maximum heating times:
Max. heating time Description
more than 12 hours Public cabins which are supervised by trained
personnel.
max. 12 hours Hotels, apartment blocks, etc.
max. 6 hours All other cabins / private households
Table: 7 Maximum heating time
The control devices are delivered with a maximum adjustable heating time of 6 hours. If
you need heating times exceeding 6 hours, please contact the installer or the dealer of
your sauna system.
5.4.2 Maximum allowed heating time
After starting a mode, the remaining heating time is displayed in place of the full heating
time. The heating time can be changed only in standby mode.
The EN 60335-2-53 "Specific requirements for sauna heating devices" allows the follo-
wing maximum heating times:
Max. heating time Description
more than 12 hours Public cabins which are supervised by trained
personnel.
max. 12 hours Hotels, apartment blocks, etc.
max. 6 hours All other cabins / private households
Table: 8 Maximum heating time
The control devices are delivered with a maximum adjustable heating time of 6 hours. If
you need heating times exceeding 6 hours, please contact the installer or the dealer of
your sauna system.
5.5 Day timer
NOTE!
The timer may not be enabled without additional safety measures by your
service technician and therefore it can be disabled (the menu does not
appear).
1. Press the -key until the symbol (adjust timer) lights up.
2. Adjust desired time (see above)
3. Press the -key to adjust the value.
4. Press the mode-key (flashes)
5. Symbol flashes.
6. For turning off the timer, please turn off the control unit or press mode-key once for
starting and once again for stopping.
Other manuals for FCU2000 Series
3
This manual suits for next models
2
Table of contents
Other Fasel Elektronik Control Unit manuals
Popular Control Unit manuals by other brands

NIPPON VALVE CONTROLS
NIPPON VALVE CONTROLS Vpro WT9 2TG0 Series instruction manual

WAGO
WAGO 750-469/040-000 manual

Stübbe
Stübbe C 110 Series operating manual

oventrop
oventrop Hydrocontrol VFC Installation and operating instructions

Spectrum Controls
Spectrum Controls Micro800 2080sc-IF4U install guide

NXP Semiconductors
NXP Semiconductors PMSMMCXN9XXEVK user guide