Feig Electronic ISC.ANT.UMUX User manual

INSTALLATION
final – public (B)
2013-02-07 – M71100-3e-ID-B.docx
ID ISC.ANT.UMUX
8-times UHF Antenna Multiplexer

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 2 of 19 M71100-3e-ID-B.docx
Note
Copyright 2013 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
Use Exclusion in Transportation Market: Devices which are subject of this document may NOT be sold,
used, leased, offer for sale, or otherwise transferred, exported, and imported by anyone in the Transportation
Market. “Transportation Market” means (i) Electronic Toll and Traffic Management (ETTM), (ii) Public Sector
Vehicle Registration, Inspection and Licensing Programs, (iii) Railroad Locomotive and Wagon tracking, (iv)
airport based ground transportation management systems (GTMS) and taxi dispatch, (v) revenue based
parking, and (vi) vehicle initiated mobile payment applications, where the RFID sticker/tag is initially attached
to the vehicle but not incorporated at the point of vehicle manufacture.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu-
ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
OBID®and OBID i-scan®are registered trademarks of FEIG ELECTRONIC GmbH.

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 3 of 19 M71100-3e-ID-B.docx
General information's regarding this document
•The sign "" indicates extensions or changes of this manual compared with the former issue.
•If bits within one byte are filled with "-", these bit spaces are reserved for future extensions or
for internal testing- and manufacturing-functions. These bit spaces must not be changed, as this
may cause faulty operation of the reader.
•The following figure formats are used:
0...9: for decimal figures
0x00...0xFF: for hexadecimal figures,
b0...1 for binary figures.
•The hexadecimal value in brackets "[ ]" marks a control byte (command).

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 4 of 19 M71100-3e-ID-B.docx
Contents
1. Safety Instructions / Warning - Read before start-up ! 6
2. Performance Features oft he ID ISC.ANT.UMUX 8 times UHF Antenna Multiplexer 7
2.1. Performance Features.......................................................................................................7
2.2. Scope of Delivery ..............................................................................................................7
2.3. Available Multiplexer Types..............................................................................................7
3. Wiring and Installation 8
3.1. Dimensions........................................................................................................................8
3.2. Terminals and Jacks .........................................................................................................9
3.2.1. Supply Voltage.............................................................................................................9
3.2.2. Reader Connection - IN .............................................................................................10
3.2.3. Antenna Connection – OUT 1 - 8...............................................................................10
3.2.4. Boot Loader Interface – X2 ........................................................................................10
4. Operating and Display Elements 11
4.1. LEDs.................................................................................................................................11
4.2. Reset Button T1...............................................................................................................11
4.3. DIP Switch S1 ..................................................................................................................12
4.3.1. Hardware Address setting..........................................................................................12
4.3.2. DC Coupling ..............................................................................................................12
5. Troubleshooting 13
6. Technical Data 14
7. Radio Approvals 16
7.1. Europe (CE)......................................................................................................................16
7.2. Declaration of Conformity (Directive 1999/5/EC - R&TTE)............................................17

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 5 of 19 M71100-3e-ID-B.docx
ANNEX 18
ANNEX A - Accessories.........................................................................................................18
ANNEX A1 – Wall Mount Kit ID ISC.MS.MR/PR-A...............................................................19

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 6 of 19 M71100-3e-ID-B.docx
1. Safety Instructions / Warning - Read before start-up !
•The device may only be used for the intended purpose designed by for the manufacturer.
•The operation manual should be conveniently kept available at all times for each user.
•Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
•The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
•Repairs may only be executed by the manufacturer.
•Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
•Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
•When working on devices the valid safety regulations must be observed.
•Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in
an immediate proximity of the device respective the antenna for some time.

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 7 of 19 M71100-3e-ID-B.docx
2. Performance Features oft he ID ISC.ANT.UMUX 8 times UHF Antenna Multiplexer
2.1. Performance Features
The ID ISC.ANT.UMUX 8x UHF antenna multiplexer is designed for switching RFID antennas hav-
ing an operating frequency of 860 MHz – 960 MHz. An ID ISC.ANT.UMUX allows multiple individ-
ual antennas to be operated with just a single reader antenna output.
It is possible to cascade several ID ISC.ANT.UMUX to increase the number of possible antenna
connections. Here the antenna multiplexers are addressed using DIP switch settings.
2.2. Scope of Delivery
The following components are included in the scope of delivery:
•1 x ID ISC.ANT.UMUX 8x UHF antenna multiplexer
•1 x Installation Guide
2.3. Available Multiplexer Types
The following Multiplexers are currently available:
Table 1: Multiplexer types
Multiplexer type
Description
ID ISC.ANT.UMUX-A UHF Multiplexer in IP30 case

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 8 of 19 M71100-3e-ID-B.docx
3. Wiring and Installation
3.1. Dimensions
The antenna multiplexer is designed for an indoor environment. It can be wall-mounted, in this
case the wall mounting kit should be ordered separately. (see ANNEX A - Accessories and ANNEX
A1 – Wall Mount Kit ID ISC.MS.MR/PR-A)
Figure 1: Enclosure (all dimensions in mm)

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 9 of 19 M71100-3e-ID-B.docx
3.2. Terminals and Jacks
Figure 2 shows the terminals, jacks, DIP switches and LED indicators.
Figure 2: Terminals, jacks and operating elements
3.2.1. Supply Voltage
The supply voltage is connected to X1 or directly to the Reader Connection IN. Configure the po-
larity for X1 as shown in Figure 2. The antenna multiplexer operates with a DC voltage of 12 V DC
to 24 V DC. In a configuration with cascaded multiplexers you could supply the connected multip-
lexers directly over the antenna cable. In this case only the first multiplexer has to be connect to an
power supply unit.
NOTE:
If connected to the UHF Long Range Reader ID ISC.LRU3500 the supply voltage for a mul-
tiplexer in the first cascade level could also be provided from the reader via the antenna
cable. The use of an additional external power supply is only necessary if several multip-
lexers should be cascaded after each other.
T1
S1
GND
VCC
X2
X1
IN
OUT1 OUT2 OUT3 OUT4
OUT8 OUT7 OUT6 OUT5 V1 V2 V3 V4

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 10 of 19 M71100-3e-ID-B.docx
3.2.2. Reader Connection - IN
The connection to a reader is made using coaxial cable to the SMA jack IN. The maximum
tightening torque of the SMA jack is 0,45 Nm (4.0 lbf in).
The transmitting power at reader connection IN must be at least 85 mW.
3.2.3. Antenna Connection – OUT 1 - 8
The antennas or further multiplexers are connected using coaxial cable to the SMA jacks OUT1-8.
The maximum tightening torque of the SMA jacks is 0,45 Nm (4.0 lbf in).
3.2.4. Boot Loader Interface – X2
To perform a firmware update you have to connect the update cable ID CAB.RS-B with X2 as
shown in Fig. 3. The tuning board must be powered through the antenna cable on IN or through
the terminal X1 as it is done in the normal operation mode. See also 3.2.1. Supply Voltage
Figure 3: Connection of the Update Cable
The procedure of the firmware update is described in Application Note ID ISC.ANT.UMUX – Firm-
ware Update (N80301-xe-ID-B).

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 11 of 19 M71100-3e-ID-B.docx
4. Operating and Display Elements
4.1. LEDs
The LEDs, located on the SMA jacks OUT1-8, indicate which antenna connection is switched
through. Table 2 shows the configuration of LEDs V1-4.
Table 2: LED configuration
Abbreviation Description
LED V1 (green) "RUN-LED"
-Indicates proper running of the internal software.
LED V2 (yellow)
Diagnostic 1: Communication-LED
-Short flashing indicates when the multiplexer has received a valid protocol from the
reader.
LED V3 (blue) Diagnostic 2: HF-LED
- Comes on when an HF-signal is present on SMA jack IN.
LED V4 (red)
Diagnostic 3: Warning
-Comes on when there is a false adaption at the activated antenna port.
-Flashes when there is a bypass or overload of the DC coupling.
4.2. Reset Button T1
Pressing the button T1 resets the multiplexer.

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 12 of 19 M71100-3e-ID-B.docx
4.3. DIP Switch S1
4.3.1. Hardware Address setting
DIP switches 1 and 2 are used for setting the hardware address. Table 3 summarizes the settings
for the levels.
Table 3: Address setting
DIP switch S1
Level
1
2
3
4
- - not assigned (default)
- ON Level 1
ON - Level 2
ON ON Level 3
For further information see the corresponding manual Communication FU UHF (H80302-xe-ID-B).
NOTE:
Changed settings become valid only after pressing the reset button T1 or interrupting the
supply voltage.
4.3.2. DC Coupling
A DC-Offset can be supported on the antenna outputs OUT1 – OUT8. By default is this the supply
voltage. For future uses it is also possible to switch on a DC-Offset of +7 V. The maximum current
for all outputs is 150 mA.
DIP switch 3 is used for setting the DC offset for the antenna connections. Table 4 summarizes the
settings.
Table 4: DC offset
DIP switch S1
DC offset
1
2
3
4
- 12...24 V (supply voltage)
ON 7 V
NOTE:
Changed settings become valid only after pressing the reset button T1 or interrupting the
supply voltage.

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 13 of 19 M71100-3e-ID-B.docx
5. Troubleshooting
Error conditions that could appear at the multiplexer and their clear conditions are summarized in
table 5.
Table 5: Error Conditions
Error Condition Error Trouble Shooting
No function Interruption of the power supply -Check power supply
No communication Transmitting power to low -Check output power of the reader
LED V4 comes on False adaption at the activated
antenne port -Check antenna cable
-Check antenna matching
LED V4 flashes Bypass or overload of the DC
coupling -Check antenna cable
-Check antenna

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 14 of 19 M71100-3e-ID-B.docx
6. Technical Data
MECHANICAL DATA
Housing Plastic, ABS
Dimension (W x H x D) 85 mm x 145 mm x 27 mm
3.35 inch x 4.72 inch x 1.77 inch
Weight 170 g (0.37 lbs)
Protection Class IP 30
Color black, transparent
ELECTRICAL DATA
Power Supply 12 V DC to 24 V DC ± 10 %
Power Consumption max. 5 W
Operating Frequency 860 MHz to 960 MHz
Insertion Loss max. 2.2 dB
Isolation min. 28 dB
min. Input Power 85 mW
max. Input Power 4 W
Antenna Connection
•1 x Reader
•8 x Antenna
SMA female (50 Ω)
SMA female (50 Ω)
FUNCTIONAL PROPERTIES
Optical Indicators 4 x LED for operating status and diagnotics
8 x LED for indication of active antenna output
DC Offset 7 V DC / 150 mA or
24 V DC / 150 mA

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 15 of 19 M71100-3e-ID-B.docx
AMBIENT CONDITIONS
Temperature Range
•Operation
•Storage
-25 °C to +55 °C / -13 °F to + 131 °F
-25 °C to +85 °C / -13 °F to + 185 °F
Humidity 5 % to 95 % non-condensing
APPLICABLE STANDARDS
EMC EN 301 489
Safety
•Low Voltage
EN 60950

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 16 of 19 M71100-3e-ID-B.docx
7. Radio Approvals
7.1. Europe (CE)
When properly used this radio equipment conforms to the essential requirements of Article 3 and
the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.
Performance Classification according to ETSI EN 301 489: Class 2

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 17 of 19 M71100-3e-ID-B.docx
7.2. Declaration of Conformity (Directive 1999/5/EC - R&TTE)
Figure 4: Declaration of Conformity

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 18 of 19 M71100-3e-ID-B.docx
ANNEX
ANNEX A - Accessories
The following accessories are available for the multiplexer:
Table 6: Accessories
Article No. Part No. Description
2557.000.00 ID NET.24V-B 24 V DC/ power supply with suitable connector;
Input voltage 100 - 240V AC
1691.000.01 ID ISC.MS.MR/PR-A Wall mounting kit
1690.000.00 ID CAB.RS-B Serial data cable for update
1962.000.00 ID CO.RS232/TTL-A External RS232/TTL Converter for update

OBID
i-scan
®
UHF
Installation
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH Page 19 of 19 M71100-3e-ID-B.docx
ANNEX A1 – Wall Mount Kit ID ISC.MS.MR/PR-A
The wall mounting kit can be used to attach the Multiplexer to a flat surface.
•Remove the screws from the back side of the Multiplexer.
•Attach the individual wall hangers using the screws supplied with the mounting kit.
Figure 5: Mounting wall hangers
93
125
153
65
Figure 6: Mounting drill dimensioning (all dimensions in mm)