Felix Storch F-940 User manual

Table of Contents
Table of Contents.........................................................................1
Introduction.................................................................................1
Specifications...............................................................................3
F-940 Specifications.....................................................................3
Unpacking the F-940 Store It!......................................................5
Operating Instructions.................................................................6
Loading the Battery .................................................................6
Basic Operation........................................................................7
Measurement Modes ..............................................................7
Continuous Mode ....................................................................9
Trigger Mode ...........................................................................9
Taking a Measurement ..........................................................10
Passcode Protection ..............................................................11
Setup Menu ...............................................................................12
Setup > Mode.........................................................................12
Setup > Set Zero.....................................................................13
Setup > Calibration ................................................................15
Setup > O2 Calibration in Air .................................................15
Setup > Date and Time...........................................................15
Setup > RH Conversion ..........................................................16
Setup > GPS............................................................................17
Setup > Language...................................................................17
Setup > Factory Setup............................................................17
File Menu ...................................................................................18

File > Select ............................................................................18
File > Create ...........................................................................19
File > Delete............................................................................19
File > Review...........................................................................19
Transferring Files....................................................................20
Wireless SD Memory Card Operation ....................................22
F-940 Store It! Menu Map..........................................................25
G.A.S. Gas Analysis Software......................................................26
Firmware Update .......................................................................35
Maintenance of your F-940 Store It! Gas Analyzer....................37
Replacing the Oxygen (O₂) Sensor..........................................37
Replacing the Potassium Permanganate Filter (KMnO4).......39
Calibration..............................................................................40
Applications................................................................................45
Sampling with a Jar ................................................................45
PolarCept................................................................................46
F-940 Production Test Check Sheet ...........................................48
Guide for Purchasing Standardized Gases for Calibration .........49
Warranty Information................................................................52
Warranty Registration Card .......................................................54

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 1
Phone: (360) 833-8835
www.felixinstruments.com
Introduction
Congratulations on the purchase
of your new F-940 Store It! Gas
Analyzer.
The F-940 Store It! Gas Analyzer
provides rapid and precise
measurements of ethylene, CO2
and O2. The Store It! was
designed for Quality Assurance
staff to increase shelf-life and
prevent spoilage of valuable
produce by monitoring ripening gases throughout the storage
process.
The Store It! features an intuitive user interface, making it
simple to operate right out of the box. Its lightweight, handheld
design enables users to rely on the Store It! at all stages of
storage along the supply chain. A built-in data logger stores
thousands of data points and conveniently transfers data
through USB or Bluetooth onto a PC or tablet for later analysis.
With its rapid response time and lightweight handheld profile,
the F-940 provides a fast, portable verification process for
atmosphere quality control. Easy to use straight out of the box
with little or no training, the F-940 is ideal for verifying CO2 and
O2levels in Modified Atmosphere Packaging (MAP) applications,
laboratories, distribution centers, retail centers, storage
facilities, and shipping containers.
We hope you enjoy using your F-940 Store It! Gas Analyzer.

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 2
Phone: (360) 833-8835
www.felixinstruments.com
Features
•The F-940 features include:
•Measures C2H4, CO2 and O2
•Displays results in under 30 seconds
•Past records stored on the device
•Handheld and lightweight
•Internal data logging and storage
•(WiFi capable SD card)
•Bluetooth data transfer
•Battery lasts for 8+ hours
•Display easily viewed in dimly lit environments
PolarCept!TM water filter for removing non-ethylene
hydrocarbons

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 3
Phone: (360) 833-8835
www.felixinstruments.com
Specifications
F-940 Specifications
Air Sampling Rate
70 mL/min
Measuring Rate
Automated, 1 second intervals to SD
in Continuous Mode
Data Storage
Removable 16 GB SD and Bluetooth
Display
Sunlight visible transflective LCD
Operating environment
0°C - 50°C (15-90% relative humidity,
non-condensing)
Power Source
Removable rechargeable lithium-ion
battery
Dimensions
18cm x 13.5cm x 5.5cm
Weight
0.95kg
Enclosure
Powder coated aluminum
Warm Up Time
<3 minutes
Sensors
Ethylene (C2H4)
SENSOR
Electrochemical
Nominal Range
0-10 ppm
Full Scale Resolution
0.03 ppm
Accuracy Trigger Mode
±5% relative ±0.15 ppm absolute
Accuracy Continuous
Mode
±5% relative ±0.030 ppm absolute
Lower Detection Limit
0.03 ppm
Sampling Time
30 seconds
Zero Interval
Weekly
Calibration Interval
3 months
Lifetime
2 years
Carbon Dioxide (CO₂)
SENSOR
Infrared sensor, pyroelectric detector

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 4
Phone: (360) 833-8835
www.felixinstruments.com
Nominal Range
0-100%
Full Scale Resolution
0.01%
Accuracy –Trigger
Mode
±.5% absolute and ±3% of measured
value
Accuracy –Continuous
Mode
±.01% absolute and ±3% of measured
value
Lower Detection Limit
0.01%
Sampling Time
10 seconds
Zero Interval
Weekly
Calibration Interval
12 Months
Lifetime
5 years
Oxygen (O₂) Sensor
Electrochemical
Nominal Range
0-100%
Full Scale Resolution
0.1%
Accuracy –Trigger
Mode
±0.3% absolute and ±2% of measured
value
Accuracy –Continuous
Mode
±0.1% absolute and ±2% of measured
value
Lower Detection Limit
0.1%
Sampling Time
10 seconds
Zero Interval
Weekly
Calibration Interval
6 Months
Lifetime
2 Years

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 5
Phone: (360) 833-8835
www.felixinstruments.com
Unpacking the F-940 Store It!
The F-940 arrives with a hard-sided carrying case, two sets of
batteries and a charger, a removable SD card, and several
accessory parts. A sampling port with needle is included for
taking non-destructive samples from packaging. The sampling
port is pictured below, connected to the intake. There is also an
extra Potassium Permanganate Filter (see Maintenance of your
F-940 Store It!: Replacing the Potassium Permanganate Filter)
and a Closed-Loop Probe used for sampling from Jars (see
Applications: Sampling with a Jar).

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 6
Phone: (360) 833-8835
www.felixinstruments.com
Operating Instructions
WARNING: Do not store the F-950 without batteries! Charged
batteries must be present in the instrument to maintain the
accuracy of the sensors, even when the unit is powered off.
If the batteries of the F-940 discharge during storage, replace
with charged batteries and allow the instrument to stabilize 48
hours before use. There is a small internal battery to maintain
the bias voltage for the ethylene electrochemical sensor. This
small internal battery will last for 1 day without the main
batteries before sensor sensitivity is affected by losing its bias
voltage. The calibration parameter data is intact with or without
batteries.
Loading the Battery
WARNING: Spring-loaded battery cartridge
The F-940 uses 18650 Li-ion 3.7V
3100mAh rechargeable batteries. For
longer lifespan, charge the batteries at
0.25A. For a faster charge, charge at
1A. The batteries must be removed
from the F-940 to be charged. If the
batteries of the F-940 discharge during
storage, replace with charged batteries.
The Li-ion batteries have little self-
discharge and a lifetime of ~ 3 years.
To remove the batteries, twist the
battery compartment cap, located on the bottom of the case.
The cap can be twisted with fingers or a screw-driver to tighten
or loosen it. Take care when removing batteries, as the cap is

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 7
Phone: (360) 833-8835
www.felixinstruments.com
spring loaded. Both batteries should be inserted into the unit
positive (+) side first (towards intake or top).
Additional button-top 19670 (or protected 18650) batteries can
be purchased from your preferred battery vendor if
replacements are needed.
Basic Operation
To turn the instrument on, press the green power button. The
current version of firmware the unit is running is displayed in
the lower Left hand corner.
For information on the latest firmware version, please visit the
F-940 support webpage: www.felixinstruments.com/support/F-
940
The battery meter is listed on the lower right hand side of the
display.
The main menu displays the following options: Measure, Setup,
and File. If the power button is pressed, the display will prompt
for confirmation before shutting down the F-940.
To scroll between menu
items in the list, use the Up
and Down arrows. To select
an option from the menu
list, use the Right arrow. To
exit, use the Left arrow.
Measurement Modes
Two measurement modes are incorporated into the F-940 Store
It!
Felix Instruments
Measure
Setup
File
F-940 Vx.x.x.x

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 8
Phone: (360) 833-8835
www.felixinstruments.com
Continuous mode
Trigger Mode
Continuous mode measures the air entering through the input
of the instrument continuously without stopping. Continuous
mode can be used with or without the sample port attached to
the front of the instrument. Data is saved to a file every one
second on the F-940.
Trigger mode measures the air entering through the input of
the instrument, the pump will run and the sample will enter
until a stable reading has been achieved. The final values will be
displayed on screen and saved to the SD card. The pump will
then turn off until the user initiates a new measurement.
Trigger mode can be used with or without the sample port
attached to the front of the instrument. See the specifications
page for standard sample volume.
To change between modes, Navigate to Setup > Mode from the
main menu.
Measure
From the main menu, press the right arrow when the word
‘Measure’is highlighted to enter the measurement display
screen. All measurement parameters are saved to the SD card
every 1 second in continuous mode. When the SD card is not
present, the data will not be saved. The unit also comes
equipped with Bluetooth technology, designed for wireless
transfer of data (see Transferring Files).
If sampling very high concentrations followed by very low
concentrations, allow the instrument to purge internal gas for
the most accurate measurements.

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 9
Phone: (360) 833-8835
www.felixinstruments.com
Continuous Mode
When in continuous mode, a graph of the concentration of each
gas can be viewed over time. The default graph shown is the O2
concentration in ppm. To view the C2H4 or CO2 graph, simply
use the up and down arrows to scroll through the graphs. The
current gas being graphed is shown on the top of the screen
with the concentration in large font as shown below.
The x-axis of the graph represents time elapsed. The y-axis of
the graph displays the range of the concentration in % for CO2
and O2, and the dynamic range is labeled at the top. The y-axis
scale is set by the highest value shown in the active display.
The graph begins on the Left side and moves toward the right as
more data accumulates. The total measurement time is
displayed below the graph. The flowrate (mL/m) is displayed at
the bottom.
Trigger Mode
A measurement in trigger mode will initiate a small volume
sample taken over several seconds until the reading is stable. To
begin, press the square start button as prompted to measure.
This will turn on the pump before drawing in sample gas. Trigger

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 10
Phone: (360) 833-8835
www.felixinstruments.com
mode will take longer to stabilize if the concentration is in a
different range from the last sample.
The results will be saved to the SD card. Press the square start
button to begin another measurement. Press the Left arrow to
exit to the main menu.
Taking a Measurement
Assemble the probe and connect the needle probe tubing to the
intake of the F-940. Twist on a hydrophobic filter to the end of
the tubing. The filter will prevent any moisture or debris from
entering the instrument. [NOTE: Failure to use a hydrophobic
filter risks drawing liquids into the instrument, which can
potentially damage the instrument sensors.] Finally, attach a
sterile needle to the filter. Depending on the application,
needles can be re-used.

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 11
Phone: (360) 833-8835
www.felixinstruments.com
From the main screen, select ‘Measure’ and then the right
arrow button. This will initiate a measurement in either mode.
The F-940 will run either continuously (continuous mode) or
until the minimum stable sample volume has been reached
(trigger mode). Press the Left arrow button to return to the
measurement screen.
Passcode Protection
Certain menu systems on the F-940 are protected by a passcode
setting. These menu systems include Parameters, Set Zero,
Calibration, and Factory Setup. The default code for entry is
‘1111’. The passcode only needs to be entered once for each
reboot of the device. If the device is powered off, the passcode
will need to be entered again for entry into the menu systems
described above.
To set the passcode to a four-digit code other than the default
setting, please follow the steps below.
1. Open SD card on PC
2. Click the ‘View’ tab in the taskbar
3. Click ‘Options’ in the far right of the toolbar
4. Open the ‘View’ tab
5. Scroll down and uncheck the box named ‘Hide
protected operating systems (Recommended)’

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 12
Phone: (360) 833-8835
www.felixinstruments.com
6. Check the box named ‘Show hidden files, folders, and
drives’
7. Click ‘Yes’
8. Click ‘Apply’ and then click ‘OK’
9. Open the Config.txt file that should now appear inside
the SD card
10. Alter the ‘1111’ to four-digit numeric passcode desired
11. Save the changes
12. Insert SD card back into Gas Analyzer
Setup Menu
Use the right arrow to enter the Setup Menu from the Main
Menu screen. The following options are available:
Mode
Set Zero
Calibration
O2 Calibration in Air
Date & Time
RH Conversion
GPS
Language
Factory Setup
Setup > Mode
The Mode menu contains two options:
Measure: switches between Continuous and Trigger mode.
Connection: switches between USB Storage (default), Bluetooth
(enabled in future versions), or USB Ctrl (enables
communication to controller software).

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 13
Phone: (360) 833-8835
www.felixinstruments.com
To change, use the Up/Down arrows to cycle through the mode
options. Press the Left arrow to exit to the main menu.
Setup > Set Zero
The set zero process sets a new baseline, or zero, for the
sensors:
C2H4
CO2
O2
Set zero should take place weekly for all sensors. To set zero,
first press the right arrow to select the sensor. Wait for a beep
to verify the set zero process was completed. The set zero
process requires the use of 100% nitrogen gas to set zero for
O2, an internal Potassium Permanganate jar to set zero for
C2H4, and an external conditioning chamber full of Soda Lime to
set zero for CO2. Setting zero is important in establishing a zero
baseline for the sensors.
For the O2 sensor, an alternative calibration, O2 calibration in
air, can be used instead of setting zero with 100% N2 gas. Please
see the ‘O2 Calibration in Air’ section for more details on this
process.
Mode
Measure Trigger
Connection USB Storage

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 14
Phone: (360) 833-8835
www.felixinstruments.com
The following instructions can be followed to set zero for the
CO2 sensor:
The F-940 is shipped with an external conditioning tube and a
jar of Soda Lime. Fill the conditioning tube with the Soda Lime
granules, keeping the ends packed with the cotton ball filters.
Connect the external conditioning tube to the inlet and outlet of
the F-940, seen below. Continue through the standard set zero
process. The F-940 will prompt the user to use “0ppm/N2”. The
Soda Lime external conditioning tube creates a 0 ppm CO2
environment, alternatively, the user can connect N2 gas, which
provides a 0 ppm CO2 environment as well.
*The Soda Lime external conditioning tube is used for the CO2
Set Zero process only.

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 15
Phone: (360) 833-8835
www.felixinstruments.com
Next, verify the set zero calibration for all sensors by measuring
ambient air. Run the set zero calibration again if the verification
is not successful.
Setup > Calibration
The calibration feature allows the user to set zero and set span
without the use of a computer or G.A.S. (Gas Analysis Software).
Unlike Setup > Set Zero in the next section, a zero standard gas
is required as well as standard gases for the set span process.
The F-940 Store It! Will prompt the user to set up a zero gas,
which can be achieved by feeding 100% Nitrogen (N2) gas to the
intake. The unit will countdown to set zero. The following
screen will prompt the user to setup a span gas, which is a
known standard gas used for the span calibration process. For
more information on standard gases used for calibrating the
Store It! Refer to the calibration section in the ‘Maintenance of
your F-940 Store It!’ section.
Setup > O2 Calibration in Air
Alternative to setting zero for the oxygen sensor weekly with
100% N2 gas, a user can use the O2 calibration in air menu
option to calibrate the O2 sensor using ambient air.
Right arrow on this menu option to begin the calibration. The
display will read, ‘Use fresh air (20.9%) Please wait…’. The F-940
will beep upon completion of the O2 calibration in air.
Setup > Date and Time
To adjust the date and time, use the Right and Left arrows to
move between Month/Day/Year and Hour/Minute/Second and
use the Up and Down arrows to change the values. To exit, use

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 16
Phone: (360) 833-8835
www.felixinstruments.com
the Left arrow to back out of the screen and return to the Setup
menu.
Setup > RH Conversion
The Setup RH Conversion menu is used to correct for the
temperature sensor being inside F-940 housing. This causes the
temperature sensor to reflect the temperature of the F-940 and
not the ambient temperature, which is usually several degrees
above ambient. The Relative Humidity is calculated based on
the temperature value.
Enter the correct ambient temperature in degrees Celsius,
measured from an external
temperature sensor. To use
the entered temperature for
RH calculations, “use sample
T” should be set to “Yes.”
The current (internal RH) and
corrected (sample RH) are
displayed at the bottom of
the screen.
Date & Time
MM/DD/YYYY hh : mm : ss
04/21/2016 17 : 01 : 43
RH Conversion
Enter Sample T(C) 20.0
Use Sample T Yes
(for measurements)
Internal RH (%) 43.6
Sample RH (%) 21.3

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 17
Phone: (360) 833-8835
www.felixinstruments.com
Setup > GPS
The GPS sensor inside of the F-940 Store It! can be used to
record latitude and longitude +/- 10 meters. The instrument
should be operated outside, without overhead obstruction for
best GPS performance. The Setup > GPS menu turns on/off the
GPS sensor and displays the current GPS data. Data is also
saved to the SD card as a .csv file.
Setup > Language
The Language menu will display options for:
English
Spanish
Portuguese
Use the Up and Down arrows to select.
Setup > Factory Setup
The Factory Setup menu is used to:
Restore: Restores factory defaults
Backup: Backs up current parameters. “Backup device’s
GPS
Enable GPS Yes/No
Acquiring GPS data…..
Longitude 122.558
Latitude 45.59

F-940 Instruction Manual rev. 3-8-2017
1554 NE 3rd Ave, Camas, WA 98607, USA 18
Phone: (360) 833-8835
www.felixinstruments.com
configurations?”: NO or YES
File Menu
In the File Menu, the user can manipulate files on the F-940
Store It! The F-940 will by default save to the most recently
used file on the instrument. The file menu contains:
Select
Create
Delete
Review
All files created by the F-940 are .csv (comma separated value)
file extensions.
To view data on a computer, simply insert the SD card into a
computer’s SD card reader (always power off the F-940 before
removing the SD card). The computer should automatically
detect the SD card as a new storage device enabling access to
measurement data from any computer. The mini-USB port can
also be used to establish a USB connection with a computer to
transfer data from the F-940 Store It!
File > Select
File Select displays a list of .csv files that exist on the F-940 Store
It! SD card. Use the Up/Down arrows to move between files,
and right arrow to select a file to which new data will be saved.
Select
Data . csv
16_04_04_0 . csv
Table of contents
Other Felix Storch Measuring Instrument manuals

Felix Storch
Felix Storch F-750 User manual

Felix Storch
Felix Storch F-900 User manual

Felix Storch
Felix Storch F-950 User manual

Felix Storch
Felix Storch F-750 User manual

Felix Storch
Felix Storch F-960 User manual

Felix Storch
Felix Storch F-950 User manual

Felix Storch
Felix Storch Check it! F-920 User manual
Popular Measuring Instrument manuals by other brands

Endress+Hauser
Endress+Hauser Liquiline System CA80HA operating instructions

Ametek
Ametek SPECTRO ARCOS FHX22 Original operating instructions

LR-Cal
LR-Cal LTR FLUID manual

Minebea
Minebea CSD-892B-74 instruction manual

CDI Meters
CDI Meters CDI 25 Series Installation and operating instructions

Alemite
Alemite 3644-C2 Short guide