Fenwal F11-Y1 Series Administrator Guide

Page 1
Photoelectric Smoke Detector
F11-Y1-xx
Operation Instruction Manual
ES1103 K0
Thank you for purchasing this product.
n this manual, we have shown the important notice in order for you
to use the device just and the method of handling this system.
n addition to you read this manual well before the utilization,
understanding well, and use.
After you read, in the place where it is seen with anytime, please be
sure to keep.

730110 K0
頁 2
ES1103
Table of contents
1. Safety Instructions.......................................................................................................................3
2. Name and Function of each section ............................................................................................4
2-1. Detector(Type:F11-Y1)....................................................................................................... 4
2-2. ounting Base(Type:FBR-Y).................................................................................................. 5
2-3. Outline Dimensions........................................................................................................................ 6
3. Install...........................................................................................................................................7
3-1. Installation place ............................................................................................................................ 7
3-2. ethod of installation..................................................................................................................... 8
4. Specifications ............................................................................................................................10
4-1. Part Number ................................................................................................................................ 10
4-2. Electric specifications................................................................................................................... 10
4-3. echanical specifications .............................................................................................................. 10
4-4. Environmental specifications ........................................................................................................ 11
5. Self check Function...................................................................................................................12
6. aintenance and Inspection......................................................................................................12
6-1. Daily Inspection ........................................................................................................................... 12
6-2. Periodic Inspection....................................................................................................................... 12
7. Disposal.....................................................................................................................................13
8. Support ......................................................................................................................................13

730110 K0
頁 3
ES1103
1. Safety Instructions
・Before the using, read this chapter and use correctly.
・The contents which it occurs when you handle erroneously are divided in two of “warning” and “caution”.
This division states clearly the size and impendence of the harm and the damage.
・Please keep below rules for safety.
・A term of a guarantee and a guarantee range
【A term of a guarantee】
In regard to the guarantee of this product, the designated payment of the order main thing after the paying
1 years you guarantee first only the breakdown which occurs in the normal busy condition which you
follow the instruction manual.
【guarantee range】
In regard to the breakdown which it occurs in this product with the criticism of payment person side during
the above-mentioned guarantee period, it does returns repair in the responsibility of payment person side.
However, when it corresponds next, you exclude from the object of this guarantee.
①Fire, earthquake and the damage by wind and flood, breakdown and the loss by the thunderbolt and
other natural disasters etc.
②After the shipping, transporting and moving and falling etc at your corporation, breakdown and the loss
with inadequate handling.
③When cause of breakdown due to the reason other than the payment item.
Caution
!
!!
!
!
!!
!
Warning The Warning symbol is
used to indicate situations and conditions that can
cause operator serious injury and/or equipment damage.
The Caution symbol is used to ind
icate situations and conditions that can
cause operator injury and/or equipment damage.
!
!!
!
Warning
・Do not disassemble a detector. It causes trouble.
・Do not remove a detector, Fire can not be detected.
・Do not use detector which have impacted. And als
o do not paint or cover a
detector.
・
Do not soak a detector in water, and do not put a detector into water. It
causes electric shock.
・Do not use the method that not listed in this manual, It causes trouble.
Caution
!
!!
!
・
This system only tells the outbreak of a fire. This system is not Fire
prevention systems. And Fire extinguishing system.
・Do not use at the place where it exceeds en
vironmental specification. It
causes trouble.
・Do not put heat source under the detector.

730110 K0
頁 4
ES1103
④Error in regard to use of the consumer, breakdown and the loss with repairing, remodeling other than
our company and error connecting.
Furthermore, the guarantee referred to here being something which means the guarantee of the payment
item single unit, pardons the damage which is induced by the breakdown of the payment item.
2. Name and Function of each section
2-1. Detector(Type:F11-Y1)
① State Indication LED
・Normal supervision ・・・ 10 seconds interval
・Alarm mode ・・・ 2 seconds interval
・Trouble mode ・・・ Off (not blinking)
②Address Seal
It indicates detector‘s address.
③Smoke chamber
The embedded sensor is to detect a smoke concentration.
Flashing tim
e is also longer by communication status between Detector and
Control unit.
Caution
!
!!
!

730110 K0
頁 5
ES1103
2-2. ounting Base(Type:FBR-Y)
①Wiring Terminal (4 places)
These holes are Wiring Terminals for communication and power supply.
L and C terminals each have two terminals. Two of each terminals are internally connected. Please
wire to another Base.
②Wiring Screw
It’s a wiring screw.
Do not put a line into this terminal except communication line.
It causes trouble.
Tighten the wiring screw with the specified torque. If it’s loose, it causes fire
and malfunction. (torque 0.5N
・
m
:
Reference value)
Conformity wire
18-26AWG
(Incase of Pin terminal, under φ2mm)
Strip length
4~5mm
!
!!
!
Warning
!
!!
!
Warning

730110 K0
頁 6
ES1103
2-3. Outline Dimensions
<Detector>
<ounting Base>

730110 K0
頁 7
ES1103
3. Install
3-1. Installation place
Smoke detectors should be installed in order to detect following place.
・The flow of smoke into position
・Fans forced to inhale position
When you use smoke detector in a fast wind speed, it is necessary that the smoke is ongoing around
detector. Please be careful.
Address number should be placed below or sideways
・The smoke detector detects a
scattered light by smoke particles optically.
And that detects a large amount of dust and steam too.
Please install correct location.
・
Do not use at the place where it exceeds environmental specification. It
causes trouble.
・Do not install wrong location. The smoke detector cannot detect a smoke.
・Be sure t
o install the detector away from sources of electrical noise such as
high voltage and high current switches.
[Isolation from electric noise source such as power line]
The signal conductor which is connected to the detector, please wires
over
20cm separating from the power line.
Case it is not possible, please pas
s in the metallic conduit which the power line
is grounded.
・Do not disassemble and repair and remodel a detector. It causes trouble
・Do not remove a detector, Fire can not be detected.
・Do no
t use a detector which has impacted. And also do not paint or cover a
detector.
・Do not
wiring while power is on. It causes electric shock and detector
troubles.
Caution
!
!!
!
Caution
!
!!
!
!
!!
!
Warning
over 20cm
over
20cm
F11-Y1
F11-Y1

730110 K0
頁 8
ES1103
3-2. ethod of installation
(1) Installation of ounting Base
Please install a ounting Base to “install holes” with two screws 3 which is more than 15mm length.
(See above)
(2)Wiring
Please connect wires to holes of Wiring Terminal of ounting Base (L, C).
Be sure to ground shielded of shield cable to the FG terminal of the control unit.
Branch Wiring is possible, and no polarity.
But do not bundle high voltage wires and electrical noise emitted wires with, or run them close to.
・
Incorrect loading of the equipments can cause a malfunction, failure or
drop.
・Tighten the screw in the specified torque range.
・Under tightening can cause a drop, short circuit or malfunction.
・
Over tightening can cause a drop, short circuit or malfunction due to
damage to the screw or he equipments and malfunction and fire.
Tighten the wiring screw with the specified torque. If it’s loose, it causes fire
and malfunction. (torque 0.5N
・
m
:
Reference value)
Conformity wire is AWG18 -
AWG26. Otherwise, use a wire and cause a
failure.
Conformity wire
18-26AWG
(Incase of Pin terminal, under φ2mm)
Strip length
4~5mm
Caution
!
!!
!
!
!!
!
Warning
!
!!
!
Warning

730110 K0
頁 9
ES1103
(3) Put a Detector into ounting Base
Please put both insert guides together, and insert Terminal and Attachment of Detector into ounting
Base. And Turn a Detector Clockwise until make a sound with "a snick". (See above)
・Put Insert guides, Detector Terminal and Attachment together correctly.
It causes trouble.
・Do not turning a detector too much. Also do not make a lack of insertion.
・Do not remove a detector, Fire can not be detected.
・
Do not use detector which have impacted. And also do not paint or cover a
detector.
!
!!
!
Warning

730110 K0
頁 10
ES1103
4. Specifications
4-1. Part Number
4-1-1. Detector
(1) Name of item: Photoelectric smoke detector
(2) Type: F11-Y1-xx (“xx” means Address. It is on Address seal.)
4-1-2. ounting Base
(1) Name of item: ounting Base
(2) Type: FBR-Y
4-2. Electric specifications
(1) Rating: DC24V 0.5mA(Be supplied by the control unit. No polarity.)
(2) Range of Working Voltage: DC16.0V~DC30.0V
(3) Current consumptions
(at DC24V): 0.35mA or less at Normal supervision
0.45mA or less at Alarm mode
(4) Set up for receiving
the Alarm signals: 5%/m (Nominal)
(5) State Indication LED: Red LED (blinking)
State of LED
Normal supervision 10 seconds interval
Alarm mode 2 seconds interval
Trouble mode Off (not blinking)
Trouble mode gives priority over the Alarm mode.
(6) Self Check Function
(Sensitivity revise): The Detector revise own sensitivity changes automatically once
a day. Use of Environment and Dirty and Degradation of Optics
parts cause of sensitivity changes.
Limit the amount of sensitivity revision come and failure.
(7) Address: Addresses are stored in EEPRO . If EEPRO has problem,
Detector will be trouble state.
(8) Power off Time: Turn off the power on again until 60 seconds margin over time.
(9) ounting Base: FBR-Y
(10) Compatible Control Panels: FC1 (For details, refer to the user's manual for the control unit.)
4-3. echanical specifications
4-3-1. Detector
(1) External form: φ28×H47mm
(2) ain material: ABS, PBT (UL-94V-0)
(3) Color: Beige
(4) ass: Approximately 20g
4-3-2. ounting Base
(1) External form: φ28×H10mm
(2) ain material: ABS (UL-94V-0)
(3) Color: Beige
(4) ass: Approximately 10g

730110 K0
頁 11
ES1103
4-4. Environmental specifications
(1) Working temperature range:
0℃~50℃
(2) Storage temperature range:
-20℃~70℃
(3) Working humidity range:
30~85%R.H, Non condensing
(4)
Resistance to corrosion
: No tolerance to acid and alkaline.
Use the detector in an environment that meets the general specifications
contained in this manual. Otherwise i
t causes trouble and erroneous
operation.
Working temperature and humidity will affect the life span of equipment.
Please consider derating and use.
Caution
!
!!
!
!
!!
!
Warning

730110 K0
頁 12
ES1103
5. Self check Function
The Detector revise own sensitivity changes automatically once a day.
Use of Environment and Dirty and Degradation of Optics parts cause of sensitivity changes. Limit the
amount of sensitivity revision come and failure. And State Indication LED lights in trouble. Also the
detector notifies the control unit of own trouble status.
6. aintenance and Inspection
6-1. Daily Inspection
・Please check State Indication LED is blinking 10 seconds interval. Also check indication of the control
unit is normal. (For detail of the control unit, refer to the user's manual for the control unit.)
・If there are Adhesion of dirt and foreign matter on surface of the detector, Please remove it with cloth
which wring the water out tightly. And then prevent water from infiltration carefully.
6-2. Periodic Inspection
・Please check State Indication LED is blinking 10 seconds interval. Also check indication of the control
unit is normal. (For detail of the control unit, refer to the user's manual for the control unit.)
・Do not needs to check smoke detect function with real smoke such as Tobacco, incense, etc. Because
this smoke detector has self check functions. (Refer to 「5.Self check function」)
・Please do visual inspection periodically. There are possibilities that an entrance of the smoke chamber
cover with dust and foreign matter, and continue to use and malfunction.
・If there are Adhesion of dirt and foreign matter on surface of the detector, Please remove it with cloth
which wring the water out tightly. And then prevent water from infiltration carefully.
Please refer to the user’s manual for the control unit about functional connection the control unit and the
smoke detector.
Do not soak a detector in water, and do not put a detector into water. It causes
electric shock and trouble.
・
Do not soak a detector in water, and do not put a detector into water. It
causes electric shock and trouble.
・After Cleaning, d
o not leave a foreign substance such as sawdust or wiring
debris on a detector. Such debris could cause erroneous operation.
・Do not clean with a solvent such as a ph-
balanced detergent, Bleach,
Benzene, Thinner, Alcohol. It causes the detector surface is damaged.
!
!!
!
Warning
!
!!
!
Warning

730110 K0
頁 13
ES1103
7. Disposal
This product is as general industrial waste disposal. Disposal methods are specific criteria depending on
each municipality.
8. Support
Please inquire about this product to Fenwal Controls of Japan Co., Ltd. Tokyo headquarters.
Fenwal Controls of Japan Co., Ltd.
1-5-10 Iidabashi Chiyoda Tokyo, 102-0072 Japan
Tokyo headquarters: +81-3-3237-3565
Table of contents
Other Fenwal Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

BRK electronic
BRK electronic 83RN quick start guide

System Sensor
System Sensor ECO1003ABLINK Installation and maintenance instructions

ESE
ESE BRK First Alert SA511B quick start guide

Wheelock
Wheelock SERIES NS-24MCW installation instructions

NOXE
NOXE LUMENS Installation and user guide

Xtralis
Xtralis VESDA VLI Technical Tip