4. Troubleshooting Guide
3. Other Alarm Visual And Audible Indicators
If you require further information please contact Product Support at 1-800-880-6788 or write us at:
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302. Our internet address is www.kidde.com.
Trouble Condition
Visual Indications Audible Indications Action
Low Battery Amber LED blinks every 
60 sec.
Chirp every 60 sec. * Push button once to silence for 24 hrs. 
(Pushbutton again to clear HushTM and 
perform a test.) 
Note: 7 days after Low Battery begins, the 
notications cannot be silenced.
* Replace batteries as soon as possible.
Photo Fault Amber LED blinks every 
60 sec.
3 chirps every 60 sec. * See Cleaning Your Alarm section.
* Push button once to attempt to reset the unit.
* If error continues, remove alarm, 
dispose unit, and replace as soon as possible.
CO Fault Amber LED blinks 2 times 
every 60 sec.
3 chirps every 60 sec. * Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose unit, 
and replace as soon as possible.
Memory Fault Amber LED blinks 3 times 
every 60 sec.
3 chirps every 60 sec. * Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose unit, 
and replace as soon as possible.
End of Unit Life Amber LED blinks 2 times 
every 60 sec.
2 chirps every 60 sec. * Push button once to silence for 24 hrs. (Push 
button again to clear HushTM and perform 
a test.)
 Note: 7 days after End of Unit Life begins, the 
notications cannot be silenced.
* Remove alarm, dispose unit, and replace as 
soon as possible.
MCU Failure None Constant Tone * Remove alarm, dispose unit, and replace as soon 
as possible.
Stuck Button Amber LED blinks 4 times 
every 60 sec.
3 chirps every 60 sec. * Push button to dislodge it from being stuck. 
If button cannot be unstuck, remove alarm, 
dispose unit, and replace as soon as possible.