Type 1 Type 2
Detection Sensitivity:
This determines the effective range of
the motion detector and is set by DIP
switches on the sensor itself. Note
that reducing the sensitivity will also
narrow the detection range.
Sensor Sensitivity:
Adjustable ‘-’ approx. 2M to ‘+’ approx 10M
Meter
Time
Lux
The following settings are available:
I - maximum range up to 5m
II - range up to 3.5m
III - range up to 2m
IV - range up to 1.5m
V - range up to 1m
The following settings are available:
I - 2 Lux darkness operation only
II - 5 Lux darkness operation only
III - 20 Lux twilight operation
IV - 30 Lux twilight operation
V - daylight, daylight sensor
operation disabled
Hold Time:
This determines the length of time
the lamp is held on after movement is
detected and is set by DIP switches.
The walk test setting is useful when
installing the tting to establish
correct operation and range.
Delay off Time:
5 sec to 30 min range and Test mode
Daylight Sensor:
This setting holds the lamp off should
there be sufcient daylight and is set
using DIP switches on the sensor.
IMPORTANT NOTE: When a setting change on a micro-sensor has been
made, the luminaire must be power cycled for the change to take effect.
Ambient Light Override:
Approx. 5 Lux to
5 Lux - sensor module can work at dark status only
- sensor module can work at any light level
30m Test
5s
5m15m
5
100
500