DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED
Contact factory or specialized personnel for error codes
Code Description Possible Cause Corrective Action
001
Software error-error on start up or
corrupted software
Improper start-up or
shutdown
Restart, if still fault: reload software
002
Internal flash corrupted
internal data memory malfunction
Error found in cyclic
redundancy check CRC
Restart, if still fault: reload software
If not corrected: replace board
Short-circuit in temperature probe
051 Open temperature probe.
Bad probe connection, or
probe failure.
Check all connections. Replace probe if
necessary.
100
Initial fill time took longer than
expected after powering up.
Water supply flow rate is
too low, fill valve is stuck,
water line kinked or closed.
Reboot machine. If persists-investigate
cause of low flow rate. (Clogged water
filter, kinked line, stuck fill valve)
101 Error on refill-.
Tank did not refill within expected time.
Water supply flow rate to
hot water tank is too low, or
fill valve stuck or damaged
Check water supply line. Flow should be
20-75 psig, (138-517kPa) >1gal/3.8L/min
Investigate cause of low flow rate. If the
flow rate is in range-replace fill valve
200 Heating flatline-Tank is boiling
Heater is on, temperature is
not rising/dropping
High elevation correction. Bad heaters
or temperature probe or position
201
If the hot water tank heaters are turned
on during a heating cycle and tank
temperature is not increasing
according to software logic and the
tank temperature is below setpoint
1) Failure of SSR, high limit,
temperature probe, or
heating element.
2) Water being removed by
hot water faucet during
heating (control displays
1)Test and check SSRs, high limit
devices temperature probe. Check
heating elements with current clamp,
replace if necessary.
2)Advise staff to refrain from taking large
amounts of water from hot water tank,
especially during “heating”.
202 Heater Shorted or Stuck SSR
Heater is off and heating
SSR is stuck “ON”
Check ohms on heater (15-60Ω). SSR
may be stuck in ON mode-replace SSR.
255 Keyboard [HID] error
(Human Interface Device)
Usually from longer than 10
seconds’ contact. Or faulty
Restart, if still fault: reload software. If
mechanical: replace module
NO
BSKT
Insert Brew Basket
place
This is a
Insert brew basket into brewer rails to
enable brewer