manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fike
  6. •
  7. Monitor
  8. •
  9. Fike FIK-W-MONITOR User manual

Fike FIK-W-MONITOR User manual

FIGURE 1. CONTROLS AND INDICATORS
C1095C-00
FIGURE 2. FACEPLATE INTERIOR
MAGNET LOCA
TION
(DO NOT REMOVE)
C1098-00
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer to
the control panel installation manual and the SWIFT Wireless Manual for de-
tailed system information. If the modules will be installed in an existing op-
erational system, inform the operator and local authority that the system will
be temporarily out of service. Disconnect power to the control panel before
installing the modules.
NOTICE: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
The FIK-W-MONITOR Monitor Module is intended for use with a wireless
gateway or wireless fire alarm control panel (FACP) to interface with a device
having contacts used to signal status conditions. The input to the monitor
module is non-latching and does not require a reset. The device communi-
cates through a robust, bi-directional mesh network to the gateway and/or
FACP. Rotary dial switches are provided for setting the module’s address. The
module has a panel controlled LED indicator. (See Figure 1.)
FACEPLATE
The faceplate includes a magnet for activation and tamper resistance. (See
Figure 2.) The faceplate magnet activates communication to the panel, there-
fore, the faceplate must be installed for the module to work properly. The
magnet also activates a supervisory tamper fault at the panel if the nameplate
is removed. Do NOT remove this magnet. The faceplate for a wireless module
CANNOT be replaced with the faceplate of a standard wired module.
BATTERY REPLACEMENT
Low battery levels on the wireless devices are displayed as a trouble in the
FACP. Therefore when the message “TROUBLE BATTERY LOW” is displayed,
replace the battery in the device. This message is an indication that approxi-
mately one week of battery life remains.
COMPATIBILITY REQUIREMENTS
To ensure proper operation, this module shall be connected to a compatible
Fike Series system control panel (list available from Fike).
To replace the batteries in a wireless device use the following steps:
1. Have 4 CR123A (or DL123A) batteries available
2. Remove the faceplate from the module.
3. Open the battery compartment refer to Figure 3.
4. Remove the used batteries and replace with new batteries. The battery com-
partment is designed such that the batteries can only align in the appropri-
ate direction. Do not force the batteries into the openings.
5. Replace the battery compartment cover.
6. Replace the faceplace.
I56-6962-000
INSTALLATION AND MAINTENANCE INSTRUCTIONS
SPECIFICATIONS
Maximum Operating Voltage: 3.3 VDC
Maximum Current Draw: 5.0 mA (LED on)
Average Operating Current: 210 µA, 3.9k EOL
EOL Resistance: 3.9K Ohms
Maximum IDC Wiring Resistance: 10 Ohms
Maximum IDC Voltage: 3.2 Volts
Maximum Average IDC Current: 5.5 µA
Maximum Transmit RF Power: 17 dBm
Radio Frequency Range: 902-928 MHz
Temperature Range: 32°F to 120°F (0°C to 49°C)
Humidity: 10% to 93% Non-condensing
Battery Type: 4 Panasonic CR123A or 4 Duracell DL123A
Battery Life: 2 year minimum
Battery Replacement: Upon TROUBLE BATTERY LOW display and/or during annual maintenance
Dimensions: 4¼ in. H x 4¼ in. W x 1½ in. D
Accessories: SMB500-WH Electrical Box (preferred mounting option)
R
704 SW 10th Street
Blue Springs, MO 64015
Phone: 816.229.3405; Fax: 816.228.9277
www.fike.com
FIK-W-MONITOR
Wireless Monitor Module
http://www.fike.com/06-912
Fo
r system/product documentation including
installation, operation, and maintenance,
scan QR code or enter URL provided.
1 I56-6962-000
1/19/2021
SPACING
Wireless technologies can exhibit communication disruption if devices are
spaced too close together. To avoid this form of disruption, SWIFT devices
should not be placed closer than 2 feet (60 cm) apart without an intervening
structure.
MOUNTING
The FIK-W-MONITOR mounts directly to an SMB500-WH electrical box. (See
Figure 4.) To avoid interference with the wireless network metal electrical
boxes are NOT recommended. Non-metal surface mounted electrical boxes
(SMB500-WH) are available from Fike. If not using an SMB500-WH, the mini-
mum mounting opening dimensions for the FIK-W-MONITOR are 4 in. X 3¾
in. x 1½ in. deep.
NOTE: Do not attach the module to temporary structures such that the place-
ment could be altered.
WIRING
NOTE: All wiring must conform to
applicable local codes, ordinances,
and regulations. This module is in-
tended for power limited wiring only.
FIK-W-MONITOR must be within 3
feet of monitored device when using
field wiring or 20 feet in non-metallic
conduit.
1. Install module wiring in accor-
dance with the job drawings
and appropriate wiring dia-
grams.
2. Set the address on the module
per job drawings.
3. Secure module to electrical
box (supplied by installer), as
shown in Figure 4.
C1096-00
C1097-00
FIGURE 4. MODULE MOUNTINGFIGURE 3. BATTERY COMPARTMENT
BATTERY
COMPARTMENT
DOOR
BATTERY
COMPARTMENT
C2002-00
FIGURE 5. TYPICAL MONITORING CONFIGURATION
WIRELESS
MONITOR MODULE
ONLY ONE UL LISTED CONTACT
CLOSURE MAY BE USED
POWER LIMITED
3.1 VDC MAX
3.9K EOL
RESISTOR
A2143-10
INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER’S
INSTALLATION INSTRUCTIONS. WIRELESS MONITOR MODULE MUST BE
WITHIN 3 FEET OF MONITORED DEVICE WHEN USING FIELD WIRING
OR 20 FEET IN NON-METALLIC CONDUIT.
C1099G-00
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Do not make changes to the equipment. Changes or modifications not expressly approved by the manufacturer could void
the user’s authority to operate the equipment.
LICENSING STATEMENT
Use of these products in combination with non-Honeywell products in a wireless mesh network, or to access, monitor or control devices
in a wireless mesh nework via the internet or another external wide area network, may require a separate license from Sipco, LLC.
For more information, contact Sipco, LLC or Ipco, LLC at 8215 Roswell Rd., Building 900, Suite 950, Atlanta, GA 303350, or at www.
sipocollc.com or www.intusiq.com.
SUPPLEMENTAL INFORMATION
For Limitations of Fire Alarm Systems,
please go to:
http://www.systemsensor.com/
en-us/Documents/I56-1558.pdf
Limitations of
Fire Alarm Systems
2 I56-6962-000
©2021. 1/19/2021
Fike®is a registered trademark of Fike Corporation. SWIFT®and System Sensor® are registered trademarks of Honeywell International, Inc.

Popular Monitor manuals by other brands

Dell P2722H user guide

Dell

Dell P2722H user guide

Acer 34e user guide

Acer

Acer 34e user guide

HP L1950 Service manual

HP

HP L1950 Service manual

Edge10 C172 user manual

Edge10

Edge10 C172 user manual

JVC DT-V17L3R instructions

JVC

JVC DT-V17L3R instructions

JVC GM-552 instructions

JVC

JVC GM-552 instructions

Sharp LL-T15G3 Operation manual

Sharp

Sharp LL-T15G3 Operation manual

LG Flatron L1922P user guide

LG

LG Flatron L1922P user guide

Impax 2000 Guide

Impax

Impax 2000 Guide

Sony SDM-H246W operating instructions

Sony

Sony SDM-H246W operating instructions

CTX PR1400F user guide

CTX

CTX PR1400F user guide

NEC SpectraView LCD2180 WideGamut LED user manual

NEC

NEC SpectraView LCD2180 WideGamut LED user manual

PSI Displays SDI Series user manual

PSI Displays

PSI Displays SDI Series user manual

Samsung PN17K Series Service manual

Samsung

Samsung PN17K Series Service manual

ViewSonic VE710b-1 Service manual

ViewSonic

ViewSonic VE710b-1 Service manual

Grundig GD-ML-DP2730HD quick guide

Grundig

Grundig GD-ML-DP2730HD quick guide