2Table of Contents
3 Lyra Screen Navigation
4 Home
6 Lights
7 Auto Gen Start Settings (AGS)
8 Climate Control
9 Settings
10 Settings/Mobile App
11 Settings/Network Diagnostics
13 Settings/Switch Panel Info
14 Floorplan Selection and Options
15 Wireless Switch Pairing
16 Service Mode
17 Vegatouch Mira Modules
18 Mira Setup
22 SSP17 Switch Panels
23 G12 DC Panels
24 Networking
25 Network Status Indicators
26 Mira NET LED Status Key
27 System Diagrams
1013 Elroy Drive
Middlebury, Indiana 46540
Phone: (574) 825-4600
Support@Fireflyint.com
Facebook @Fireflyintegrations

3
Tap any icon from the navigation bar to select the desired page. The currently selected page will always
be listed in the top corner of the screen.
Lyra Screen Navigation
Home
AGS
Lights
Climate
Settings
Navigation Menu

4
The Light Master controls all interior lights at once. When Light Master Off is pressed, it will remember
which lights were on. Then, when Light Master On is pressed, it will only turn on the lights that are in
memory. To turn on all lights again, press and hold Light Master On for at least one second.
*Troubleshooting –Memory is rewritten each time Light Master Off is pressed. In the case that it is
pressed twice in a row, it will remember that no lights were on and just touching Light Master On won’t
turn on any lights. Press and hold Light Master On to turn the lights back on.
Slide/Awning –This section of the screen will toggle between the Slide control or Awning control based
on the Parking Brake/Ignition inputs currently being received by the G12 panel.
Slide –Press and Hold EXT or RET to operate the Slide.
Awning –Tap the Awning button to fully extend or retract the awning.
Climate Control –Tap the arrows to select your desired temperature. The current temperature and
climate control mode will display on the home screen. A white fan graphic will represent Fan mode, a
blue snowflake will represent Air Conditioning, a red flame graphic will represent the Furnace. Auto
mode will display the graphic for the system that is currently running.
1
3
Home
1
2
2
3

5
The LP Tank readings are as follows:
Disconnected –above 97%. Percentage changes to
Disc and tank shows empty.
Full –75% to 97%. Percentage changes to Full and
tank shows accurate level.
Actual Level –Displays actual percentage and level
25 –97%.
Low –25%. Percent changes to Low and tank shows accurate level.
Button status –buttons will turn light blue when on and gray when off.
Battery Level Indicators - These graphics will indicate the battery voltage for the House and Chassis
batteries. The graphics will display Green while above 12V and Red while below 12V.
These graphics represent the percentage filled for
holding tanks.
Water Pump –Tap to toggle On/Off.
LP percentage remaining (shown
disconnected).
4
4
5
Generator Controls
The Generator display will show the total number
of generator hours accumulated as well as the
current operating status (running or stopped).
Generator hours are saved to the system, not to
the generator itself. Press and Hold the Gen
Hours Tally for 5 seconds to change the number of
Gen Hours being displayed.
Gen Start –Tap Start to start the generator.
Gen Stop –Tap Stop to stop the generator.
Tap to Enable/Disable AGS (Action Required).
5

6
This screen will control the lighting for the entire coach, including the exterior. Tap any button to turn
the desired light On/Off.
Lights with up/down arrows are dimmable. Press and hold these buttons to ramp the brightness up or
down. Tap the buttons to toggle On/Off.
Lights

7
Tap to Enable/Disable AGS (as described on page 5).
Trigger Options –Automatically start the generator using specified voltage settings
(Low Volts) or when A/C or Heat Pump starts (HVAC). Select one or both triggers.
If no triggers are selected, AGS will not run. Disable HVAC Load while connected to
shore power to keep the generator from starting.
Generator Hours Reset –Press and hold the accumulated hours tally for seven seconds to enter the
hours reset screen. This process should only be done after replacing or servicing the generator or to
sync the hours on the screen with the hour meter on the generator.
Start at Volts - The generator will start when the voltage drops to this set point
depending on “Time a Volts” setting below. (Range 10.5v –12.5v)
Time at Start Volts - The generator will start when the voltage drops to the Start at
Voltage for this specific amount of time. (Range 5 seconds –1 minute) 5 seconds –1
minute)
Stop at Volts - The generator will shut off when the voltage reaches this set point
depending on “Time at Stop Volts” setting below. (Range 13.2v –14.5v)
Time at Stop Volts - The amount of time required for the voltage to remain at “Stop at
Volts” level before the generator shuts off. (Range 5min –120 min)
Minimum Gen Run Time - Use the +/- buttons to set the minimum amount of time that
your generator will run once it has started. (Range 10min –30 min)0min –30min)
Maximum Gen Run Time - Use the +/- buttons to set the maximum amount of time that
your generator will run once it has started. (Range 120min –300min)
(Range 120min –240min)
–30min)
Gen Start Retries - Use the +/- buttons to set the number of tries that your generator
will retry to start. (Range 1-5 retries)
–30min)
Auto Gen Start Settings
1

8
Cool –Tap to operate the air conditioning. The A/C will run until the current temp reaches your desired
temp and then shut off.
Heat Pump –Tap to operate the Heat Pump. The Heat Pump will run until the current temp reaches
your desired temp and then shut off.
Furnace –Tap to operate the furnace. The furnace will run until the current temp reaches your desired
temp and then shut off.
Auto –Tap to put the system into Auto mode. The A/C or Heat Pump will automatically run to keep
your desired temperature consistent. Furnace may be selected manually to be used in addition to the
Heat Pump.
Vent Fan Controls –Tap Power to raise the lid and start the fan at medium speed. Tap a speed selection
if you’d prefer it to run faster or slower. Tap Lid Down to power off the fan and close the lid. Tapping
Lid Up will raise the lid but will not start the fan.
Fan Mode –The fan will operate by choosing
High or Low. Auto will turn the fan off. Fan
Mode is only available if HVAC is off.
Use the Arrows to select your
desired temperature by zone.
Current Temperature/Mode/Fan speed.
2
1
3
c
2
4
Climate Control
1
3
4
5
5

9
Settings
1
8
7
6
4
3
2
1
9
Tap to enter the Network Diagnostics page.
2
Navigate to the Switch Panel Info page.
3
Tap to enter the Vegatouch Mira connection screen.
4
Floorplan display.
Tap to select between 10 levels of Screen Brightness and Off.
5
6
8
Clean Mode - Disables touchscreen functionality (15 seconds) for the purpose of cleaning.
Tap the buttons to set the time or choose 24-hour time.
9
When Auto Dimming is enabled, the screen will enter sleep mode after 60 seconds of inactivity. Tap anywhere
on the screen to wake it up. Please note that even if Auto Dimming has been disabled, the screen will still enter
sleep mode after 4 hours of inactivity during daytime hours (5am –10:59pm) and after 15 minutes of inactivity
during night time hours (11pm-4:59am) as the result of a built in screen saver that cannot be disabled.
7
Tap the temperature units display to switch between Fahrenheit and Celsius.
Please note the GUI and Logic Controller versions and have these numbers available before calling Tech Support.
5

10
Vegatouch Mira is a wireless control module that easily connects to any Android or iOS device
to give total control to many electrical, electronic and mechanical systems in your coach. Pair
any device with the coach’s built-in interface to monitor and control these systems.
Settings/Mobile App

11
This screen will show the status of the Lyra screen and the G12 panel. It will also display any current
faults the system is experiencing. Tap the tabs at the bottom of the screen to visit the different
diagnostic pages.
Settings/Network Diagnostics
Current Faults
Green = Online

12
This screen will show which G12 Outputs are currently active.
This screen will show the current status of the Aircons and Vent Fan Controllers.
Active Output
Main Vent Fan Controller
Disconnected.

13
The color-coded Wireless Graphic and Signal Strength Value will identify the status of a wireless switch
panel.
•Green –Over 100 (Strong)
•Yellow –85-100 (Medium)
•Red –Less than 85 (Weak)
Red Wireless Graphic with a Zero reading –The switch is currently disconnected from the screen. It is
likely that the battery inside your switch panel needs replaced. The wireless switch panel in your coach
will illuminate a green LED whenever a button is pressed. If the LED on your switch panel does not
illuminate when you press a button on your switch, you will need to replace the 2032 coin cell battery.
If the LED is illuminating but the switch still won’t function, contact Coach House for technical support.
Settings/Switch Panel Info

14
Press and hold the floorplan box for 7 seconds to enter the
Floorplan/Options selection screen. From here, you’ll be
able to select the correct floorplan and any options that
are specific to the coach.
Floorplan Selection and Options

15
Red switch indicator with a zero reading –The switch is currently disconnected from the screen. It is
likely that the battery inside your switch panel needs replaced. The wireless switch panel in your coach
will illuminate a green LED whenever a button is pressed. If the LED on your switch panel does not
illuminate when you press a button on your switch, you will need to replace the 2032 coin cell battery.
If a new battery will not fix the issue, you might need to pair the switch panel to the screen.
Press and Hold a switch graphic for 3 seconds until the pairing screen appears.
Tap Start Pairing. You’ll have 30 seconds to press and hold any 2 buttons on the switch panel at the
same time for 5 seconds.
Tap Done once the pairing successful message appears. It may take up to 10 minutes for the battery
switch indicator to turn Green, but the switch should work instantly once paired.
r
1
1
2
3
Wireless Switch Pairing
2
3

16
This system features a Service Mode to be used by qualified technician. Once enabled, it will remove
the 5-second hold delays on:
•Gen Hours Reset
•Individual Wireless Switch Pairing
•Clear All Wireless Switch Pairing
•Floorplan Selection
To enable Service Mode, Press and hold the Settings button for 5 seconds until a yellow wrench appears
at the top right-hand corner of the screen (next to the time). Now, release your finger and the Warning
screen will appear. Once you tap enable, the wrench will turn Red.
To disable Service mode, tap the red wrench, then tap Disable from the warning screen.
Service Mode

17
Vegatouch Mira is a wireless control module that easily connects to any
Android or iOS device to give total control to many electrical, electronic and
mechanical systems in your coach. Pair any device with the coach’s built-in
interface to monitor and control every component.
Troubleshooting:
I CAN’T CONNECT TO MIRA WITH MY SMARTPHONE/TABLET.
Make sure that Bluetooth is enabled on your smartphone/tabletand follow
the setup instructionson the next page. Always make sure that you are
using the most current version of the Mira app. Update the app if
necessary.
WHEN I TRY TO CONNECT, THE SCREEN SAYS “SYNCING” AND NOTHING
HAPPENS (OR SAYS OUT OF RANGE).
Click on the settings page of your touchscreen and verify that your coach’s
floorplan is selected. If the floorplan is blank, Mira won’t be able to connect.
The network cable could also be faulty. Inspect the cable at both ends and replace it if
necessary. If the cabling and setup seem to be correct, contact Firefly Integrations about
possibly replacing the Mira module.
Blinking NET LED:
A blinking green NET LED on this module, please see page 26 of this manual.
Password Reset:
Reset the Mira’s password back to default (777777) by inserting a thin object, such as a
toothpick, into the small hole on the front of the module and pressing the internal reset button
for 5 seconds. You can also reset the password from the Touchscreen by navigating to
Settings/Mobile App and tapping Reset Pin to Default.
NET LED
Password Reset
Vegatouch Mira Modules

18
Notice: Make sure that Bluetooth is turned ON in your smart device
settings before proceeding.
Locate the Login Information:
The login informationcan be found by clicking
on the Mobile App button on the settings page
of the touchscreen or from the Mira module’s
label.
Download:
Download Vegatouch Mira from the Google Play store or the App Store. Once the download
has finished, install the app and open it.
Setup:
Tap SCAN to find the Mira Module’s signal. After scanning, any Mira Module in your area will
appear on the screen. Tap the ID # that matches the one on your Mira label. Enter the PIN
number from the Mira label and press AUTHENTICATE to connect to the system.
Mira Setup

19
Notice: iOS Setup Tips
Turn on Bluetooth to allow Vegatouch Mira to
connect to Accessories.
If you do not have Bluetooth turned ON in your iOS settings,
you will see this screen. Do not click OK, you must click
SETTINGS. Your Bluetooth Settings page will now appear, and
you should turn Bluetooth ON.
Notice: Android Setup Tips
Allow Vegatouch Mira to access this device’s location.
Mira will need to be allowed access to your location. Click ALLOW when you see this
screen.

20
App Settings:
Access the App Settings page by tapping the triangle (at the bottom of the screen) to expose the
Settings button. Tap the gear to visit the settings page.
Tap the Temperature Units selection to
choose between Fahrenheit and Celsius.
System Information and Mira Name.
Tap to disconnect your device from Mira.
Tapping Update Config will force a
download of the config from the cloud.
Tap to enter the Diagnostic Tools screen.