2-06 Timer Start: This feature is designed to allow the user to have the CM-900 automatically remote
start at the end of a selected timed cycle. It also be controlled by the thermister so it will start at a
specified temperature at the end of the timed cycle.
FO1 - 3 hour cycle: (4 minute runtime, 8 minute runtime for diesel) Once Timer Mode is enabled
(see feature 2-13) the CM-900 will wait 3 hours, remote start and run for 4 minutes unless the cold
start feature is enabled. If this is the case, the CM-900 will check the temperature once every 3
hours. If it is at or below the selected temperature, (see feature 2-08) it will start and run for 4
minutes. The same procedure will apply to the hot start feature. If there is any interaction with the
CM-900 after timer mode has been activated using the Firstech remote or accessory, timer mode
will be cancelled and must be re-started in order to start a new timed cycle.
FO2 - 2 hour repeat with cold starting: (runtime based on feature 2-07 option setting and cold
start setting based on feature 2-08) Note: 2 way LCD remote required. This option is designed to
monitor the temperature 2 hrs. After timer mode is set and start if it is at or below the preset cold
start temperature (see feature 2-08). This process will continue until the user manually starts or
remote starts the vehicle.
FO3 - Reserve runtime: (runtime based on feature 2-07 option setting) Note: 2 way LCD remote
required. This option will allow the user to set a predetermined time to remote start on the 2 way
LCD remote. Once the timer mode is activated it will start the countdown timer on the CM-900
based on the difference of time between what the remote clock is set to and the timer mode time is
set to. I.e. remote time reads 7:00pm and timer mode time is set to 7:00 am the CM-900 will
activate the timer mode to go for 12hours before it starts. Note: it is important that the remote time
is as accurate as possible when activating the timer mode to ensure that it will start at the desired
time. If there is any interaction with the vehicle or system after timer mode has been activated it will
cancel the timer.
FO4 - 24 hour repeat with cold starting: (runtime based on feature 2-07 option setting and cold
start setting based on feature 2-08) Note: 2 way LCD remote required. This option is designed to
monitor the temperature 24 hrs. After timer mode is set and start if it is at or below the preset cold
start temperature (see feature 2-08). This process will continue until the user manually starts or
remote starts the vehicle.
2-07 Remote Start Runtime: This feature consists of four different settings for the remote start run time.
FO1 - 15 minutes (default)
FO2 - 25 minutes
FO3 - 45 minutes
FO4 - 3 minute runtime: to comply with any local idle laws prohibiting extended idle times.
2-08 Cold start Temperature: This feature allows the user 4 different temperature settings for cold start
operation FO1 - 14°F/-10°C: will activate the start sequence at the end of the time cycle (set by
feature 2-06 option setting) if temperature is at or below this temperature.
FO2 - -4°F/-20°C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or below this temperature.
FO3 - 23° F/-5° C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or below this temperature.
FO4 - 5° F/-15° C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or below this temperature.
2-09 Hot Start Temperature: This feature allows the user 4 different settings for hot start operation