Flocca Flow - Quick Maintenance Guide
6. CHECK SETTINGS
»From Main Screen, go to Settings
»Check input settings are correct as per setup
7. CALIBRATE ULTRASONIC
8. MANUAL (TEST) DOSE
9. PRIOR TO STORAGE
»The ultrasonic is very sensitive and this calibration should be
performed regularly. The value can become inaccurate from the
smallest movement in the pipe or the sensor itself
»From Main Screen, go to Manual Calibrate
»Select Calibrate Ultrasonic
»Enter Actual Depth (mm) as 0
»Select Update Calibration
»Actual depth would only ever have a value if there is water standing
in the pipe at time of installation
»Place measuring jug (min. 1 L at outlet hose)
»From Main Screen, go to Manual/Calibrate
»Dose Fixed Volume (L) – enter 0.5 L
»Press Start (No need to press Stop, dosing will stop automatically)
»This first dose will fill any voids in the outlet assembly and hose
»Return chemical to IBC and place measuring jug at outlet again
»Dose Fixed Volume (L) – enter 0.5 L. Press Start
»No need to press Stop, dosing will stop automatically
»Check that volume in jar matches fixed volume, within 10%
»Press Home - finished, your Flocca is good to go
Whilst unit is still setup, it is recommended to rinse out solenoid and
flow meter to remove chemical residue:
»Close IBC valve and detach camlock
»Whilst flow meter and solenoid still attached to controller (but not
to IBC), perform dummy manual test dose to open solenoid, using
value of 1L or more
»With jug pour water through flow meter and solenoid to rinse out
and remove residue
»Repeat if needed
»Dry with towel and pack away
flocca.com.au 2