Fluke 805 FC User manual

May 2012, Rev. 2, 12/14
© 2012-2014 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
805/805 FC
Vibration Meter
Users Manual
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is
one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to
the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product
which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation
or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has
been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to
extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke
authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of
repair/replacement parts when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective
product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the
product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk
for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling,
including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components,
Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be
returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping
Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR
LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or
consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is
held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or
enforceability of any other provision.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

i
Table of Contents
Title Page
Introduction.................................................................................................................... 1
How to Contact Fluke .................................................................................................... 1
Safety Information.......................................................................................................... 2
Symbols......................................................................................................................... 3
Accessories ................................................................................................................... 3
Specifications ................................................................................................................ 3
Before You Start ............................................................................................................ 5
Unpack and Inspect .................................................................................................. 5
Storage ..................................................................................................................... 5
Battery ...................................................................................................................... 5
Controls and Connections......................................................................................... 6
Measurement Status LEDs ....................................................................................... 7
Power On.................................................................................................................. 8
Power Off.................................................................................................................. 8
How to Operate.............................................................................................................. 9
Navigation................................................................................................................. 9
Meter Configuration .................................................................................................. 9
Units..................................................................................................................... 10
Time ..................................................................................................................... 10
Date ..................................................................................................................... 11
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
ii
Backlight Timeout................................................................................................. 11
Language ............................................................................................................. 11
Device Info ........................................................................................................... 12
Battery Selection .................................................................................................. 12
Emissivity Selection.............................................................................................. 12
Power Saving............................................................................................................ 13
Flashlight................................................................................................................... 13
Accessory Connectors .............................................................................................. 13
External Sensor.................................................................................................... 14
Audio (805 only) ................................................................................................... 15
USB...................................................................................................................... 16
About Measurements..................................................................................................... 17
Crest Factor+ (High Frequency Measurement)......................................................... 18
Quick Measurement .................................................................................................. 19
Overall Vibration (Low Frequency) Measurement with Severity Scale...................... 20
Machine Category ................................................................................................ 21
Create New Setup..................................................................................................... 22
Add to Setup ........................................................................................................ 24
Enable Fluke Connect (805 FC only) ........................................................................ 24
How to Save a Measurement.................................................................................... 25
Auto Save............................................................................................................. 25
Save to Existing Setup ......................................................................................... 25
Save to Current Setup.......................................................................................... 26
Save to New Setup............................................................................................... 26
How to Recall a Setup for Measurements................................................................. 27
Access to Memory ......................................................................................................... 28
View All Data............................................................................................................. 28
View Setups .............................................................................................................. 29
Edit Setups................................................................................................................ 29
Clear All Data............................................................................................................ 30
Interpret Results ............................................................................................................ 31
Severity Scale ........................................................................................................... 31
ISO 10816 Standards................................................................................................ 32
Trending.................................................................................................................... 32
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Vibration Meter
Contents (continued)
iii
ISO 10816-1......................................................................................................... 32
ISO 10816-3......................................................................................................... 33
ISO 10816-7......................................................................................................... 33
Export Data.................................................................................................................... 34
General Maintenance .................................................................................................... 37
Care .......................................................................................................................... 37
How to Clean ............................................................................................................ 37
Battery Replacement ................................................................................................ 38
Firmware Upgrades ....................................................................................................... 39
How to Troubleshoot...................................................................................................... 40
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
iv
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

v
List of Tables
Table Title Page
1. Symbols ................................................................................................................................ 3
2. Accessories .......................................................................................................................... 3
3. Keypad and Connectors ....................................................................................................... 6
4. LED Status............................................................................................................................ 7
5. Crest Factor+........................................................................................................................ 18
6. Severity Scale....................................................................................................................... 31
7. Vibration Severity - ISO 10816-1 .......................................................................................... 32
8. Troubleshooting .................................................................................................................... 40
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
vi
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

vii
List of Figures
Figure Title Page
1. Meter Controls and Connections .......................................................................................... 6
2. Flashlight .............................................................................................................................. 13
3. External Sensor Connection (805) ........................................................................................ 14
4. Audio Connection (805 only)................................................................................................. 15
5. Meter to PC Connection (805) .............................................................................................. 16
6. Measurement Display ........................................................................................................... 17
7. Import Database ................................................................................................................... 34
8. Plot Options .......................................................................................................................... 35
9. Data Plot Graph .................................................................................................................... 36
10. Battery Replacement ............................................................................................................ 38
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
viii
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

1
Introduction
The 805/805 FC Vibration Meter (the Meter or Product) is
a screening tool for bearings and overall vibration
measurements on machines. The Meter includes these
features:
•Overall vibration measurement
•Bearing health measurement with Crest Factor+
•On-screen severity scales
•Acceleration, Velocity, and Displacement units of
measure
•Temperature measurement with spot IR sensor
•Test results export to MS Excel template
•Belt Holster
•IP54
•Language support for Chinese (Simplified), Danish,
Dutch, English, Finnish, French, German, Italian,
Japanese, Norwegian, Portuguese (Brazilian), Russian
Spanish, Swedish, and Turkish
•Audio output (805 only)
•Flashlight
•Stores up to 3,500 records
•USB
support
•Storage/shipping case
•External accelerometer support
•Wireless data transmission of most recent
measurement for use with Fluke ConnectPhone App
(805 FConly)
How to Contact Fluke
To contact Fluke, call one of the following telephone
numbers:
•Technical Support USA: 1-800-44-FLUKE
(1-800-443-5853)
•Calibration/Repair USA: 1-888-99-FLUKE
(1-888-993-5853)
•Canada: 1-800-36-FLUKE (1-800-363-5853)
•Europe: +31 402-675-200
•Japan: +81-3-6714-3114
•Singapore: +65-6799-5566
•Anywhere in the world: +1-425-446-5500
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
2
Safety Information
A Warning identifies the conditions and procedures that
are dangerous to the user. A Caution identifies the
conditions and procedures that can cause damage to the
Product or the equipment under test.
Warning
To prevent possible electrical shock, fire, or
personal injury:
•Carefully read all instructions.
•Do not touch hazardous voltages with the
Product. These voltages could cause injury
or death.
•Use the Product only as specified, or the
protection supplied by the product can be
compromised.
•Examine the case before you use the
Product. Look for cracks or missing
plastic.
•Make sure the battery is securely in
position before operation.
•Do not use the Product around explosive
gas, vapor, or in damp or wet
environments.
•Comply with local and national safety
codes. Use personal protective equipment
(approved rubber gloves, face protection,
and flame-resistant clothes) to prevent
shock and arc blast injury where
hazardous live conductors are exposed.
To prevent personal injury from the infrared
thermometer:
•See emissivity information for actual
temperatures. Reflective objects result in
lower than actual temperature
measurements. These objects pose a burn
hazard.
•Do not keep the product in operation and
unattended at high temperatures.
To prevent personal injury when near rotating
equipment:
•Use caution around rotating equipment.
•Keep cords and straps contained.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Vibration Meter
Symbols
3
Symbols
Table 1 is a list of symbols on the Meter and in this
manual.
Table 1. Symbols
Symbol Description
Important information. See manual.
Hazardous voltage.
Conforms to requirements of European Union and
European Free Trade Association.
Conforms to relevant Australian EMC standards
This product complies with the WEEE Directive
(2002/96/EC) marking requirements. The affixed
label indicates that you must not discard this
electrical/electronic product in domestic household
waste. Product Category: With reference to the
equipment types in the WEEE Directive Annex I,
this product is classed as category 9 "Monitoring
and Control Instrumentation” product. Do not
dispose of this product as unsorted municipal
waste. Go to Fluke’s website for recycling
information.
Battery or battery compartment.
Low battery when shown on display.
Conforms to relevant South Korean EMC
standards.
Accessories
Table 2 is a list of the accessories available for the Meter.
Table 2. Accessories
Description PN
Belt Holster 4106625
Storage/Shipping Case 4094432
Battery Door 4059351
USB Cable 3563901
Specifications
Sensor
Sensitivity (typical) ..............................100 mV / g ±10 %
Measurement Range .......................... 0.01 g to 50 g
Frequency Range ...............................10 Hz to 1,000 Hz
and 4,000 Hz to 20,000 Hz
Resolution ........................................... 0.01 g
Accuracy (typical)................................ At 100 Hz: ±5 % of measured
value
Amplitude Units
Acceleration ................................ g, m/sec2
Velocity ....................................... in/sec, mm/sec
Displacement .............................. mils, μm
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
4
Infrared Thermometer
Temperature Measurement
Range ................................................. -20 °C to 200 °C (-4 °F to 392 °F)
Accuracy (typical)
-20 °C to 120 °C
(-4 °F to 248 °F) .............................. ±2 °C (4 °F)
120 °C to 160 °C
(248 °F to 320 °F) ........................... ±3 °C (6 °F)
160 °C to 200 °C
(320 °F to 392 °F) ........................... ±4 °C (7 °F)
Note
The specified accuracy is applicable only when the Meter is in
thermal equilibrium with its environment. Accuracy is not
specified when the target temperature is more than 20
°
C
(36
°
F) below the temperature of the Meter.
Focal length ........................................ Fixed, at ~3.8 cm (1.5 in)
External Sensor
Frequency Range ............................... 10 Hz to 1,000 Hz
Bias Voltage (to supply power) ........... 20 V DC to 22 V DC
Bias Current (to supply power) ........... 5 mA
Note
Fluke supports, but does not provide, external sensors.
Vibration Meter
Low Frequency Range
(overall measurement)........................ 10 Hz to 1,000 Hz
High Frequency Range
(CF+ measurement)............................ 4,000 Hz to 20,000 Hz
Vibration Limit .................................... 50 g peak (100 g peak-peak)
Battery Type ....................................... AA (2) lithium non-rechargeable
3 V dc
Battery Life
805 .................................................. 250 measurements
805 FC, Fluke Connectenabled ..210 measurements
A/D Converter ..................................... 16-bit
Sampling Rate
Low Frequency ............................... 20,000 Hz
High Frequency............................... 80,000 Hz
Signal to Noise Ratio ..........................80 dB
Real Time Clock Backup..................... Coin Battery
Size (L x W x H) .................................. 24.1 cm x 7.1 cm x 5.8 cm (9.5 in x
2.8 in x 2.3 in)
Weight.................................................0.40 kg (0.89 lb)
Connectors (805) ................................USB Mini-B 7-pin, Stereo Audio
Output Jack (3.5 mm Audio Plug),
External Sensor Jack (SMB
connector)
Connectors (805 FC) ..........................USB Mini-B 7-pin, External Sensor
Jack (SMB connector)
Firmware
External Interfaces .............................. USB 2.0 (full speed)
communication
Data Capacity .....................................Database on internal flash memory
Upgrade .............................................. through USB
Memory ............................................... Up to 3,500 measurements
Environmental
Operating Temperature....................... -20 °C to 50 °C (-4 °F to 122 °F)
Storage Temperature..........................-20 °C to 60 °C (-4 °F to 140 °F)
Operating Humidity .............................10 % to 95 % RH (non-
condensing)
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Vibration Meter
Before You Start
5
Operating/Storage Altitude ................. Sea Level to 3,048 meters
(10,000 feet)
IP Rating ............................................. IP54
Vibration Limit..................................... 500 g peak
Drop Test ............................................ 1 meter
Electromagnetic Environment
IEC 61326-1: Portable
FCC ................................................ CFR Title 47, Part 15, Subpart B
Korea (KCC) ................................... Class A Equipment (Industrial
Broadcasting & Communication
Equipment)
This product meets requirements for industrial (Class A)
electromagnetic wave equipment and the seller or user should take
notice of it. This equipment is intended for use in business
environments and is not to be used in homes.
Before You Start
This section helps you to know the Meter parts, controls,
connections, and status LEDs.
Unpack and Inspect
Carefully unpack and inspect the:
•Vibration
Meter
•Storage
case
•USB Cable
•Quick Reference Guide
•Belt Holster
•AA (2) Lithium non-rechargeable batteries
Storage
When not in use, always keep the Meter in the supplied
storage case. The custom interior of the case supplies
protection for the Meter, documentation, and accessories.
Battery
Before you use the Meter for the first time, install the two
AA lithium non-rechargeable batteries (included). See
Battery Replacement on page 38 for more information.
The Meter also operates on two AA alkaline (3 V)
batteries. Due to short battery life, alkaline batteries are
not recommended.
Note
Set the battery type in the Device Settings menu.
See page 12.
shows on the display when battery power is low.
Replace the batteries before you continue to use the
Meter.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
6
Controls and Connections
Figure 1 shows the location of the controls and
connections for the Meter. Table 3 is a key.
1
2
3
4
5
7
8
9
10
11
12
15
18
17
14
13
14
13
6
16
gqi01.eps
Figure 1. Meter Controls and Connections
Table 3. Keypad and Connectors
Item Control
LCD
Power on/off
Measure
Navigation
Enter
Save
Setup
Connector cover
Status LED
Memory
Flashlight on/off
Backlight on/off
USB port
External sensor port
Audio port (805 only)
Vibration sensor
IR temperature sensor
Flashlight
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Vibration Meter
Before You Start
7
Measurement Status LEDs
The Meter has a status light for visual feedback about the
measurement. Green and red LEDs show the
measurement status and that a good measurement has
been taken. Table 4 is a list of the status as the LED
changes color.
Table 4. LED Status
90˚
gqi07.eps
Status Description
Green Off Push . Meter is ready for data
measurement.
Green On
Push the sensor tip onto the test surface,
on solid metal, as close as possible to the
bearing. Apply the compression force until
green LED is off.
Green Off Data measurement is complete.
Red On Error, insufficient force or time duration, no
data measurement.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
8
Power On
Push to turn on the Meter. See Table 3 for the control
location.
Note
Before you use the Meter for the first time, install
the new batteries (see Battery Replacement on
page 38).
When the Meter is turned on, the default Measurement
screen shows on the Meter.
gqi49.jpg
Power Off
A soft shutdown is the preferred method to turn off the
Meter:
1. Push .
2. At the prompt, select Yes.
3. Or, select No to continue with operation.
If the Meter locks up or becomes inoperable, a hard
shutdown can be used to turn off the Meter:
Note
Use a hard shutdown only as a last recourse as it
can cause data loss. After a hard shutdown, start
the Meter and verify the data in Memory.
1. Push and hold for more than 2 seconds.
2. Push to restart the Meter.
If Meter does not restart or the problem persists,
contact Fluke.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Vibration Meter
How to Operate
9
How to Operate
This section is about the operation of the Meter. It includes
measurement tips and step-by-step instructions.
Navigation
For general operation:
moves the cursor through the menu options
and edits the options
opens next menu or sets the selection
updates the Meter with a new selection setting
recalls the previous menu
Each menu has navigation hints for its content at the
bottom of the screen.
Meter Configuration
The Setup menu is how you change the configuration of
the Meter. You can change these Device Settings:
•Units
•Time
•Date
•Backlight Timeout
•Language
•Device Info
•Battery Selection
To open Device Settings:
1. Push to view the Setup screen.
2. Push
and to highlight Device Settings from
the menu. This opens a list of all available options.
3. Push
to open the menu.
4. Push and to highlightan option.
5. Push
to open the menu.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

805/805 FC
Users Manual
10
Units
The units of measure are adjustable for different
standards.
To set from the Device Settings menu:
1. Push and to highlight Units.
2. Push
to open menu for units. The current
setting is highlighted.
3. Push and to highlight the unit to change.
4. Push
to open menu with options for that
unit. The current setting is highlighted.
5. Push
to update the Meter and exit the
menu.
6. Push and to move to the next page for more
options.
Time
To set the time format:
1. Push and to highlight the format as 12 hr or
24 hr.
2. Push to set the option.
To set the time:
1. Push and to highlight hour, minute, or
second.
2. Push to enable the edit.
3. Push
and to make a change.
4. Push to set the option.
5. Push
and to highlight am or pm.
6. Push
to set the option.
gqi57.jpg
7. Push to update the Meter and exit the
menu.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
This manual suits for next models
1
Table of contents
Other Fluke Measuring Instrument manuals

Fluke
Fluke i30s User manual

Fluke
Fluke CertiFiber Pro User manual

Fluke
Fluke 635 User manual

Fluke
Fluke E-DWT-H User manual

Fluke
Fluke 80i-600 User manual

Fluke
Fluke IRR1-SOL User manual

Fluke
Fluke 8050A User manual

Fluke
Fluke i30s User manual

Fluke
Fluke Datapaq Furnace Tracker User manual

Fluke
Fluke OptiView User manual

Fluke
Fluke 301A User manual

Fluke
Fluke i400s-EL User manual

Fluke
Fluke DP120 User manual

Fluke
Fluke 3000A Flex 4 User manual

Fluke
Fluke i400s Use and care manual

Fluke
Fluke 1630-2 User manual

Fluke
Fluke 414D User manual

Fluke
Fluke 772 Use and care manual

Fluke
Fluke VR1710 User manual

Fluke
Fluke RUSKA 2456-LEM User manual