Fluke i400s-EL User manual

i400s-EL
AC Current Clamp
Instructions
Introduction
The i400s-EL (the Product) is an ac current clamp that is compatible with
Fluke 173x Power Loggers and 174x Power Quality Loggers.
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers:
• Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
• Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
• Canada: 1-800-36-FLUKE (1-800-363-5853)
• Europe: +31 402-675-200
• Japan: +81-3-6714-3114
• Singapore: +65-6799-5566
• China: +86-400-921-0835
• Brazil: +55-11-3530-8901
• Anywhere in the world: +1-425-446-5500
Or, visit Fluke’s website at www.uke.com.
To register your product, visit http://register.uke.com.
To view, print, or download the latest manual supplement, visit
http://us.uke.com/usen/support/manuals.
PN 4974033
April 2018
© 2018 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies.
Product specications are subject to change without notice.
Safety Information
A Warning identies conditions and procedures that are dangerous to
the user. A Caution identies conditions and procedures that can cause
dameage to the Product or the equipment under test.
 Warning
To prevent electrical shock, re, or personal injury:
• Read all safety information before you use the Product.
• Do not alter the Product and use only as specied, or the
protection supplied by the Product can be compromised.
• Comply with local and national safety codes. Use personal
protective equipment (approved rubber gloves, face protection,
and ame-resistant clothes) to prevent shock and arc blast
injury where hazardous live conductors are exposed.
• Do not exceed the Measurement Category (CAT) rating of the
lowest rated individual component of a Product, probe, or
accessory.
• Before each use, examine the Product. Look for cracks or
missing pieces of the clamp housing or output cable insulation.
Also look for loose or weakened components. Carefully
examine the insulation around the jaws.
• Use caution around bare conductors or bus bars. To prevent
electrical shock, do not touch the conductor.
• Hold the Product behind the tactile barrier.
• Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
• Do not use the Product around explosive gas, vapor, or in
damp or wet environments.
• Do not use the Product if it is altered or damaged.
• Do not make connections on hazardous live conductors in
damp or wet environments.
• Limit operation to the specied measurement category, voltage,
or amperage ratings.
Measurement Considerations
Observe the following guidelines when making measurements (see
Table 1):
• Center the conductor inside the Product.
• Make sure the Product is perpendicular to the conductor.
• For optimal reading, make sure the conductor is positioned between
the alignment marks on the jaws of the Product.
• Avoid taking measurements close to other current-carrying
conductors.
Symbols
The table below is a list of symbols used on the Product and in this
document.
Symbol Description
WARNING - RISK OF DANGER. Consult user documentation.
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
Consult user documentation.
Double Insulated
Application around and removal from uninsulated hazardous live
conductors is permitted.

Measurement Category III is applicable to test and measuring circuits
connected to the distribution part of the building’s low-voltage MAINS
installation.

Measurement Category IV is applicable to test and measuring
circuits connected at the source of the building’s low-voltage MAINS
installation.
Conforms to European Union directives.
Certied by CSA Group to North American safety standards.

This product complies with the WEEE Directive marking
requirements. The afxed label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex I, this product is classed as category 9
“Monitoring and Control Instrumentation” product. Do not dispose of
this product as unsorted municipal waste.
Operation
To use:
1. Connect the clamp cable to the current inputs on the measurement
instrument. The instrument automatically recognizes the clamp and
selects the default range of the instrument for the probe.
2. Make sure the measurement instrument is set to the correct range.
3. Connect the jaws around the conductor to be measured.
 Warning
To prevent electrical shock, re, or personal injury, hold the
Product behind the tactile barrier. See Table 1.
Table 1. i400s-EL Setup
AD
B
C
E
F
Item Description
ASingle Current Carrying Conductor
BLoad Direction Arrow
CAlignment Marks
DTactile Barrier
E2 m (6.6 ft) Output Cable
FConnector
Maintenance
 Warning
To prevent electrical shock, re, or personal injury:
• Before each use, examine the Product. Look for cracks or
missing pieces of the clamp housing or output cable insulation.
Also look for loose or weakened components. Carefully
examine the insulation around the jaws.
• Do not use the Product if it is altered or damaged.
If the Current Clamp does not work or perform properly:
1. Inspect the jaw mating surface for cleanliness. If any foreign material
is present, the jaw will not close properly and measurement errors
will result.
2. Verify that the function selection and range on the measurement
instrument are correct and adjusted to the sensitivity of the Current
Clamp.
Cleaning
Periodically wipe the case with a damp cloth and mild detergent.
Caution
To avoid damaging the Current Clamp, do not use abrasives
or solvents to clean the clamp.
Open the jaws and wipe the magnetic pole pieces with a lightly oiled
cloth. Do not allow rust or corrosion to form on the magnetic core ends.
Specications
Measuring Range ........................... 400 mA ac to 40 A ac / 4 A ac to 400 A ac
Crest Factor.................................... ≤3
Accuracy at Reference
Condition[1] ...................................... ±0.5% of reading
[1] Reference Condition:
• 400 A 50/60 Hz
• Environmental: 23 °C ±5 °C, no external electrical/magnetic eld, RH 65 %
• Primary conductor in center position
Accuracy 174x + Clamp
400 A range................................ ±(0.7 % of reading + 0.1 % of range)
40 A range.................................. ±(2 % of reading + 0.2 % of range)
Phase Shift
<400 mA..................................... unspecied
400 mA to 1 A............................. < ±3.5°
1 A to 2 A.................................... < ±2.5°
2 A to 10 A.................................. < ±1.5°
10 A to 400 A.............................. < ±1°
Temperature Coefcient over
Operating Temperature Range ....... 0.01 % of reading / °C
0.0056 % of reading / °F
Inuence of Adjacent Conductor..... ≤9 mA/A (@ 50/60 Hz)
Inuence of Conductor Position
in Jaw Opening............................... ±1.0 % of reading + 0.05 A
Bandwidth....................................... 10 Hz to 2.5 kHz
Safety
General ...................................... IEC 61010-1: Pollution Degree 2
Measurement............................. IEC 61010-2: CAT III 1000 V/ CAT IV 600 V
Size (H x W x L).............................. 150 mm x 70 mm x 30 mm
(6 in x 2.8 in x 1.2 in)
Maximum Conductor Size .............. 32 mm (1.2 in)
Output Cable Length ...................... 2 m (6.6 ft)
Weight ............................................ 272 g (9.6 oz)
Temperature
Operating ................................... 0 °C to 50 °C (32 °F to 122 °F)
Non-operating ............................ -20 °C to +60 °C (-4 °F to +140 °F)
Relative Humidity, operating........... 10 °C to 30 °C: 95 %
30 °C to 40 °C: 75 %
40 °C to 50 °C: 45 %
Operating Altitude........................... 2000 m (6500 ft) up to 4000 m (13 000 ft) derate
to CAT II 1000 V / CAT III 600 V / CAT IV 300 V
Storage Altitude .............................. 12 km (40 000 ft)
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one
year from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination,
or abnormal conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Fluke’s behalf. To obtain service during the warranty
period, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or limitation
of an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
ООО «Флюк СИАЙЭС»
125167, г. Москва,
Ленинградский проспект дом 37,
корпус 9, подъезд 4, 1 этаж
11/99

Other Fluke Measuring Instrument manuals

Fluke 374 FC User manual

Fluke

Fluke 374 FC User manual

Fluke 301A User manual

Fluke

Fluke 301A User manual

Fluke OptiFiber Pro User manual

Fluke

Fluke OptiFiber Pro User manual

Fluke 43B User guide

Fluke

Fluke 43B User guide

Fluke 80i-110s User manual

Fluke

Fluke 80i-110s User manual

Fluke VIBGUARD IIoT User manual

Fluke

Fluke VIBGUARD IIoT User manual

Fluke 323 PLUS User manual

Fluke

Fluke 323 PLUS User manual

Fluke 365 User manual

Fluke

Fluke 365 User manual

Fluke 369 User manual

Fluke

Fluke 369 User manual

Fluke 317 User manual

Fluke

Fluke 317 User manual

Fluke 435-II User manual

Fluke

Fluke 435-II User manual

Fluke PG9000 Series User manual

Fluke

Fluke PG9000 Series User manual

Fluke Victoreen 451P User manual

Fluke

Fluke Victoreen 451P User manual

Fluke v3000 FC Use and care manual

Fluke

Fluke v3000 FC Use and care manual

Fluke 922 User manual

Fluke

Fluke 922 User manual

Fluke 373 User manual

Fluke

Fluke 373 User manual

Fluke SMFT-1000 Use and care manual

Fluke

Fluke SMFT-1000 Use and care manual

Fluke 377 Use and care manual

Fluke

Fluke 377 Use and care manual

Fluke 772 Use and care manual

Fluke

Fluke 772 Use and care manual

Fluke RUSKA 2482 User manual

Fluke

Fluke RUSKA 2482 User manual

Fluke OptiView III Series User manual

Fluke

Fluke OptiView III Series User manual

Fluke i410 User manual

Fluke

Fluke i410 User manual

Fluke Micro-Bath 7102 User manual

Fluke

Fluke Micro-Bath 7102 User manual

Fluke 374 User manual

Fluke

Fluke 374 User manual

Popular Measuring Instrument manuals by other brands

TESTO 605-H1 instruction manual

TESTO

TESTO 605-H1 instruction manual

BRONKHORST FLEXI-FLOW Compact quick start guide

BRONKHORST

BRONKHORST FLEXI-FLOW Compact quick start guide

Motec PLM user manual

Motec

Motec PLM user manual

Simco-Ion FMX-004 user manual

Simco-Ion

Simco-Ion FMX-004 user manual

Heyuan Intelligence DZ81-MA3UI5C user manual

Heyuan Intelligence

Heyuan Intelligence DZ81-MA3UI5C user manual

Watts BLUCHER Connected Roof User manual & installation guide

Watts

Watts BLUCHER Connected Roof User manual & installation guide

J.A. Woollam M-2000 Hardware manual

J.A. Woollam

J.A. Woollam M-2000 Hardware manual

Makita SK103P user manual

Makita

Makita SK103P user manual

Amprobe THWD-5 user manual

Amprobe

Amprobe THWD-5 user manual

Delta DVP04TC-H2 instruction sheet

Delta

Delta DVP04TC-H2 instruction sheet

Foxtech TEMPHAWK user manual

Foxtech

Foxtech TEMPHAWK user manual

Lovato DME D122MID installation manual

Lovato

Lovato DME D122MID installation manual

Maurer 97771 user manual

Maurer

Maurer 97771 user manual

HEIDENHAIN ERA 4201 Mounting instructions

HEIDENHAIN

HEIDENHAIN ERA 4201 Mounting instructions

AEMC 193-24-BK user manual

AEMC

AEMC 193-24-BK user manual

Elster A3 ALPHA user manual

Elster

Elster A3 ALPHA user manual

Milltronics HydroRanger Plus instruction manual

Milltronics

Milltronics HydroRanger Plus instruction manual

KABI 40385 operating manual

KABI

KABI 40385 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.