5128A
Safety Information
2
• Do not use the Product if it operates
incorrectly.
• Do not operate the Product with covers
removed or the case open. Hazardous
voltage exposure is possible.
• Use only specified replacement parts.
• Use only specified replacement fuses.
• Have an approved technician repair the
Product.
• Empty the reservoir before shipping the
Product.
• Do not overfill the reservoir.
For safe operation and maintenance of the
Product:
• Turn off the Product and remove the mains
power cord. Stop for 2 minutes to let the
internal circuits discharge before you open
the fuse door or remove Product covers.
Symbols
The symbols used in this manual and on the Product are
shown in Table 1.
General Specifications
AC mains voltage ...............................100 V to 240 V ±10 %,
47 Hz to 63 Hz
Power consumption ............................ 300 VA
Required test fluid............................... distilled water
Warm-up period to meet
specifications.......................................... Twice the time since last
warmed up, to a maximum of
30 minutes
Internal humidifier warm-up period
(time for “HEATING” to go off) ............30 minutes (Typical)
Mains Fuse Rating.............................. F 4A 250 V (fast blow)
Operating ambient relative
humidity range, 18 °C to 28 °C ..........up to 80 % RH
Storage temperature and
relative humidity..................................-20 °C to 50 °C, 0 % to 95 %
RH, non-condensing
Transducer Power Output ..................12 V dc, 1 A maximum,
fuse: F 1A 250V (fast blow)
Computer Interface… .........................USB
Safety ................................................. IEC 61010-1, Installation
Category II, Pollution degree
2,Indoor use only
Altitude................................................ 2000 m
Electromagnetic Compatibility (EMC)
International ............................................ IEC 61326-1: Controlled
Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary for the
internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than
domestic and those directly connected to a low-voltage power supply
network that supplies buildings used for domestic purposes. There may
be potential difficulties in ensuring electromagnetic compatibility in other
environments due to conducted and radiated disturbances.
Korea (KCC) ......................................... Class A Equipment (Industrial,
Broadcasting,&
Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and not to be
used in homes.
USA (FCC)............................................ 47 CFR 15 subpart B. This
product is considered an
exempt device per clause
15.103.
Weight
Chassis Only .................................... 15 kg (33 lbs)
Table 1: Symbols
Symbol Description
WARNING. HAZARDOUS VOLTAGE. Risk of
electric shock.
WARNING. RISK OF DANGER.
Consult user documentation.
Certified by CSA Group to North American
safety standards.
Conforms to European Union directives.
Conforms to relevant Australian EMC
standards.
Fuse
Conforms to relevant South Korean EMC
Standards.
This product complies with the WEEE
Directive marking requirements. The affixed
label indicates that you must not discard this
electrical/electronic product in domestic
household waste. Product Category: With
reference to the equipment types in the WEEE
Directive Annex I, this product is classed as
category 9 "Monitoring and Control
Instrumentation" product. Do not dispose of
this product as unsorted municipal waste.