Fly Dragon Light Sky TX1920-HC User manual

Please read these user manual carefully before use!Please read these user manual carefully before use!
TX1920-HC
E-mail:
n
地址:广州市花都区秀全街云峰路43号
Address: No. 43, Yunfeng Road, Xiuquan Street,
Huadu District, Guangzhou, China

Congratulations on choosing our company product! We thank you for your custom.
◆Please note that this product, as all the others in the rich my company range, has
been designed and made with total quality to ensure excellent performance and
best meet your expectations and requirements.
◆Carefully read this user manual in its entirety and keep it safe for future reference.
It is essential to know the information and comply with the instructions given in this
manual to ensure the fitting is installed, used and serviced correctly and safely.
◆My company disclaims all liability for damage to the fitting or to other property or
persons deriving from installation, use and maintenance that have not been carried
out in conformity with this user manual, which must always accompany the fitting.
◆My company reserves the right to modify the characteristics stated in this user
manual at any time and without prior notice.
Contents
1. Safety information........................................................................................................2
2. Technical information...................................................................................................4
3. Attachment and body size..................................................................................6
4. Installation and connecting.......................................................................................7
5. Control panel..............................................................................................................10
6. Menu setting...............................................................................................................11
7. Channel function.........................................................................................................13
8. Circuit connecting diagram......................................................................................14
9. Cleaning and maintenances.......................................................................................15
10.Troubeshooting..........................................................................................................16
11.Duty exonerative and copyright protection............................................................17

Ensure a minimum clearance of 0.2m around the cooling fans and ventilation.
Please do not install the fixture onto combustible surface.
The double insulation between the LV power supply and the control conductor on the fixture.
The fixture is intended for indoor application.
2
ta40℃
40
Do not expose the front glass to sunlight or other strong light source from any angle.
Lenses can focus the sun's rays inside the fixture, creating a potential fire hazard.
■Mounting surface and fire protection
Keep all combustible materials at least 20 cm away from the fixture.
■This lighting fixture is for professional use only - it is not for household use.
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
The safety chain must be prgperly hooked onto the fitting and secured to the framework.
When suspending the fixture, ensure that the supporting structure and all hardware used
can hold at least 10 times the weight of all the devices they support.
SAFETY INFORMATION

The products referred to in this manual conform to the European Community Directives to which
they are subject:
Low Voltage 2014/35/EU
Electromagnetic Compatibility 2014/30/EU
Never look directly into the light source. You risk injury to your retina, which may induce blindness.
Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may
concentrate the light output.
Protection optical radiation
Protection against explosion
The protection screen, lens or ultraviolet screen on the lamp can be damaged to the degree
of failure if visible damage, such as a crack or deep mark, should be replaced。
The light source in this xture shall be replaced by the manufacturer or its service agent or
similar qualication.
Always disconnect from mains before replacing the light.
3
tc 60℃ The maximun temperature that can be reached on the external surface of the fitting,
in a thermally steady state,is 60℃ 。
Avoid contact bypersons and materials.
Allow the fixture to cool for at least 5 minutes before handling.
■The light source

● Power supplies availabl:100V~240V~ 50/60Hz
● Power:410W
● LED chip:TYANSHINE 20W,White3000K-6000KLED.
● LED QTY:19PCS/(W1、W2).
● Average life:30000h
● Beam angle:Zoom function min.7°,max.55°.
●CCT:3000K~6000K
● CRI:Ra≥90
● Optical system : . High precision combination structure, high permeable glasslight rod +PMMA lens
● Zoom system:Linear electric zoom.
● Strobe:1-30 times/ second electronic strobe and random strobe.
● :Electronic dimmer,provides four dimming options.Dimmer
● Pan、Tilt:
X/Y Travel: 540°/210°
X/Y Resolution: 2.11°/0.82°
X/Y Speed: 2.5S/1.0S
●Control Mode:DMX512, RDM.
● Channel:Standard(13CH)
● Display Menu:
- The display panel adopts a 2.4-inch LCD12864 LCD screen, which is used in both Chinese and
English languages to facilitate quick operation and browse menus.
- Display board can record device’s using time , show device’s temperature, channel data and
software version .
- Customizable Settings display menu Settings, through the menu can be edited or called built-in
The program.
4
TECHNICAL INFORMATION
● Software upgrade Upload the upgrade file through the DMX interface.:
● IP20 protection:
- Protected against the entry of solid bodies larger than 12mm.
- No protection against the entry of liquids.
● Safety Devices:
- BIPOlar circuit breaker with thermal protection.
- Automatic break in power supply in case of overheating or failed operation of cooling system.
● Cooling Forced ventilation with axial fans.:
● Working mode:Silent mode;Standard mode; High Brightness mode.
● Outlooking:etal base and anti-fire plastic.M
● Light size:338X216X422
Box Size●:400X270X495MM
: 10.6kg ,: 12.6kg N.W. G.W.
●(4sets): Flycase Size
920X580X615MM
: 42.4kg ,: 78.8kg N.W. G.W.

5
Distance,spot diameter and illumination diagram
010(32'10")
2.1(6'11")
10.4(34'1")
W1
W2
W1+W2
55°Lux(fc) W1
W2
W1+W2
7°Lux(fc)
Distance m(ft in)
7°Diameter m(ft in)
55°Diameter m(ft in)
5(16'5")
1.3(4'3")
1070(99)
1000(93)
1900(177)
16700(1552)
14600(1357)
28700(2667)
13(1)
96(9)
200(19)
1600(149)
1420(132)
2750(256)
394(37)
350(33)
670(62)
6100(567)
5400(501)
9900(920)
7° 55°
3.25(10'8")
3(9'10")
0.7(2'4")
1.7(5'7")
8
6
4
2
0
2
4
6
8
217(20)
187(17)
346(32)
3230(300)
3715(345)
5443(506)
7(22'11")
1.6(5'3")
7.2(23'7")

power cord
6
ATTACHMENT AND BODY SIZE
422
338
211
321
216
296
153
303
400
244
232
216
179

Installing the projector- Fig. 3
Safety rope
The projector can be installed on the floor resting on special rubber feet, on a truss or on the ceiling or wall.
WARNING:with the exception of when the projector is positioned on the floor, the safety rope must be fitted.
This must be securely fixed to the support structure of the projector and then connected to the fixing point at
the centre of the base.
7
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
When suspending the fixture, ensure that the supporting structure and all hardware used can
hold at least 10 times the weight of all the devices they support.
Compact,standard clamp system equipped & easy installation
INSTALLATION AND CONNECTING

The L terminal is connected with the brown line.
The N terminal is connected with the blue line.
● After doing the above operation and making sure all the devices had been
installed with natural operate, press the power switch to check whether every
-thing is working normally.
L
NGround
● connection to the eiectricty mains must be carried out by a qualified electrical
installer.
● The stage lighting power supply can not be more than 2pcs pre line
8
power in out out
in in power end

9
DMX512 in
signal end
out in out in
DMX - output
1 - Shield
2 - Signal (-)
- Signal (+)
- Not connected
- Not connected
3
1
2
3
DMX-input
- Shield
- Signal (-)
- Signal (+)
- Not connected
- Not connected
4
5
4
5

Up arrowhead : page up
Down arrowhead : page down
Left arrowhead : reduce
Right arrowhead : increase
Enter : OK function
Exit : in the choice screen
DMX:
001 DMX Address Information Personal Manual control
Service Language Reversal
UP
DOWN
LEFT RIGHT
ENTER
CONTROL PANEL
10
●Color Calibration System
Because LED chip’s brightness and wave length can not be produced exactly
same by LED factory, which would cause the color difference in the LED color
fixture. To solve the issue , LIGHT SKY adopts a calibration system by calibrating
each color’s brightness curve and defining a standard color area . then apply this
standard into all the LED fixture to lower the color difference .
So, in MENU Optional of Open Calibration OFF/ON in PERSONAL is available.
Standard production , the Calibration system in ON.
But user can choose OFF as well
Lamp

MENU SETTING
11
Main
menu Ⅰ menu Ⅱ menu Ⅲ menu ⅠV menu
DMX setting >
Address > 001 - 512
Channel mode Standard(13)
State >
Blackout
Hold
Auto
Info >
Fixture times >
Power on time > 0 - 99999H
LED on time > 0 - 99999H
All time > 0 - 99999H
Fan speed > LED fan >0 - XXXXX
Power fan 0 - XXXXX
Fan
voltage > LED fan >0 - XX.XV
Power fan 0 - XX.XV
Temperatures > LED TEMP > (-40℃ - 125℃)
RDM info > 0x3888XXXXXXXX
DMX live >
1.Pan > 0 - 255
2.Pan fine > 0 - 255
3.Tilt > 0 - 255
4.Tilt fine > 0 - 255
5.P/T Speed > 0 - 255
6.Function > 0 - 255
7.Dimmer > 0 - 255
8.Dimmer fine > 0 - 255
9.Strobe > 0 - 255
10.Cold white > 0 - 255
11.Warm white > 0 - 255
12.CCT > 0 - 255
13.Zoom > 0 - 255
Version >
Display > VX.XXX
Pan/Tilt > VX.XXX
LEDDRV > VX.XXX
Person >
Pan/Tilt >
PT swap > OFF
> ON
Pan invert > OFF
> ON
Tilt invert > OFF
> ON
Led Hz >
3000Hz
6000Hz
12000Hz
24000Hz
Dimmer Curve >
Linear
Square
I-Square
SCurve
Dimmer Speed > Fade
Snap
Fan mode >
Silent mode
Standard mode
Hot mode
Display >
Language > English
Chinese
Backlight time > Always
Auto (30S)

12
Person > Display >
Intensity > 0 - 100
Rotation > Normal
Rotate
Master/Slave > Master
Slave
Manual >
Manual Control >
1.Pan > 0 - 255
2.Pan fine > 0 - 255
3.Tilt > 0 - 255
4.Tilt fine > 0 - 255
5.P/T Speed > 0 - 255
6.Function > 0 - 255
7.Dimmer > 0 - 255
8.Dimmer fine > 0 - 255
9.Strobe > 0 - 255
10.Cold white > 0 - 255
11.Warm white > 0 - 255
12.CCT > 0 - 255
13.Zoom > 0 - 255
Reset >
Pan/Tilt reset
Zoom reset
Total reset
Test →
Test all
>
test in process
Test pan/tilt test in process
Test effects test in process
Service
→ Fixture state >
Memory IC
>
OK/ Reset/ Error
Pan Encodeer OK/ Reset/ Error
Pan Drive IC OK/ Reset/ Error
Tilt Encoder OK/ Reset/ Error
Tilt Drive IC OK/ Reset/ Error
Pan OK/ Reset/ Error
Tilt OK/ Reset/ Error
Zoom OK/ Reset/ Error
>
Adjust >
Pan > 0 - 255
Tilt > 0 - 255
Zoom > 0 - 255
White Balance > Cold white > 125 - 255
> Warm white > 125 - 255
Factory >
Factory Reset Passwo
rd
YES
NO
Reset timers >
Reset power on timers Passwo
rd
YES
NO
Reset led timers Passwo
rd
YES
NO
Reset all timers Passwo
rd
YES
NO
Developer Passwo
rd
LOGO > LIGHT SKY
No LOGO
Manual OR DMX > DMX
Manual
Manual Fan Vol > OFF
ON
Power correlation > OFF
ON
LED output power Passwo
rd
50 - 100
Main menu Ⅰ menu Ⅱ menu Ⅲ menu ⅠV menu

CHANNEL FUNCTION
13
Standard(13CH)
Channel Percentage Function Note
DMX
1 0 - 255 0 - 100 Pan
2 0 - 255 0 - 100 Pan fine
3 0 - 255 Tilt
4 0 - 255 0 - 100 Tilt fine
5 0 - 255 0 - 100 P/T Speed
6
Function
0 - 10 Reserved
11 -- 20 Total reset
21 -- 30 Pan/Tilt reset
31 -- 40 Zoom reset
41 -- 50 Silent mode
51 -- 60 Standard mode
61 -- 70 Hot mode
71 -- 80 Pan invert on
81 -- 90 Tilt invert on
91 -- 100 P/T invert off
101 -- 110 PT swap on
111 -- 120 PT swap off
121 -- 130 Backlight time Always
131 -- 140 Backlight time Auto
141 -- 150 Linear
151 -- 160 Square
161 -- 170 I-Square
171 -- 180 Scurve
181 -- 190 Led Hz 3000HZ
191 -- 200 Led Hz 6000HZ
201 -- 210 Led Hz 12000HZ
211 -- 220 Led Hz 24000HZ
221 -- 230 Dimmer Speed Fade
231 -- 240 Dimmer Speed Snap
241 -- 255 Reserved
7 0 - 255 0 - 100 Dimmer
8 0 - 255 0 - 100 Dimmer fine
9
Strobe
0 - 9 Reserved
10 - 199 Strobe-effect from slow to fast
200 - 249 Random strobe-effect from slow to fast
250 - 255 Reserved
10 0 - 255 0 - 100 Cold white
11 0 - 255 0 - 100 Warm white
12 0 - 255 0 - 100 CCT
13 0 - 255 0 - 100 Zoom

CIRCUIT CONNECTING DIAGRAM
14
2510-3A
3P-NT
V1.1 09-04
+
SW
+
J9
PH-3A
J4
PH-3A
U10
YSJZ
J7
2510-8A
U3
GD32F303VET6
S5
S4
S3
S2
S1
J10
PH-5A
J8
J6
XH-3A
J5
XH-3A
J3
2510-3A
J2
VH-2A
J1
VH-2A
FAN1 FAN2 BUS DMX DMX1
B-
2
-
1
+
3
+C
+
A+
V1.04
1920-FG
PD
TEMP
D10
JR30
0R
JR31
0R
JR36
0R
JR34
0R
JR29
0R
JR28
0R
JR27 0R
JR26
0R
JR25
0R
JR24
0R
JR23
0R
JR22
0R
JR21
0R
JR20
0R
JR19
0R
JR18
0R
JR17
0R
R1
103
J7
J6
J5
J4
J3
J2
J1 D19
D18
D17
D16
D15
D14
D13
D12
D11
D9
D8
D7
D6
D5
D4
D3
D2
D1
LED board
Drive board
Display doard
Magnetic co ding Px
Magnetic co din g P y
Pan/Tilt Drive board
BUS2
PY
BUS1
PX +28V
X-SL
Y-MOTOR
V1.00
1920-XY
+28V
X-MOTOR
Y-SL
J5
J7
J3
J2
J4
J1
J9
J8
J6
U6
GD32F303CCT6
J11
J10
J1
J1
SW
Y motor cable: Y
X motor cable: X
power supply
C
+
3
1
D
J11
PH-6A
J17
U20
GD32F303CCT6
J10
J14
J2
C49
J5
HB9500-2P
J1
J9
J12
J4 J7
J6
J13
J3
J16
J15
A
1920-QD
V1.05
B
PWM
FAN
TEMP
SIG BUS2
BUS1
SW
2
ZOOM
ZOOM
Zoom motor
Zoom motor
Hall plate
Fan
power s upp ly
Positive power supply
Negative power supply
XLR board

CLEANING AND MAINTENANCES
15
■1.In order to ensure the projector could work normally. It should be kept clean always .
The lens should also be regularly cleaned to maintain an optimum light output.
Do not use any type of solvent on lens. It will damage the projector.
■2.Suggestion: The continue usage of the light don't exceed 4 hours. Or it will shorter the
usage of the lamp. Please use the alternative operation to solve this problem.
The fixture power ON time is best not over 48 hours, or it would generate lamp
protection procedure.
■3.Please disconnect the power supply when begin to maintenance take down the light.
Please let the parts cool down 10 minute at least then begin to install.
■4.Please inspect the lens or other moving parts timing and keep them clear and static.
If find anything damaged or looseness must change a lamp or fix the lamp in order to
avoid the accident.
Please check the machenical parts is jamging.After cleaning,please add some
temperature -durable juice.
■5.The light use the strong cool system.It iseasy for the dirty to be colletced.Please do
clear the hot-sak one time two week at least.
■6. After you use the light,please check the intake place whether there are some wastepaper,
please clean it up,or the windmill will break down and causing fire.
CAUTION!
Disconnect from mains before starting maintenance operation.

16
It is recommended some solution for some normal trouble shooting. Any inextricability
problems should always be handling by the professional person. Disconnect the power
supply before maintenance the light.
■ LED off / LED:
1.Please check if install the suitable voltage.
2.Please check whether the led will reach the end of their life can explode; please
replace a same description led.
3.Please check if the power supply is enough.
4.Please check whether the DMX 512 controller pass the "turn on" order.
■The light couldn't accept the control order:
1.Please check the start code address and the function option are correct.
2.Please check whether the communicate control cable is on good connection or the
cable is too long or interrupt.
3.Please check the control system is not valid, check the signal amplifier of chain
connected is valid.
4.Please check whether the communicate cable is too long or the other equipment is
mutually conjugate.
5.Please arrange the wire well, shorter the signal cable, put the high voltage cable
and low voltage cable separately.
6.Add the signal amplify isolator.
7.Signal cable is used the excellent screening doublet (Resistance 75 OHM).
8.The end of the light end and the end resistance.
■The light can't move:
1.Please check if the power supply is suitable for the light voltage data.
2.Please check the light if they are deformation, inside parts is broken, become wet
etc will lead the loose contact.
3.Please check the if the iniside lead wire and the connector is loose.
4.Please check the electric parts(such as the transformer,PCB board,contrller) is
short-circuit or burn down.
■
1.
2.
3.
4.

17
Table of contents
Other Fly Dragon Light Fixture manuals
Popular Light Fixture manuals by other brands

LOTRONIC
LOTRONIC ibiza light BEE40-LED user manual

Philips
Philips Lytecaster 1001 specification

CLF Lighting
CLF Lighting YARA manual

RUTEC
RUTEC VARDAflex Nova Double quick start guide

Federal Signal Corporation
Federal Signal Corporation BPL26L Installation and maintenance instruction

Lightolier
Lightolier Lytecaster 1134 specification