Use your thumb and middle fi nger to
hold each end. Use your pointer fi nger
to toggle the E-Switch up/down
(Fig. 1). The E-Switch volume control rocks back and
forth, always returning to the center position. EACH
SHORT PRESS (1 sec.) will raise or lower the volume
slightly. Pushing up increases the volume. (Fig. 2)
Cleaning & Changing Tubes
PAL uses a hearing aid size 312 battery.
TO TURN ON - With your fi nger, gently open the door.
Insert battery and close the door. Your Focus Ear System
is equipped with a power on delay, you will be given
several seconds to seat the device comfortably in your
ear before it turns on.
When placing the battery in your Focus Ear PAL device,
position the battery with the positive (+) fl at side up and
insert it into the battery compartment section of the battery
door. If the battery is inserted incorrectly or upside down,
the door will not close. Do not force the door to close.
Before insertion, please clean your ear and make sure the
battery door is closed properly.
CAUTION: Batteries are dangerous if swallowed! Keep
batteries out of the reach of children. Never put batteries
in your mouth for any reason they are easily swallowed.
If a battery has been swallowed, seek immediate medical
attention. For more information call the National Battery
Hotline at 202-625-3333.
Inserting Your Focus Ear PALtm
Powering On/Off Your Focus Ear PALtm
•Hold the tubing with your thumb and
index fi nger close to the ear dome and
place the instrument over the top of
your ear. (Fig. A).
•Gently insert the ear dome into your
ear canal. (Fig. B)
•Move the retention lock into position
by lifting and placing it into the bowl of
your ear. The retention lock may be
cut off with scissors if it bothers you or
is diffi cult to use. (Fig. C)
Fig. A
Fig. B
Fig. 2 Fig. 3
Fig. 1
Use a soft cloth to wipe the PAL after use to remove
any debris or moisture. The Cleaning Tool is used to re-
move debris / wax from the sound tubing and earbud.
1. To remove tubes gently rotate
the sound tubing holding the
instrument fi rmly.
3. To clean, insert the cleaning
tool through the nose cone end.
Thread all the way through the
tubing & earbud.
2. Pull sound tubing from the
instrument by pulling directly
opposite from the body of the
PAL.
4. To reassemble or change
sound tubing, simply line up
and push tubing until it snaps
into place.
Volume Adjustment (cont’d)
After inserting the battery, the PAL starts in program
one. Pushing the short button (most forward) will
change the memory. (Fig. 3) The number of beeps
correspond to the program. The programs cycle in
sequence 1,2,1,2 etc....
Find the program that is most comfortable for you and
your environment.
Programs: 1 - Speech - Normal, everyday use
2-Noise - Restaurant, meetings, etc.
3 - Optional Telephone coil
TO REMOVE - Simply grasp the tubing close to the
earbud or earmold and remove from ear canal. Lift
instrument from the top of the ear.
TO TURN OFF - To turn your Focus Ear PAL off,
simply open the battery door completely. Store in a
safe dry place without the battery inserted.
NOTE: Some irritation may occur due to becoming
accustomed to wearing a new instrument. If swelling or
redness occurs, discontinue use and visit your Doctor.
VOLUME ADJUSTMENT (Fig. 1& 2)
Pushing down lowers the volume. There are a
maximum of ten volume settings. Every time you turn
on the PAL, it will start at the last volume you had set.
Fig. C
PROGRAMS / MEMORIES (SEPARATE CONTROL)