MIC position. If the switch is in the PHANTOM position it could cause damage in the microphones.
When you use microphones that do not need phantom power supply, make sure that the switch is in the
MIC position, as the voltage in pins 2 and 3 of the XLR connector can damage the microphones.
20.- MICRO GAIN: gain control for the MICRO input.
21.- CONSOL GAIN: gain control for the remote microphone model M-203.
22.- CONSOL VOLUME: volume control for the remote microphone model M-203.
23.- CONSOL: input connector for the microphone with zone selector model M-203, R -45 connector. The
microphone model M-203 input is only sent through the PAGE OUT paging output. A maximum of 6
microphones model M-203 can be used.
INS RUC IONS FOR USE
CONNEC ION OF HE M-203 MICROPHONE
A control cable type Cat. 5 is used to connect the microphone model M-203. This cable is connected to the
CONSOL output on the MXZ-2036 mixer and to the LINE IN input on the first M-203 microphone. In the case
of needing more than one microphone, these are connected in cascade from the LINK OUT output on the first
to the LINE IN on the second and so on consecutively.
CHIMES
Chimes can be used in two ways:
-Chimes can be reproduced remotely through the microphone model M-203. Select the zone or zones where
you want to send the announcement with the ZONE 1 to 6 buttons. Then, press the TALK button that will
activate the chimes and open the microphone to give the announcement in the selected zones.
-In order to reproduce chimes from the amplifier, they must be activated on the back panel using the
PRIORITY contact closure. By closing these contacts the chimes are activated and the level of the auxiliary
input (TAPE, CD or TUNER) is weakened in the selected zones. These inputs will continue to be weakened
while the contacts are closed.
PRIORI Y IN HE INPU S
The priority function automatically weakens the input levels with less priority so that the announcement or
message transmitted by those with more priority can be clearly heard.
The input signal for microphone M-203 has maximum priority over the rest of the inputs and is activated
when the TALK button on the microphone is pressed. When priority is activated, the MICRO inputs, messages
1 or 2 and the auxiliary input (TAPE, CD or TUNER) are automatically weakened so that the message can be
heard clearly.
Message 3 is found in the next priority level, and is activated by pressing the ALARM button on the M-203
microphone for approximately two seconds. This input has priority over the MICRO inputs, messages 1 or 2
and the auxiliary input (TAPE, CD or TUNER), which will stay weakened while the message is active or the
PRIORITY contact closure is closed.
The following priority level is formed by the PRIORITY contact closure (which activates the chimes) and
messages 1 or 2. These inputs have priority over the auxiliary input (TAPE, CD or TUNER) which will stay
weakened while the message is active or the PRIORITY contact closure is closed.
MESSAGE PLAYBACK
In order to reproduce messages 1 or 2 select the message that you want to play on the back panel using
contact closure. Then press the PLAY MESSAGE button on the front panel to play it and the STOP button if
you want to stop playback.
Note: For message playback the NORMAL/ALARM selector must be in ALARM mode.
To play message 3 keep the ALARM button on the M-203 model microphone pressed down for 2 seconds.
The message is only transmitted in the selected zones if the mixer is set in NORMAL mode, or ALARM mode
is set in all zones. The message will be played continuously until the ALARM button is pressed.
- 6-