FOR-A HVS-AUX16B User manual

HVS-AUX16A
HVS-AUX16B
HVS-AUX32A
HVS-AUX64A
Auxiliary Unit
5th Edition
OPERATION
MANUAL

2
Edition Revision History
Edit.
Rev.
Date
Description
Section/Page
1
-
2014/05/19
2
-
2014/06/06
Supported HVS-390HS
3
-
2015/04/14
Supported HVS-2000
Changed model names (HVS-XT100/110 >>
HVS-100/110)
Sec. 3-3
4
-
2015/07/27
Added HVS-AUX16B.
5
-
2018/07/27
Supported HVS-490 and HVS-1200

3
Precautions
Important Safety Warnings
[Power]
Caution
Operate unit only at the specified supply voltage.
Disconnect the power cord via the power plug only. Do not pull on the cable portion.
Stop
Do not place or drop heavy or sharp-edged objects on the power cord. A damaged cord
can cause fire or electrical shock hazards. Regularly check the power cord for excessive
wear or damage to avoid possible fire / electrical hazards.
Caution
Ensure the power cord is firmly plugged into the AC outlet.
Caution
When powering on a device, supply AC power source after the supplied AC adapter has
been connected to the device. When powering off the device, first disconnect the power
cord from the AC power source.
[Operation]
Hazard
Do not operate the unit under hazardous or potentially explosive atmospheric
conditions. Doing so could result in fire, explosion, or other hazardous results.
Hazard
Do not allow liquids, metal pieces, or other foreign materials to enter the unit. Doing so
could result in fire, other hazards, or a unit malfunction.
If a foreign material does enter the unit, turn the power off and immediately disconnect
the power cord. Remove the material and contact an authorized service representative if
damage has occurred.
[Transportation]
Caution
Handle with care to avoid impact shock during transit, which may cause malfunction.
When you need to transport the unit, use the original or suitable alternative packing
material.

4
[Circuitry Access]
Do not remove covers, panels, casing, or access the circuitry with power applied to the
unit. Turn the power off and disconnect the power cord prior to removal. Internal
servicing / adjustment of unit should only be performed by qualified personnel.
Stop
Do not touch any parts / circuitry with a high heat factor.
Capacitors can retain enough electric charge to cause mild to serious shock, even after
the power has been disconnected. Capacitors associated with the power supply are
especially hazardous.
Hazard
Unit should not be operated or stored with cover, panels, and / or casing removed.
Operating the unit with circuitry exposed could result in electric shock / fire hazards or a
unit malfunction.
[Potential Hazards]
Caution
If abnormal odors or noises are noticed coming from the unit, immediately turn the
power off and disconnect the power cord to avoid potentially hazardous conditions. If
problems similar to the above occur, contact an authorized service representative
before attempting to operate the unit again.
[Rack Mount Brackets, and Rubber Feet]
Caution
To rack-mount or to install rubber feet, do not use screws or materials other than those
supplied. Doing so may cause damage to the internal circuits or components of the unit.
If you remove the rubber feet that are attached to the unit, do not reinsert the screws
that secure the rubber feet.
[Consumables]
Caution
Consumable items that are used in the unit must be periodically replaced. For further
details on which parts are consumables and when they should be replaced, refer to the
specifications at the end of the Operation Manual. Since the service life of the
consumables varies greatly depending on the environment in which they are used, such
items should be replaced at an early date. For details on replacing consumable items,
contact your dealer.

5
Upon Receipt
Unpacking
HVS-AUX16A, HVS-AUX16B, HVS-AUX32A and HVS-AUX64A units and their accessories are
fully inspected and adjusted prior to shipment. Operation can be performed immediately upon
completing all required connections and operational settings.
Check your received items against the packing lists below. Check to ensure no damage has
occurred during shipment. If damage has occurred, or items are missing, inform your supplier
immediately.
HVS-AUX16A / 32A / 64A box
ITEM
QTY
REMARKS
HVS-AUX16A
HVS-AUX32A
HVS-AUX64A
1
AC Adapter
1
AC Cord
1 set
DC power cord retaining clip
Operation Manual
1
(This manual)
HVS-AUX16B box
ITEM
QTY
REMARKS
HVS-AUX16B
1
AC Adapter
1
AC Cord
1
Operation Manual
1
(This manual)
User-supplied cable
ITEM
QTY
REMARKS
LAN cable
1
For switcher connection.
For a hub connection, use a straight-through cable.
For direct connection, use a cross-over cable.
DC Cord Clamp Installation (HVS-AUX16A/32A/64A)
Insert the DC cord into the DC IN connector, then secure the cord with the DC cord clamp attached
to the hole as shown in the figure.
DC12V IN
LAN

6
Table of Contents
1. Prior to Starting.....................................................................................................................................7
1-1. Welcome.....................................................................................................................................7
1-2. Features......................................................................................................................................7
2. Panel Descriptions................................................................................................................................8
2-1. Front Panel..................................................................................................................................8
2-2. Rear Panel ................................................................................................................................10
3. Connection .........................................................................................................................................11
3-1. Connecting HVS-100/110 .........................................................................................................11
3-2. Connecting HVS-390HS ...........................................................................................................12
3-3. Connecting HVS-2000 ..............................................................................................................13
4. Setup (Network Settings)....................................................................................................................14
4-1. SETUP Menu ............................................................................................................................14
4-2. Connecting a Single AUX Unit to a Switcher............................................................................14
4-3. Connecting Two or More AUX Units to a Switcher...................................................................15
4-3-1. Changing the AUX Unit IP Address...................................................................................15
4-3-2. Changing the AUX ID Number...........................................................................................16
4-4. LOCK (Front Panel Lock)..........................................................................................................16
5. Specifications and Dimensions ..........................................................................................................17
5-1. Unit Specifications.....................................................................................................................17
5-2. External Dimensions.................................................................................................................17
5-2-1. HVS-AUX16A.....................................................................................................................17
5-2-2. HVS-AUX16B.....................................................................................................................18
5-2-3. HVS-AUX32A.....................................................................................................................18
5-2-4. HVS-AUX64A.....................................................................................................................19

7
1. Prior to Starting
1-1. Welcome
Congratulations! By purchasing an Auxiliary Units you have entered the world of FOR-A and its
many innovative products. Thank you for your patronage and we hope you turn to FOR-A products
again and again to satisfy your video and audio needs.
FOR-A provides a wide range of products, from basic support units to complex system controllers,
which have been increasingly joined by products for computer video-based systems. Whatever
your needs, talk to your FOR-A representative. We will do our best to be of continuing service to
you.
1-2. Features
Auxiliary Units, HVS-AUX16A, HVS-AUX16B, HVS-AUX32A and HVS-AUX64A (hereafter called
AUX unit), are designed to remotely control M/E (PGM/PST) and auxiliary outputs of the Hanabi
series switchers and Multiviewers.
Supported Switchers
Switcher
Max. Connections
HVS-100/110
5 units
HVS-390HS
10 units
HVS-2000
4 units
HVS-490
12 units
HVS-1200
12 units
Supported Multiviewers
Multiviewers
Max. Connections
MV-1620HSA
2
MV-4200/4210/4220/4300/4320/4340
8
MV-1200
6
* Hereafter, “Switchers” in this document includes “Multiviewers.”
All buttons are user assignable: HVS-AUX16A and HVS-AUX16B - 16 buttons
HVS-AUX32A - 32 buttons
HVS-AUX64A - 64 buttons
AUX front panel LOCK function
Multiple AUX units connection available through an Ethernet Hub
HVS-AUX16B is a desktop type model.

8
2. Panel Descriptions
2-1. Front Panel
HVS-AUX16A
HVS-AUX16B
HVS-AUX32A
HVS-AUX64A
Letter
Name
Description
A
POWER
Displays the power status.
See the table on the next page for details on indications.
B
BUSY
Displays the flash memory writing status for backup settings.
See the table on the next page for details on indications.
B
A
E
D
C
F
H
G
POWER
BUSY SETUP
LOCK RESET
128 64 32 16 8 4 2 1
910 11 12 13 14 15 161 2 3 4 5 6 7 8
LOCK
SHIFT/TAKE
AUXILIARY UNIT HVS-AUX16A
NET MASKAUX IP SW IP AUX ID OCTET
AUXILIARY UNIT HVS-AUX64A
LOCK
TAKE
1248163264128
910 11 12 13 14 15 16
25 26 27 28 29 30 31 32
41 42 43 44 45 46 47 48
57 58 59 60 61 62 63 6449 50 51 52 53 54 55 56
33 34 35 36 37 38 39 40
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
AUX IP NET MASK SW IP AUX ID OCTET
POWER
BUSY
LOCK
SETUP
RESET
B
A
D
F
H
G
C
E
B
A
E
D
C
F
H
G
POWER
BUSY SETUP
LOCK RESET
1 2 3 4 5 6 7 8
17 18 19 20 21 22 23 24
AUX IP NET MASK SW IP AUX ID OCTET 128 64 32 16 8 4 2 1
910 11 12 13 14 15 16
25 26 27 28 29 30 31 32
AUXILIARY UNIT HVS-AUX32A
LOCK
SHIFT/TAKE
B
A
C
F
H
G
D
E
POWER
BUSY
LOCK AUX IP NET MASK SW IP AUX ID OCTET
HVS-AUX16B
AUXILIARY UNIT
1 2 3 4 5 6 7 8
LOCK
SETUP
RESET
SHIFT/TAKE 128 64 32 16 8 4 2 1
910 11 12 13 14 15 16

9
C
LOCK
Displays the LOCK status.
See the table on the next page for details on indications.
See section 4-4. "LOCK (Front Panel Lock)" for details on the lock
function.
D
SETUP
Used to set IP address or other settings.
See section 4-1 "SETUP Menu" for SETUP menu details.
E
RESET
Used to re-initialize the AUX Unit.
F
Buttons
All buttons are user assignable.
(Buttons turn green when selected.)
G
LOCK
Used to disable switcher control from the AUX Unit.
H
SHIFT/TAKE
Used as an assignable SHIFT or TAKE button on the switcher.
(Only TAKE can be assigned on HVS-AUX64A units.)
LED Color indications
LED color
LED
Green
Red
Orange
Unlit
POWER
Normal
BUSY
Normal
processing
Writing to flash
memory
Un-connected to the
switcher
LOCK
Unit locked
Unit unlocked
* All indicators, POWER, BUSY and LOCK, light orange when the SETUP menu is displayed.
IMPORTANT
Do not power OFF the unit while BUSY LED is lit orange
Changing Button Labels
Button labels can be changed for user-assignable buttons. Download and use the appropriate
label template from the FOR-A Website product page. (See the back cover.)

10
2-2. Rear Panel
HVS-AUX16A/32A/64A
HVS-AUX16B
Letter
Name
Description
A
LAN
For switcher connection
Ethernet port (100BASE-TX, RJ-45)
B
DC12V IN
12 V DC power inlet
A
B
DC12V IN
LAN
DC12V IN
LAN
LAN DC12V IN
A
B

11
3. Connection
The example systems shown below are for switchers HVS-100, HVS-390HS and HVS-2000.
Refer to each switcher operation manual for connections other than these switchers.
3-1. Connecting HVS-100/110
Multiview
(HDMI)
MU-OU connection cable
75Ω terminator
To AC power source
Preview
(AUX2)
HVS-100 rear panel
REF OUT 1 1
2 3 4 5 6 7 8 2 3 4
A
B
C
REF IN
1 2
2
AC100-240 V 50/60HzINAC100-240 V 50/60HzIN
1
TO OU LAN GENLOCK SDI INPUT
RS-422 GPI IN/T ALLY OUT
HDMI OUTAUX
To AC power source
DC12V
1 2 POW ER
OFF ON MODE SW TO MU
HVS-100OU rear panel
To AC adapter
To AC adapter
HD/SD SDI
Video server,
VTR, etc.
TSG (REF)
PGM(AUX1)
Reference
HD/SD SDI
To AC adapter
HVS-AUX16A rear panel
DC12V IN
LAN
LAN cable (straight)
PC
HUB

12
3-2. Connecting HVS-390HS
LAN cable
(straight)
PC
To AC adapter
HVS-AUX16A rear panel
DC12V IN
LAN
HUB
HD/SD SDI (M/E2 PGM)
HD/SD SDI (M/E1 PGM)
TSG (Reference)
Video Server
VTR, etc.
75Ωtermination
75Ωtermination
REF signal
RATING LABEL
CONTROL TO MU GPI/TALLY OUT
(SERVICE)
AC100-240V50/60Hz IN
POWE R 1
POWERON
OFF
POWER 2
ARCNET (BNC)
EDITOR
OPTION SLOT AC100-240V 50/60Hz IN
2RS-422
AUX HDMI GPI INSDI OUTPUT
1 2
A
B
1 2
1 2 3 4 5 6 7 8 SDI INPUT 910 11 12 13 14 1615
GPI/TALLY OUT
OPTION SLOT
C
D
1
AC100-240V 50/60Hz IN
RATING LABEL
TO OU
GENLOCK
REF IN REF O UT
LAN
1 2 3 4 5 6
3 4 5 6
Preview
(AUX1)
To AC power
source
To AC power
source
HD/SD SDI
HVS-392OU rear panel
HVS-390HS rear panel

13
3-3. Connecting HVS-2000
LAN cable
(straight)
PC
To AC power
source
HVS-AUX16A rear panel
DC12V IN
LAN
GPI IN/TALL YOUT ON
OFF RATING LABLE
AC100-24 0 V50 /60Hz IN
POWER 2POWER 1
SER. NO.
POWER
CONTROL
MODE SW
LAN1USB LAN2
HDMIVGA (MAIN)(SUB)
MONITOROUT
HD/SD SDI (M/E2 PGM)
HD/SD SDI (M/E1 PGM)
75Ωtermination
REF signal
AC 10 0 -2 4 0 V 50 /6 0H zI N
PS1
PS2
AC1 0 0 - 2 4 0 V 5 0/6 0H zI N
CPU
I/O 1
I/O 2
I/O A
I/O B
A UX
2 3 4 1 2 3 4 5 6 7 8 9 10 11 121M/E
SDIOUTPUT
3 4 521
REF OUT
6
LAN1
(MAIN)
GPIIN TALLYOUT
RS-422
ARCNET LAN2
RE FIN GENLOCK
(SU B)
1 2 3 54 6 7 8 9 10 11 12
SDIIN PUT HD MIOU T1
SDIIN PUT HD MIOU T2
13 14 15 16 17 18 19 20 21 22 23 24
IN A IN B
IN C IN D
OPTION SLOT
SER. NO.
Video server,
VTR, etc.
HD/SD SDI
Preview
image
Multiview
image
AC power
source
PC-based
GUI menu
HUB
HVS-2000
rear panel
HVS-2240OU
rear panel
AC power
source

14
4. Setup (Network Settings)
Network settings should be changed for multiple AUX units connected to a switcher, since identical IP
addresses within a network are not allowed.
4-1. SETUP Menu
The SETUP button allows you to enter Setup Menu mode, in which AUX Unit network settings can
be displayed and changed. The left four buttons are used to select information to be displayed. To
exit Setup Menu mode, press the SETUP button again.
Button name
Default setting
Description
AUX IP
192.168.0.20
Sets the AUX Unit IP address.
NETMASK
255.255.255.0
Sets the AUX Unit Netmask.
AUX IP + NETMASK
192.168.0.1
Sets the AUX Unit default Gateway.
SW IP
192.168.0.10
Specifies the IP address of the switcher to be
connected.
AUX ID
1
Sets the AUX Unit ID number.
4-2. Connecting a Single AUX Unit to a Switcher
Connection Example
No network settings are required. Connect and use your AUX Unit under the factory default
settings.
DC12V IN
LAN
HVS-AUX16A rear panel
REF OUT 1 1
2 3 4 5 6 7 8 2 3 4
A
B
C
REF IN
1 2
2
AC100-240V 50/60HzINAC100-240V 50/60HzIN
1
TO OU LAN GENLOCK SDI INPUT
RS-422 GPI IN/TALLY OUT
HDMI OUTAUX
HVS-100 rear panel
192.168.0.10
192.168.0.20
AUX ID: 1
Cross-over cable

15
4-3. Connecting Two or More AUX Units to a Switcher
Connection Example
When connecting two or more AUX Units to a switcher, each AUX Unit should have a different IP
address and AUX ID number. Refer to the following sections to change these settings.
4-3-1. Changing the AUX Unit IP Address
The following setting procedure changes the IP address of HVS-AUX16A (2) in the above
figure example, from 192.168.0.20 to 192.168.0.21.
(1) Press SETUP. All indicators turn orange and indicate that the AUX Unit is in menu
SETUP mode.
(2) Press AUX IP.
(3) To obtain the current IP address, respectively press Buttons 5 to 8 , which represent
each octet of the IP address. Each octet number will be displayed on Buttons 9 to 16
in binary mode: On or Off.
IP address
1st octet
2nd octet
3rd octet
4th octet
192.168.0.20
192
168
0
20
(4) Press and hold down 8 (the fourth octet button). The button will blink.
(5) To change the fourth octet number, use 9 to 16. In this example, the number should be
changed from 20 to 21 (16+4+1), then turn the buttons on or off as shown in the figure
below: off, off, off, on, off, on, off, on.
(6) Once the IP address is changed, LOCK will blink. Press and hold down LOCK to
confirm the change. The AUX Unit will automatically reset. (To cancel the process, press
SHIFT/TAKE without pressing LOCK.)
To return settings to default, press and hold down AUX IP.
128
64
32
16
8
4
2
1
0
0
0
1
0
1
0
0
20
0
0
0
1
0
1
0
1
21
DC12V IN
LAN
HUB
HVS-AUX16A (1) rear panel
REF OUT 1 1
2 3 4 5 6 7 8 2 3 4
A
B
C
REF IN
1 2
2
AC100-240V 50/60HzINAC100-240V 50/60HzIN
1
TO OU LAN GENLOCK SDI INPUT
RS-422 GPI IN/TALLY OUT
HDMI OUTAUX
HVS-100 rear panel
192.168.0.10
192.168.0.20
AUX ID: 1
DC12V IN
LAN
HVS-AUX16A (2) rear panel
192.168.0.21
AUX ID: 2
POWER
BUSY SETUP
LOCK RESET
128 64 32 16 8 4 2 1
910 11 12 13 14 15 161 2 3 4 5 6 7 8
LOCK
SHIFT/TAKE
AUXILIARY UNIT HVS-AUX16A
NET MASKAUX IP SW IP AUX ID OCTET
Straight-through cable

16
(7) To verify the change, press SETUP, AUX IP, and then 8 .
Check whether Buttons 9 to 16 show number “21” in binary mode.
* Use the same procedure to change NETMASK, SW IP or DEFAULT GATEWAY, as
necessary.
4-3-2. Changing the AUX ID Number
(1) Press SETUP. All indicators turn orange to indicate the AUX Unit is in SETUP menu
mode.
(2) Press AUX ID.
(3) The current AUX ID number will be displayed on Buttons 9 to 16 in binary mode: On
or Off.
(4) Press and hold down 5 . The button will blink.
(5) To change the ID number, use 9 to 16. In this example, the number should be changed
from 1to 2, then turn the buttons on or off as shown in the figure below: off, off, off, off,
off, off, on, off.
(6) Once the ID number is changed, LOCK will blink. Press and hold down LOCK to
confirm the change. The AUX unit will automatically reset. (To cancel the process, press
SHIFT/TAKE without pressing LOCK.)
To return settings to defaults, press and hold down AUX IP.
(7) To verify the change, press SETUP, then AUX ID.
Check whether Buttons 9 to 16 show number “2” in binary mode (see the figure above).
4-4. LOCK (Front Panel Lock)
The LOCK function allows you to disable AUX Unit front panel control.
To disable front panel operation:
Press and hold LOCK down for 3 or more seconds until the button blinks.
The LOCK indicator also blinks red and panel control is disabled.
To unlock the front panel:
Press and hold LOCK down for 3 or more seconds until the button turns off.
The LOCK indicator also turns off and panel control is enabled.
POWER
BUSY SETUP
LOCK RESET
128 64 32 16 8 4 2 1
910 11 12 13 14 15 161 2 3 4 5 6 7 8
LOCK
SHIFT/TAKE
AUXILIARY UNIT HVS-AUX16A
NET MASKAUX IP SW IP AUX ID OCTET

17
5. Specifications and Dimensions
5-1. Unit Specifications
AUX16A
AUX32A
AUX64A
AUX16B
Free Buttons
16
32
64
16
LOCK button
Available
Available
Available
Available
SHIFT/TAKE button
Available
Available
TAKE only
Available
Interface (LAN)
100BASE-TX RJ-45 x 1
(For switcher connection. Hub required for multiple units connection)
Temperature
0ºC to 40ºC
Humidity
30% to 85% (no condensation)
Power
+12 V DC, Pin connector x 1
Consumption
AC100-120V
8VA (3W)
10VA (4W)
15VA (7W)
12VA (4W)
AC220-240V
11VA (3W)
13VA (4W)
20VA (8W)
13VA (4W)
Dimensions
480(W) x 44(H) x 27(D)
mm
EIA1RU
480(W) x 88(H) x
27(D) mm EIA2RU
215(W) x 43(H) x
88(D) mm EIA2RU
half-rack size
Weight
1 kg
1.5 kg
0.8 kg
Consumables
AC adapter: Replace every 5 years
5-2. External Dimensions
5-2-1. HVS-AUX16A
(All dimensions in mm.)
462
480
32
44
66
6.4
429
27
DC12VIN
LAN
POWER
BUSY SETUP
LOCK RESET
128 64 32 16 8 4 2 1
910 11 12 13 14 15 161 2 3 4 5 6 7 8
LOCK
SHIFT/TAKE
AUXILIARY UNIT HVS-AUX16A
NET MASKAUX IP SW IP AUX ID OCTET

18
5-2-2. HVS-AUX16B
(All dimensions in mm.)
106810
1019510
215
88433.6
LANDC12VIN
POWER
BUSY
LOCK AUX IP NET MASK SW IP AUX ID OCTET
HVS-AUX16B
AUXILIARY UNIT
1 2 3 4 5 6 7 8
LOCK
SETUP
RESET
SHIFT/TAKE 128 64 32 16 8 4 2 1
910 11 12 13 14 15 16
5-2-3. HVS-AUX32A
(All dimensions in mm.)
462
480
429
27
6326
44
6.4
POWER
BUSY SETUP
LOCK RESET
1 2 3 4 5 6 7 8
17 18 19 20 21 22 23 24
AUX IP NET MASK SW IP AUX ID OCTET 128 64 32 16 8 4 2 1
910 11 12 13 14 15 16
25 26 27 28 29 30 31 32
AUXILIARY UNIT HVS-AUX32A
LOCK
SHIFT/TAKE
DC12VIN
LAN

19
5-2-4. HVS-AUX64A
(All dimensions in mm.)
462
480
429
‚Q‚V
6
88
76
6
6.4
DC12VIN
LAN
AUXILIARY UNIT HVS-AUX64A
LOCK
TAKE
1248163264128
910 11 12 13 14 15 16
25 26 27 28 29 30 31 32
41 42 43 44 45 46 47 48
57 58 59 60 61 62 63 6449 50 51 52 53 54 55 56
33 34 35 36 37 38 39 40
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
AUX IP NET MASK SW IP AUX ID OCTET
POWER
BUSY
LOCK
SETUP
RESET

This manual suits for next models
3
Table of contents
Other FOR-A Control Unit manuals
Popular Control Unit manuals by other brands

National Instruments
National Instruments NI-9206 Getting started

BIFFI
BIFFI ICON3000 Series Installation, operation and maintenance manual

MD
MD mXion SLIM user manual

GEMAR Lumitec
GEMAR Lumitec IRIDIUM 113886 user manual

artisan
artisan PB1651ADC1 user guide

Viessmann
Viessmann VITOTRONIC 100 Technical data manual

Quectel
Quectel MC60-TE-A user guide

Yoshitake
Yoshitake TA-22ML product manual

Beckhoff
Beckhoff KL2502 Documentation

Bosch
Bosch MAP Control Center IUI-MAP0001-2 user manual

Marshall Excelsior
Marshall Excelsior Excelerator ME993-16 Installation and operation

Viessmann
Viessmann VITOTRONIC300 Installation and service instructions