Forch 5380P 2 User manual

5380P 2 / 5380P 1
GER
CZE
DUT
DAN
POR
ENG
FRE
POL
SPA
SLO
HRV
SLV
SWE
HUN
Stickstoff / Formiergas Lecksuchpaket Klima
Pakety pro detekci netěsností klimatizace pomocí dusíku
/ formovacího plynu
Lækagesøgepakke Klima
Stikstof- / formeergas-lekzoek-set airco
AC Leakage Detection Kit for Nitrogen / Forming Gas
Set détecteur de fuites pour climatisation à l’azote et au Formiergas
Nitrogén / formálógáz szivárgáskereső csomagok klímaberendezéshez
Zestaw do wykrywania nieszczelności klimatyzacji
Pacotes detectores de fugas em equipamento de climatização –
Nitrogénio/ Gás protector
Kisik / Plinski paket za traženje propusta Klima
Pakety pre detekciu netesností klimatizácie pomocou dusíka
/ formovacieho plynu
Paket iskanja netesnosti klim - Dušik/formiran plin
Paquetes detectores de fugas en equipos de climatización –
Nitrógeno / Gas protector
Flyktiga media/Gas Läckagesökningspaket för Klimatanläggningar

Lecksuchpakete Klima
GER
1. Generelle Sicherheitshinweise
1.1 Lesen und verstehen Sie immer alle Hinweise über die Sicherheit und Bedienung, bevor Sie
anfangen mit diesen Geräten zu arbeiten.
1.2 Jegliche Unachtsamkeit kann zu einem Schaden an Mensch und Material führen und kann
tödliche Folgen haben.
1.3 Diese Geräte dürfen nur von technisch ausgebildeten Personen bedient werden, die die
entsprechende Berechtigung vorweisen können.
1.4 Informieren Sie sich über die Bedingungen im Umgang mit Kältemitteln und deren Ölen.
Beachten Sie die Sicherheitsdatenblätter. Diese erhalten Sie von Ihrem Kältemittel-Lieferanten.
1.5 Beachten Sie den vorgeschriebenen Umgang mit Druckgasflaschen, sowie die Sicherheits-
datenblätter der verwendeten technischen Gase. Diese erhalten Sie von Ihrem Gaslieferanten.
1.6 Tragen Sie immer eine entsprechende Sicherheitsbrille und die vorgeschriebene Schutzklei-
dung, wenn Sie mit Kältemitteln und deren Ölen arbeiten.
1.7 Achten Sie auf ausreichende Belüftung der Räume in denen mit Kältemitteln und deren Ölen
gearbeitet wird.
1.8 Niemals den erlaubten Arbeitsdruck in der Klimaanlage überschreiten.
1.9 Befüllen Sie die Klimaanlage nur mit Stickstoff oder Formiergas, wenn diese leer (drucklos)
ist. Gegebenenfalls Kältemittel vorab evakuieren und Anlage vakuumieren.
Wasserstoff ist brennbar ! Verwenden Sie deshalb bei der Formiergas Lecksuche ausschließlich
das angegebene Formiergas in der Konzentration 95/5 !! In dieser Konzentration besteht keine
Brandgefahr und ist vollkommen ausreichend für die Leckagesuche.
2. Stickstoff Lecksuchpaket
Artikelübersicht
Stickstoff Lecksuch Paket Klima 5380 P2
1. 5380 690 Servicekupplung ND Blau
2. 5380 606 Klimaschlauch blau 3m
3. 5380 714 Adapter ¼“ x ¼“ SAE
4. 5400 45 Druckminderer Stickstoff 20 bar
5. 5380 155 Flaschenwagen für 10l Gasflaschen
! Wichtig !
Die Klimaanlage muss vor der Befüllung mit Stickstoff vollkommen leer (drucklos) sein.
Um Druckwechselleckagen erkennen zu können, muss die Anlage zuvor einer Vakuumhalte-
prüfung unterzogen werden.
Eventuelle Magnetventile sollten Sie vor der Befüllung mit Stickstoff manuell öffnen, indem Sie
diese mit der Bordspannung versorgen. So stellen Sie sicher, dass auch in diese Bereiche der
Klimaanlage Stickstoff gelangt.
• Tauschen Sie den Standard-Adapter des Stickstoffmanometers gegen den mitgelieferten
Adapter ¼“ x ¼“SAE aus. Verwenden Sie ein geeignetes Dichtband (z.B. Teflon) oder ein
flüssiges Gasdichtmittel.
• Schließen Sie den Druckminderer an der Stickstoffflasche an. Achten Sie darauf, dass der
weiße Dichtring aufgelegt ist. Achten Sie auf festen Sitz der Befestigungsmutter.
• Vergewissern Sie sich vor der Erstinbetriebnahme, dass der nach unten zeigende Drehgriff
vollständig nach links (gegen den Uhrzeiger) gedreht und Öffnungsventil 1 geschlossen (im
Uhrzeigersinn ganz nach rechts gedreht) ist. Somit ist der Ausgangsdruck (rechtes
Manometer) drucklos.
• Schließen Sie den mitgelieferten blauen Kältemittelschlauch an den zuvor von Ihnen
montierten Adapter an und verbinden das andere Ende des Schlauches fest mit der
mitgelieferten ND-Schnellkupplung.
• Öffnen Sie nun das Flaschenventil.
• Das linke Manometer zeigt nach Öffnen des Flaschenventils den Flaschendruck an.
• Stellen Sie nun den Ausgangsdruck langsam mit dem nach unten zeigenden Drehgriff
(Druckregler)auf den entsprechenden Arbeitsdruck ein (Im Uhrzeigersinn = Druck erhöhen).
Öffnungsventil 1
Flaschenanschluss
Druckregler
←
←
←

Öffnungsventil 1
Flaschenanschluss
Druckregler
←
←
←
• Führen Sie nun eine Dichtheitsprüfung des Lecksuchpaketes durch, indem Sie das
Öffnungsventil 1 langsam öffnen und auf entweichendes Gas achten (evtl. Leckfinderspray
verwenden).
• Ist das Lecksuchpaket dicht, adaptieren Sie die Schnellkupplung mit der leeren Klimaanlage.
Öffnen Sie das Drehventil der Schnellkupplung. Die Anlage wird nun mit dem am Manometer
eingestellten Druck mit Stickstoff befüllt.
• Ist die Anlage befüllt, das Flaschenventil schließen und den Druckverlust beobachten,
(min. 30 min.) Zischgeräusche lokalisieren und Leitungen mit Leckfinderspray (Blasenbildung)
einsprühen, um eine undichte Stelle zu finden.
• Nach erfolgter Leckagesuche kann das Gas vorsichtig !!! über den zweiten Serviceanschluß
(zweite Servicekupplung) oder durch vorsichtiges !! Lösen (Nicht abschrauben !) des
Schlauchanschlußes in die Atmosphäre gelassen werden.
• VORSICHT! Anlage steht unter hohem Druck ! Während des Ablassens des Stickstoffes über
den Schlauch diesen während des Ablassvorganges gut festhalten. Ein sich lösender
Schlauch schlägt peitschenartig um sich und kann erhebliche Verletzungen herbeiführen.
• Vor der Befüllung mit Kältemittel die Klimaanlage nochmals evakuieren und vakuumieren um
evtl. Stickstoffreste zu entfernen.
3. Formiergas Lecksuchpaket
Artikelübersicht
Formiergas Lecksuch Paket 5380 P1
1. 5380 690 Servicekupplung ND Blau
2. 5380 606 Klimaschlauch blau 3m
3. 5380 155 Flaschenwagen für 10l Gasflaschen
4. 5380 161 Formiergas Lecksuchgerät
5. 5380 162 Formiergas Druckminderer 20 bar
! Wichtig !
Die Klimaanlage muss vor der Befüllung mit Formiergas vollkommen leer (drucklos) sein.
Eventuelle Magnetventile sollten Sie manuell öffnen, indem Sie diese mit der Bordspannung
versorgen. So stellen Sie sicher, dass auch in diesen Bereichen der Klimaanlage Formiergas
gelangt.
• Die grundlegende Vorgehensweise ist die selbe, wie bei der Stickstofflecksuche.
• Der mitgelieferte Adapter ist nur aufgesetzt Schrauben Sie den Adapter fest auf den
entsprechenden Anschluß am Manometer. Verwenden Sie unbedingt ein geeignetes
Dichtband (z.B. Teflon) oder ein flüssiges Gasdichtmittel.
• Schließen Sie den Druckminderer an der Formiergasflasche (Linksgewinde) an. Achten Sie
darauf, dass der weiße Dichtring aufgelegt ist. Achten Sie auf festen Sitz der
Befestigungsmutter.
• Vergewissern Sie sich vor der Erstinbetriebnahme, dass der nach unten zeigende Drehgriff
vollständig nach links (gegen den Uhrzeiger) gedreht und Öffnungsventil 1 geschlossen (im
Uhrzeigersinn ganz nach rechts gedreht) ist. Somit ist der Ausgangsdruck (rechtes
Manometer) drucklos.
• Schließen Sie den mitgelieferten blauen Kältemittelschlauch an den Adapter unterhalb des
rechten Manometers an und verbinden das andere Ende des Schlauches fest mit der
mitgelieferten ND-Schnellkupplung.
• Öffnen Sie nun das Flaschenventil.
• Das linke Manometer zeigt nach dem Öffnen des Flaschenventils den Flaschendruck an.
• Stellen Sie nun den Ausgangsdruck langsam mit dem nach unten zeigenden Drehgriff
(Druckregler) auf den entsprechenden Arbeitsdruck ein (Im Uhrzeigersinn = Druck erhöhen).
• Führen Sie nun eine Dichtheitsprüfung des Lecksuchpaketes durch, indem Sie das
Öffnungsventil 1 langsam öffnen und auf entweichendes Gas achten (Lecksuchgerät
verwenden).
• Ist das Lecksuchpaket dicht, adaptieren Sie die Schnellkupplung mit der leeren Klimaanlage.
Öffnen Sie das Drehventil der Schnellkupplung. Die Anlage wird nun mit dem am Manometer
eingestellten Druck mit Formiergas befüllt.

• Ist die Anlage befüllt, das Flaschenventil schließen und den Druckverlust beobachten,
(min. 30 min.) und Leitungen mit dem elektronischen Lecksuchgerät von oben absuchen, um
eine undichte Stelle zu finden.
-siehe auch Bedienungsanleitung des Lecksuchgerätes !!! -
• Nach erfolgter Leckagesuche kann das Gas vorsichtig !!! über den zweiten Serviceanschluß
(zweite Servicekupplung) oder durch vorsichtiges !! Lösen (Nicht abschrauben !) des
Schlauchanschlußes in die Atmosphäre gelassen werden.
• VORSICHT! Anlage steht unter hohem Druck ! Während des Ablassens des Formiergases
über den Schlauch diesen während des Ablassvorganges gut festhalten. Ein sich lösender
Schlauch schlägt peitschenartig um sich und kann erhebliche Verletzungen herbeiführen.
• Vor der Befüllung mit Kältemittel die Klimaanlage nochmals evakuieren und vakuumieren um
evtl. Formiergasreste zu entfernen.
Pakety pro detekci netěsností klimatizace
CZE
1. Všeobecné bezpečnostní pokyny
1.1 Přečtěte si vždy všechny pokyny k bezpečnosti a obsluze a ujistěte se, že jim rozumíte, dříve
než začnete s těmito přístroji pracovat.
1.2 Jakákoliv nepozornost může vést k zraněním osob a škodám na materiálu a mít smrtelné
následky.
1.3 Tyto přístroje smějí obsluhovat pouze technicky vyškolené osoby, které se mohou prokázat
příslušným oprávněním.
1.4 Informujte se o podmínkách manipulace s chladivy a jejich oleji. Dodržujte pokyny uvedené
v bezpečnostních listech. Tyto listy obdržíte od svého dodavatele chladiv.
1.5 Dodržujte předepsanou manipulaci s lahvemi se stlačeným plynem a pokyny uvedené
v bezpečnostních listech používaných technických plynů. Tyto listy obdržíte od svého
dodavatele plynů.
1.6 Noste vždy, když pracujete s chladivy a jejich oleji, odpovídající bezpečnostní brýle
a předepsaný ochranný oděv.
1.7 Dbejte na dostatečné větrání prostor, ve kterých pracujete s chladivy a jejich oleji.
1.8 Nikdy nepřekračujte pracovní tlak povolený v klimatizaci.
1.9 Naplňujte klimatizaci dusíkem nebo formovacím plynem pouze tehdy, když je prázdná
(bez tlaku). Popřípadě chladivo předem odčerpejte a zařízení vakuujte.
Vodík je hořlavý! Používejte proto při detekci pomocí formovacího plynu výlučně uvedený
formovací plyn v koncentraci 95/5!! Při této koncentraci nehrozí nebezpečí vzniku požáru a je
pro detekci úniku zcela dostatečná.
2. Paket pro detekci netěsností pomocí dusíku
Přehled obsahu
Paket pro detekci netěsností klimatizace
pomocí dusíku 5380 P2
1. 5380 690 servisní spojka NT, modrá
2. 5380 606 hadice klimatizace, modrá, 3 m
3. 5380 714 adaptér 1/4" x 1/4" SAE
4. 5400 45 redukční ventil pro láhev s dusíkem 20 bar
5. 5380 155 vozík na lahve s plynem 10 l
! Důležité !
Klimatizace se před naplněním dusíkem musí úplně vyprázdnit (nesmí být pod tlakem).
Aby bylo možné detekovat úniky při změně tlaku, musí se zařízení předtím podrobit zkoušce
udržení vakua.
Případné magnetické ventily byste měli před naplněním dusíkem manuálně otevřít tím, že je
napájíte palubním napětím. Tak zajistíte, že se dusík dostane i do těchto oblastí klimatizace.
• Vyměňte standardní adaptér manometru dusíku za dodaný adaptér 1/4" x 1/4" SAE. Použijte
vhodnou těsnicí pásku (např. Teflon) nebo tekutý těsnicí prostředek na plyny.
• Připojte redukční ventil k láhvi s dusíkem. Nezapomeňte na bílý těsnicí kroužek. Dbejte na
pevné usazení upevňovací matice.
Otvírací ventil 1
Přípojka pro láhev
Regulátor tlaku
←
←
←

• Ujistěte se před prvním uvedením do provozu, že otočná rukojeť ukazující dolů je otočena
úplně doleva (proti směru hodinových ručiček) a že otvírací ventil 1 je zavřený (otočený ve
směru hodinových ručiček úplně doprava). Tak je výstupní tlak (pravý manometr) nulový.
• Připojte dodanou modrou hadici klimatizace k adaptéru, který jste již namontovali předtím,
a spojte pevně druhý konec hadice s dodanou rychlospojkou NT.
• Nyní otevřete ventil lahve.
• Levý manometr ukazuje po otevření ventilu lahve tlak v lahvi.
• Nastavte nyní výstupní tlak pomalu pomocí otočné rukojeti ukazující směrem dolů (regulátor
tlaku) na odpovídající pracovní tlak (ve směru hodinových ručiček = zvyšování tlaku).
• Proveďte nyní zkoušku těsnosti detekčního paketu tím, že otevřete pomalu otvírací ventil
1 a dáváte pozor na unikající plyn (příp. použijte sprej pro hledání netěsností).
• Jestliže je detekční paket těsný, adaptujte rychlospojku s prázdnou klimatizací. Otevřete
otočný ventil rychlospojky. Zařízení se nyní plní dusíkem na tlak nastavený na manometru.
• Když je zařízení naplněné, zavřete ventil lahve a pozorujte ztrátu tlaku (min. 30 min.).
Lokalizujte syčení a postříkejte vedení sprejem pro hledání netěsností (tvorba bublinek),
abyste mohli najít netěsné místo.
• Po provedené detekci netěsností je možné plyn opatrně!!! vypustit do atmosféry přes druhou
servisní přípojku (druhou servisní spojku) nebo opatrným!!! povolením (nikoliv odšroubováním!)
hadicové přípojky.
• POZOR! Zařízení je pod vysokým tlakem! Během vypouštění dusíku přes hadici je nutné ji po
celou dobu pevně držet. Uvolněná hadice sebou prudce hází a může přivodit vážné úrazy.
• Před naplněním klimatizace chladivem ji ještě jednou vakuujte, abyste z ní odstranili příp.
zbytky dusíku.
3. Paket pro detekci netěsností pomocí formovacího plynu
Přehled obsahu
Paket pro detekci netěsností klimatizace pomocí
formovacího plynu 5380 P1
1. 5380 690 servisní spojka NT, modrá
2. 5380 606 hadice klimatizace, modrá, 3 m
3. 5380 155 vozík na lahve s plynem 10 l
4. 5380 161 detektor úniku formovacího plynu
5. 5380 162 redukční ventil pro láhev s formovacím plynem 20 bar
! Důležité !
Klimatizace se před naplněním formovacím plynem musí úplně vyprázdnit (nesmí být pod
tlakem).
Případné magnetické ventily byste měli manuálně otevřít tím, že je napájíte palubním napětím.
Tak zajistíte, že se formovací plyn dostane i do těchto oblastí klimatizace.
• Základní postup je stejný jako u detekce netěsností pomocí dusíku.
• Dodaný adaptér je pouze nasazený. Našroubujte adaptér pevně na příslušnou přípojku na
manometru. Použijte bezpodmínečně vhodnou těsnicí pásku (např. Teflon) nebo tekutý těsnicí
prostředek na plyny.
• Připojte redukční ventil k láhvi s formovacím plynem (levý závit). Nezapomeňte na bílý těsnicí
kroužek. Dbejte na pevné usazení upevňovací matice.
• Ujistěte se před prvním uvedením do provozu, že otočná rukojeť ukazující dolů je otočena
úplně doleva (proti směru hodinových ručiček) a že otvírací ventil 1 je zavřený (otočený ve
směru hodinových ručiček úplně doprava). Tak je výstupní tlak (pravý manometr) nulový.
• Připojte dodanou modrou hadici klimatizace k adaptéru pod pravým manometrem a spojte
pevně druhý konec hadice s dodanou rychlospojkou NT.
• Nyní otevřete ventil lahve.
• Levý manometr ukazuje po otevření ventilu lahve tlak v lahvi.
• Nastavte nyní výstupní tlak pomalu pomocí otočné rukojeti ukazující směrem dolů (regulátor
tlaku) na odpovídající pracovní tlak (ve směru hodinových ručiček = zvyšování tlaku).
• Proveďte nyní zkoušku těsnosti detekčního paketu tím, že otevřete pomalu otvírací ventil
1 a dáváte pozor na unikající plyn (použijte detektor úniku formovacího plynu).
Otvírací ventil 1
Přípojka pro láhev
Regulátor tlaku
←
←
←

• Jestliže je detekční paket těsný, adaptujte rychlospojku s prázdnou klimatizací. Otevřete
otočný ventil rychlospojky. Zařízení se nyní plní formovacím plynem na tlak nastavený na
manometru.
• Když je zařízení naplněné, zavřete ventil lahve a pozorujte ztrátu tlaku (min. 30 min.).
Prohledejte vedení zeshora pomocí elektronického detektoru, abyste našli netěsné místo.
- viz také návod k obsluze detektoru úniku formovacího plynu!!! -
• Po provedené detekci netěsností je možné plyn opatrně!!! vypustit do atmosféry přes druhou
servisní přípojku (druhou servisní spojku) nebo opatrným!!! povolením (nikoliv odšroubováním!)
hadicové přípojky.
•POZOR! Zařízení je pod vysokým tlakem! Během vypouštění formovacího plynu přes hadici je
nutné ji po celou dobu pevně držet. Uvolněná hadice sebou prudce hází a může přivodit vážné
úrazy.
• Před naplněním klimatizace chladivem ji ještě jednou vakuujte, abyste z ní odstranili příp.
zbytky formovacího plynu.
Lækagesøgepakke Klima
DAN
1. Generelle sikkerhedshenvisninger
1.1 Læs og forstå altid alle henvisninger vedr. sikkerhed og brugsanvisning, inden du begynder
at arbejde med apparatet.
1.2 Enhver uagtsomhed kan føre til skade på mennesker eller materiel og kan have dødelige
følger.
1.3 Disse apparater må kun betjenes af teknisk uddannede personer, som kan forevise
passende berettigelse.
1.4 Vær informeret om betingelser for omgang med kølemidler og deres olie. Tag hensyn til
sikkerhedsdatablade. Disse får du fra din kølemiddelleverandør.
1.5 Overhold den foreskrevne omgang med trykgasflasker, samt sikkerhedsdatablade på de
anvendte tekniske gasser. Disse modtager du fra din gasleverandør.
1.6 Bær altid en tilsvarende sikkerhedsbriller og beskyttelsesbeklædning der er foreskrevet, når
du arbejder med kølemiddel og deres olie.
1.7 Sørg for tilstrækkelig udluftning af de rum, hvor der arbejdes med kølemiddel og deres olie.
1.8 Overskrid aldrig det tilladte arbejdstryk i klimaanlæg
1.9 Fyld kun klimaanlægget med kvælstof eller formiergas, når disse er tomme (trykfri). I givet
fald evakueres kølemidlet først og anlægget vakuummers. Hydrogen er brændbart! Anvend
derfor ved formiergas lækagesøgning udelukkende det angivne formiergas i koncentrationen
95/5!!. I denne koncentration består ingen brandfare og er fuldkommen tilstrækkelig for
lækagesøgningen.
2. Kvælstof lækagesøgepakke
Artikeloversigt
Kvælstof lækagesøge pakke Klima 5380 P2
1. 5380 690 Servicekobling LT blå
2. 5380 606 Klimaslange blå 3m
3. 5380 714 Adapter ¼” x ¼” SAE
4. 5400 45 Reduktion kvælstof 20 bar
5. 5380 155 Flaskevogn til 10l gasflasker
! Vigtig !
Klimaanlæg skal, inden påfyldning med kvælstof, være fuldstændig tom (trykfri)
For at kunne se trykskiftlækager, skal anlægget først have en vakuumholdekontrol.
Eventuelle magnetventiler skal du åbne manuel, inden du fylder kvælstof på, idet du forsyner
denne med kantspænding. Sådan sikre du, at der også kommer kvælstof i dette område
af klimaanlægget.
• Udskift standard-adapteren på kvælstofmanometeret med den medleverede adapter ¼” x ¼”
SAE. Anvend et egnet tætningsbånd (f.eks. Teflon) eller et flydende gastætningsmiddel.
• Luk reduktionen på kvælstofflasken. Vær opmærksom på, at den hvide ring er lagt på. Vær
opmærksom på, at fastgørelsesmøtrikken sidder fast.
Openingsventiel 1
Flesaansluiting
Drukregelaar
←
←
←

• Vær forvisset om, inden ibrugtagning første gang, at det håndtag der peger nedad, er drejet
helt mod venstre (mod uret) og åbningsventil 1 er lukket (drejet med uret helt mod højre).
Dermed er udgangstrykket trykløs (højre manometer)
• Tilslut den blå medleverede kølemiddelslange på den adapter du tidligere har monteret og
forbind den anden ende af slangen med den medleverede LT-lynkobling.
• Åben nu flaskeventilen
• Det venstre manometer viser efter åbning af flaskeventilen flasketrykket.
• Sæt nu langsomt udgangstrykket, med det håndtag der peger nedad (trykregulator), på det
passende arbejdstryk (med uret = tryk forhøjes).
• Gennemfør nu en tæthedskontrol af lækagesøgepakken, idet du langsom åbner
åbningsventilen 1 og passer på gasudslip (anvend evt. lækagesøgespray).
• Er lækagesøgepakken tæt, sætter du lynkoblingen sammen med det tomme klimaanlæg.
Åben drejeventilen på lynkoblingen. Anlægget bliver nu fyldt med kvælstof, med det tryk der
er indstillet på manometeret.
• Er anlægget fyldt, lukkes flaskeventilen og vær opmærksom på tryktab, (min. 30 min.) lokaliser
hvislelyde og sprøjt ledninger med lækagesøgerspray (blæredannelse), for at finde utætte ste
der.
• Efter udført lækagesøgning kan gassen forsigtig!!!, gennem den anden servicetilslutning
(anden servicekobling) eller ved forsigtig!! at løsne (ikke skrues af!) slangetilslutningen,
slippes ud i atmosfæren.
• FORSIGTIG! Anlægget står under højt tryk! under udslip af kvælstof gennem slangen holdes
denne under udløbsprocessen godt fast. En slange der løsner sig slår piskeragtig om sig og
kan bevirke betydelige kvæstelser.
• Inden fyldning med kølemiddel skal klimaanlægget evakueres og vakkumeres igen, for at
fjerne eventuelle rester af kvælstof.
3. Formiergas lækagesøgepakke
Artikeloversigt
Formiergas lækagesøge pakke 5380 P1
1. 5380 609 Servicekobling LT blå
2. 5380 606 Klimaslange blå 3m
3. 5380 155 Flaskevogn til 10l gasflasker
4. 5380 161 Formiergas lækagesøgeapparat
5. 5380 162 Formiergas trykregulator 20 bar
!Vigtig!
Klimaanlæg skal, inden påfyldning med formiergas, være fuldstændig tom (trykfri)
Eventuelle magnetventiler skal du åbne manuel, idet du forsyner denne med kantspænding.
Sådan sikre du, at der også kommer formiergas i dette område af klimaanlægget.
• Den grundlæggende fremgangsmåde er den samme som ved kvælstoflækagesøgning.
• Den medleverede adapter er kun påsat, skru adapteren fast på den passende tilslutning på
manometeret. Anvend ubetinget et egnet tætningsbånd (f.eks. Teflon) eller et flydende
gastætningsmiddel.
• Luk reduktionen på formiergasflasken (linksgevind). Vær opmærksom på, at den hvide ring
er lagt på. Vær opmærksom på, at fastgørelsesmøtrikken sidder fast.
• Vær forvisset om, inden ibrugtagning første gang, at det håndtag der peger nedad, er drejet
helt mod venstre (mod uret) og åbningsventil 1 er lukket (drejet med uret helt mod højre).
Dermed er udgangstrykket trykløs (højre manometer)
• Tilslut den blå medleverede kølemiddelslange på den adapter du tidligere har monteret og
forbind den anden ende af slangen med den medleverede LT-lynkobling.
• Åben nu flaskeventilen.
• Det venstre manometer viser, efter åbning af flaskeventilen, flasketrykket.
• Sæt nu langsom udgangstrykket med det håndtag der peger nedad (trykregulator) på det
passende arbejdstryk (med uret = tryk forhøjes).
• Gennemfør nu en tæthedskontrol af lækagesøgepakken, idet du langsom åbner
åbningsventilen 1 og passer på gasudslip (anvend evt. lækagesøgespray).
Openingsventiel 1
Flesaansluiting
Drukregelaar
←
←
←

• Er lækagesøgepakken tæt, sætter du lynkoblingen sammen med det tomme klimaanlæg.
Åben drejeventilen på lynkoblingen. Anlægget bliver nu fyldt med formiergas, med det tryk der
er indstillet på manometeret.
• Er anlægget fyldt, lukkes flaskeventilen og vær opmærksom på tryktab, (min. 30 min.) og
afsøg ledninger med det elektroniske lækagesøgeapparat, for at finde utætte steder. – se også
brugsanvisningen for lækagesøgeapparatet !!!
• Efter udført lækagesøgning kan gassen forsigtig!!!, gennem den anden servicetilslutning
(anden servicekobling) eller ved forsigtig!! at løsne (ikke skues af!) slangetilslutningen, slippes
ud i atmosfæren.
• FORSIGTIG! Anlægget står under højt tryk! under udslip af formiergas gennem slangen
holdes denne under udløbsprocessen godt fast. En slange der løsner sig slår piskeragtig om
sig og kan bevirke betydelige kvæstelser.
• Inden fyldning med kølemiddel skal klimaanlægget evakueres og vakkumeres igen, for at
fjerne eventuelle rester af formiergas.
Lekzoek-set airco
DUT
1. Algemene veiligheidsaanwijzingen
1.1 Lees steeds alle aanwijzingen over veiligheid en gebruik en zorg ervoor dat u deze heeft
begrepen, voordat u deze toestellen begint te gebruiken.
1.2 Iedere onoplettendheid kan tot schade aan mens en materiaal leiden en dodelijke gevolgen
hebben.
1.3 Deze toestellen mogen uitsluitend door technisch opgeleide personen worden bediend die
de desbetreffende bevoegdheid kunnen aantonen.
1.4 Informeer naar de voorwaarden met betrekking tot de omgang met koelapparaten en de
bijbehorende oliën. Houd rekening met de veiligheidsinformatiebladen. Deze ontvangt u van uw
koelapparaat-leverancier.
1.5 Houd rekening met de voorgeschreven omgang met cilinders met samengeperste gassen
alsook met de veiligheidsinformatiebladen van de gebruikte technische gassen. Deze ontvangt
u van uw gasleverancier.
1.6 Draag steeds een geschikte veiligheidsbril en de voorgeschreven beschermende kleding
wanneer u met koelapparaten en de bijbehorende oliën werkt.
1.7 Let op voldoende ventilatie van de ruimtes waar met koelapparaten en de bijbehorende oliën
wordt gewerkt.
1.8 Nooit de toegestane werkdruk in de airco overschrijden.
1.9 Vul de airco alleen met stikstof of formeergas, als deze leeg (vrij van druk) is. Eventueel
koelapparaat vooraf leeg maken en airco vacuumeren.
Waterstof is brandbaar! Gebruik daarom bij het zoeken van formeergas-lekkages uitsluitend het
vermelde formeergas in de concentratie 95/5!! In deze concentratie bestaat geen brandgevaar
en is volledig toereikend voor het opsporen van lekkages.
2. Stikstof-lekzoek-set
Artikeloverzicht
Stikstof-lekzoek-set airco 5380 P2
1. 5380 690 Servicekoppeling ND blauw
2. 5380 606 Aircoslang blauw 3m
3. 5380 714 Adapter ¼“ x ¼“ SAE
4. 5400 45 Drukregelaar stikstof 20 bar
5. 5380 155 Fleskar voor 10 L gasflessen
! Belangrijk!
De airco moet vóór het vullen met stikstof volledig leeg (vrij van druk) zijn.
Om drukwissellekkages te kunnen herkennen, moet de airco vooraf een vacuumbehoudtest
ondergaan.
Eventuele magneetventielen moet u voor het vullen met stikstof manueel openen door deze met
boordspanning te verzorgen. Zo weet u zeker dat stikstof ook in deze regio’s van de airco
terechtkomt.
Openingsventiel 1
Flesaansluiting
Drukregelaar
←
←
←

Openingsventiel 1
Flesaansluiting
Drukregelaar
←
←
←
• Vervang de standaard-adapter van de stikstofmanometer met de meegeleverde adapter
¼“ x ¼“SAE. Gebruik een geschikt afdichtband (bv. teflon) of een vloeibaar gasafdichtmiddel.
• Sluit de drukregelaar aan de stikstoffles aan. Let op dat de witte pakking erop is gelegd. Let
op dat de bevestigingsmoer vast zit.
• Vergewis u voor de eerste ingebruikname ervan dat de naar beneden wijzende draaigreep
volledig naar links (tegen de wijzer van de klok) is gedraaid en openingsventiel 1 gesloten is
(met de wijzer van de klok mee helemaal naar rechts gedraaid). Zodoende is de uitgangsdruk
vrij van druk (rechter manometer).
• Sluit de meegeleverde blauwe koudemiddelslang op de vooraf door u gemonteerde
adapter aan en verbind het andere uiteinde van de slang goed met de meegeleverde
ND-snelkoppeling.
• Open nu de afsluiter van de fles.
• De linker manometer toont na het openen van de afsluiter de flesdruk.
• Stel nu langzaam de uitgangsdruk met de naar beneden wijzende draaigreep (drukregelaar)
op de gewenste werkdruk in (met de wijzer van de klok = druk verhogen).
• Voer nu een controle van de lekzoek-set op dichtheid door. Daarvoor opent u langzaam het
openingsventiel 1 en let op ontsnappend gas (evtl. lekzoeker-spray gebruiken).
• Als de lekzoek-set dicht is, verbindt u de snelkoppeling met de lege airco. Open het
draaiventiel van de snelkoppeling. De airco wordt nu tot door middel van de manometer
ingestelde druk met stikstof gevuld.
• Als de airco gevuld is, de afsluiter van de fles sluiten en op het drukverlies letten, (minimaal
30 minuten) sisgeluiden lokaliseren en leidingen met lekzoeker-spray insproeien
(blaasvorming) om een ondichte plek te vinden.
• Na voltooiing van het opsporen van lekkages kan het gas voorzichtig(!!!) over de tweede
serviceaansluiting (tweede servicekoppeling) of door voorzichtig(!!!) losdraaien van de
slangaansluiting (niet afschroeven!) in de omgeving worden vrijgelaten.
• LET OP! Airco staat onder hoge druk! Tijdens het aflaten van het stikstof via de slang deze
daarbij goed vasthouden. Een slang die los raakt, slaat als een zweep om zich heen en kan
tot aanzienlijk letsel leiden.
• Voor het vullen met koudemiddel de airco nogmaals leeg maken en vacuumeren om eventuele
stikstofresten te verwijderen.
3. Formeergas-lekzoek-set
Artikeloverzicht
Formeergas-lekzoek-set 5380 P1
1. 5380 690 Servicekoppeling ND blauw
2. 5380 606 Aircoslang blauw 3m
3. 5380 155 Fleskar voor 10 L gasflessen
4. 5380 161 Formeergas-lekzoeker
5. 5380 162 Formeergas-drukregelaar 20 bar
! Belangrijk!
De airco moet vóór het vullen met formeergas volledig leeg (vrij van druk) zijn.
Eventuele magneetventielen moet u handmatig openen door deze van boordspanning te
voorzien. Zo weet u zeker dat formeergas ook in deze regio’s van de airco terechtkomt.
• De fundamentele aanpak is dezelfde als bij het zoeken van een stikstoflekkage.
• De meegeleverde adapter is slechts opgezet. Schroef de adapter vast op de juiste aansluiting
aan de manometer. Gebruik in ieder geval geschikt afdichtband (bv. teflon) of vloeibaar
gasafdichtmiddel.
• Sluit de drukregelaar aan de formeergasfles aan (linkse schroefdraad). Let op dat de witte
pakking erop is gelegd. Let op dat de bevestigingsmoer vast zit.
• Vergewis u er voor de eerste ingebruikname van dat de naar beneden wijzende draaigreep
volledig naar links (tegen de wijzer van de klok) is gedraaid en openingsventiel 1 gesloten is
(met de wijzer van de klok mee helemaal naar rechts gedraaid). Zodoende is de uitgangsdruk
vrij van druk (rechter manometer).

• Sluit de meegeleverde blauwe koudemiddelslang aan de adapter onder de rechtse
manometer aan en verbind het andere uiteinde van de slang goed met de meegeleverde
ND-snelkoppeling.
• Open nu de afsluiter van de fles.
• De linke manometer toont na het openen van de afsluiter de flesdruk.
• Stel nu langzaam de uitgangsdruk in met de naar beneden wijzende draaigreep
(drukregelaar) op de gewenste werkdruk (met de wijzer van de klok = druk verhogen).
• Voer nu een controle van de lekzoek-set op dichtheid door. Daarvoor opent u langzaam het
openingsventiel 1 en let op ontspannend gas (lekzoeker gebruiken).
• Als de lekzoek-set dicht is, verbindt u de snelkoppeling met de lege airco. Open het
draaiventiel van de snelkoppeling. De airco wordt nu met de aan de hand van de manometer
ingestelde druk met formeergas gevuld.
• Als de airco gevuld is, de afsluiter van de fles sluiten en op het drukverlies letten (minimaal
30 minuten) en leidingen met de elektronische lekzoeker van bovenaf controleren om een
ondichte plek te vinden.
-zie ook handleiding van de lekzoeker!!! -
• Na voltooiing van het opsporen van lekkages kan het gas voorzichtig(!!!) over de tweede
serviceaansluiting (tweede servicekoppeling) of door voorzichtig(!!!) losdraaien van de
slangaansluiting (niet afschroeven!) in de omgeving worden vrijgelaten.
•LET OP! Airco staat onder hoge druk! Tijdens het vrijlaten van het formeergas via de slang
deze daarbij goed vasthouden. Een slang die los raakt, slaat als een zweep om zich heen en
kan tot aanzienlijk letsel leiden.
• Voor het vullen met koudemiddel de airco nogmaals ledig maken en vacuumeren om
eventuele formeergasresten te verwijderen.
AC Leakage Detection Kit
ENG
1. General safety instructions
1.1 Always read and understand all instructions regarding safety and operation before you start
working with these devices.
1.2 Any carelessness might cause damages to persons or material and might have fatal
consequences.
1.3 These devices must only be operated by technically trained persons having the
corresponding authorization.
1.4 Be informed about the conditions in handling refrigerants and the corresponding oils.
Observe the safety data sheets. Your supplier for refrigerants will submit them to you.
1.5 Follow the prescribed handling of compressed-gas cylinders as well as the safety data
sheets of the used technical gases. Your gas supplier will submit them to you.
1.6 Always wear appropriate safety goggles and the prescribed protective clothing when
working with refrigerants and the corresponding oils.
1.7 Provide for sufficient aeration of the rooms where you are working with refrigerants and the
corresponding oils.
1.8 Never exceed the admitted working pressure in the air conditioning system.
1.9 Fill the air conditioning system only with nitrogen or forming gas if it is empty
(depressurized). If required, first evacuate the refrigerant and vacuum the system.
Hydrogen is inflammable! Therefore, only use the indicated forming gas with a concentration of
95/5 when detecting leakages using forming gas !! At this concentration there is no fire hazard
and it is absolutely sufficient to perform leakage detection.
2. Kit for leakage detection
for nitrogen Item overview
Nitrogen leakage detection kit AC 5380 P2
1. 5380 690 service coupling LP blue
2. 5380 606 AC hose blue 3m
3. 5380 714 adaptor ¼“ x ¼“ SAE
4. 5400 45 pressure reducer nitrogen 20 bars
5. 5380 155 bottle trolley 10l gas bottles
Opening valve
Bottle connection
Pressure regulator
←
←
←

• Then perform a leak test of the kit of leakage detection by slowly opening the opening valve
1 and paying attention to escaping gas (if required, use leakage detection spray).
• If the leakage detection kit is tight, adapt the quick action coupling to the empty air
conditioning system. Open the turning valve of the quick action coupling. Then the system is
filled with nitrogen to the pressure which is preset on the manometer.
• If the system is filled, close the bottle valve and observe the pressure loss, (for at least 30
min.) Localize hissing noises and spray leakage detection spray onto the hoses, in order
to detect leakages (formation of bubbles).
• After performing the leakage detection carefully !!! drain the gas into the atmosphere via the
second service connection (second service coupling) or by carefully !! detaching (not
unscrewing!) the hose connection.
• CAUTION! System is under high pressure! When draining the nitrogen via the hose firmly
hold the hose during the draining process. If the hose is released it strikes out whip-like and
might cause considerable injuries.
• Before filling the air conditioning system with refrigerant again evacuate and vacuum the
system in order to remove possible nitrogen remainders.
3. Leakage detection kit of forming gas
Item overview
Kit of leakage detection of forming gas 5380 P1
1. 5380 690 service coupling ND blue
2. 5380 606 AC hose blue 3m
3. 5380 155 bottle trolley for 10l gas bottles
4. 5380 161 leakage detector for forming gas
5. 5380 162 pressure reducer for forming gas 20
bars
! Important !
The air conditioning system must be completely empty (depressurized) before filling it with
forming gas.
Manually open possibly existing solenoid valves, by supplying them via the on-board voltage.
This way, it is possible to make sure that the forming gas also attains these areas of the air
conditioning system
• The basic procedure is the same as for the nitrogen leakage detection.
• The adaptor included in the delivery is only applied. Screw the adaptor tight on the
corresponding connections on the manometer. Imperatively use an appropriate sealing tape
(e.g. Teflon) or a liquid gas sealant.
• Connect the pressure reducer to the forming gas bottle (left-hand thread). Make sure that the
white washer is applied and that the fastening nut is firmly seated.
• Make sure that the twist grip showing downward is turned completely to the left
(anticlockwise) before the first commissioning and that the opening valve 1 is closed
(completely turned clockwise to the right). This way the outlet pressure (manometer on the
right) is depressurized.
• Connect the blue refrigerant hose included in the delivery to the adaptor mounted below the
manometer on the right and connect the other end of the hose to the LP quick-action coupling
included in the delivery
• Then open the bottle valve.
• After opening the bottle valve the left manometer indicates the pressure of the bottle.
• Then slowly adjust the outlet pressure by turning the twist grip (pressure regulator) showing
downward (pressure regulator) to the corresponding working pressure (clockwise = increasing
pressure).
• Then perform a leak test of the kit of leakage detection by slowly opening the opening valve
1 and paying attention to escaping gas (use leakage detection spray).
• If the leakage detection kit is tight, adapt the quick action coupling to the empty air
conditioning system.
Open the turning valve of the quick action coupling. Then the system is filled with nitrogen to
the pressure which is preset on the manometer.
Opening valve 1
Bottle connection
Pressure regulator
←
←
←

• If the system is filled, close the bottle valve and observe the pressure loss, (for at least
30 min.) and search for a leakage on the hoses using an electronic leakage detector from top
to bottom.
- also refer to the operating instructions of the leakage detection device!!! -
• After performing the leakage detection carefully !!! drain the gas into the atmosphere via the
second service connection (second service coupling) or by carefully !! detaching (not
unscrewing!) the hose connection.
•CAUTION! System is under high pressure! When draining the nitrogen via the hose firmly hold
the hose during the draining process. If the hose is released it strikes out whip-like and might
cause considerable injuries.
• Before filling the air conditioning system with refrigerant again evacuate and vacuum the
system in order to remove possible nitrogen remainders.
Set détecteur de fuite climatisation
FRE
1. Consignes de sécurité générales
1.1 Veuillez lire et suivre les consignes relatives à la sécurité et à l’utilisation de ce set avant de
vous en servir.
1.2 Toute inadvertance risque de provoquer des dégâts matériels et personnels ou même la
mort.
1.3 Ces appareils ne peuvent être utilisés que par des personnes ayant eu une formation
technique et qui peuvent présenter une attestation adéquate.
1.4 Informez-vous sur la manière dont il faut manipuler les fluides frigorigènes et leurs huiles.
Tenez compte du contenu des fiches techniques de sécurité que vous pourrez obtenir par votre
fournisseur de fluide frigorigène.
1.5 Tenez compte des règles pour la manipulation des bouteilles de gaz sous pression ainsi que
des fiches techniques de sécurité relatives aux gaz techniques utilisés que vous pourrez obtenir
par votre fournisseur de gaz.
1.6 Portez toujours des lunettes de sécurité appropriées et des vêtements de protection adaptés
à la manipulation de fluides frigorigènes et leurs huiles.
1.7 Veillez à bien ventiler les locaux dans lesquels sont manipulés les fluides frigorigènes et
leurs huiles.
1.8 Ne dépassez jamais la pression de service admissible dans l’installation de climatisation.
1.9 N’introduisez l’azote ou le Formiergas (mélange d’azote et d’hydrogène) que lorsque
l’installation de climatisation est décompressée. Au besoin, vidangez le fluide réfrigérant
préalablement à l’introduction du gaz et mettez l’installation sous vide.
L’hydrogène pur étant hautement inflammable, le mélange azote-hydrogène du Formiergas
utilisé pour votre recherche de fuites doit être de l’ordre 95/5 !! Ce mélange est ininflammable
et complètement suffisant pour la recherche de fuites.
2. Set détecteur de fuite
Codes articles
Set détecteur de fuite pour climatisation à
l’azote 5380 P2
1. 5380 690 raccord de service ND bleu
2. 5380 606 tuyau climatisation bleu 3m
3. 5380 714 adaptateur ¼“ x ¼“ SAE
4. 5400 45 détendeur azote 20 bars
5. 5380 155 chariot pour bouteilles de gaz 10l
! Important !
Avant d’introduire l’azote, l’installation de climatisation doit être complètement décompressée
pour permettre une recherche de fuite par détection d’un changement de pression, l’installation
de climatisation doit être soumise à un contrôle de maintien sous vide.
Avant d’introduire l’azote, il est conseillé d’ouvrir manuellement les électrovannes éventuelles en
les alimentant avec la tension de bord. Cette manière de procéder assure que l’azote arrive
également dans ces zones.
soupape
d’ouverture
raccord bouteille
régulateur de
pression
←
←
←

• Remplacez l’adaptateur standard du manomètre d’azote par l’adaptateur ¼“ x ¼“SAE fourni.
Utilisez absolument un ruban d’étanchéité adéquat (par ex. téflon) ou un liquide imperméable
aux gaz.
• Fermez le manodétenteur sur la bouteille d’azote. Veillez à mettre en place la bague
d’étanchéité blanche et à immobiliser l’écrou de fixation.
• Avant la première mise en marche, la poignée dirigée vers le bas doit être complètement
tournée à gauche (sens antihoraire) et la vanne d’ouverture 1 doit être fermée (sens horaire).
De cette manière, la sortie (manomètre à droite) n’est plus sous pression.
• Branchez le tuyau bleu du fluide frigorigène fourni sur l’adaptateur que vous venez de monter
et connectez l’extrémité du flexible au raccord rapide BP fourni.
• Ouvrez maintenant la vanne de bouteille.
• Après ouverture de la vanne de bouteille, le manomètre indique la pression dans la bouteille.
• Réglez la pression de sortie lentement à l’aide de la poignée dirigée vers le bas (régulateur
de pression) pour obtenir la pression de travail nécessaire (sens horaire = augmentation de la
pression).
• Effectuez un contrôle d’étanchéité de l’ensemble de détection de fuite en ouvrant lentement la
vanne d’ouverture 1 et veillez à détecter toute fuite de gaz éventuelle (utilisez éventuellement
du spray de détection de fuite).
• Si le set de détection de fuite est parfaitement étanche, branchez le raccord rapide sur la
climatisation vidangée.
Ouvrez la vanne rotative du raccord rapide. L’installation va être remplie d’azote à la pression
réglée au manomètre.
• Lorsque l’installation est remplie, fermer la vanne de bouteille et observez la perte de pression
pendant au moins 30 min. Localisez les bruits de sifflement et vaporisez du spray de détection
de fuite dans les conduites pour détecter une éventuelle fuite (formation de bulles).
• Après avoir effectué la recherche de fuites, évacuez avec précaution (!!!) le gaz dans
l’atmosphère par l’intermédiaire du 2ème raccord de service ou en desserrant avec
précaution (!!!) le raccord du tuyau (sans le dévisser).
• ATTENTION ! L’installation est sous pression élevée. En évacuant l’azote, maintenez le tuyau
bien en place. Un tuyau qui se détache risque de frapper comme un fouet et de causer des
blessures graves.
• Avant le remplissage avec du fluide frigorigène, recommencez l’évacuation et la mise à vide
de l’installation de climatisation pour éliminer les résidus d’azote éventuels.
3. Set détecteur de fuite
Codes articles
Set détecteur de fuite pour climatisation
au Formiergas 5380 P1
1. 5380 690 raccord de service BP bleu
2. 5380 606 tuyau climatisation bleu 3m
3. 5380 155 chariot pour bouteilles de gaz 10l
4. 5380 161 détecteur de fuite au Formiergas
5. 5380 162 manodétenteur Formiergas 20 bars
! Important !
Avant d’introduire le Formiergas, l’installation de climatisation doit être complètement
décompressée
Ouvrez manuellement les électrovannes éventuelles en les alimentant avec la tension de bord.
Assurez-vous que le Formiergas arrive également dans ces zones.
• La procédure est similaire à celle pour la détection de fuite à l’azote.
• L’adaptateur fourni est seulement posé et doit être vissé fermement sur le raccord du
manomètre. Utilisez absolument un ruban d’étanchéité adéquat (par ex. téflon) ou un liquide
imperméable aux gaz.
• Fermez le mano-détendeur sur la bouteille de Formiergas (filetage à gauche). Veillez à mettre
en place la bague d’étanchéité blanche et à immobiliser l’écrou de fixation.
• Avant la première mise en marche, la poignée dirigée vers le bas doit être complètement
tournée à gauche (sens antihoraire) et la vanne d’ouverture 1 doit être fermée (sens horaire).
soupape
d’ouverture
raccord bouteille
régulateur
de pression
←
←
←

De cette manière, la sortie (manomètre à droite) n’est plus sous pression.
• Branchez le tuyau bleu du fluide frigorigène fourni sur l’adaptateur au-dessous du manomètre
à droite et connectez fermement l’autre extrémité du tuyau au raccord rapide BP fourni.
• Ouvrez maintenant la vanne de la bouteille.
• Après ouverture de la vanne de la bouteille, le manomètre indique la pression dans la
bouteille.
• Avant la première mise en marche, la poignée dirigée vers le bas doit être complètement
tournée à gauche (sens antihoraire) et la vanne d’ouverture 1 doit être fermée (sens horaire).
De cette manière, la sortie (manomètre à droite) n’est plus sous pression.
• Branchez le tuyau bleu du fluide frigorigène fourni sur l’adaptateur au-dessous du manomètre
à droite et connectez fermement l’autre extrémité du tuyau au raccord rapide BP fourni.
• Ouvrez maintenant la vanne de la bouteille.
• Après ouverture de la vanne de la bouteille, le manomètre indique la pression dans la
bouteille.
• Réglez maintenant la pression de sortie lentement à l’aide de la poignée dirigée vers le bas
(régulateur de pression) pour obtenir la pression de travail nécessaire (sens horaire =
augmentation de la pression).
• Effectuez un contrôle d’étanchéité du set de détection de fuite en ouvrant lentement la vanne
d’ouverture 1 et veillez à détecter toute fuite de gaz éventuelle (utilisez éventuellement du
spray de détection de fuite).
• Si l’ensemble de détection de fuite est parfaitement étanche, branchez le raccord rapide sur
la climatisation vidangée.
Ouvrez la vanne rotative du raccord rapide. L’installation va être remplie de Formiergas à la
pression réglée au manomètre.
• Lorsque l’installation est remplie, fermer la vanne de la bouteille et observez la perte de
pression pendant au moins 30 min. Faites une recherche de fuite à l’aide du détecteur de
fuite pour détecter une éventuelle fuite (référez-vous également à la notice d’utilisation du
détecteur de fuite !).
• Après avoir effectué la recherche de fuites, évacuez avec précaution (!!!) le gaz dans
l’atmosphère par l’intermédiaire du 2ème raccord de service ou en desserrant avec
précaution (!!!) le raccord du tuyau (sans le dévisser !).
• ATTENTION ! L’installation est sous pression élevée. En évacuant le Formiergas, maintenez
le tuyau bien en place. Un tuyau qui se détache risque de frapper comme un fouet et de
causer des blessures graves.
• Avant le remplissage avec du fluide frigorigène, recommencez la vidange et la mise à vide de
l’installation de climatisation pour éliminer les résidus de Formiergas éventuels.
Szivárgáskereső csomagok klímaberendezéshez
HUN
1. Általános biztonsági tudnivalók
1.1. Mielőtt e készülékekkel dolgozni kezd, mindig olvassa át és értse meg valamennyi
biztonságra és kezelésre vonatkozó figyelmeztetést.
1.2. Bármely figyelmetlenség emberi sérüléshez és anyagi kárhoz vezethet, halálos
következményekkel járhat.
1.3. Ezeket a készülékeket csak műszakilag képzett dolgozók kezelhetik, akik megfelelő
jogosultságot tudnak felmutatni.
1.4. Tájékozódjon a hűtőanyagok és azok olajai kezelésének feltételeiről. Tartsa be a biztonsági
adatlapokban leírtakat. Ezeket Ön hűtőanyag-beszállítójától kapja.
1.5. Tartsa be a nyomás alatti gázt tartalmazó palackok előírt kezelését, valamint az alkalmazott
technológiai gázok biztonsági adatlapjait. Ezeket Ön gázbeszállítójától kapja.
1.6. Ha hűtőanyagokkal és azok olajaival dolgozik, mindig viseljen megfelelő biztonsági
szemüveget, és az előírt védőruházatot.
1.7. Ügyeljen azon helyiségek megfelelő szellőzésére, amelyekben hűtőanyagokkal és azok
olajaival dolgoznak.
1.8. A klímaberendezésben sosem szabad túllépni a megengedett munkanyomást.

1.9. Ha a klímaberendezés üres (nyomásmentes), csak nitrogénnel vagy formálógázzal töltse fel.
Adott esetben előbb a hűtőanyagokat kiüríteni, és a berendezésben vákuumot létrehozni.
A hidrogén gyúlékony! Ezért formálógázas szivárgáskeresésnél kizárólag a megadott, 95/5
koncentrációjú formálógázt használja!! Ebben a koncentrációban nem áll fenn tűzveszély, és ez
tökéletesen elegendő a szivárgáskereséshez.
2. Nitrogénes szivárgáskereső csomag
A cikk áttekintése
Nitrogénes klímaszivárgás-kereső csomag 5380 P2
1. 5380 690 szerviz-csőkapcsoló, alacsony nyomású, kék
2. 5380 606 klímatömlő, kék, 3m
3. 5380 714 adapter Ľ” x Ľ” SAE
4. 5400 45 nyomáscsökkentő, nitrogén, 20 bar
5. 5380 155 palackkocsi 10 l gázpalackhoz
! Fontos !
A klímaberendezésnek a nitrogénnel való feltöltés előtt teljesen üresnek (nyomásmentesnek) kell
lennie. A nyomásváltásból eredő szivárgások felismerése érdekében a berendezésen előbb
vákuumtartási vizsgálatot kell végezni. Az esetleges mágnesszelepeket a nitrogénnel feltöltés
előtt kézzel nyissa ki oly módon, hogy fedélzeti feszültséggel látja el. Így biztosítja, hogy
a klímaberendezésnek ezen zónáiba is jusson nitrogén.
• Cserélje ki a nitrogén-manométer alapadapterét a csomaggal szállított Ľ” x Ľ” SAE adapterre.
Megfelelő tömítőszalagot (pl. teflont) vagy folyékony, gázálló tömítőanyagot használjon.
• Csatlakoztassa a nyomáscsökkentőt a nitrogénes palackra. Vigyázzon arra, hogy a fehér
tömítőgyűrű fel legyen téve. Vigyázzon a rögzítőanya jó illesztésére.
• Az első üzembe helyezés előtt győződjön meg arról, hogy a lefelé mutató forgókar teljesen
balra (az óramutató járásával ellenkező irányban) van elforgatva, az 1. nyitószelep pedig zárva
(az óramutató járásának megfelelő irányban, egészen jobbra forgatva) áll. Így a kimenet (jobb
oldali manométer) nyomás nélküli.
• Kösse a csomaggal szállított kék hűtőanyag-tömlőt az előtte Ön által felszerelt adapterre,
a tömlő másik végét pedig jól rögzítve kösse össze a csomaggal szállított kisnyomású gyors
csőcsatlakozóval.
• Most nyissa ki a palackszelepet.
• A palackszelep kinyitása után a bal oldali manométer a palacknyomást mutatja.
• Most a kimeneti nyomást a lefelé mutató forgókarral (nyomásszabályozóval) lassan állítsa be
a megfelelő munkanyomásra (az óramutatóval megegyező irányban = nyomás növelése).
• Ekkor végezze el a szivárgáskereső csomag tömítettség vizsgálatát oly módon, hogy lassan
kinyitja az 1. nyitószelepet, és vigyáz a kiáramló gázra (esetleg szivárgáskereső sprayt
használ).
• Ha a szivárgáskereső csomag tömített, illessze össze a gyorscsatlakozót az üres
klímaberendezéssel. Nyissa meg a gyorscsatlakozó forgószelepét. Ekkor a berendezés
a manométeren beállított nyomáson feltöltődik nitrogénnel.
• Ha a berendezés feltöltődött, a palackszelepet el kell zárni, és meg kell figyelni
a nyomáscsökkenést (min. 30 percig), meg kell határozni a sistergő zajok helyét, a tömítetlen
hely megtalálása érdekében a vezetékeket be kell fújni szivárgáskereső spray-vel
(buborékképződés).
• Az elvégzett szivárgáskeresés után a gáz óvatosan !!! a második szervizcsatlakozón (második
szerviz-csőkapcsolón) keresztül, vagy a tömlőcsatlakozó óvatos !! meglazításával (nem
lecsavarni !) a légkörbe engedhető.
• VIGYÁZAT! A berendezés nagy nyomás alatt áll! Amikor a tömlőn keresztül leeresztik
a nitrogént, azt a leeresztési művelet alatt jól kell rögzíteni. A kilazuló tömlő korbácsszerűen
csapkod maga körül, és jelentékeny sérüléseket okozhat.
• Hűtőanyaggal való feltöltése előtt a klímaberendezést még egyszer ki kell üríteni és
nyomásmentesíteni kell, hogy eltávolítsák az esetleges nitrogénmaradványokat.
1. nyitószelep
palackcsatlakozó
nyomásszabályzó
←
←
←

3. Formálógázas szivárgáskereső csomag
A cikk áttekintése
Formálógázas szivárgáskereső csomag 5380 P1
1. 5380 690 szerviz-csőkapcsoló, alacsony nyomású, kék
2. 5380 606 klímatömlő, kék, 3m
3. 5380 155 palackkocsi 10 l gázpalackhoz
4. 5380 161 formálógázas szivárgáskereső műszer
5. 5380 162 nyomáscsökkentő, formálógáz, 20 bar
! Fontos !
A klímaberendezésnek a formálógázzal való feltöltés előtt teljesen üresnek (nyomásmentesnek)
kell lennie.
Az esetleges mágnesszelepeket kézzel nyissa ki oly módon, hogy fedélzeti feszültséggel látja el.
Így biztosítja, hogy a klímaberendezésnek ebbe a zónáiba is jusson formálógáz.
• Az alapvető eljárás ugyanaz, mint a nitrogénes szivárgáskeresésnél.
• A csomaggal szállított adaptert csak feltették. Jól csavarozza rá az adaptert a manométeren
levő megfelelő csatlakozásra. Feltétlenül megfelelő tömítőszalagot (pl. teflont) vagy folyékony,
gázálló tömítőanyagot használjon.
• Csatlakoztassa a nyomáscsökkentőt a formálógázas (balmenetes) palackra. Vigyázzon arra,
hogy a fehér tömítőgyűrű fel legyen téve. Vigyázzon a rögzítőanya jó illesztésére.
• Az első üzembe helyezés előtt győződjön meg arról, hogy a lefelé mutató forgókar teljesen
balra (az óramutató járásával ellenkező irányban) van elforgatva, az 1. nyitószelep pedig zárva
(az óramutató járásának megfelelő irányban, jobbra forgatva) áll. Így a kimenet (jobb oldali
manométer) nyomás nélküli.
• Kösse a csomaggal szállított kék hűtőanyag-tömlőt a jobb oldali manométer alatti adapterre,
a tömlő másik végét pedig jól rögzítve kösse össze a csomaggal szállított kisnyomású gyors
csőcsatlakozóval.
• Most nyissa ki a palackszelepet.
• A palackszelep kinyitása után a bal oldali manométer a palacknyomást mutatja.
• Most a kimeneti nyomást a lefelé mutató forgókarral (nyomásszabályozóval) lassan állítsa be
a megfelelő munkanyomásra (az óramutatóval megegyező irányban = nyomás növelése).
• Ekkor végezze el a szivárgáskereső csomag tömítettség vizsgálatát oly módon, hogy lassan
kinyitja az 1. nyitószelepet, és vigyáz a kiáramló gázra (szivárgáskereső műszert használ).
• Ha a szivárgáskereső csomag tömített, illessze össze a gyorscsatlakozót az üres
klímaberendezéssel. Nyissa meg a gyorscsatlakozó forgószelepét. Ekkor a berendezés
a manométeren beállított nyomáson feltöltődik formálógázzal.
• Ha a berendezés feltöltődött, a palackszelepet el kell zárni és meg kell figyelni
a nyomáscsökkenést (min. 30 percig), a tömítetlen hely megtalálása érdekében a vezetékeket
fentről át kell vizsgálni az elektronikus szivárgáskereső műszerrel.
- Lásd a szivárgáskereső műszer kezelési utasítását is !!! -
• Az elvégzett szivárgáskeresés után a gáz óvatosan !!! a második szervizcsatlakozón (második
szerviz-csőkapcsolón) keresztül, vagy a tömlőcsatlakozó óvatos !! meglazításával (nem
lecsavarni !) a légkörbe engedhető.
• VIGYÁZAT! A berendezés nagy nyomás alatt áll! Amikor a tömlőn keresztül leeresztik
a formálógázt, azt a leeresztési művelet alatt jól kell rögzíteni. A kilazuló tömlő korbácsszerűen
csapkod maga körül, és jelentékeny sérüléseket okozhat.
• Hűtőanyaggal való feltöltése előtt a klímaberendezést még egyszer ki kell üríteni, és
nyomásmentesíteni kell, hogy eltávolítsák az esetleges formálógáz-maradványokat.
1. nyitószelep
palackcsatlakozó
nyomásszabályzó
←
←
←

Zestaw do wykrywania nieszczelności klimatyzacji
POL
1.Ogólne wskazówki dotyczące bezpieczeństwa
1.1 Proszę uważnie przeczytać i dokładnie zapoznać się wszystkimi wskazówkami dotyczącymi
bezpieczeństwa użytkowania oraz obsługi przed podjęciem pracy z powyższym urządzeniem.
1.2 Wszelka nieostrożność może spowodować szkody ludzkie i materialne, a nawet doprowadzić
do śmierci.
1.3 Urządzenie to może być obsługiwane wyłącznie przez osoby z odpowiednimi kwalifikacjami
technicznymi, mogące przedstawić odpowiednie upoważnienie.
1.4 Proszę zasięgnąć informacji odnośnie warunków postępowania z chłodziwami i ich olejami.
Proszę przestrzegać zaleceń kart charakterystyk dotyczących tych substancji. Karty otrzymacie
Państwo od swojego dostawcy chłodziw.
1.5 Proszę przestrzegać zaleceń odnośnie obchodzenia się z ciśnieniowymi butlami z gazem
oraz zaleceń z kart charakterystyk będących w użyciu gazów technicznych. Karty te otrzymacie
Państwo od swojego dostawcy gazu.
1.6 Proszę nosić zawsze okulary ochronne i zalecaną odzież ochronną, podczas pracy
z chłodziwami lub ich olejami.
1.7 Proszę uważać na to, aby pomieszczenia, w których pracuje się z chłodziwami lub ich
olejami miały podczas tej pracy odpowiednią wentylację.
1.8 Nigdy nie przekraczać dopuszczalnego ciśnienia pracy urządzenia klimatyzacyjnego.
1.9 Proszę napełniać urządzenie klimatyzacyjne azotem lub gazem formującym tylko, jeżeli
urządzenie jest puste (pozbawione ciśnienia). W razie potrzeby urządzenie opróżnić
z chłodziwa i wytworzyć w nim próżnię.
Wodór jest palny! dlatego też, proszę używać podczas poszukiwania nieszczelności przy
pomocy gazu formującego, podanego gazu formującego w koncentracji 95/5!! Przy tej
koncentracji nie istnieje niebezpieczeństwo zapłonu, a jest ona wystarczająca do poszukiwania
nieszczelności.
2. Zestaw do poszukiwania nieszczelności na bazie azotu
Przegląd produktu
Zestaw do poszukiwania nieszczelności na
bazie azotu 5380 P2
1. 5380 680 złączka serwisowa ND niebieska
2. 5380 606 szlauch klimatyzacyjny niebieski 3 m
3. 5380 714 adapter Ľ x Ľ SAE
4. 5400 45 reduktor ciśnienia azotu 20 bar
5. 5380 155 wózek do butli gazowych 10 l
! WAŻNE !
Przed napełnieniem azotem urządzenie klimatyzacyjne musi być całkowicie puste (bez
ciśnienia). Aby móc rozpoznać nieszczelności wynikające ze zmian ciśnienia należy urządzenie
poddać testowi na utrzymanie próżni.
Ewentualne zawory magnetyczne powinny zostać manualnie otwarte przed napełnieniem
urządzenia azotem, w ten sposób, iż pozostają pod napięciem pokładowym. W ten sposób
zostanie zapewnione, że także do tych obszarów urządzenia klimatyzacyjnego dostanie się azot.
• Proszę wymienić standardowe adaptery manometru azotu na adaptery Ľ x Ľ SAE. Proszę
użyć odpowiedniej taśmy uszczelniającej (np. teflonu) lub płynnego środka uszczelniającego
do gazów.
• Proszę podłączyć reduktor ciśnienia do butli z dwutlenkiem węgla. Proszę pamiętać o tym by
była nałożona biała uszczelka. Należy uważać by nakrętka mocująca była odpowiednio
przykręcona.
• Proszę upewnić się przed pierwszym uruchomieniem, że skierowany na dół kurek jest
przekręcony całkowicie w lewo ( w kierunku przeciwnym do kierunku ruchu wskazówek
zegara) oraz że zawór otwierający 1 jest zamknięty ( zgodnie z ruchem wskazówek zegara
przekręcony w prawo). Tym samym ciśnienie wyjściowe (prawy manometr) jest zerowe.
• Następnie proszę przyłączyć dostarczony niebieski szlauch do chłodziwa, do zamontowanego
wcześniej adaptera, a drugi koniec szlaucha przymocować do szybkozłączki ND
Zawór
otwierający 1
Podłączenie butli
Regulator ciśnienia
←
←
←

• Teraz należy otworzyć zawór butli
• Lewy manometr wskazuje po odkręceniu zaworu butli ciśnienie butli.
• Teraz należy przy pomocy skierowanego na dół kurka(regulator ciśnienia) powoli przestawić
ciśnienie z ciśnienia początkowego na odpowiednie ciśnienie robocze (kierunek zgodny
z kierunkiem ruchu wskazówek zegara = zwiększanie ciśnienia).
• Należy sprawdzić szczelność zestawu do poszukiwania nieszczelności. W tym celu należy
powoli otwierać zawór otwierający 1 i uważać na uciekający gaz (ewentualnie użyć spray do
szukania nieszczelności).
• Jeżeli zestaw do poszukiwania nieszczelności jest szczelny, można go podłączyć do pustego
urządzenia klimatyzacyjnego. Proszę otworzyć zawór obrotowy szybkozłączki. Butla zostanie
w tym momencie napełniona azotem o ciśnieniu, które zostało ustawione na manometrze.
• W momencie, gdy urządzenie zostanie napełnione gazem, należy zakręcić zawór butli
i obserwować spadek ciśnienia ( minimum 30 min). Ażeby znaleźć ewentualne nieszczelności
należy lokalizować miejsca, z których dochodzi syczenie i spryskiwać przewody sprayem do
wykrywania nieszczelności ( powstają bąbelki).
• Po przeprowadzonym poszukiwaniu nieszczelności, można zacząć ostrożnie !!! spuszczać
gaz do atmosfery przez drugą złączkę serwisową lub przez ostrożne popuszczenie, (ale nie
całkowite odkręcenie!) połączenia szlaucha.
• UWAGA!! urządzenie jest pod wysokim ciśnieniem, przy spuszczaniu azotu przez szlauch
należy go mocno trzymać. Jeżeli szlauch się odłączy, zacznie w niekontrolowany sposób
uderzać wokół siebie, co może spowodować poważne urazy.
• Przed ponownym napełnieniem urządzenia klimatyzacyjnego chłodziwem należy jeszcze raz
opróżnić i wytworzyć wewnątrz próżnię by wydobyć ewentualne resztki azotu.
3. Zestaw do poszukiwania nieszczelności
na bazie gazu formującego
Przegląd produktu
Zestaw do poszukiwania nieszczelności na bazie
gazu formującego 5380 P1
1. 5380 680 złączka serwisowa ND niebieska
2. 5380 606 szlauch klimatyzacyjny niebieski 3 m
3. 5380 155 wózek do butli gazowych 10 l
4. 5380 161 urządzenie do poszukiwania nieszczelności przy pomocy gazu formującego
5. 5380 162 reduktor ciśnienia gazu formującego 20 bar
! WAŻNE !
Urządzenie klimatyzacyjne musi być całkowicie puste (bez ciśnienia) przed napełnieniem gazem
formującym. Ewentualne zawory magnetyczne powinny zostać manualnie otwarte przed
napełnieniem urządzenia gazem formującym, w ten sposób, iż pozostają pod napięciem
pokładowym. W ten sposób zostanie zapewnione, że także do tych obszarów urządzenia
klimatyzacyjnego dostanie się gaz formujący.
• Ogólny sposób postępowania jest taki sam, jak w przypadku poszukiwania nieszczelności
przy pomocy dwutlenku węgla.
• Dostarczony adapter jest tylko nałożony, należy przykręcić do odpowiedniego złącza przy
manometrze. Proszę koniecznie użyć odpowiedniej taśmy uszczelniającej (np. teflonu)
płynnego środka uszczelniającego do gazów.
• Proszę podłączyć reduktor ciśnienia do butli z gazem formującym (lewostronny gwint).
Proszę pamiętać o tym, by była nałożona biała uszczelka. Należy uważać by nakrętka
mocująca była odpowiednio przykręcona.
• Proszę upewnić się przed pierwszym uruchomieniem, że skierowany na dół kurek jest
przekręcony całkowicie w lewo ( w kierunku przeciwnym do kierunku ruchu wskazówek
zegara) oraz że zawór otwierający 1 jest zamknięty ( zgodnie z ruchem wskazówek zegara
przekręcony w prawo). Tym samym ciśnienie wyjściowe (prawy manometr) jest zerowe.
• Następnie proszę przyłączyć, dostarczony niebieski szlauch do chłodziwa, do adaptera
znajdującego się poniżej prawego manometru, a drugi koniec szlaucha przymocować do
szybkozłączki ND
• Teraz należy otworzyć zawór butli
• Lewy manometr wskazuje, po odkręceniu zaworu butli, ciśnienie butli.
Zawór
otwierający 1
Podłączenie butli
Regulator ciśnienia
←
←
←

Pacotes detectores de fugas Climatização
POR
1. Indicações gerais de segurança
1.1 Antes de começar a trabalhar com estes aparelhos, é indispensável ler atentamente todas
as indicações de segurança e de manuseamento.
1.2 Uma falta de atenção pode causar danos a pessoas e bens materiais, e pode ter
consequências mortais.
1.3 Estes aparelhos só podem ser manuseados por pessoas com a formação técnica
adequada e que possam apresentar a acreditação correspondente.
1.4 É necessário informar-se sobre as condições de manuseamento de agentes refrigerantes e
os seus óleos. Observe as fichas de dados de segurança. Estas são fornecidas pelo fornecedor
do agente refrigerante.
1.5 Observar as normas de manuseamento de botijas de gás, bem como as fichas de dados de
segurança dos gases técnicos utilizados. Estas são proporcionadas pelo fornecedor de gás.
1.6 Usar sempre os óculos de protecção correspondentes e a roupa de protecção prescrita
para trabalhar com agentes refrigerantes e os seus óleos.
1.7 Manter uma ventilação suficiente nos espaços interiores nos quais se trabalha com agentes
refrigerantes e os seus óleos.
1.8 Nunca exceder a pressão de trabalho permitida para o equipamento de climatização.
1.9 Para encher o equipamento de climatização com nitrogénio ou gás protector, este deve
estar sempre vazio (sem pressão). Se for necessário, evacuar previamente o agente
refrigerante e aplicar uma pressão negativa ao equipamento.
O hidrogénio é combustível! Por este motivo, para a detecção de fugas, deve-se utilizar
exclusivamente o gás protector indicado, com a concentração de 95/5!! Com esta concentração
não há perigo de incêndio e é totalmente suficiente para a detecção de fugas.
2. Pacote detector de fugas de nitrogénio
Descrição do artigo
Pacote detector de fugas com nitrogénio para
climatização 5380 P2
1. 5380 690 Acoplamento de serviço ND azul
2. 5380 606 Mangueira de climatização azul 3 m
3. 5380 714 Adaptador 1/4” x 1/4” SAE
4. 5400 45 Regulador de pressão para nitrogénio 20 bar
5. 5380 155 Carro para botijas de gás de 10 litros
Importante!
Antes do enchimento com nitrogénio, o equipamento de climatização deve estar
completamente vazio (sem pressão). Para poder detectar fugas de mudança de pressão,
o equipamento deve ser previamente submetido a um teste de retenção de vácuo.
As eventuais válvulas magnéticas devem-se abrir manualmente antes do enchimento com
nitrogénio, alimentando-as com tensão a bordo. Desta forma, fica assegurado que o nitrogénio
chegue também a estas zonas do equipamento de climatização.
• Mude o adaptador normal do manómetro de nitrogénio pelo adaptador fornecido de 1/4” x 1/4”
SAE. Utilizar uma fita vedante adequada (por ex. teflon) ou um vedante líquido para gás.
• Ligue o regulador de pressão à botija de nitrogénio. Verifique se o anel branco vedante está
colocado.Verifique se a porca de fixação está bem firme.
• Antes da primeira colocação em funcionamento, certifique-se de que o punho rotativo em
baixo está completamente virado para a esquerda (sentido contrário ao dos ponteiros do
elógio) e que a válvula de abertura 1 está fechada (no sentido dos ponteiros do relógio,
completamente para a direita). Deste modo, a pressão de saída (manómetro direito) fica sem
pressão.
• Ligue a mangueira de agente refrigerante fornecida ao adaptador montado previamente,
e una firmemente a outra extremidade da mangueira ao acoplamento rápido ND fornecido.
• Agora, abra a válvula da botija.
• Depois de abrir a válvula da botija, o manómetro esquerdo mostra a pressão da botija.
Válvula de
abertura 1
igação da botija
Regulador de
pressão
←
←
←

• Agora, ajuste lentamente a pressão de saída com o punho rotativo mostrado em baixo
(regulador de pressão) para a pressão de trabalho requerida (no sentido dos ponteiros do
relógio = aumentar a pressão).
• A seguir, efectue um teste de estanqueidade do pacote detector de fugas, abrindo lentamente
a válvula de abertura 1 e verifique se escapa gás (eventualmente utilizar um spray de
detecção de fugas).
• Se o pacote detector de fugas estiver estanque, adapte o acoplamento rápido ao
equipamento de climatização vazio. Abra a válvula rotativa do acoplamento rápido. Agora,
enche-se o equipamento com nitrogénio, com a pressão ajustada no manómetro.
• Quando o equipamento estiver cheio, feche a válvula da botija e observe a perda de pressão
(mín. 30 minutos), localize silvos e pulverize as tubagens com spray para detecção de fugas
(formação de bolhas) para encontrar pontos de escape.
• Finalizada a detecção de fugas, o gás pode ser purgado para a atmosfera cuidadosamente
(!!) através da segunda ligação de serviço, ou aliviando (sem retirá-la) cuidadosamente (!!)
a ligação de mangueira.
•PRECAUÇÃO! O equipamento encontra-se sob uma grande pressão! Prender a mangueira
firmemente durante o processo de purga do nitrogénio. Uma mangueira que se solte dá
chicotadas e pode causar lesões consideráveis.
• Antes de enchê-lo com agente refrigerante, o equipamento de climatização deve voltar a ser
evacuado e a ser aplicado vácuo para eliminar possíveis restos de nitrogénio.
3. Pacote detector de fugas – Gás protector (forming gas)
Descrição do artigo
Pacote detector de fugas de gás protector 5380 P1
1. 5380 690 Acoplamento de serviço ND azul
2. 5380 606 Mangueira de climatização azul 3 m
3. 5380 155 Carro para botijas de gás de 10 litros
4. 5380 161 Aparelho detector de fugas de gás protector
5. 5380 162 Regulador de pressão para gás protector
(mistura nitrogénio/ hidrogénio) 20 bar
Importante!
Antes do enchimento com gás protector, o equipamento de climatização deve estar
completamente vazio (sem pressão). As eventuais válvulas magnéticas devem-se abrir
manualmente, alimentando-as com tensão de bordo. Assim, garante-se que o gás protector
chegue também a estas zonas do equipamento de climatização.
• O procedimento básico é o mesmo que para a busca de fugas com nitrogénio.
• O adaptador fornecido está apenas colocado por cima. Enrosque o adaptador firmemente na
ligação correspondente do manómetro. É imprescindível utilizar uma fita vedante adequada
(por ex. teflon) ou um vedante líquido para gás.
• Ligue o regulador de pressão à botija de gás protector (rosca esquerda).Verifique se o anel
branco vedante está colocado. Verifique se a porca de fixação está bem firme.
• Antes da primeira colocação em serviço, certifique-se de que o punho rotativo em baixo está
completamente virado para a esquerda (sentido contrário ao dos ponteiros do relógio) e que a
válvula de abertura 1 está fechada (no sentido dos ponteiros do relógio, completamente para
a direita). Deste modo, a pressão de saída (manómetro direito) fica sem pressão.
• Ligue a mangueira de agente refrigerante fornecida ao adaptador por baixo do manómetro da
direita, e una firmemente a outra extremidade da mangueira com o acoplamento rápido ND
fornecido.
• Agora, abra a válvula da botija.
• Depois de abrir a válvula da botija, o manómetro esquerdo mostra a pressão da botija.
• Agora, ajuste lentamente a pressão de saída com o punho rotativo mostrado em baixo
(regulador de pressão) para a pressão de trabalho requerida (no sentido dos ponteiros do
relógio = aumentar a pressão).
• A seguir, efectue um teste de estanqueidade do pacote detector de fugas, abrindo lentamente
a válvula de abertura 1 e observe se escapa gás (eventualmente utilizar um spray de detecção
de fugas).
álvula de
abertura 1
Ligação da botija
Regulador de
pressão
←
←
←
This manual suits for next models
1
Table of contents
Languages:
Other Forch Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Bosch
Bosch GLM400CL Operating/safety instructions

Extech Instruments
Extech Instruments MultiScope 381270 owner's manual

Clarke
Clarke CDM90 Operating & maintenance instructions

Dwyer Instruments
Dwyer Instruments 477AV Series Specifications-installation and operating instructions

Minolta
Minolta COLOR METER IIIF - PART 1 manual

MICRODOS
MICRODOS MP2-HT TIMER Programming instructions