CARBON DIOXIDE CO2 MONITOR FD-CO2000
FORENSICS DETECTORSTM
!
** ATTENTION**
ØKEEP DETECTOR AWAY FROM ELECTROMAGNETC
& MAGNETIC INTERFERENCES STORE DETECTOR
WITHIN SPECIFICATIONS
ØDO NOT OPEN THE UNIT
ØKEEP AWAY FROM DUST & PARTICULATE AND
CONCENTRATED VAPORS, HARSH CHEMICALS
INTRODUCTION
You have purchased the BASIC CARBON DIOXIDE CO2
MONITOR by FORENSICS DETECTORSTM.This product
tracks indoor CO2 levels which is suited for classrooms,
home, offices, gyms, restaurants, hydroponics, cars and
transport vehicles. The monitor operates from any USB
charger. Your CO2 monitor is already calibrated so just
Turn ON and GO!
POWER & BATTERY CHARGING
The CO2000-USB version has a built-in lithium battery and
is charged when the CO2 monitor is powered via the USB
charger. When the USB is connected, the power LED will
be RED. When the monitor operates on battery power, the
battery icon on the top right will be displayed. The battery
operation can last for up over 8 hours. It takes about 2
hours to fully charge the battery.
OPERATION
ON/OFF:The ON/OFF power button is located on the back
of the CO2 monitor. Press the POWER button to turn On
the CO2 monitor. **BEWARE ** ensure you depress the
button completely; sometimes you may need a toothpick to
press it completely down. After a 10 second countdown
the CO2 monitor will display the instantaneous CO2 that it
detects in the ambient environment. The temperature,
humidity, date and time is also continuously displayed on
the LCD screen. LED indicators are located on the left to
indicate comfort levels SAD, NORMAL and HAPPY FACE.
Happy Face LED will show when below the Low Alarm set-
point. Normal face LED will show when CO2 level has
exceeded the Low Alarm set-point. Sad Face LED will show
when Hi alarm set-point has been exceeded.
MENU BUTTON:Press the MENU button on the right
hand side to scroll through the MENU selection options as
shown in the right table.
TIPS
•Press buttons very lightly when selecting.
•Battery model lasts over 8 hours.
•The monitor can be mounted on the wall as it
also has recessed indents to hook onto a screw.
•The USB cable can be plugged into any USB
port such as an existing USB charger.
•Check YouTube for video demonstration to help!
MODEL: FD-CO2000-USB
Battery & USB Power
MODEL: FD-CO2000-WALL
Wall Power Socket 110V AC
ON/OFF
BUTTON
Please use a
small item to
depress. Some
human fingers
are too big and
will not work
CARBON DIOXIDE CO2 MONITOR FD-CO2000
FORENSICS DETECTORSTM
!
!
! !
SPECIFICATIONS
CO2 Sensor Specifications
Sensor: Non Dispersive Infra Red NDIR CO2 sensor
CO2 Range: 0-5000ppm
Accuracy: ±50ppm or ±5% of reading (take larger)
CO2 Repeatability: 40ppm at 400ppm
Temp Compensation: ±0.1% of reading per C from 25C.
Response Time: < 1minute
Warm Up Time: 20 seconds
Temperature Sensor Specifications
Operate Temp: 32F–195F
Resolution: 0.1 (F or C)
Accuracy: ±5% of reading
Response Time: <1 minute
Relative Humidity Sensor Specifications
Range: 5-95%RH
Resolution: 1%
Accuracy: ±5% of reading
Response Time: <1 minute
General Specifications
Store/Operate Temp & %RH: 32F–122F, <95%RH
Voltage Input: USB DC 5V (use at least 1Amp charger)
Expected Sensor Life: up to 10 years
USB & Battery Version: Li-Ion battery 1000mAh;
Dimension/Weight: 120x90x35mm /170g (3.6oz);
Voltage Input: USB DC 5V via mini USB B type input
connector (USB charging cable included)
Wall Plug-in Version: 110V AC Power,
Dimension/Weight: 120x90x55mm /170g (3.3oz)
SEE PRODUCT DEMO ON
OUR YOUTUBE CHANNEL
MENU FUNCTIONS
Press the MENU button to scroll through the menu
selection as shown in the below icons. When a menu
option is selected it will FLASH. To select the MENU
press ENTER and then press UP and DOWN to toggle
the selection then press ENTER to select.
Mute/Silence Mode:Select this to silence
alarm or mute. When alarming, press any
button to engage MUTE.
Calibration Mode: When selected the
detector calibrates to 400ppm. Press
ENTER for 3 seconds. There will be 300-
second countdown. Ensure the detector is
in FRESH OUTDOOR AIR when calibrating.
Calibration should be performed every 6
months to ensure accuracy.
Alarm Settings: Select LOW or HIGH with
UP and DOWN arrows. Select to change
LOW and HIGH alarm CO2 levels. Default
alarm points are 800ppm for LOW and
1100 for HIGH.
Temp Selector:Select to toggle between
C and F temperature readings.
MAX: Select this option to view the
maximum CO2 recorded by the monitor.
To clear max, press UP button for 4 secs.
Time Date: Select this option to change
the date and time. Press ENTER to
scroll/select digits and UP and DOWN
arrows to change selection.
There may be added MENU functions on
some models due to firmware updates.
If you have any questions, please contact
us at [email protected]om
Product Tested, QA/QC in California, USA
Product Packaged in California, USA
Product Made in PRC
Copyright © 2020
!
WEB: www.forensicsdetectors.com
Email: [email protected]

This manual suits for next models

2

Other FORENSICS DETECTORS Gas Detector manuals

FORENSICS DETECTORS FD-60 User manual

FORENSICS DETECTORS

FORENSICS DETECTORS FD-60 User manual

FORENSICS DETECTORS FD-90E-RED User manual

FORENSICS DETECTORS

FORENSICS DETECTORS FD-90E-RED User manual

FORENSICS DETECTORS FD-91 User manual

FORENSICS DETECTORS

FORENSICS DETECTORS FD-91 User manual

FORENSICS DETECTORS 90E User manual

FORENSICS DETECTORS

FORENSICS DETECTORS 90E User manual

FORENSICS DETECTORS FD-VAPE-WALL User manual

FORENSICS DETECTORS

FORENSICS DETECTORS FD-VAPE-WALL User manual

Popular Gas Detector manuals by other brands

Figaro TGS2611 Application notes

Figaro

Figaro TGS2611 Application notes

yellow jacket 69373 Series Instruction and operation manual

yellow jacket

yellow jacket 69373 Series Instruction and operation manual

mumbi m-GM100 user manual

mumbi

mumbi m-GM100 user manual

SENKO SI-560D instruction manual

SENKO

SENKO SI-560D instruction manual

Crowcon IRmax Installation, Operating and Maintenance Instruction

Crowcon

Crowcon IRmax Installation, Operating and Maintenance Instruction

iSNATCH HeyGas manual

iSNATCH

iSNATCH HeyGas manual

mPower Electronics mSQUAD MP400S user guide

mPower Electronics

mPower Electronics mSQUAD MP400S user guide

SARAD Radon Scout Home manual

SARAD

SARAD Radon Scout Home manual

SENKO SI-H100 operating manual

SENKO

SENKO SI-H100 operating manual

Taichuan TC-U9AF-CO/Z installation instructions

Taichuan

Taichuan TC-U9AF-CO/Z installation instructions

EsiWelma Sensigas ESN26.C General instructions

EsiWelma

EsiWelma Sensigas ESN26.C General instructions

Dräger PEX 3000 manual

Dräger

Dräger PEX 3000 manual

Emerson Hart Rosemount 935 Reference manual

Emerson

Emerson Hart Rosemount 935 Reference manual

S&S Northern Merlin 1000BH Installation, operating and maintenance

S&S Northern

S&S Northern Merlin 1000BH Installation, operating and maintenance

Teledyne GASURVEYOR 7B-500R User handbook

Teledyne

Teledyne GASURVEYOR 7B-500R User handbook

GMI Gasurveyor 11-500 User handbook

GMI

GMI Gasurveyor 11-500 User handbook

SafeMi SHG-02 user manual

SafeMi

SafeMi SHG-02 user manual

mPower Electronics POLI MP400 user guide

mPower Electronics

mPower Electronics POLI MP400 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.