SENKO SI-H100 User manual


<< Operating Manual for Inhaled Gas Detector
1
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
Operating Manual
1. 일반 설명.......................................................................... 3
2. 제품 구성.......................................................................... 4
3. Overview .......................................................................... 5
4. 제품 사양.......................................................................... 6
5. 제품 각부의 구성 및명칭 ....................................... 7
1) 전면..................................................................7
2) 측면..................................................................8
3) 후면..................................................................8
4) 밑면..................................................................9
5) 제품 분해도....................................................9
6. able 결선 (Power board)......................................10
7. 외형도 (Dimensions)................................................11
....................................................................................................11
8. Key 안내.........................................................................12
1) Key Description........................................12
2) Key State .....................................................12
9. Power On.......................................................................13
10. Menu 동작..................................................................14
1) Normal Measurement Menu............15
2) Setup/Calibration/Review List 기본15
3) Setup/Calibration Menu 변경 기본15
4) SET 1..............................................................16
5) SET 2..............................................................18
6) SET 3..............................................................20
7) Calibration ..................................................21
8) Review...........................................................24
index

<< Operating Manual for Inhaled Gas Detector
2
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
9) Test mode...................................................24
11. MODBUS Address Map.......................................25
1) RS485 Interface setting.......................25
2) TCP Interface setting............................25
3) MODBUS RS485/TCP Register.........25
12. 설치 케이블 길이.....................................................28
13. Error Code ..................................................................29
14. 품질 보증(Warranty)..............................................30
15. 개정이력 .......................................................................30

<< Operating Manual for Inhaled Gas Detector
3
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
1. 일반 설명
흡입식 가스감지기(SI-H100)는케이스 내부에 있는 센서 카트리지를 통하여 샘플 가스를 원격으
로흡입하여 실시간으로 측정합니다. 반도체나 여러 산업 현장에서 사용되거나 발생할 수있는
다양한 가스관련 사고(질식, 중독, 화재 및폭발, 부식 등)를미연에 방지하거나 관리할 수있도
록도움을 줄수있는 장비입니다.
SI-H100은기본적으로 벽에 부착하여 고정적으로 가스농도를 실시간으로 측정하고 위험농도의
경보, FAULT 상황 등을 대형 디스플레이를 통하여 보여줍니다.
화면 하단의 4개의 버튼을 조작하여 기기의 환경설정을 쉽게 수정할 수있습니다.
측정된 가스농도를 기본 4-20mA출력으로 실시간으로 전송하고, 3개의 내부 릴레이를 통하여 원
하는 상황에 따른 외부 동작을 다양하게 구성할 수있습니다. 또한 MODBUS/TCP 출력도 가능하
며, LAN선하나만을 통하여 데이터 송수신 및전원까지 한번에 해결(PoE)이가능합니다.
WARNING
기기 사용 전매뉴얼을 충분히 숙지하십시오. 이기기는 지시서에 따라 사용하고 보수하여야 하며
지시를 따르지 않을 시기기 고장을 일으키거나 사용자의 부상 또는 생명에 위험을 초래할 수있습니다.

<< Operating Manual for Inhaled Gas Detector
4
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
2. 제품 구성
SI-H100은케이스, 센서 카트리지, 메인 프레임, 설치 조립 받침대 이렇게 총4부분으로 구성되
어있습니다.
또한, NF3등과 같이 일반적으로 검지할 수있는 가스센서가 없는 물질의경우에도 열분해를 통
하여 검지 및측정할 수있도록 열분해 모듈(Pyrolyzer) 악세사리를 보유하여 별도 구매 시추가
장착 하여 사용 가능합니다.

<< Operating Manual for Inhaled Gas Detector
5
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
3. Overview
Figure 1 Overview

<< Operating Manual for Inhaled Gas Detector
6
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
4. 제품 사양
항목
사양
크기
124mm(H) X 65mm(W) X 155mm(D)
중량
2Kg
동작 전압
DC : 24V ± 10%
PoE : 36V~57V (Typical : 48V)
유량
500mL/min (MAX 900)
소비 전력
약5.0W
측정 표시
Graphic LCD (160 X 100), 가스농도, 유량,
알람, 백라이트, 경보, 기기 이상
Relay
1차Alarm, 2차Alarm, Fault Alarm
Analog 측정 출력
4-20mA
Digital 통신
RS-485, TCP Ethernet
샘플링 거리
입력 가스 튜브 길이 : 최대 30m (FEP 튜브)
배출 가스 튜브 길이 : 최대 30m (FEP 튜브)
입/출력 튜브 규격
1/4” Teflon tube
사용 온도
0°C ~40°C
인증
CE
입력 및세팅
4 Button & RS485 & Ethernet
기기 보증기간
2년
센서 카트리지 보증기간
1년
원격 인터페이스
Ethernet , RS-485
배선
4 to 20mA / DC전원 / Relay : 최대 14 AWG

<< Operating Manual for Inhaled Gas Detector
7
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
5. 제품 각부의 구성 및명칭
1) 전면
Power LED(Green)
Alarm1 LED(Red)
Alarm2 LED(Red)
Fault LED(Red)
LCD
Menu button
Down button
UP button
Select button
Sensor cartridge window
Thumb screw
Gas inlet port
Gas outlet port
Cable Gland

<< Operating Manual for Inhaled Gas Detector
8
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
2) 측면
3) 후면
Unit cover
Mount bracket hole
cover

<< Operating Manual for Inhaled Gas Detector
9
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
4) 밑면
5) 제품 분해도
Ethernet/PoE socket
Unit cover
Sensor cartridge
Mounting bracket assembly
Main sampling assembly
Main sampling assembly & bracket assembly fixed screw
Cable Gland
Gas inlet port
Gas outlet port
Locking tabs

<< Operating Manual for Inhaled Gas Detector
10
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
6. able 결선 (Power board)
Power ON/OFF switch
Ethernet/PoE socket
PoE로전원 공급 시
PoE 스위치 허브 사용
해야함
Power cable : DC 24V
Power cable : Ground
ALARM LOW(2차) Relay
ALARM HIGH(2차) Relay
Fault Relay
RS-485 : A
RS-485 : B
4to20mA out : Signal
4to20mA out : Ground
High(2차) Alarm Jumper : 1-2 :NC /2-3:NO
Low(1차) Alarm Jumper : 1-2 :NC /2-3:NO
Fault Jumper : 1-2 :NC /2-3:NO

<< Operating Manual for Inhaled Gas Detector
11
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
7. 외형도 (Dimensions)

<< Operating Manual for Inhaled Gas Detector
12
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
8. Key 안내
1) Key Description
Key
Name
Description
Menu
Menu/취소 & 이전단계 복귀
Up
List Focus 이동 및값변경
Up Long
Setting 화면 Focus 이동
Down
List Focus 이동 및값변경
Down Long
Setting 화면 Focus 이동
Select
선택 및저장
2) Key State
State
Pressed Time
Description
Normal Key
100ms below
Menu 변경 및설정 값변경
Long Key
1000ms over
각설정에서 Focus 앞/뒤이동

<< Operating Manual for Inhaled Gas Detector
13
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
9. Power On
①전원 전압을 확인 후결선
②Power LED(Green)가점등이 되고, Version 정보 표시 후측정(Measure)상태로 전환
③소요 시간은 약15sec
Booting 및Warm up
측정(Measure)

<< Operating Manual for Inhaled Gas Detector
14
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
10. Menu 동작
- Menu키를 누르면 Normal →SET 1 →SET 2 →SET 3 →CAL 으로 순환 변경
- Normal에서 Select키를 누르면 Review진입하고, Menu키를 누르면 Review에서 Normal 복귀
[Power On]
[Normal Measure]
[SET 1]
[SET 2]
[SET 3]
[Calibration]
[Review]

<< Operating Manual for Inhaled Gas Detector
15
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
1) Normal Measurement Menu
현재 시간 : 24시간제 표시
현재 센서 Gas Type 및농도 단위
- O3 : 장착된 센서의 측정 Gas Type
- ppm : 농도 단위
Gas 측정 농도
- 센서의 측정 범위에 따라 소수점 자리가 변경 됨.
Sensor On/Off State
Pump 유량
- 현재 흡입하는 유량
2) Setup/Calibration/Review List 기본
1. 우측 상단에 현재 Menu 표시
- SET1, SET2, SET3, CAL, REVIEW
2. Up/Down 키를 통해 List Focus 이동
3. Select 키를 누르면 해당 설정 화면 진입
- 해당 항목이 설정이 불가능한면 화면
전환 없음
4. Menu키를 누르면 다음 Menu로변경
3) Setup/Calibration Menu 변경 기본
Focus가있는 Menu
1. Up/Down 키로 0~9 숫자 변경
2. Up/Down Long 키를 통하여 Focus 이동- Down Long
키입력 시3 →6 →5 →3
순서로 Focus 이동
3. 설정 범위가 넘어 가는 숫자가 입력된 상태에서 Focus
가이동하면 Max값이나 유효한 값으로 자동으로 변경
됨
1
4
5
2
3

<< Operating Manual for Inhaled Gas Detector
16
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
Focus가없는 Menu
1. Up/Down 키를 통하여 숫자 변경
2. Up/Down Long 키를 입력하면 숫자가 지속적으로 증가
하거나 감소함.
4) SET 1
1) Gas Name : 현재 장착된 스마트 센서의 Gas Type
2) Gas Unit : Gas 농도 단위
3) CAL Interval : Calibration 수행 주기 설정
4) Pump Freq : Gas 흡입 Pump의Frequency 설정으로 흡입량 조정
5) Pass Code : Setup 및Calibration 진입 암호 설정
6) Inhibit : Inhibit할항목 설정
7) Buzzer : Alarm 발생 시Buzzer On/Off
8) Resp Factor : Gas 농도의 미세 조절 수치
9) Sensor Off : Sensor가On후에 자동으로 Off되는 시간 조정(VOC센서 전용)
10) Hidden Area : Gas Range의일정%를Hidden Area로처리하여 가스농도를 0으로처리
11) RS485 Addr : RS485통신 시기기 Address 설정
Gas Unit
▶Up/Down 키를 눌러서 농도 단위 조정
▶Menu키로 설정 취소, Select키로 설정 저장
▶ppm/ppb/Vol/LEL 설정 가능
▶Default : ppm
CAL Interval
▶Up/Down 키를 눌러서 설정 숫자(0~9) 조정
▶Up/Down Long 키를 눌러서 Focus 이동
•Up Long : 왼쪽으로 Focus이동
•Down Long : 오른쪽으로 Focus이동
▶Menu키로 설정 취소, Select키로 설정 저장
▶0 ~ 999 days까지 설정 가능
▶Default : 365 days

<< Operating Manual for Inhaled Gas Detector
17
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
Pump Frequency
▶Up/Down 키를 눌러서 설정 숫자 조정
▶Up/Down Long 키를 눌러서 지속적으로 숫자 조정
▶Menu키로 설정 취소, Select키로 설정 저장
▶Flow : 현재 유량 표시
▶Default : 60 Hz
Pass Code
▶Up/Down 키를 눌러서 설정 숫자(0~9) 조정
▶Up/Down Long 키를 눌러서 Focus 이동
•Up Long : 왼쪽으로 Focus이동
•Down Long : 오른쪽으로 Focus이동
▶Menu키로 설정 취소, Select키로 설정 저장
▶2회같은 Pass Code 입력해야 정상적으로 설정
▶Pass Code가0000이아닌 값으로 설정 시에는 Menu
키로 설정 진입 시Pass Code를입력해야 진입 가능
▶Default : 0000
Inhibit
▶Up/Down 키를 눌러서 Inhibit 항목 설정
▶Menu키로 설정 취소, Select키로 설정 저장
▶None : Inhibit 없음
Alm : Alarm Inhibit
Alm&Flt : Alarm, Fault Inhibit
Full : 모든 항목 Inhibit
▶Default : None
Buzzer
▶Up/Down 키를 눌러서 Buzzer On/Off 설정
▶Menu키로 설정 취소, Select키로 설정 저장
▶On : Alarm시에 Buzzer 울림
Off : Alarm시에 Buzzer 울리지 않음
▶Default : On
Resp Factor
▶Up/Down 키를 눌러서 설정 숫자(0~9) 조정
▶Up/Down Long 키를 눌러서 Focus 이동
•Up Long : 왼쪽으로 Focus이동
•Down Long : 오른쪽으로 Focus이동
▶Menu키로 설정 취소, Select키로 설정 저장
▶해당 설정된 값이 최종 농도에 곱하여 출력됨
▶Default : 1.00

<< Operating Manual for Inhaled Gas Detector
18
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
Sensor Off Time
▶Up/Down 키를 눌러서 설정 숫자 조정
▶Up/Down Long 키를 눌러서 지속적으로 숫자 조정
▶Menu키로 설정 취소, Select키로 설정 저장
▶Sensor 자동 Off 시간: Off(Always On), 1~120 초
•VOC 센서(PID) 전용 Menu
•해당 시간이 지나면 Sensor Power Off
▶Default : Off
Hidden Area
▶Up/Down 키를 눌러서설정숫자(0~9)조정
▶Up/Down Long 키를눌러서Focus 이동
-Up Long : 왼쪽으로Focus이동
-Down Long : 오른쪽으로Focus이동
▶Menu키로 설정취소, Select키로 설정 저장
▶Gas Range에서 설정된 %이하의 값은 0으로 처리 (Gas
Range가100ppm이고 2.00%로설정되면, 2ppm이하의
값은 0으로 출력됨)
▶Default : 0.00(%)
RS485 Addr
▶Up/Down 키를 눌러서 설정 숫자 조정
▶Up/Down Long 키를 눌러서 지속적으로 숫자 조정
▶Menu키로 설정 취소, Select키로 설정 저장
▶RS485 Address(ID) : 1 ~ 247
▶Default : 1
5) SET 2
1) Alarm 1 : Alarm Level 1(Low) 설정
2) Alarm 2 : Alarm Level 2(High) 설정
3) Alarm Delay : Alarm 1, 2 농도에 도달 시정해진 시간 후에 Alarm이발생함
4) Alarm Latch : Alarm 발생 후자동/수동으로 해제할 것인지 설정
5) Alarm Relay : Alarm 발생 시Relay를동시에 동작 시킬 것인지 설정
6) Fault Latch : Fault 발생 후자동/수동으로 해제할 것인지 설정
7) Fault Relay : Fault 발생 시Relay를동시에 동작 시킬 것인지 설정

<< Operating Manual for Inhaled Gas Detector
19
©Senko 2019. All Rights Reserved Proprietary and Confidential to Senko
Alarm 1
▶Up/Down 키를 눌러서 설정 숫자(0~9) 조정
▶Up/Down Long 키를 눌러서 Focus 이동
•Up Long : 왼쪽으로 Focus이동
•Down Long : 오른쪽으로 Focus이동
▶Menu키로 설정 취소, Select키로 설정 저장
▶Alarm Level 1 : 0 ~ 9999.9 ppm
▶Default : 50.0 ppm
Alarm 2
▶Up/Down 키를 눌러서 설정 숫자(0~9) 조정
▶Up/Down Long 키를 눌러서 Focus 이동
•Up Long : 왼쪽으로 Focus이동
•Down Long : 오른쪽으로 Focus이동
▶Menu키로 설정 취소, Select키로 설정 저장
▶Alarm Level 2 : 0 ~ 9999.9 ppm
▶Default : 100.0 ppm
Alarm Delay
▶Up/Down 키를 눌러서 설정 숫자(0~9) 조정
▶Up/Down Long 키를 눌러서 Focus 이동
•Up Long : 왼쪽으로 Focus이동
•Down Long : 오른쪽으로 Focus이동
▶Menu키로 설정 취소, Select키로 설정 저장
▶Alarm Delay : 0 ~ 99 초
▶Default : 0 초
Alarm Latch
▶Up/Down 키를 눌러서 Alarm Latch 설정
▶Menu키로 설정 취소, Select키로 설정 저장
▶On : Alarm 발생 후Alarm 조건이 해제되어도 Alarm이
해제되지 않음
Off : Alarm 발생 후Alarm 조건이 해제되면 자동으로
Alarm이해제됨
▶Default : Off
Alarm Relay
▶Up/Down 키를 눌러서 Alarm Relay 설정
▶Menu키로 설정 취소, Select키로 설정 저장
▶On : Alarm 발생 시Relay 동작
Off : Alarm 발생 시Relay 동작하지 않음
▶Default : On
Other manuals for SI-H100
1
Table of contents
Other SENKO Gas Detector manuals

SENKO
SENKO SI-100 User manual

SENKO
SENKO SI-H100 User manual

SENKO
SENKO SP secure User manual

SENKO
SENKO iGas Detector CO2 User manual

SENKO
SENKO SI-560D User manual

SENKO
SENKO SI-100C User manual

SENKO
SENKO SI-100 User manual

SENKO
SENKO SI-300 User manual

SENKO
SENKO SGT-P User manual

SENKO
SENKO SP-MGTP User manual