1. INTRODUCTION
The 90E portable gas detector is a state-of-the-art gas leak detector. We employ
the best Japanese high quality semi-conductor sensor and embedded
microcontroller to detect gas leakage with high sensitivity and fast reaction time.
The detector is waterproof, dustproof, explosion-proof, and easy to use with
super high reliability. This detector is widely used in oil, coal, municipal
construction, chemical engineering, environmental protection, metallurgy,
refining, gas transmission and distribution, biochemistry, agriculture and
pharmaceutical industries.
2. FEATURES & SPECIFICATIONS
ACCURATE: Accurate Made in Japan sensor, most sensitive with ppm (0-10,000ppm)
concentration display. Comes FACTORY CALIBRATED. Turn ON and GO.
ALARMS: Adjustable Audio, visual, and vibration alarms alert when preset levels are reached.
COLOR DISPLAY: Large LCD screen. Shock proof, water proof, dust proof and explosion proof.
USES: Designed for inspectors, utility workers, refinery workers, maintenance engineers and
technicians.
TRUST: ** 1 year limited warranty ** Arrives with calibration and QA certificate ** 100% product
test and verification in the USA ** 100% quality guaranteed **
Target gas
Combustible gas
Range
0-10,000ppm (based on Methane) 0-1,000ppm for Hydrogen
Sampling method
Natural diffusion
Alarm point
Default: Low alarm: 500ppm; High alarm: 2000ppm.
Alarm types
Audible buzzer alarm; Visual LED light alarm; Vibration alarm
Warm-up time
60S
Response time
<30s
Protection level
IP65
Explosion-proof grade
Exib IIB T3 Gb
Sensor type
Japanese FIGARO sensor
Sensor life
2 years
Power supply
Rechargeable lithium battery, DC3.7V 1800mAH
Charging Time
6h-8h
Operating Time
> 8 hours (normal working environment)
Working conditions
Temperature: -10~40℃Humidity: ≤95% RH with no condensation.
Storage
Temp: -20~50℃Humidity: ≤90% RH, avoid caustic gases or substances.
Weight
Approx. 300g (excluding accessories)
Dimension
Approx. 210mm(L)×66mm(W)×30mm(H)
Packing list
Detector, Carrying case, Charger, USB cable

FORENSICS DETECTORSTM
www.forensicsdetectors.com
!
3. Configuration and Functions
Fig1.
4. Operation & Function
4.1 Display Icons
20.0℃
Temperature
13:01
Time
Full voltage
0PPM
Concentration value
Low voltage
Normal
Status
Clear
zero clearing
Sound
Info
Information
Muting
4.2 Turn ON
Press the button for 3s and then release it. The interface shows “Welcome Starting”, “LED Testing”, and then
vibrates with “Motor Testing”, then beep and flashes with “Sound and Alarm Testing”, after “60s warming”, it enters into
detecting status.
At this time, it displays the combustible concentration in the environment.
4.3 Menu Operation Instructions
The interface menu contains: 【Clear】, 【 】, 【Info】.
【Clear】: press the key !for 2 seconds after the instrument into the clear state, and save the value of the display was
successful.
【 】: Press the key !to switch to the silent state, display , and then press the button to switch to the sound
state.
【Info】: press the key !to display the status information, including battery power, low value, high value and range (see
below).
1
LED lights
5
USB Charging
socket
2
Label (back)
6
Buzzer hole
3
Operation buttons
7
Gas sensor
4
LCD screen
20.0℃13:01
0PPM Norm.
Clear !!!!!Info
1/5 Menu
> Low alarm
High alarm
Gas calib
1/5 Menu
> Time set
Shut down
Language
BAT 4.0V 100%
Low 500ppm
High 2000ppm
Range 10000ppm

FORENSICS DETECTORSTM
www.forensicsdetectors.com
!
Press the button !for 2 seconds to enter the user menu, including the following options: low alarm set, high alarm set,
gas calibration, time set, shutdown. Press the button !for the down button, press the key !for the return, !to
confirm.
【Low alarm set】Press the key to move the cursor to Low alarm set, press !to enter the editing state, then press
the !button you can increase the value of the black position, press the button !to reduce the black position value,
press the button !to switch to the next digit value to adjust, when the switch to the last bit when displayed (right figure),
press the key !to save then the low alarm setting is done.
【High alarm set】Press the key to move the cursor to High alarm set, press !to enter the editing state, then press
the !button you can increase the value of the black position, press the button !to reduce the black position value,
press the button !to switch to the next digit value to adjust, when the switch to the last bit when displayed, press the
key !to save then the high alarm setting is done.
【Gas calibration】: This option for the special operation, please email FORENSICS DETECTORS for operation.
【Time setting】: press the !key to move the cursor to time setting, press to enter the editing interface, then you
can adjust the years, press the !key black position move to the last two position, through and can be achieved to
increase and decrease, in turn adjust the time, when switching to seconds when the interface, press to save the
settings to complete the time adjustment.
【Shutdown】: There are two ways to shut down the detector:
Method 1: press the in any interface, press for 3 seconds to automatically shut down to confirm the interface,
press or press to shut down.
Method 2: enter the user menu, switch to the shutdown menu option, press the !key to enter the shutdown
confirmation interface, press the !key to shut down.
4.4 Menu Operation Instructions
LOW alarm: the status indicator shows low alarm, the instrument issues a slow drop alarm sound, while the red alarm
light slowly blinking and vibration.
HIGH alarm: status indicator shows the high alarm, the instrument issues a rapid drop of the alarm sound, while the red
alarm light flashing and rapid vibration.
OVERRUN alarm: status indicator shows overrun, the instrument has issued an alarm sound, while the red alarm light
and backlight.
4.5. BATTERY Charging
Use the USB charger provided. If the battery is low the detector will not be able to turn ON. Before charging,
please turn off the detector to avoid any potential damage. When the battery mark on the screen is full and
doesn’t charge any more, it means the charging is complete.
!
Low alarm set
00500ppm
- > +
Low alarm set
00500ppm
- save +
Low alarm set
00500ppm
Back Edit
High alarm set
02000ppm
- > +
High alarm set
02000ppm
- save +
High alarm set
02000ppm
Back Edit
Edit date
2016-01-06
08:11:20
-> +
Edit date
2016-01-06
08:11:20
- save +
Edit date
2016-01-06
08:11:20
Back Edit

FORENSICS DETECTORSTM
www.forensicsdetectors.com
!
**!WARNING **
lDO NOT turn on the detector when it’s off and being charged.
lDO NOT charge the detector at leak detection site. Explosions may be caused by
sparks introduced from plugging / unplugging the charger.
lDO NOT charge the detector when it is ON.
lPrevent dropping the detector and vibrations.
lDO NOT use sensor tip to touch other objects nor block sensor tip.
lThe detector will only detect gas concentration when in the main screen.
lThe detector should not be stored or used where there are caustic gases (such as
CL2), or under other rigorous circumstances (no excessive high and low
temperature, high humidity, electromagnetic field and sunlight).
lAfter long-term use, if there is dust on detector surface, please clean it lightly with
clean soft cloth, instead of caustic solvents or hard things.
5. Customer Support