4036865-012 0112 50112 036865-012
KER1P watER filtRation
UndER SinK ChillER Unit inStallation inStRUCtionS
and USE and CaRE GUidE
KER1P watER filtRation
UndER SinK ChillER Unit inStallation inStRUCtionS
and USE and CaRE GUidE
loCation REQUiREMEntS
IMPORTANT: Faucet is sold separately and requires a 1 3/8" (3.5cm) diameter opening in sink or countertop. Spout can be installed in place of
sink spray hose. If faucet is not to be installed in sink spray hose opening, it is recommended that a qualified installer be contacted to drill a hole
through your type of sink or countertop. Thickness of countertop at the hole must not exceed 1 3/4" (4.4cm) . For best performance, allow a 2"
(5 cm) space around the side and the top. Do not put any objects on top of the chiller that could obstruct the fan.
3
2
1
4
5
6
78
9
5
01
11
21
21
31
14.75
"
[37.47 cm]
10.30
"
[26.16 cm]
8.72
"
[22.14 cm]
1. Chiller unit
2. Blue tubing included
with chiller
3. Faucet is required
(sold separately)
4. Cold water supply line
5. White tubing included
with faucet
6. Dual filtration
sold separately
7. Unit C sold separately
8. Flow monitor included
with faucet
9. “T” water line connector
included with faucet
10. White “water in” collet
11. Blue “water out” collet
12. “T” quick connect fitting
13. Check valve
ElECtRiCal REQUiREMEntS
A 120-volt, 60-Hz, 15- or 20-amp, grounded electrical supply is required. It is recommended
that a separate circuit serving only your chiller unit be provided. Use an outlet that cannot be
turned on/off by a switch.
RECOMMENDED GROUND METHOD - The chiller must be grounded. This appliance is
equipped with a power supply cord with a 3 prong ground plug. To minimize possible shock
hazard, the cord must be plugged into a mating, 3 prong, ground-type outlet, grounded in
accordance with all national and local codes and ordinances. If a mating outlet is not available,
it is the personal responsibility and obligation of the customer to have a properly grounded, 3
prong outlet installed by a qualified electrician.
WARNING
ELECTRICAL SHOCK HAZARD
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Failure to follow these instructions can result
in death, fire, or electrical shock.
watER SUPPlY REQUiREMEntS
If local codes permit, the chiller feed line should be connected to the cold water supply line with the “T” water line connector included with the
faucet (sold separately). If you are using a filtration unit, the chiller should be connected after the filtration unit.
IMPORTANT: If local codes do not permit the use of the “T” water line connector, special feed valves can be obtained from your local plumbing
supply retailer. The water pressure to the chiller should be between 30 psi (MIN) and 100 psi (MAX).
inStallation inStRUCtionS
inStall thE ChillER
NOTE: Tubing must be cut to fit. All tubes must be cut squarely with no
burrs. All tubing connections must be fully seated. Tubing must be routed to
avoid sharp bends and have enough slack to avoid straining connections. A
P-clip and mounting screw is included to hold the tubing in place as needed.
Pull gently on each connection to make sure they are secure.
IMPORTANT: After chiller is unpacked, place chiller upright for 24 hours
before plugging it in.
1. Determine where you will install your chiller. See “Location
Requirements” section.
2.
For best performance, allow a 2" ( 5 cm) space around the side and the top.
Do not put any objects on top of the chiller that could obstruct the fan.
3. Shut off water supply valves.
4. Install KER1P faucet sold separately. See faucet’s
Installation instructions.
5. Using the white tubing included with the faucet (sold separately),
connect one end to the chiller (water in) and the other end to the flow
monitor outlet (blue collet) . (See Figure 1)
NOTE: If you are installing the chiller with a filtration system, follow steps 6a.
to 13. Following these steps will avoid the possibility of excessive pressure
building as the chilller cycles on and off. If you are NOT installing t he chiller
with a filtration system, follow steps 6b. and 10 to 13.
6a. Connect “T” (part 12) to “water out” chiller tube. Connect blue tubing
between “T” and faucet, sold separately. (see Figure 2)
6b. If you are NOT installing a filtration system, connect blue tubing between
the “water out” chiller tube and faucet, sold seperately. Do NOT use
“T” quick connect fittings (part 12) or check valve (part 13).