Frico Sunnan SUN30 User manual

Sunnan SUN30
.... 2
EN .... 12
SE
Original instructions
.... 22
NO

SUN30
2
Read the user manual carefully before operation.
Further information is available in the user manual, service manual, and in
the safety instructions for service.
Service personnel are required to carefully read the user manual and
service manual before operation.
Recycle unwanted materials instead of disposing of them.
All appliances and packaging should be sorted and tendered at a regional
recycling centre and be processed in an ecological manner.
This unit uses a ammable refrigerant.
If refrigerant leaks and comes in contact with re or heating part, it will
create harmful gas and there is risk of re.
IMPORTANT: Keep this manual for future reference.
EN

SUN30
3
Product Instructions
The dehumidier is used to remove excessive
moisture from the air. The resulting reduction
in relative humidity protects buildings and their
contents from the adverse effects of excess
humidity. The dehumidier is portable and is
designed for dehumidifying various premises.
The dehumidier has been approved for damp
and wet areas, and is used for applications
such as building sites, industrial premises,
warehouses, and in the home.
Degree of protection: IPX4 (corresponds to
splash-proof). The dehumidier is
stackable, at a height of two, for storage on the
oor. The environmentally friendly R290 is used
as the refrigerant.
Special precautions must be taken into
consideration due to the coolant’s high
ammability. The dehumidier is CE marked
and approved by Intertek according to EN
60335-1, EN 60335-2-40, EN 62233, EN 55014-1,
EN 55014-2, EN 61000-3-2 and EN 61000-3-3.
Safety Instructions
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made by
children without supervision.
Children of less than 3 years should be kept
away unless continuously supervised.
Children aged from 3 years and less than 8
years shall only switch on/off the appliance
provided that it has been placed or installed
in its intended normal operating position and
they have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
aged from 3 years and less than 8 years shall
not plug in, regulate and clean the appliance or
perform user maintenance.
The unit is designed only for use with
R-290(propane) gas as the designated
refrigerant.
The refrigerant loop is sealed. Only a qualied
technician should attempt to service.
Do not discharge the refrigerant into the
atmosphere. R-290 (propane) is ammable and
heavier than air.
It collects rst in low areas but can be
circulated by the fans.
If propane gas is present or even suspected,
do not allow untrained personnel to attempt to
nd the cause.
The propane gas used in the unit has no odor.
The lack of smell does not indicate a lack of
escaped gas.
If a leak is detected, immediately evacuate all
persons from the store, ventilate the room and
contact the local re department to advise them
that a propane leak has occurred.
Do not let any persons back into the store until
the qualied service technician has arrived and
that technician advises that it is safe to return
to the store.
Leave the unit to stand for one hour before
connecting to the mains supply after transport
or when it has been tilted (e.g. during cleaning)
Always keep the unit in an upright/vertical
position.
The mains supply must conform to the
specication shown on the rating plate of the
unit.
Never use the plug to start and stop the unit.
Always use switch on the control panel.
Before moving the unit, rst switch off, then
unplug and empty the water tank.
Don’t use ammable cleaners on the unit.
Never pour or spray water over the unit.
Component parts are designed for propane and
non-incentive and non-sparking. Component
parts shall only be replaced with identical repair
parts.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualied persons in order to avoid a
hazard.

SUN30
4
Safety Instructions
The appliance shall be disconnected from its
power source during maintenance.
Ensure the unit is far away from re,
inammable, or explosive objects.
Do not use means to accelerate the defrosting
process or to clean, other than those
recommended by the manufacture.
The appliance shall be stored in a room without
continuously operation sources (for example:
open ames, an operating gas appliance or an
operating electric heater).
The appliance shall be stored so as to prevent
mechanical damage from occurring. Do not
piece or burn, even after use.
Pipe-work shall be protected from physical
damage and shall not be installed in an
unventilated space, if that space is smaller than
4 m².
Compliance with national gas regulations shall
be observed. Keep any required ventilation
openings clear of obstruction.
The appliance shall be stored in a well-ventilated
area where the room size corresponds to the
room area as specied for operation.
Warning
Failure to abide by this warning could result
in an explosion, death, injury and property
damage.
Any person who is involved with working on
or breaking into a refrigerant circuit should
hold a current valid certicate from an
industry-accredited assessment authority,
which authorizes their competence to handle
refrigerants safely in accordance with an
industry, recognized assessment specication.
Servicing shall only be performed as
recommended by the equipment manufacturer.
Maintenance and repair requiring the
assistance of other skilled personnel shall
be carried out under the supervision of the
person competent in the use of ammable
refrigerants.
Placement
When positioning the dehumidier, ensure that
it is placed on a level surface and that there is
a minimum of 50 cm of space on either side
of the unit to allow for ecient airow. This
dehumidier is tted with castors for extra
mobility, if you move the unit, it should rst be
switched off and the water tank emptied.
We do not recommend the use of an extension
lead, so please try to ensure that the unit is
suciently close to a xed mains socket.
When the dehumidier is in operation, front
doors and windows should be closed when
necessary for most ecient use.
Important!
To prevent the possibility of a heavily ice build
up on the evaporating coil, do not use this unit
at ambient temperatures below 8°C.

SUN30
5
Parts and accessories
1. Handle
2. Control panel
3. Operating hour meter
4. Air lter
5. Condensate collecting container
6. Adapter for continous drain. Placed in the
condensate collection container.
Storage
If the unit not is used for an extended period of
time. Please:
Turing the unit off and unplug the cord set.
Completely empty the water tank and wipe it
clean.
Cover the unit and store where it will not
receive direct sunlight.
Keeping od more than one dehumidier
Make sure that the rubber feet are placed in the
hollows. NOTE! A maximum of two units can be
placed on top of each other.
Control panel
1. Plug the unit into a 230V earthed socket.
2. Press the ON/OFF button to turn on the
unit. The dehumidier will start to work in
CONT mode (dehumidies continously). If the
dehumidier isn´t turned off by the ON/OFF
button or has been turned off for at least 3 min.
the start of the compressor will be delayed for
3 min.
3. Press button HUM to set the room humidity
you require: continuous de-humidifying, 40%,
50%, 60% or 70%. When the room humidity is
under 35%, the display will show ‘LO’ and if the
room humidity is over 95%, it will show ‘HI’. If
the fan speed HI is selected, it will change to LO
when the compressor stops and change to HI
again when the compressor starts.
4. Press the speed button to choose the
ventilation speed, high or low.
5. Press the timer button to set the time
for operation (1~24hr). The unit will be
continuously de-humidifying if no time is set.
6. To turn off the unit, press the ON/OFF button
again.
1 Timer (button, adj. 1-24 hours)
2 Timer operation indicator
3 Humidity selection button
4 Humidity indicator
5 “WATER FULL” indicator
6 Low speed indicator
7 Speed (ventilation)
8 High speed indicator
9 ON/OFF(power) indicator
10 ON/OFF button
11 Display window (displays hum.)

SUN30
6
Operating hour meter
1. The operating hour meter counts the
compressor operating time.
2. The 5 rst digits shows the operating time in
hours.
3. The operating hour meter will count-on
continuously and never reset back to “zero”.
Drainage
When the condensate collection container
is full, the dehumidier will stop for self-
protection and the “Water Full” indicator will
show a red light and the buzzer will sound.
To remove the container, pull it out squarely
from the unit.
After empting the container, put it back into
position. Make sure it is properly positioned,
in order for the ’water full’ sign to go out and
your dehumidier is operating. Please note, in
case, the water tank has not been positioned
correctly, the water full indicator will turn into
red.
Continuous drainage
When the dehumidier is operated at high
temperatures and high humidity levels, the
water tank will require more frequent drainage.
In this situation, it may be more convenient to
set the unit up for continuous drainage with the
following procedure:
1. Pull out the container.
2. Connect the drain hole inside the unit with
the supplied “adapter for continuous drain”.
3. Connect the adapter to a water hose with an
inner diameter of 12 mm (this water hose is not
supplied along with the unit).
4. Ensure the water will always drain away
freely and the hose remains in the right place.
NOTE! In cold weather conditions, precautions
should be taken to prevent the water in the hose
from freezing.
Maintenance
Always unplug the unit from the mains before
carrying out any maintenance or cleaning of
the unit.
Cleaning the body
Use soft cloth to wipe the unit clean.
Don’t ever use volatile chemicals, gasoline,
detergents, chemically treated clothes, or other
cleaning solutions.These could all possibly
damage the casing.

SUN30
7
Cleaning the lter
Extract the lter from the unit.
Use a vacuum cleaner or tap the lter lightly for
easy cleaning.
If the lter is particularly dirty, use warm water
with mild detergent.
Make sure the lter is completely dry before
replacing.
Do not expose the lter to sunlight.
Cleaning of evaporator and condenser.
All maintenance must be performed by
qualied personnel.
Felsökning
Avfuktaren fungerar inte:
Är avfuktaren ansluten till ett eluttag?
Är omgivningstemperaturen under 8°C eller
över 32°C? Om så är fallet så är avfuktaren
utanför sitt arbetsområde.
Kontrollera att ON/OFF knappen är ON.
Kontrollera om uppsamlingskärlet är korrekt
placerat och att det inte är fullt.
Kontrollera att luftintaget och utsläppet inte är
blockerat.
Trouble shooting
The unit does not operate:
Is the unit plugged in?
Is the room temperature below 8°C or above
32°C? If so, then it is out of the working range
of the unit.
Ensure the ON/OFF switch is turned ON.
Check that the water tank is positioned properly
in the unit and that it is not full.
Make sure the air inlet and outlet are not
obstructed.
The unit produces little or no water:
Is the lter dusty, contaminated ?
Is the air intake or outlet blocked up?
Is the room humidity already quite low?
The unit does not dehimidify the air:
Are too many windows or doors open?
Is there something in the room producing lots
of humidity?
The unit is too noisy:
Check whether the unit is standing on an even
surface.
The unit is leaking:
Make sure the drain hole under the evaporator
isn´t clogged.
Make sure the condensate collecting container
isn´t broken.
If you are using continuous drainage, check
that the hose is installed correctly and that the
water drains away freely.

SUN30
8
Technical specication
Type SUN30
Operating humidity range % RH 30-100
Operating temp. range °C +8 - +32
Power supply V 220V - 240V~, 50 Hz
Fuse A 10
Max. power consumption W 500W / 2,2A
Dehumidication test condition at
20°C, 60% RH
liter / 24 h 13
Dehumidication test condition at
30°C, 80% RH
liter / 24 h 30
Refrigerant R290
Compressor Yes
Sound level* low/high speed dB (A) 47 / 51
Air ow rate low/high speed m3/h 200 / 280
Volume of water tank liter 6,2
Degree of protection IPX4
Net Weight kg 18,5
Size length mm 337
Size width mm 327
Size height mm 528
* Measured at a distance of 3 m from the unit.
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and collection systems or contact the
retailer where the product was purchased.

SUN30
9
Safety instructions for service
Please follow these warnings when to
undertake the following when servicing a
dehumidier with R290.
Checks to the area
Prior to beginning work on systems containing
ammable refrigerants, safety checks are
necessary to ensure that the risk of ignition
is minimized. For repair to the refrigerating
system, the following precautions shall be
complied with prior to conducting work on the
system.
Work procedure
Work shall be undertaken under a controlled
procedure so as to minimize the risk of a
ammable gas or vapor being present while the
work is being performed.
General work area
All maintenance staff and others working in
the local area shall be instructed on the nature
of work being carried out. Work in conned
spaces shall be avoided. The area around the
workspace shall be sectioned off. Ensure that
the conditions within the area have been made
safe by control of ammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate
refrigerant detector prior to and during work,
to ensure the technician is aware of potentially
ammable atmospheres. Ensure that the leak
detection equipment being used is suitable
for use with ammable refrigerants, i.e. no
sparking, adequately sealed or intrinsically safe.
Presence of re extinguisher
If any hot work is to be conducted on the
refrigeration equipment or any associated
parts, appropriate re extinguishing equipment
shall be available to hand. Have a dry powder or
CO² re extinguisher adjacent to the charging
area.
No ignition sources
No person carrying out work in relation to a
refrigeration system which involves exposing
any pipe work that contains or has contained
ammable refrigerant shall use any sources of
ignition in such a manner that it may lead to the
risk of re or explosion.
All possible ignition sources, including
cigarette smoking, should be kept suciently
far away from the site of installation, repairing,
removing and disposal, during which
ammable refrigerant can possibly be released
to the surrounding space. Prior to work taking
place, the area around the equipment is to
be surveyed to make sure that there are no
ammable hazards or ignition risks. “No
Smoking” signs shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is
adequately ventilated before breaking into the
system or conducting any hot work. A degree
of ventilation shall continue during the period
that the work is carried out. The ventilation
should safely disperse any released refrigerant
and preferably expel it externally into the
atmosphere.

SUN30
10
Säkerhetsföreskrifter vid service
Checks to the refrigeration equipment
Where electrical components are being
changed, they shall be t for the purpose
and to the correct specication. At all times
the manufacturer’s maintenance and service
guidelines shall be followed. If in doubt consult
the manufacturer’s technical department for
assistance.
The following checks shall be applied to
installations using ammable refrigerants:
The charge size is in accordance with the room
size within which the refrigerant containing
parts are installed;
The ventilation machinery and outlets are
operating adequately and are not obstructed;
If an indirect refrigerating circuit is being used,
the secondary circuit shall be checked for the
presence of refrigerant;
Marking to the equipment continues to be
visible and legible. Markings and signs that
are illegible shall be corrected; refrigeration
pipe or components are installed in a position
where they are unlikely to be exposed to any
substance which may corrode refrigerant
containing components, unless the components
are constructed of materials which are
inherently resistant to being corroded or are
suitably protected against being so corroded.
Checks to electrical devices
Repair and maintenance to electrical
components shall include initial safety checks
and component inspection procedures. If a
fault exists that could compromise safety, then
no electrical supply shall be connected to the
circuit until it is satisfactorily dealt with. If the
fault cannot be corrected immediately but it is
necessary to continue operation, an adequate
temporary solution shall be used. This shall be
reported to the owner of the equipment so all
parties are advised.
Initial safety checks shall include:
those capacitors are discharged: this shall
be done in a safe manner to avoid possibility
of sparking; that there no live electrical
components and wiring are exposed while
charging, recovering or purging the system;
that there is continuity of earth bonding.
Releasing refrigerant into atmosphere is
strictly forbidden!
Other manuals for Sunnan SUN30
1
Table of contents
Other Frico Dehumidifier manuals
Popular Dehumidifier manuals by other brands

Olimpia splendid
Olimpia splendid SECCASCIUTTO Instructions for installation, use and maintenance

Whirlpool
Whirlpool AD0402XM0 Use & care guide

EIP
EIP ECO85 owner's manual

BANDELIN
BANDELIN SONOREX TECHNIK UT16 operating manual

Motor Guard
Motor Guard MHT-7200 instructions

Frigidaire
Frigidaire LAD504DUL use & care