Replacement Parts
Model
Auto drain replacement parts no. Note 5) AD48
IDFA22E IDFA37E IDFA55E IDFA75E
Standard Specifications
Refrigerated
air dryer
Auto drain
JIS Symbol
Note 1) Air flow capacity under the standard condition (ANR)
[atmospheric pressure at 20°C, relative humidity at 65%]
Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32°C]
Note 3) Select air dryer according to the model selection method (page 2) for the models beyond the rated
specifications.
Note 4) Install a circuit breaker with a sensitivity of 30 mA.
Note 5) When a short-term interruption of the power supply (including momentary interruption) occurs in this
equipment, the restarting of normal operations may require some time or may be impossible due to the
operation of protective devices even after the supply of power returns.
Note 6) The part number for the auto drain components without including the body part.
Body part replacement is impossible.
Auto drain
Body
Construction (Air/Refrigerant Circuit)
IDFA22E, IDFA37E, IDFA55E, IDFA75E
Humid, hot air coming into
the air dryer will be cooled
down by a cooler re-heater
(heat exchanger). Water
condensed at this time will
be removed from the air by
auto drain and drained out
automatically. Air
separated from the water
will be heated by a cooler
re-heater (heat exchanger)
to obtain the dried air,
which goes through to the
outlet side.
Pressure switch
Compressed air inlet Compressed air outlet
Auto drain
Drain outlet
Accumulator
(IDFA22E, 37E, 55E only) Condenser Capillary tube
Cooler re-heater
Ball valve
Fan motor
High pressure switch
(IDFA55E, 75E only)
(Heat exchanger)
Compressor for refrigeration
Evaporation
thermometer
Volume control valve
Outlet air pressure dew point
Outlet air pressure dew point
Outlet air pressure dew point
Outlet air pressure dew point
Outlet air pressure dew point
Outlet air pressure dew point
(3°C)
(7°C)
(10°C)
(3°C)
(7°C)
(10°C)
Model
Specifications
760
4.3
1130
5.4
1700
7.9
20
Standard
condition
(ANR)
Com-
pressor
intake
condition
Note 1)
Note 2)
182
231
254
189
240
264
IDFA22E
10
273
347
382
284
361
397
IDFA37E
390
432
510
405
449
530
IDFA55E
660
720
822
686
748
854
IDFA75E
Body panel: White 1
Base: Gray 2
Standard temperature air inlet
0.7
35
25
Single-phase: 230 VAC [Voltage fluctuation ±10%] 50 Hz
Compressed air
5 to 50
0.15 to 1.0
2 to 40 (Relative humidity of 85% or less)
Inlet air pressure
Inlet air temperature
Ambient temperature
Power supply voltage
Power consumption
Operating current
Fluid
Inlet air temperature
Inlet air pressure
Ambient temperature (Humidity)
Applicable circuit breaker capacity Note 4)
Condenser
Refrigerant
Auto drain
Port size
Accessory
Weight
Coating colour
(MPa)
(°C)
(°C)
(W)
(A)
(A)
(kg)
(°C)
(MPa)
(°C)
Air-cooled
R407C (HFC)
—
54 62
R 1 R 11/2
100 116
R 2
Float type
(Normally open)
Air flow
capacity
m3/h
Operating range
Electric Rated specifications Note 3)
Series IDFA쏔E
7