EX. RINSE
103°
MOTOR
START
BLK/RED
RED
BLK/
HEATER
THERMOSTAT
2 K
CAUTION: DISCONNECT ELECTRIC CURRENT BEFORE SERVICING. LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
THERMOSTAT
CONTROL
GRAY
8
A
IN ALL MODELS.
CIRCUITS THAT ARE NOT
DASHED LINES INDICATE
NOTE:
DRYER TIMER
FABRIC SELECTOR
TAN
SWITCH
4
ORG
BLUE
1.5 K
5
1.5 K
1
120 VAC
BLK
H
B
BUZZER
WASHER TIMER
CIRCLED NUMBERS
INDICATE CAM
RED/BLK
BLK
L1
CONNECTOR
TO L1
14
12
T24
T21
T13
T10
WHT NO
NC
X
TM
TAN
S
C
MOTOR
TIMER
BRN
WHT
LEADS
TEST BRN
SWITCH
OPTION
SWITCH
DOOR
WHT
CONNECTOR
TO NEUTRAL
LIGHT
DRUM
GRAY
RED
BRN
WHT
WHT
C
N
M2
M6
M5
TAN/
WHT/PURP
6
2
MOTOR
TIMER
T14
T11
T15
T9
T6
4
0T7
T4
T5
T8
T1
T22
17
20
23
12
14
10
21
22
24
18
16
19
14
116
8
4 8
12
13
15
7
9
10
10
T18
BLK
T16
0°
WATER TEMP
AGITATE DIR
SPIN DIR
AGITATE DIR
HIGH SPEED MOTOR
SPIN CONTROL
AGIT CONTROL
SPIN DIR
LOW SPEED MOTOR
SPIN CONTROL
B
T
B
T
B
T
PUMP
B
T
B
T
B
T
CAPACITOR
TEMP SWITCH
FF
ORG
PURP
BLUE
BLUE
YELLOW
YELLOW
PINK
RED
WHT/RED
F
C
C
ORG
WATER
VALVE
MOTOR
PUMP
H
H
LID SWITCH
RED/WHT
27.5°
BLK
TAN/
42.5°
50°
PRESSURE
SWITCH
EMPTY
FULL
1
3
2
73°
2
1
95.5°
WASH
(15 MIN)
F
C
20
2 5
C
A
M
T
I
E
V
3
6
4
1
X
I
D
E
TERM
A
WASH FILL
FILL CONTROL
RINSE FILL
NOT USED
NCIRCUIT
B
B
T
T
T
T
A
C
O
C
(15 MIN)
REGULAR
PUMP
(6 MIN)
PA
(3)
RINSE
P P A
PUMP OFF
(3)
RINSE
P
BRANCH CIRCUIT.
5 MINUTES APART.
THEY WILL BE 5 MIN. APART.
CIRCUIT "X-H" WILL CLOSE FOR 5 SEC ±3 SEC 5 TO
7 TIMES IN THIS AREA. THE CLOSURES WILL BE
2 TIMES IN THIS AREA. WHEN 2 CLOSURES OCCUR
THE BAR CHART ABOVE REPRESENTS ONE
COMPLETE REVOLUTION OF TIMER SHAFT.
SHADED PORTION OF BAR CHART INDICATES
THE PROPORTIONAL TIMES THAT INTERNAL
TIMER CONTACTS ARE CLOSED.
CIRCUIT "X-H" WILL CLOSE FOR 5 SEC ±3 SEC 1 TO
A
TIMED DRY
SELECTOR SWITCH AT HIGH HEAT.
THERMOSTAT CLOSED. AND FABRIC
TEMPERATURE SELECTOR SWITCH AT
HOT WASH/COLD RINSE, AND
PRESSURE SWITCH FULL.
DOOR SWITCH CLOSED, MOTOR AT REST,
WASHER TIMER SHOWN IN ON POSITION
3. DRYER TIMER3. SHOWN IN OFF POSITION
SENSOR
ON THIS MODEL
NOT FUNCTIONAL
THIS HARNESS WIRE
THERMOSTAT
HIGH LIMIT
BLK
3
PURP
ORG ORG
ORG
4
IGNITER
WHT
COIL
SECONDARY
5
WHT
BOOSTER
WHT
3
COIL
WHT
1
AUTO DRY
58.75 MIN
LOW
MEDIUM/LOW
MEDIUM
HIGH
FUNCTION
SENSOR
CONTACT
CONTROL
TAN
SENSOR
MOISTURE
ELECTRONIC
TAN
P4
P5
P8
MOTOR
M4 RUN
START
M5
M6
P2
P1
RED
RED
2
M2
M1
GRAY
BASE
CABINET
GRN
SWITCH
START
B-S MOTOR
B-C MOTOR
B-A HEATER
CIRCUIT
X-H BUZZER
X-TM TIMER MOTOR
4B
3
1
1B
2
CAM
M1
M3
M7
LOW
HIGH
F
F
4
3
2
POSITION
1
O
GAS CONTROL VALVE
HOLDING COIL
YEL
BUZZER
EX
CARE
CYCLES
15 MIN
1.5K ±5%
OPEN CIRCUIT
F
A
A
B
B
F
RESISTANCE
O
10 MAX
3K±5%
F
F90 MIN
O
WIRING DIAGRAM
134217800 A
AIR FLUFF
22.5 MIN
A
286°
WARM/WARM (OPT)
TEMPERATURE SWITCH CIRCUIT
ELECTRICAL CODES.
1. ALL WIRING MUST CONFORM TO LOCAL
2. CONNECT DRYER TO 15 AMP INDIVIDUAL
CONNECTION
NO CONNECTION
MOTOR SWITCH
PLUG-IN TIMER TERMINAL
QUICK DISCONNECT TERMINAL
MOTOR PROTECTOR
CHASSIS (CABINET) GROUND
SCREW TERMINAL
HARNESS CONNECTOR TERMINAL
INSULATED TERMINAL
SPLICE
50 SEC MAX
DETAIL FOR FILL CONTROL SPRAY SUBINTERVAL
AND PAUSE FOR MOTOR/PUMP CONTROL CIRCUITS.
TIMER PLUG-MALE
(END VIEW)
18
17
16
23
22
20
19
24 21
14
13
11
10
15 12
8
7
5 2
4 1
9 36
FABRIC SELECTOR SWITCH
BLK
BLK/
RED
LID LOCK
CONNECTOR
TO DRYER L1
MOTOR/PUMP PAUSE = P
CONNECTION
NEUTRAL
TO DRYER
WHT
WHT
120°
142°
164.5°
SPRAY=A
179.5°
187°
12 SEC (REF)
WASH/RINSE
WARM/COLD
COLD/COLD
HOT/COLD
NOTES;
10 SEC (REF)
20±6 SEC
180 SEC
218.5°
197°
231.5°
264.5°
246.5°
254°
PUMP
(6 MIN)
(12 MIN)
(9 MIN)
PUMP
A
OFF PUMP
PERM. PRESS
(6 MIN)
WASH
PA(3)
RINSE
P P A
PUMP
(6 MIN)
KNITS & DELICATE
OFF
(6 MIN)
P
WASH
A
(3)
PP
RINSE
PUMP
(6 MIN)
A
OFF
X=CLOSED O=OPEN
FF-H
F-H
O
X
O
X
O
O
X
O
FF-C
X
X
O
X
WIRING CODES
293°
319.5°
327°
336°
360°
PREWASH
PUMP
(6 MIN)
SOAK
(12 MIN)
WASH
(3)
SOAK
WASH
(3)
OFF