Specifications
subject to change.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FGGF301DN 10/12 © 2012 Electrolux Home Products, Inc.
Freestanding Ranges
FGGF301DN F/ W/ B 30" Gas
Freestanding Range Specifications
•Product Shipping Weight (approx.) – 260 Lbs.
•Voltage Rating – 120V / 60 Hz / 15 Amp
•Connected Load (kW Rating) @ 120 Volts = 1.8 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•Amps @ 120 Volts = 15 Amps
•Always consult local and national electric and gas codes.
•Make sure wall coverings around range can withstand heat generated
by range.
•Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
•Do not install range beneath any downward-blowing, overhead vent
hood or air curtain.
•Range ships with 1/2" NPT factory regulator.
•LP Gas Conversion Kit supplied.
•Overhead cabinetry should not exceed a 13" maximum depth.
•Allow 30" minimum clearance between top of cooking surface and
bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/4" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
•Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
•Range can be installed flush to wall with 0" minimum rear clearance.
•Minimum 7" clearance required from edge of rangetop to nearest
combustible wall on either side of range above 36" height.
•To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
•Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
30" Gas Freestanding Ranges with Double Ovens (Upper)
Gallery