EN
4
NOTE: 1. Reserve enough length of fiber cable to be spliced.
2. Stripping length also could be decided by customers according to installation
requirement.
If all fibers are for branch splicing, please refer to 2(A) for stripping length. If some fibers are for
straight-through, while others are for branch splicing, please refer to 2(B) for stripping length.
Fiber cable
Temp.
locating mark
100mm sealing and fixing length of fiber cable inside inlet/outlet tube
150mm length of fiber with protective coat(the distance
from fixing point of fiber cable to fixing point of FOST)
100mm length of fiber with protective coat to be cut
1600mm length of protective coat of fiber to be
stripped off(branch splicing)
1850mm length of fiber cable
to be stripped off (for straight-through after being winded)
Temp.
locating mark
2(B)
Entry terminal fiber cable Stripping terminal fiber cable
Temp.
locating mark Cutter
Strip off Fiber Protective Coat of Fiber Cable
NOTE: If it is difficult to pull all the protective coat of fiber cable at one time, strip it off
section by section to avoid fiber breakage.
Strip off protective coat of fiber cable from the temp locating mark with the cutter and the stripper,
please refer above drawing for stripping length. Stripping length also could be decided according to
installation requirement.