REGULATORY COMPLIANCE
FSR'S ELECTRONIC PRODUCTS have been tested for compliance with: FCC Class A and CE The
Power Adapter has been tested for compliance with: UL, CSA and CE.
WARRANTY POLICY
This product is warranted against failures due to defective parts or faulty workmanship for a period of
one year after delivery to the original owner. During this period, FSR will make any necessary repairs or
replace the unit without charge for parts or labor. Shipping charges to the factory or repair station must
be prepaid by the owner, return-shipping charges, via UPS / FedEx ground, will be paid by FSR.
This warranty applies only to the original owner and is not transferable. In addition, it does not apply
to repairs done by other than the FSR factory or Authorized Repair Stations.
This warranty shall be cancelable by FSR at its sole discretion if the unit has been
subjected to physical abuse or has been modified in any way without written authorization from FSR.
FSR’s liability under this warranty is limited to repair or replacement of the defective unit.
FSR will not be responsible for incidental or consequential damages resulting from the use or misuse
of its products. Some states do not allow the exclusion of incidental or consequential damages, so the
above limitations may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
Warranty claims should be accompanied by a copy of the original purchase invoice
showing the purchase date (if a Warranty Registration Card was mailed in at the time of purchase, this
is not necessary). Before returning any equipment for repair, please read the important information
on service below.
SERVICE
Before returning any equipment for repair, please be sure that it is adequately packed and cushioned
against damage in shipment, and that it is insured. We suggest that you save the original packaging and
use it to ship the product for servicing. Also, please enclose a note giving your name, address, phone
number and a description of the problem.
NOTE: All equipment being returned for repair must have a Return Authorization (RMA)
Number. To get a RMA Number, please call:
FSR Service Department (973-785-4347).
Please display your RMA Number prominently on the front of all packages.
Contact Information:
FSR Inc.
244 Bergen Boulevard,
West Paterson, NJ 07424
Tel: (973) 785-4347 · Fax: (973) 785-4207
E-Mail: [email protected] · Web: http://www.fsrinc.com
TWISTER 2
DATA /IR TWISTED PAIR
TRANSMITTER T2-DTXW
RECEIVER T2-DRX
OPERATION MANUAL
LIT1214A
FSR
43919
PROPRIETARY INFORMATION
All information in this manual is proprietary to and the
property of FSR inc. This publication is protected by the Federal
Copyright Law, with all rights reserved. No part of this document
may be reproduced, transcribed, or transmitted, in any form or by
any means, without prior explicit written permission from FSR
Inc.
Operators Safety Summary
The general safety information in this summary is for operating
personnel.
Read Instructions Read and understand all safety and operating
instructions before using this equipment. Keep the instructions
handy.
Do Not Remove Covers or Panels There are no user-serviceable
parts within the unit. Removal of the top cover will expose
dangerous voltages. To avoid personal injury, do not remove the
top cover. Do not operate the unit without the cover installed.
Power Source This product is intended to operate from the
specified wall plug-in transformer. Do not use any other power
source.
Grounding the Product This product is grounded through the
grounding conductor of the power cord. To avoid electrical shock,
plug the power cord into a properly wired receptacle before
connecting to the product input or output terminals.
Use the Proper Power Cord Use only the power cord and
connector specified for your product. Use only a power cord that is
in good condition. Refer cord and connector changes to qualified
service personnel.
Do Not Operate in Explosive Atmospheres To avoid explosion,
do not operate this product in an explosive atmosphere.
TECHNICAL SPECIFICATIONS
RS-232 DATA INPUT
Number/Type: 1- DB-9 female connector. DCE type connection for direct
connection to a PC serial port.
Handshaking: Local loop back only
RS-232 type Bidirectional, full duplex
RS-232 DATA OUTPUT
Number/Type: 1- DB-9 male connector. DTE type connection for direct
connection to peripheral.
Data Rate: 0-115k baud
INFRARED INPUT
Number/Type: 1- 3.5 mm mini jack center positive
Compatibility Compatible with most IR outputs designed to drive an IR
emitter LED.
INFRARED OUTPUT
Number/Type: Dual output on 3 pin pluggable Phoenix connector for
connection to multiple IR emitters.
Output Switch 2 position dip switch (Normal 12 mW/High 60mW)
Carrier Range 0-200 kHz
POWER T2-DTXW and T2-DRX: 9 VA[email protected] or [email protected].
Power supplies are provided
MECHANICAL
Transmitter enclosure Metal 1.70”W x0.93”D x4.09”H
Shipping weight 1 lbs.
Receiver enclosure Metal 4.22”W x3.93”D x1.59”H
Shipping weight 1.2 lbs.
GENERAL
UTP cable wiring standard
/ type EIA / TIA-568B CAT5, 5E, 6
Recommended transmission
range 0-1000 ft
ACCESORIES 1 rack unit mounting kit to fit a standard 19” rack FSR part
number 16214
RJ-45 JACK FRONT VIEW
1 W/Orange
2 Orange
3 W/Green
4 Blue
5 W/Blue
6 Green
7 W/Brown
8 Brown
EIA/TIA568B
Wiring Standard
T2-DTXW TRANSMITTER
DB-9 FEMALE
PIN SIGNAL DIRECTION
1 DCD TIES TO PINS 4 AND 6
2 RXD OUTPUT
3 TXD INPUT
4 DTR TIES TO PINS 1 AND 6
5 GND -
6 DSR TIES TO PINS 1 AND 4
7 RTS TIES TO PIN 8
8 CTS TIES TO PIN 7
9RI NC
T2-DRX RECEIVER
DB-9 MALE
PIN SIGNAL DIRECTION
1 DCD TIES TO PINS 4 AND 6
2 RXD INPUT
3 TXD OUTPUT
4 DTR TIES TO PINS 1 AND 6
5 GND -
6 DSR TIES TO PINS 1AND 4
7 RTS TIES TO PIN 8
8 CTS TIES TO PIN 7
9RI NC
RS-232 PIN ASSIGNMENTS
INTRODUCTION
The all new TWISTER 2 SERIES, which is comprised of a T2-DTXW
DATA/IR TRANSMITTER and a T2-DRX DATA/IR RECEIVER is
designed for applications requiring the transport of RS-232 data and/or
IR control data over long distances on UTP (Cat 5, 5E, 6) type cable.
Cable runs of over 1000 feet are within the capabilities of the product.
These high quality devices ensure reliable, error free data transmission
that is immune to interference from electrical noise.
FEATURES
RS-232 Data Transmission
• DB-9 female connectors for the inputs and male for outputs
• UTP connections are via RJ-45 Connectors (EIA/TIA-568B)
• Compatible with RS-232 standards
• UL and CSA approved external power source (wall plug-in)
• Full duplex RS-232 up to 115K baud
• Serial TXD/RXD signal confirmation Indicators
IR Control Data Transmission
• Compatible with most IR devices
• Extends IR control up to 1000 feet
• Normal and high output emitter power level settings
• Dual output terminals for convenient hookup of multiple emitters
• IR receiver signal confirmation indicator
APPLICATIONS
• Boardrooms • Houses of Worship• Control Rooms
• Classrooms• Staging and Rental
ACCESSORIES
• Under table tab mounting kit FSR part number15982
1 rack unit mounting kit to fit a standard 19” rack FSR part number
16214
Installation and Operation
Mount the units as appropriate for the particular installation.
There are tapped holes on the top and bottom of the T2-DRX for mount-
ing. Use screws that protrude through no longer than 1/2".
The T2-DTXW resembles standard duplex outlet shape and will mount
into a standard gang box. Connect the RJ-45 jack and power supply
leads BEFORE mounting the unit in the gang box. Always check for
cable clearance while mounting.
The input power connector is NOT polarity sensitive and should be con-
nected to the provided supply to both the transmitter and receiver. Do
not plug in the supplies until all cables are tested.
UTP Installation
Install and terminate the UTP cable, taking note of the following. The
cable must be terminated using the EIA/TIA-568B standard pairing.
Where possible, the use of pre terminated, pretested cables is highly
recommended. If field termination is required, be sure to use a commer-
cially available cable tester to confirm the proper wiring.
While Cat 5/5E cables are the most commonly used with the system
other types of UTP cable can be used successfully.
RS-232 Installation
Connect the RS-232 output of the PC or control system to the T2-DTXW
transmitter module "SERIAL IN" DB-9 female port. Connect the periph-
eral to the T2-DRX "SERIAL OUT" DB-9 male port. (See pinout)
IR Control Installation
Confirm and observe polarity on all external devices before proceed-
ing.
Connect the IR output device to the 3.5mm jack on the face of the T2-
DTXW Transmitter.
Connect the IR emitter(s) to the pluggable phoenix connector on the T2-
DRX Receiver using the wiring diagram provided. Emitters are available
from FSR. Use FSR part number 28397.
Once the interconnect cables are tested, Plug in both power supplies and
perform a final operation check.
TYPICALAPPLICATION
MECHANICAL DIMENSIONS
1.70
4.09
.93
.27
2.72
IR IN
IR IN POWER
SERIAL IN
T2-DTXW
UTP
OUTPU
OUTPUT
TO TWISTER 2
RECEIVER
12VDC/0.1A
9VAC/0.2A
POWER
244 Bergen Blvd.
West Paterson, NJ
07424
1 2
3.93
3.69
4.22
1.59
2
IR
RxD
Serial Normal
1
T2-DRX
TxD
Power
IR Power
High
Data/IR Receiver
Power
9VAC/0.2A
UTP Input
from Twister 2
Transmitter
Data/IR Receiver
2
IR Out
1
Gnd
Serial Out
12VAC/0.1A
1 2
2
IR
RxD
Serial Normal
1
T2-DRX
TxD
Power
IR Power
High
Data/IR Receiver
Power
9VAC/0.2A
UTP Input
from Twister 2
Transmitter
Data/IR Receiver
2
IR Out
1
Gnd
Serial Out
12VAC/0.1A
IR IN POWER
SERIAL IN
T2-DTXW
UTP OUTPUT
TO TWISTER 2
RECEIVER
12VDC/0.1A
9VAC/0.2A
POWER
244 Bergen Blvd.
West Paterson, NJ
07424
RN-1000/RN-8200
OR CONTROL
SYSTEM
RS-232
T2-DTXW
FRONT T2-DTXW
BACK
RJ-45
TWISTED PAIR
UP T
O 1000'
O 1000'
T2-DRX
BACK
T2-DRX
FRONT
RS-232
CONTROLLED
DEVICE
IR EMITTERS
OPTIONAL
FSR #28397 (2x)
IR CONTROLLED
DEVICE
TO AC
POWER
TO AC
POWER
PROJECTOR
PROJECTOR

This manual suits for next models

2

Other FSR Receiver manuals

FSR HD-HU-SP-TX User manual

FSR

FSR HD-HU-SP-TX User manual

FSR HD-HSC-SP-RX User manual

FSR

FSR HD-HSC-SP-RX User manual

FSR RN-WPCS User manual

FSR

FSR RN-WPCS User manual

FSR T2-CATXW User manual

FSR

FSR T2-CATXW User manual

FSR HD-HAUD-SP-RX User manual

FSR

FSR HD-HAUD-SP-RX User manual

Popular Receiver manuals by other brands

Onkyo TXNR905 - AV Network Receiver Quick setup

Onkyo

Onkyo TXNR905 - AV Network Receiver Quick setup

EchoStar DSB-1200 Viaccess user manual

EchoStar

EchoStar DSB-1200 Viaccess user manual

RCA DRD403RA owner's manual

RCA

RCA DRD403RA owner's manual

Fortec Star FS-4300 Technical specifications

Fortec Star

Fortec Star FS-4300 Technical specifications

CHCNAV i89 GNSS user guide

CHCNAV

CHCNAV i89 GNSS user guide

Denon AVR-1713 owner's manual

Denon

Denon AVR-1713 owner's manual

Alinco DR-135 Service manual

Alinco

Alinco DR-135 Service manual

LG LH-T7652SB Service manual

LG

LG LH-T7652SB Service manual

Lectronics Venue 2 VRM2WBL installation guide

Lectronics

Lectronics Venue 2 VRM2WBL installation guide

DTM System GALACTIC NANO 868 installation manual

DTM System

DTM System GALACTIC NANO 868 installation manual

SuperMax AC 9200 Power Plus user guide

SuperMax

SuperMax AC 9200 Power Plus user guide

CHC P3E Getting started guide

CHC

CHC P3E Getting started guide

Fuba ODE8500 T2HEVC user manual

Fuba

Fuba ODE8500 T2HEVC user manual

Pioneer FH-M8527ZT-91 ES Service manual

Pioneer

Pioneer FH-M8527ZT-91 ES Service manual

Spectra Precision SP90m manual

Spectra Precision

Spectra Precision SP90m manual

DMX RadioGate Plus user manual

DMX

DMX RadioGate Plus user manual

GeoMax Zenith35 Pro Series quick guide

GeoMax

GeoMax Zenith35 Pro Series quick guide

Yamaha RX-V365 owner's manual

Yamaha

Yamaha RX-V365 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.