Operators Safety Summary
The general safety information in this summary is for operating
personnel.
Read Instructions Read and understand all safety and operating
instructions before using this equipment. Keep the instructions
handy.
Do Not Remove Covers or Panels There are no user-serviceable
parts within the unit. Removal of the top cover will expose
dangerous voltages. To avoid personal injury, do not remove the
top cover. Do not operate the unit without the cover installed.
Power Source This product is intended to operate from the
specified wall plug-in transformer. Do not use any other power
source.
Grounding the Product This product is grounded through the
grounding conductor of the power cord. To avoid electrical shock,
plug the power cord into a properly wired receptacle before
connecting to the product input or output terminals.
Use the Proper Power Cord Use only the power cord and
connector specified for your product. Use only a power cord that is
in good condition. Refer cord and connector changes to qualified
service personnel.
Do Not Operate in Explosive Atmospheres To avoid explosion,
do not operate this product in an explosive atmosphere.
TECHNICAL SPECIFICATIONS
RS-232 DATA INPUT
Number/Type: 1- DB-9 female connector. DCE type connection for direct
connection to a PC serial port.
Handshaking: Local loop back only
RS-232 type Bidirectional, full duplex
RS-232 DATA OUTPUT
Number/Type: 1- DB-9 male connector. DTE type connection for direct
connection to peripheral.
Data Rate: 0-115k baud
INFRARED INPUT
Number/Type: 1- 3.5 mm mini jack center positive
Compatibility Compatible with most IR outputs designed to drive an IR
emitter LED.
INFRARED OUTPUT
Number/Type: Dual output on 3 pin pluggable Phoenix connector for
connection to multiple IR emitters.
Output Switch 2 position dip switch (Normal 12 mW/High 60mW)
Carrier Range 0-200 kHz
Power supplies are provided
MECHANICAL
Transmitter enclosure Metal 1.70”W x0.93”D x4.09”H
Shipping weight 1 lbs.
Receiver enclosure Metal 4.22”W x3.93”D x1.59”H
Shipping weight 1.2 lbs.
GENERAL
UTP cable wiring standard
/ type EIA / TIA-568B CAT5, 5E, 6
Recommended transmission
range 0-1000 ft
ACCESORIES 1 rack unit mounting kit to fit a standard 19” rack FSR part