1-4. Product information
Model name
Hydraulic indoor unit WSYG160DJ6 WSYK170DJ9
Outdoor unit WOYG160LJL WOYK150LJL WOYK170LJL
Air-to-water heat pump Yes
Water-to-water heat pump No
Brine-to-water heat pump No
Low-temperature heat pump No
Equipped with a supplementary heater Yes
Heat pump combination heater No*1
Temperature application °C 55 35 55 35 55 35
Rated heat output*2Prated kW 14 16 16 17 17 18
Seasonal space heating energy efficiency ƞs % 125 163 130 164 130 161
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj = –7°C Pdh kW 12.0 14.2 14.2 15.4 15.0 16.0
Tj = +2°C Pdh kW 7.3 8.7 8.6 9.4 9.0 9.7
Tj = +7°C Pdh kW 6.3 7.0 6.4 6.7 6.3 6.8
Tj = +12°C Pdh kW 7.6 8.1 7.6 8.0 7.7 8.0
Tj = bivalent temperature Pdh kW 12.0 14.2 14.2 15.4 15.0 16.0
Tj = operation limit temperature Pdh kW 10.6 14.1 13.3 14.7 12.4 14.8
Tj = –15°C (if TOL < –20°C) Pdh kW — — — — — —
Bivalent temperature Tbiv °C -7 -7 -7 -7 -7 -7
Cycling interval capacity for heating Pcych kW Not applicable
Degradation co-efficient*3Cdh 0.9 0.9 0.9 0.9 0.9 0.9
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj
Tj = –7°C COPd1.98 2.79 2.12 2.90 2.10 2.82
Tj = +2°C COPd3.15 4.17 3.30 4.19 3.32 4.13
Tj = +7°C COPd4.30 5.34 4.21 5.13 4.23 5.01
Tj = +12°C COPd5.99 6.76 6.02 6.83 5.95 6.64
Tj = bivalent temperature COPd1.98 2.79 2.12 2.90 2.10 2.82
Tj = operation limit temperature COPd1.75 2.54 1.88 2.62 1.76 2.61
Tj = –15°C (if TOL < –20°C) COPd— — — — — —
Operation limit temperature TOL °C -10 -10 -10 -10 -10 -10
Cycling interval efficiency COPcyc Not applicable
Heating water operating limit temperature WTOL °C 60 60 60 60 60 60
Power consumption in modes other than active mode
Off mode POFF kW 0.019 0.019 0.016 0.016 0.016 0.016
Thermostat-off mode PTO kW 0.046 0.100 0.043 0.096 0.046 0.097
Standby mode PSB kW 0.023 0.023 0.019 0.019 0.019 0.019
Crankcase heater mode PCK kW 0.000 0.000 0.000 0.000 0.000 0.000
Supplementary heater
Rated heat output*2PSUP kW 3.0 2.0 2.7 2.7 4.1 3.1
Type of energy input Electric
Other items
Capacity control Variable
Sound power level Indoor unit LWA dB 45 45 45 45 45 45
Outdoor unit LWA dB 67 66 67 66 67 68
Annual energy consumption QHE kWh 8,757 80,14 9,915 8,606 10,232 9,059
Emissions of nitrogen oxides NOxmg/kWh Not applicable
Rated airflow rate Outdoor unit m3/h 6,250 6,250 6,250 6,250 6,250 6,250
Declared load profile — — — — — —
Daily electricity consumption Qelec kWh — — — — — —
Annual energy consumption AEC kWh — — — — — —
Water heating energy efficiency ηwh % — — — — — —
Daily fuel consumption Qfuel kWh Not applicable
Contact details FUJITSU GENERAL (EURO) GmbH
Fritz-Vomfelde-Straße 26-32, 40547 Düsseldorf, Germany
NOTES:
• Product information according to Commission Delegated Regulation (EU) 811/2013
• Product information is based on the average climate condition.
• *1: When using an optional component, this function is available.
• *2: For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supple-
mentary heater Psup is equal to the supplementary capacity for heating sup (Tj).
• *3: If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
1-4. Product information - (01-3) - 1. Specifications
OUTDOOR
UNIT
OUTDOOR
UNIT