CARE OF YOUR FUJITSU DRIVE
Careful handling and installation of your disk drive is paramount to the longevity of the unit. Serious damage can occur to the internal
mechanisms if forces outside the environmental specifications are exerted to the casing. In transportation, always use the original packing in
which the drive was supplied and avoid sharp changes in temperature to minimise the risk of condensation.
INSTALLATION
1. ORIENTATION–The drive can be installed in each six surface down orientations. Inclination from vertical or horizontal should not
exceed 5°.
2. MOUNTING SCREW INSTALLATION–When the mounting screw holes on the side of the drive are used, be sure to use the two pairs
of outer holes. Do not use the center hole in conjunction with onl one of the outer holes. The screws must not penetrate the drive b more
than 6.35 millimeters. Impact caused b the electric driver must be within the device specifications.
3. COOLING–Allow space above and below the drive to provide an adequate air flow. Fan cooling is recommended. The disk enclosure
temperature measured at center of base cover (Label side), should never exceed 55°C.
Reference value:
MAN series... An air flow with a velocit of more than 0.1 m/s is required in an environment of 30°C. (Center of DE cover ≤ 55°C)
(at 200 IOPS) An air flow with a velocit of more than 0.3 m/s is required in an environment of 35°C. (Center of DE cover ≤ 55°C)
An air flow with a velocit of more than 0.5 m/s is required in an environment of 40°C. (Center of DE cover ≤ 55°C)
An air flow with a velocit of more than 1.0 m/s is required in an environment of 45°C. (Center of DE cover ≤ 55°C)
MAM series... An air flow with a velocit of more than 0.6 m/s is required in an environment of 30°C. (Center of DE cover ≤ 55°C)
(at 250 IOPS) An air flow with a velocit of more than 0.9 m/s is required in an environment of 35°C. (Center of DE cover ≤ 55°C)
An air flow with a velocit of more than 1.3 m/s is required in an environment of 40°C. (Center of DE cover ≤ 55°C)
An air flow with a velocit of more than 1.9 m/s is required in an environment of 45°C. (Center of DE cover ≤ 55°C)
4. TERMINATION–A terminating resistor should be installed externall at both ends of the SCSI bus.
5. TERMINATION POWER–TRMPWR must be supplied to the terminating resistor for correct operation. This can be supplied from
either the drive, except for MC model or the SCSI bus. If onl MC model drives are connected to the SCCI bus, TRMPWR should be
supplied externall .
6. ATTACHING THE CABLES–To avoid possible damage to the drive, make sure the direction of the connector matches.
CAUTION: Warrant ma be avoided if damage to the connector is caused b wrong insertion.
Handl ng
1. Never drop. Handle with care.
2. Never move the disk drive while the disks are spinning. This is when the drive is powered on and also immediatel after power off. Refer
to the Start/Stop specification for our drive.
3. Always turn off the power before connecting or disconnecting the interface cable. The same applies to changing an of the switches or
terminal settings except if the Write protect switch is present on MP model drives.
4. Never place the drive in the vicinit of strong magnetic fields such as monitors, televisions, or loudspeakers.
5. Never use an cleaning agents or liquids on the drive.
6. Always use an antistatic mat and wrist strap when handling the drive. Hold the drive b the Base casting and never touch the components
on the PCA.
7. Never remove an labels from the drive and do not deface them in an wa ; these labels are part of the disk drive design.
8. Never open the disk enclosure for an reason. There are no serviceable parts inside. This will also invalidate an warrant .
9. Always pa close attention to the mounting specifications such as swa space and cooling. If the temperature difference between storage
location and installation locations is more than 10°C, leave the drive in the new location for at least two hours for Temperature acclimation.
This minimises an risk of condensation forming on the drive.
The Dr ve needs NO preventat ve or per od c ma ntenance dur ng ts l fe t me f properly used n the correct env ronment.
MAN3735, MAN3367, MAN3184 SERIES
MAM3367, MAM3184 SERIES
DISK DRIVES INSTALLATION GUIDE
FUJITSU LIMITED
Storage Products Group
4-1-1 Kamikodanaka, Nakahara-ku, Kawasaki 211-8588, Kanagawa-ken, Japan
Copyright © 2001 FUJITSU LIMITED
J
APAN http://www.jp.fujitsu.com/
USA http://www.fcpa.com/
EUROPE http://www.fujitsu-europe.com/
C141-E127-03EN
All manuals and user guides at all-guides.com
all-guides.com

Diagram and user-selectable options
Below is a diagram of the main board of SCSI disk drives and also a summary of the user-selectable options including guidelines for
installation of the drives.
This setting applies only for MP model drives and does not apply for MC model drives.
CN2
Pin1 (Disk enclosure) side
C
N2
Pin1 (Disk enclosure side)
MAN series (MP models) MAM series (MP models)
CN2 Terminal Setting (on MP models only)
Pin # Setting Item Function
1-2 SCSI ID 0 See “SCSI ID Setting on CN2 (on MP models only)” Table
3-4 SCSI ID 1
5-6 SCSI ID 2
7-8 SCSI ID 3
9-10 Write protect Open ……Write operation is enabled. (default)
Short ……Write operation is disabled.
11-12 Motor start mode Open ……Starting of motor is controlled with START/STOP
UNIT command.
Short ……Motor is started immediately after power supply is
turned on or microcode is downloaded. (default)
13-14 Force Narrow Open ……16-bit bus mode (default)
Short ……Pull upper 8bits and parity internally when drive is
connected to Narrow SCSI bus.
15-16 Force Single Ended Open ……Follows DIFFSNS signal level on SCSI bus. (default)
Short ……Single-Ended mode
17 GND
18, 19 N.C
20 IDD Reset Input signal
21-22 Remote LED Output signal
23-24 Terminal power supply Open ……Drive does not supply terminator power to SCSI bus.
Short ……Drive supplies terminator power to SCSI bus. (default)
SCSI ID Setting on CN2 (on MP models only)
Pin 1-2 Pin 3-4 Pin 5-6 Pin 7-8 ID Pin 1-2 Pin 3-4 Pin 5-6 Pin 7-8 ID
Open Open Open Open 0 Open Open Open Short 8
Short Open Open Open 1 Short Open Open Short 9
Open Short Open Open 2 Open Short Open Short 10
Short Short Open Open 3 Short Short Open Short 11
Open Open Short Open 4 Open Open Short Short 12
Short Open Short Open 5 Short Open Short Short 13
Open Short Short Open 6 Open Short Short Short 14
Short Short Short Open 7 Short Short Short Short 15 (default)
All manuals and user guides at all-guides.com
Other manuals for MAN3735 SERIES
1
This manual suits for next models
4
Table of contents
Other Fujitsu DC Drive manuals
Popular DC Drive manuals by other brands

Idex
Idex MICROPUMP EAGLEDRIVE EMSN Series Installation, operation and warranty information

sauter
sauter AVM Series instructions

Iomega
Iomega REV 70 Quick install

Montech
Montech 508815 Assembly instructions

EMG
EMG DELTA VFD-MS300 Series Quick setup instructions

Becker
Becker Extended Features XR7/85 Assembly and operating instructions