REMOTE USER INTERFACE FOR
MICROSOL II PLUS
WALLLINK01-01T-11868
5.FUNCTIONMENU
The function menu allows configuring Microsol II plus controller functions remotely. To access the
functionmenupress and keyssimultaneouslyfortwosecondsuntilthefunctionsareshown
in the display. To access any function and confirm the value press ; to go back to the previous
menuortoleaveanyfunctionwithoutconfirmingpress .Thefollowingoptionsareavailableinthe
functionmenu:
1.DESCRIPTION
2.APPLICATION
3.TECHNICAL SPECIFICATIONS
4.MAIN SCREEN
Wall-Link
Wall-Link
is an interface intended to be used together with Microsol II plus from version 2 and
above.
ItenableseasyandquickremoteaccesstoallMicrosolIIplusinformationandsetup.
Solarheatingcontrolling.
-Powersupply:90-264Vac(50/60Hz)
-Size:90x131x28mm(WxHxD)
-Operatingtemperature:0to50°C
-Operatinghumidity:10to90%RH(nocondensation)
-Datacommunication:bywire-maximumdistanceof1000meters
Thefigurebelowshowsthemainscreenof withthesysteminoperation.
01-Access Code
02-Functions
03-Schedule Mode
04-Schedule Evt
05-Clock
Preferential indication
description
Preferential indication
value
Swimming pool
26.9$C
5.1Access code
5.2Functions
5.3Eventschedulingmode
5.4Eventscheduling
5.5Clockadjustment
6.QUICK ACCESSMENU
Theaccess code 123 mustbe entered in thisscreen to enable changingfunctions of Microsol II plus
controller. Toenterthecodepress onthemessageandadjustthevaluethatwillbeblinkingonthe
display. Press againtoconfirm;tocancelandgobackpress .
In this screen all functions of Microsol II plus can be adjusted. To make changes press on the
desiredfunctionandenterthevaluethatwillbeblinkingonthedisplay.Press againtoconfirmthe
newvalue;tocancelandgobackpress .
TheoperatingmodeofMicrosolIIpluseventschedulingcanbeprogrammedfromthisscreen.
Thescheduleoftheremoteinstrumentcanbeviewedandchangedbyaccessingthisfunctionwiththe
key . Toinformorchange theconfigurationpress ontheoptioncorrespondingtotheevent
anddayofthe week. Adjust the time ofbeginningandendofthe event using the and keys,
press toconfirmthenewvalue;tocancelandgobackpress .
Togobackortoleavetheoptionspress atanytime.
To adjust the internal clock of Microsol II plus select this function by pressing . Then adjust the
valuesusingthe and andpress toconfirmor tocancel.
Togobackortoleavetheoptionspress atanytime.
The quick access menu allows configuring the setpoints of supports 1 and 2, as well as the manual
operatingmodesandtheoverheatingtemperatureforsensor1.Toaccessthismenu,press shortly
while mainscreenisdisplayed.Toaccessanyfunctionandconfirmthevaluepress ;toWall-Link
Function
description
Function code Function value
On Dif Temp
dOn@ 10.0 #
Function unit
Monday
E02@ 09:40/18:50
Day of week
Day event Start time Finish time
backtothepreviousmenuortoleaveanyfunctionwithoutconfirmingpress .
Thefollowingoptionsareavailableinthefunctionmenu:
Thisfunctionallowsadjustingthecontroltemperatureforauxiliaryoutput1.
Thisfunctionallowsadjustingthecontroltemperatureforauxiliaryoutput2.
This function allows adjusting the overheating temperature for sensor 2. When applied to swimming
poolsthisisthelimittemperatureofthewater(comforttemperature)
Thisfunctionallowsadjustingthemanualoperatingmodeofthewaterpump.
The operating mode of the auxiliary 1 output can be toggled between manual and automatic by
pressing onthisfunction.
The operating mode of the auxiliary 2 output can be toggled between manual and automatic by
pressing on this function. Note: This option will be only available when the Microsol II plus is
version03.
Uponaccessing the quick access menu while isnotconnected to Microsol II plus, theuser
willhavetwofunctionsavailableforadjustingtheaddressof MicrosolIIplus:
TheaddressofMicrosolIIpluscontrollercanbemanuallyadjustedbyenteringthisfunction.Thevalue
ofthisfunctionmustbethesamevalueconfiguredinMicrosolIIplus.
6.1 Auxiliary1 setpoint
6.2 Auxiliary2 setpoint
6.3Sensor 2 overheatingtemperature
6.4Waterpumpoperatingmode
6.5Auxiliary 1 manualmode enable
6.6Auxiliary 2 manualmode enable
7.ACCESSMENUFOR ADJUSTINGTHECONNECTION
7.1 Microsol II plusaddress
Wall-Link
03-S2 Hi Temp 05-A1 Man Mode
04-Pmp Activat
01-McSol 485 Add
02-Search McSol
06-A2 Man Mode
Only with Microsol II plus from version 03
01-Setpoint A1
02-Setpoint A2
7.2Search Microsol IIplus
8.SETUP MENU
8.1McSol2 485 Add
8.2Interface
Pressing on this function makes start searching for Microsol II plus address
automatically.Enterthequickaccessmenuagaintostoptheautomaticsearch.
The operating characteristics of can be adjusted through the setup menu. To access the
functionmenupress and keyssimultaneouslyforeightsecondsuntilthefunctionsareshown
inthedisplay.Thefollowingoptionsareavailableinthesetupmenu:
ThisfunctionallowstomanuallyadjustingtheaddressoftheMicrosolIIpluscontroller.
ThevaluesetforthisfunctionshouldbethesamevaluesetontheMicrosolIIplus.
Allowsadjustingtheuserinterfacecharacteristics:
Wall-Link
Wall-Link
01-McSol 485 Add 04-Timeouts
02-Interface
03-Descriptions
05-Statistics
Descrição Mín. Máx. Unid
Fun Padrão
S1
-
1
0
Off
All
-
10
999
On
-
-
-
min.
-
Indication
Language
Display contrast
Display timeout
Sound signaling
S2
Port
5
0
Off
I01
I02
I03
I04
I05