Full Gauge Wall-Link User manual

REMOTE USER INTERFACE FOR
MICROSOL II PLUS
WALLLINK01-01T-11868
5.FUNCTIONMENU
The function menu allows configuring Microsol II plus controller functions remotely. To access the
functionmenupress and keyssimultaneouslyfortwosecondsuntilthefunctionsareshown
in the display. To access any function and confirm the value press ; to go back to the previous
menuortoleaveanyfunctionwithoutconfirmingpress .Thefollowingoptionsareavailableinthe
functionmenu:
1.DESCRIPTION
2.APPLICATION
3.TECHNICAL SPECIFICATIONS
4.MAIN SCREEN
Wall-Link
Wall-Link
is an interface intended to be used together with Microsol II plus from version 2 and
above.
ItenableseasyandquickremoteaccesstoallMicrosolIIplusinformationandsetup.
Solarheatingcontrolling.
-Powersupply:90-264Vac(50/60Hz)
-Size:90x131x28mm(WxHxD)
-Operatingtemperature:0to50°C
-Operatinghumidity:10to90%RH(nocondensation)
-Datacommunication:bywire-maximumdistanceof1000meters
Thefigurebelowshowsthemainscreenof withthesysteminoperation.
01-Access Code
02-Functions
03-Schedule Mode
04-Schedule Evt
05-Clock
Preferential indication
description
Preferential indication
value
Swimming pool
26.9$C
5.1Access code
5.2Functions
5.3Eventschedulingmode
5.4Eventscheduling
5.5Clockadjustment
6.QUICK ACCESSMENU
Theaccess code 123 mustbe entered in thisscreen to enable changingfunctions of Microsol II plus
controller. Toenterthecodepress onthemessageandadjustthevaluethatwillbeblinkingonthe
display. Press againtoconfirm;tocancelandgobackpress .
In this screen all functions of Microsol II plus can be adjusted. To make changes press on the
desiredfunctionandenterthevaluethatwillbeblinkingonthedisplay.Press againtoconfirmthe
newvalue;tocancelandgobackpress .
TheoperatingmodeofMicrosolIIpluseventschedulingcanbeprogrammedfromthisscreen.
Thescheduleoftheremoteinstrumentcanbeviewedandchangedbyaccessingthisfunctionwiththe
key . Toinformorchange theconfigurationpress ontheoptioncorrespondingtotheevent
anddayofthe week. Adjust the time ofbeginningandendofthe event using the and keys,
press toconfirmthenewvalue;tocancelandgobackpress .
Togobackortoleavetheoptionspress atanytime.
To adjust the internal clock of Microsol II plus select this function by pressing . Then adjust the
valuesusingthe and andpress toconfirmor tocancel.
Togobackortoleavetheoptionspress atanytime.
The quick access menu allows configuring the setpoints of supports 1 and 2, as well as the manual
operatingmodesandtheoverheatingtemperatureforsensor1.Toaccessthismenu,press shortly
while mainscreenisdisplayed.Toaccessanyfunctionandconfirmthevaluepress ;toWall-Link
Function
description
Function code Function value
On Dif Temp
dOn@ 10.0 #
Function unit
Monday
E02@ 09:40/18:50
Day of week
Day event Start time Finish time
backtothepreviousmenuortoleaveanyfunctionwithoutconfirmingpress .
Thefollowingoptionsareavailableinthefunctionmenu:
Thisfunctionallowsadjustingthecontroltemperatureforauxiliaryoutput1.
Thisfunctionallowsadjustingthecontroltemperatureforauxiliaryoutput2.
This function allows adjusting the overheating temperature for sensor 2. When applied to swimming
poolsthisisthelimittemperatureofthewater(comforttemperature)
Thisfunctionallowsadjustingthemanualoperatingmodeofthewaterpump.
The operating mode of the auxiliary 1 output can be toggled between manual and automatic by
pressing onthisfunction.
The operating mode of the auxiliary 2 output can be toggled between manual and automatic by
pressing on this function. Note: This option will be only available when the Microsol II plus is
version03.
Uponaccessing the quick access menu while isnotconnected to Microsol II plus, theuser
willhavetwofunctionsavailableforadjustingtheaddressof MicrosolIIplus:
TheaddressofMicrosolIIpluscontrollercanbemanuallyadjustedbyenteringthisfunction.Thevalue
ofthisfunctionmustbethesamevalueconfiguredinMicrosolIIplus.
6.1 Auxiliary1 setpoint
6.2 Auxiliary2 setpoint
6.3Sensor 2 overheatingtemperature
6.4Waterpumpoperatingmode
6.5Auxiliary 1 manualmode enable
6.6Auxiliary 2 manualmode enable
7.ACCESSMENUFOR ADJUSTINGTHECONNECTION
7.1 Microsol II plusaddress
Wall-Link
03-S2 Hi Temp 05-A1 Man Mode
04-Pmp Activat
01-McSol 485 Add
02-Search McSol
06-A2 Man Mode
Only with Microsol II plus from version 03
01-Setpoint A1
02-Setpoint A2
7.2Search Microsol IIplus
8.SETUP MENU
8.1McSol2 485 Add
8.2Interface
Pressing on this function makes start searching for Microsol II plus address
automatically.Enterthequickaccessmenuagaintostoptheautomaticsearch.
The operating characteristics of can be adjusted through the setup menu. To access the
functionmenupress and keyssimultaneouslyforeightsecondsuntilthefunctionsareshown
inthedisplay.Thefollowingoptionsareavailableinthesetupmenu:
ThisfunctionallowstomanuallyadjustingtheaddressoftheMicrosolIIpluscontroller.
ThevaluesetforthisfunctionshouldbethesamevaluesetontheMicrosolIIplus.
Allowsadjustingtheuserinterfacecharacteristics:
Wall-Link
Wall-Link
01-McSol 485 Add 04-Timeouts
02-Interface
03-Descriptions
05-Statistics
Descrição Mín. Máx. Unid
Fun Padrão
S1
-
1
0
Off
All
-
10
999
On
-
-
-
min.
-
Indication
Language
Display contrast
Display timeout
Sound signaling
S2
Port
5
0
Off
I01
I02
I03
I04
I05

8.3Descriptions
AllowstoadjusttheMicrosolIIplussensorsdisplaymessage.Themessageselectedwillbeusedon
the mainscreentoindicatewhichtemperatureisbeingdisplayed.Wall-Link
1-Description S1
2-Description S2
3- S3Description
Sensor1description
Sensor2description
Sensor3description
8.5Statistics
Thisfunctionallowsviewingon-screenstatisticsonwiredcommunication,bydisplayingthenumberof
errors in requesting data from the Microsol II plus ( ) and the number of errors in sending
functions( ). Scan Err
Rx Err
Fun
sec.
-
msec.
msec.
msec.
x100ms
999
10
999
999
999
999
Time to scan for the Microsol II plus.
Number of communication failures before error indication
Delay for receiving data
Delay for receiving events schedule
Delay for sending functions
Time for displaying the SPC message
Description Min. Max. Unit Default
T01
T02
T03
T04
T05
T06
8.4Timeouts
AllowsadjustingthetimingsfortheRFcommunications:
1
1
60
60
60
25
1
3
200
200
200
25
Aux1status
Pump Aux1 Aux2
%$%&
9.2Outputs status
Waterpumpstatus Aux2status
$
%
$&
%&
Time
Tuesday
14:19
Dayofweek
Outputoff;
Outputon;
Manualoperatedoutputoff;
Manualoperatedoutputon;
9.1Day of weekandtime
9.Other views
Pressing thekey repeatedlyyoucanviewotherinformationfromtheMicrosolIIplus.Theselected
visualizationwillremainonthedisplayfor10secondsandafterthistimeitwillreturntothemainscreen.
Theoptionsavailableare:
S1: 104 S2:56.6
S3:39.6 Df:47.4
9.3Viewing alltemperatures
10.INDICATORS
AlarmofminimumtemperatureonthesensorS1
AlarmofmaximumtemperatureonthesensorS1
Only with Microsol II plus from version 03
Wall-LinkisunabletolocateMicrosolIIplusataddress1;
Hightemperaturealarm;
Freezingtemperaturealarm;
Sensordisconnected.
Min TempS1
MaxS1 Temp
Temperatureatsensor2
Temperatureatsensor3 Diferential temperature
(S1-S2)
Temperatureatsensor1
IMPORTANT
AccordingtoNBR5410andIEC60364standards:
Install sonpowersupply.protectorsagainstoverload
For more information contact our application eng. department through e-mail
Mere illustrative image
Distribution
box
11.WIRING DIAGRAM
Microsol II plus
AA
BB
AB
RS-485
Wall-Link
Sensor 2
26.9$C
PUMPAUX1
MICROSOLII plus
Other Full Gauge Recording Equipment manuals
Popular Recording Equipment manuals by other brands

DNF Controls
DNF Controls 2044CL-O-EVS user manual

herdstar
herdstar BinTrac HouseLINK HL-10P Installation and operation manual

GSi
GSi GEMINI Desktop user manual

Raypak
Raypak Metasys Interface T-2 Specifications

Microtrol
Microtrol Black Pear RBC-TSI1 Installation and operating instructions

HP