Funkwerk bintec R230a Instruction manual

Copyright ©May 3, 2006 Funkwerk Enterprise Communications GmbH
Version 2.0
User’s Guide
bintec R230a / R230aw / R232b / R232bw
Technical Data

Purpose This document is part of the user’s guide to the installation and configuration of bintec gateways run-
ning software release 7.2.10 or later. For up-to-the-minute information and instructions concerning the
latest software release, you should always read our Release Notes, especially when carrying out a
software update to a later release level. The latest Release Notes can be found at www.funkwerk-
ec.com.
Liability While every effort has been made to ensure the accuracy of all information in this manual, Funkwerk
Enterprise Communications GmbH cannot assume liability to any party for any loss or damage caused
by errors or omissions or by statements of any kind in this document and is only liable within the scope
of its terms of sale and delivery.
The information in this manual is subject to change without notice. Additional information, changes and
Release Notes for bintec gateways can be found at www.funkwerk-ec.com.
As multiprotocol gateways, bintec gateways set up WAN connections in accordance with the system
configuration. To prevent unintentional charges accumulating, the operation of the product should be
carefully monitored. Funkwerk Enterprise Communications GmbH accepts no liability for loss of data,
unintentional connection costs and damages resulting from unsupervised operation of the product.
Trademarks bintec and the bintec logo are registered trademarks of Funkwerk Enterprise Communications GmbH.
Other product names and trademarks mentioned are usually the property of the respective companies
and manufacturers.
Copyright All rights are reserved. No part of this publication may be reproduced or transmitted in any form or by
any means – graphic, electronic, or mechanical – including photocopying, recording in any medium,
taping, or storage in information retrieval systems, without the prior written permission of Funkwerk En-
terprise Communications GmbH. Adaptation and especially translation of the document is inadmissible
without the prior consent of Funkwerk Enterprise Communications GmbH.
Guidelines and standards bintec gateways comply with the following guidelines and standards:
R&TTE Directive 1999/5/EG
CE marking for all EU countries and Switzerland
You will find detailed information in the Declarations of Conformity at www.funkwerk-ec.com.
How to reach Funkwerk
Enterprise Communications
GmbH
Funkwerk Enterprise Communications GmbH
Suedwestpark 94
D-90449 Nuremberg
Germany
Telephone: +49 180 300 9191 0
Fax: +49 180 300 9193 0
Internet: www.funkwerk-ec.com
Bintec France
6/8 Avenue de la Grande Lande
F-33174 Gradignan
France
Telephone: +33 5 57 35 63 00
Fax: +33 5 56 89 14 05
Internet: www.bintec.fr

Technical Data bintec User’s Guide 1
1bintec R230a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Delivery size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 General Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5.1 Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5.2 Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5.3 ADSL Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2bintec R230aw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1 Delivery size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 General Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.4 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.5 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.5.1 Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.5.2 Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.5.3 ADSL Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3bintec R232b . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.1 Delivery size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.2 General Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.5 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.5.1 Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

2 bintec User’s Guide Technical Data
3.5.2 Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
3.5.3 ADSL Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
3.5.4 ISDN Basic Rate Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
4bintec R232bw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
4.1 Delivery size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
4.2 General Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
4.3 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
4.4 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
4.5 Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
4.5.1 Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
4.5.2 Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
4.5.3 ADSL Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
4.5.4 ISDN Basic Rate Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Technical Data bintec User’s Guide 3
1
Delivery size
1 bintec R230a
All products of the R Series provide you with a similar set of functions and
differ in terms of the supported interfaces or connection types.
1.1 Delivery size
Your gateway is supplied with the following parts:
■Cable sets/power supply:
– Ethernet cable
– Serial cable
– DSL cable
– Power supply
■Funkwerk Companion CD
■Documentation:
–Quick Install Guide (printed)
–User’s Guide (on CD)
–Release Notes, if required
– Safety Instructions
1.2 General Product Features
The general product features cover performance features and the techni-
cal requirements for installation and operation of your gateway.
These features are outlined in the following table:
Feature Data
Product name bintec R230a

4 bintec User’s Guide Technical Data
1bintec R230a
Dimensions/weight (B x H x D):
Dimensions without cables
Weight
Transport weight (incl. documenta-
tion, cabling, packaging)
158 mm x 25,7 mm x 123.1 mm
approx. 550 g
approx. 1.2 kg
Memory 32 MB SDRAM,
8 MB Flash-ROM
LEDs 11 (1x Power, 1x Status, 4x2 Ethernet,
1x ADSL)
Power consumption of equipment 4.7 Watt
Voltage supply 12V DC 500mA EU PSU
Ambient requirements:
Storage temperature
Ambient temperature
Relative humidity
Room classification
-20° to +70°C
0 to 40 °C
10 to 90% non-condensing in opera-
tion
5 to 95% non-condensing in storage
Operate only in dry rooms.
Available interfaces:
ADSL interface
Serial interface V.24
Ethernet IEEE 802.3 LAN
(4 port switch)
Built-in ADSL modem for Annex A
Built-in, supports the following baud
rates: 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200 bauds
Built-in (twisted-pair only),
10/100 Mbps, auto sensing, MDIX
Plugs used:
Serial interface
Ethernet interface
ADSL interface
3-pole MiniUSB
RJ45
RJ11
Feature Data

Technical Data bintec User’s Guide 5
1
LEDs
Table 1-1: General product features
1.3 LEDs
The LEDs on your R Series Gateway indicate the states and the activity of
the gateway.
They are arranged as follows:
Figure 1-1: LEDs on bintec R230a
In operational mode the LEDs display the following status information:
SAFERNETTM Security Technol-
ogy
Community Passwords, PAP, CHAP,
MS-CHAP, MS-CHAP v.2, PPTP,
PPPoE, PPPoA, Access Control Lists,
NAT, SIF, MPPE Encryption, VPN
with IPSec
Software includes BRICKware for Windows
BRICKtools for Unix
Printed documentation included Quick Install Guide
Documentation in PDF format User’s Guide
BRICKware for Windows
Software Reference
LED Status Information
Power on Power supply has been connected.
Feature Data

6 bintec User’s Guide Technical Data
1bintec R230a
Table 1-2: LED status display
1.4 Connections
All connections are located on the rear of the gateway. bintec R230a offers
a 4-port Ethernet switch, an ADSL interface as well as a serial interface.
The connections are arranged as follows:
Figure 1-2: bintec R230a rear
Status on
flashing
The gateway is booting.
The gateway is active.
1 to 4 on
flashing
The gateway is connected to the Ethernet
(100 Mbit/s or 10 Mbit/s respectively).
Data traffic via the Ethernet interface (100
Mbit/s or 10 Mbit/s respectively).
ADSL on ADSL connection is active.
1. Reset Reset Button 4.
4/3/2/1
10/100 Base-T Eth-
ernet interface
2.
PWR
Socket for power sup-
ply
6. ADSL ADSL interface
3.
Console
Serial interface
LED Status Information

Technical Data bintec User’s Guide 7
1
Pin Assignments
1.5 Pin Assignments
1.5.1 Serial Interface
For connecting a console bintec R230a provides a serial interface. Baud
rates between 1200 and 115200 Bit/s are supported.
The interface is connected through a 5-pole MiniUSB socket:
Figure 1-3: 5-pole MiniUSB socket
The pin assignment of the socket is as follows:
Table 1-3: Pin assignment of the serial socket
1.5.2 Ethernet Interface
bintec R230a offers an Ethernet interface with integrated 4-port switch for
LAN connection. It can be used to connect single PCs as well as addition-
al switches.
Pin Function
1not used
2Rx
3 GND
4not used
5Tx

8 bintec User’s Guide Technical Data
1bintec R230a
An RJ45 socket is used for connecting:
Figure 1-4: Ethernet 10/100Base-T interface (RJ45 socket)
The Ethernet sockets have the following pin assignment
Table 1-4: RJ45 socket for LAN connections
The Ethernet sockets are not equipped with Auto-MDIX technology.
1.5.3 ADSL Interface
The ADSL interface is connected using a RJ11 socket. The supplied cable
combines the RJ11 plug required by most ADSL splitters and the RJ11
plug required by the gateway.
Pin Function
1TD +
2TD -
3RD +
4Not used
5Not used
6RD -
7Not used
8Not used

Technical Data bintec User’s Guide 9
1
Pin Assignments
Only the inner pins are used for the ADSL connection:
Figure 1-5: ADSL interface (RJ11)
The ADSL interface has the following pin assignment:
Table 1-5: ADSL interface (RJ11 socket)
Pin Function
1Not used
2 a
3 b
4Not used

10 bintec User’s Guide Technical Data
1bintec R230a

Technical Data bintec User’s Guide 11
2
Delivery size
2 bintec R230aw
All products of the R Series provide you with a similar set of functions and
differ in terms of the supported interfaces or connection types.
2.1 Delivery size
Your gateway is supplied with the following parts:
■Cable sets/power supply:
– Ethernet cable
– Serial cable
– DSL cable
– Power supply
■Antennas:
– two standard antennas
■Funkwerk Companion CD
■Documentation:
–Quick Install Guide (printed)
–User’s Guide (on CD)
–Release Notes, if required
– Safety Instructions
2.2 General Product Features
The general product features cover performance features and the techni-
cal requirements for installation and operation of your gateway.

12 bintec User’s Guide Technical Data
2bintec R230aw
These features are outlined in the following table:
Feature Data
Product name bintec R230aw
Dimensions/weight (B x H x D):
Dimensions without cables
Weight
Transport weight (incl. documenta-
tion, cabling, packaging)
158 mm x 25,7 mm x 123.1 mm
approx. 550 g
approx. 1.2 kg
Memory 32 MB SDRAM,
8 MB Flash-ROM
LEDs 12 (1x Power, 1x Status, 4x2 Ethernet,
1x WLAN, 1x ADSL)
Power consumption of equipment 4.7 Watt
Voltage supply 12V DC 800mA EU PSU
Ambient requirements:
Storage temperature
Ambient temperature
Relative humidity
Room classification
-20° to +70°C
0 to 40 °C
10 to 90% non-condensing in opera-
tion
5 to 95% non-condensing in storage
Operate only in dry rooms.

Technical Data bintec User’s Guide 13
2
General Product Features
Table 2-1: General product features
Available interfaces:
ADSL interface
Serial interface V.24
Ethernet IEEE 802.3 LAN
(4 port switch)
WLAN interface (antennas)
Built-in ADSL modem for Annex A
Built-in, supports the following baud
rates: 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200 bauds
Built-in (twisted-pair only),
10/100 Mbps, auto sensing, MDIX
802.11b and 802.11g with Antenna
Diversity
Data rates of 1-, 2-, 5.5-, 6-, 9-, 11-,
12-, 18-, 24-, 36-, 48-, 54 Mbps
Plugs used:
Serial interface
Ethernet interface
ADSL interface
3-pole MiniUSB
RJ45
RJ11
SAFERNETTM Security Technol-
ogy
Community Passwords, PAP, CHAP,
MS-CHAP, MS-CHAP v.2, PPTP,
PPPoE, PPPoA, Access Control Lists,
NAT, SIF, MPPE Encryption, VPN
with IPSec
Software includes BRICKware for Windows
BRICKtools for Unix
Printed documentation included Quick Install Guide
Documentation in PDF format User’s Guide
BRICKware for Windows
Software Reference
Feature Data

14 bintec User’s Guide Technical Data
2bintec R230aw
2.3 LEDs
The LEDs on your R Series Gateway indicate the states and the activity of
the gateway.
They are arranged as follows:
Figure 2-1: LEDs on bintec R230aw
In operational mode the LEDs display the following status information:
Note
Antenna Diversity
The two antennas do not have equal funtion. The one named "Main", "Primary"
or "1" (at R Series devices the antenna next to the power switch) is used for
sending and receiving, the other one only for receiving. The AP (Access point)
verifies, which of the two antennas receives the better signal, which is then
used for decoding.
LED Status Information
Power on Power supply has been connected.
Status on
flashing
The gateway is booting.
The gateway is active.
1 to 4 on
flashing
The gateway is connected to the Ethernet
(100 Mbit/s or 10 Mbit/s respectively).
Data traffic via the Ethernet interface (100
Mbit/s or 10 Mbit/s respectively).
WLAN on
flashing
The WLAN module is active.
Data traffic via the WLAN interface.

Technical Data bintec User’s Guide 15
2
Connections
Table 2-2: LED status display
2.4 Connections
All connections are located on the rear of the gateway. bintec R230aw of-
fers a 4-port Ethernet switch, an ADSL interface as well as a serial inter-
face.
The connections are arranged as follows:
Figure 2-2: bintec R230aw rear
ADSL on ADSL connection is active.
1. Reset Reset Button
2.
POWER
Socket for power sup-
ply
6. ADSL ADSL interface
3.
CON-
SOLE
Serial interface 8. RSMA connection
4.
4/3/2/1
10/100 Base-T Ether-
net interface
LED Status Information

16 bintec User’s Guide Technical Data
2bintec R230aw
2.5 Pin Assignments
2.5.1 Serial Interface
For connecting a console bintec R230aw provides a serial interface. Baud
rates between 1200 and 115200 Bit/s are supported.
The interface is connected through a 5-pole MiniUSB socket:
Figure 2-3: 5-pole MiniUSB socket
The pin assignment of the socket is as follows:
Table 2-3: Pin assignment of the serial socket
2.5.2 Ethernet Interface
bintec R230aw offers an Ethernet interface with integrated 4-port switch
for LAN connection. It can be used to connect single PCs as well as addi-
tional switches.
Pin Function
1not used
2Rx
3 GND
4not used
5Tx

Technical Data bintec User’s Guide 17
2
Pin Assignments
An RJ45 socket is used for connecting:
Figure 2-4: Ethernet 10/100Base-T interface (RJ45 socket)
The Ethernet sockets have the following pin assignment
Table 2-4: RJ45 socket for LAN connections
The Ethernet sockets are not equipped with Auto-MDIX technology.
2.5.3 ADSL Interface
The ADSL interface is connected using a RJ11 socket. The supplied cable
combines the RJ11 plug required by most ADSL splitters and the RJ11
plug required by the gateway.
Pin Function
1TD +
2TD -
3RD +
4Not used
5Not used
6RD -
7Not used
8Not used

18 bintec User’s Guide Technical Data
2bintec R230aw
Only the inner pins are used for the ADSL connection:
Figure 2-5: ADSL interface (RJ11)
The ADSL interface has the following pin assignment:
Table 2-5: ADSL interface (RJ11 socket)
Pin Function
1Not used
2 a
3 b
4Not used
Other manuals for bintec R230a
8
This manual suits for next models
3
Table of contents
Other Funkwerk Network Router manuals

Funkwerk
Funkwerk R3000w User manual

Funkwerk
Funkwerk bintec R4100 User manual

Funkwerk
Funkwerk bintec R1200 User manual

Funkwerk
Funkwerk bintec R1200 User manual

Funkwerk
Funkwerk R3400 User manual

Funkwerk
Funkwerk bintec R230a User manual

Funkwerk
Funkwerk elmeg t444 User manual

Funkwerk
Funkwerk bintec R4100 User manual

Funkwerk
Funkwerk bintec R230a User manual

Funkwerk
Funkwerk bintec R1200 User manual