GAI-Tronics 10961-101 User manual

Pub. 42004-401D
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
GAI-TRONICS®
AHUBBELL COMPANY
Model 10961-101
AMI Centra-Page Interface
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-
Tronics retains all intellectual property and other rights in or to the information contained herein, and
such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
GAI-Tronics’ Centra-Page systems provide dependable paging and party line communications for rugged
and hazardous industrial facilities. Centra-Page systems feature centrally located electronics that provide
environmental protection and unitized amplification for easy maintenance.
Standard Centra-Page cabinets can support up to 30 handset stations, and in most cases, up to 60 paging
speakers. Alarms and telephone interfacing can be added to Centra-Page systems with the addition of a
Model 10959-208 Audio Messenger Interface (AMI) and a Model 10961-101 AMI Centra-Page Interface.
The Model 10961-101 AMI Centra-Page Interface, in combination with the AMI, can replace the Model
H97019 Programmable Tone/Speech Generator and the Model 10448-202 Telephone Interface for
Centra-Page systems or the Model GTB93017 Programmable Telephone Interface in CP/P II systems.
The Model 10961-101 AMI Centra-Page Interface is designed to provide five alarm inputs to activate the
Model 10959-208 AMI’s tone/speech generator when both are mounted in a Model 10468-002 Centra-
Page Central Cabinet and are properly configured.
The AMI Centra-Page Interface can provide Centra-Page systems access to the public telephone network.
The telephone line coupler is designed for loop start operation with bridged ringing. This coupler is
registered by the FCC number ADGOT01B46055. The Ringer Equivalence Number (REN) is 0.1A, with
an RJ11C connection.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 2 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
The Model 10961-101 AMI Centra-Page Interface contains a priority alarm test panel and a telephone
interface panel. The 69542-001 PCBA and 69407-002 I/O Controller PCBA are mounted on the rear
along with a power terminal block. The AMI Centra-Page Interface outline is shown in Figure 1.
IN USE
SUBSET
TELEPHONE
ACCESSNIGHT
DAY
DISCONNECT
TELEPHONE INTERFACE
PRIORITY ALARM TEST
CLEAR
54321
Figure 1. Model 10961-101 AMI Centra-Page Interface

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 3 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Installation
Power Disconnect. The power cord is the main power disconnect for all units.
Disjontion de l’alimentation. Le cordon d’alimentation est la disjonction d’alimentation principale tous les appareils.
Para Desconectar la Alimentación: El cable de alimentación es el medio principal de desconexión del equipo.
Netzanschluß. Wenn man das Netzkabel aus der Steckdose zieht, dann ist die Spannungszuführung zum Gerät vollkommen
unterbrochen.
CAUTION To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
ATTENTION Pour réduire le risque d’incendie, utiliser uniquement des conducteurs de télécommunications 26 AWG ou
de section supérieure.
PRECAUCIÓN Para aminorar la posibilidad de incendios, utilice solamente cable de telecomunicaciones de calibre 26
(sistema AWG americano) o mayor.
VORSICHT Um die Brandgefahr zu verringern, verwenden Sie bitte nur Fernmeldekabel der Stärke Nr. 26 AWG oder
höher.
WARNING Do not apply power until all the connections have been wired.
WARNING Connect only to a UL-listed Class 2 power source.
If replacing existing equipment, remove the tone generator, telephone interface, and the associated wiring
prior to installing the Model 10961-101 Interface.
The Model 10961-101 AMI Centra-Page Interface and the Model 10959-208 AMI should be installed in
the Centra-Page central cabinet at the same time. Allow 6U of open space immediately below the Model
10461-002 Card Rack in the lowest position in the cabinet to mount the AMI, and immediately beneath it,
the Centra-Page Interface. Refer to Figure 2.
NOTE:The standard lengths of the interconnecting cables do not allow for blank panel space between
these pieces of equipment.
1. Carefully unpack and identify the various components. The Model 10959-208 AMI includes a parts
envelope containing mounting hardware, a CD, and a 12 V dc Walpac. The Model 10961-101 AMI
Centra-Page Interface includes a parts envelope containing seven cable assemblies, four mounting
screws, a Flash Memory card, a modular RJ11 splitter, a 33-ohm resistor, and a Centra-Page terminal
block label. The seven cable assemblies are:
61531-033 61531-038
61531-041 (9-inch green ground wire)
61531-034 61531-039
61531-035 61531-040
2. Use the mounting hardware supplied with the AMI to mount it directly below the bottom card rack.
The AMI occupies 1U of space.
3. Make all the required wiring connections before mounting the Model 10961-101 AMI Centra-Page
Interface. Refer to Figure 4 and Figure 5.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 4 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
IN USE ACCESS DISCONNECT
TELEPHONE INTERFACE
PRIORITY ALARM TEST
TELEPHONE
SUBSET
NIGHT
DAY
CLEAR12 3 4 5
Figure 2. Centra-Page Central Cabinet with AMI and AMI Centra-Page Interface
(front of center section)

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 5 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
AUDIO DIGITALINPUTS DIGITAL OUTPUTS
ETHERNET
SYSTEM
CLASS 2/CLA SSE 2
12-24 V DC
PBX
PAGE / PA RTY
Figure 3. Centra-Page Central Cabinet
(Showing front of rear section and the rear of the center section)

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 6 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Figure 4. Wiring of Central Cabinet’s wall-mounted section

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 7 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Figure 5. Wiring of the rear of the Central Cabinet’s center section

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 8 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
NOTE:The connectors for TB6 (power) and TB3 (audio) from the back of the AMI must be attached
(terminated) to the cable assemblies according to the steps 4 and 5 below:
4. Remove TB3 (AUDIO) connector from the back of the AMI. Attach the mating end of the connector
to the 61531-034 cable assembly. See Figure 6. Using this 10-position removable terminal block,
connect the six wires from positions 1 through 6 of the 61531-034 cable assembly. The brown and
black wires from positions 9 and 10 are not connected to this terminal block. Refer to Figure 5.
Figure 6. 61531-034 Cable Assembly
Connector from AMI TB3 (Audio)
Terminal Wire Color Function
TB3-1 Purple + Page or alarm from AMI
TB3-2 Blue −Page or alarm from AMI
TB3-3 Red + Party line from AMI
TB3-4 Green −Party line from AMI
TB3-5 Yellow + Party line to AMI
TB3-6 Orange −Party line to AMI
TB3-7 thru N/C
TB3-10

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 9 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
5. Remove TB6 (power) connector plug from its socket on the back of the AMI. Attach the TB6
connector plug to the 61531-040 cable assembly conductor ends that do not have spade lugs. Refer to
Figure 7.
Figure 7. 61531-040 Cable Assembly Connector Termination
6. Connect the 61531-038 and 61531-039 cable assemblies to the outside of TB1 (mounted on the AMI
Centra-Page Interface plate) and the 61531-040 cable assembly to the inside of TB1.
TB1 on AMI Centra-Page Interface Panel
Terminal Wire Color Function
TB1-1 Red +24 V dc
TB1-2 Black (−) of 24 V dc
TB1-3 Green Ground
7. Connect the 61531-033 cable connector to TB1 on the 69542-001 PCBA.
8. Connect the 61531-034 cable connector (the end without the brown and black wires) to TB3 on the
69542-001 PCBA. Connect the brown and black wires to TB2 on the 69407-002 PCBA.
TB2 on 69542-001
Terminal Wire Color Function
TB2-1 Brown +RS-485 data
TB2-2 Black −RS-485 data
9. Connect the 61531-035 cable connector to TBX04 on the 69542-001 PCBA.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 10 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
10. Mount the Model 10961-101 Interface directly beneath the AMI in the Centra-Page central cabinet.
11. Connect the 61531-038 cable assembly to the central cabinet’s TB11 located on the rear panel. See
Figure 4.
Centra-Page Cabinet Back Panel - Power -TB11
Terminal Wire Color Function
TB11-1 Red +24 V dc
TB11-2 Black (−) of 24 V dc
TB11-3 Green Ground
11. Connect the red and black wires of cable assembly 61531-039 to the TBX05 terminal block on the
card rack located in the lowest mounting position. Connect the green wire from the 61531-039 cable
assembly and one end of the 61531-041 grounding wire to the grounding lug on the back of the AMI.
Connect the other end of the 61531-041 to the card rack’s TBX05 terminal block.
Figure 8. 61531-039 Cable Assembly Termination

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 11 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
12. Plug the 61531-040 cable’s TB6 connector (attached in step 5) back into its original location on the
rear of the AMI.
13. Install the Centra-Page terminal block label beneath TB13 on the central cabinet’s rear panel.
Connect the 61531-033 cable to the central cabinet’s back panel TB12 (ALARM) and TB13
(INTERFACE). Refer to Figure 4.
Centra-Page Cabinet Back Panel - Alarm -TB12
Terminal Wire Color Function
TB12-4 Tan/black Priority 1
TB12-5 White/green Priority 2
TB12-6 Green/white Priority 3
TB12-7 Black/yellow Priority 4
TB12-8 Red Priority 5
TB12-9 Blue Reset
TB12-10 Black Switch common
TB12-11 NC Ground
Centra-Page Cabinet Back Panel - Interface - TB13
Terminal Wire Color Function
TB13-12 Brown Switch common
TB13-13 Yellow Access
TB13-14 White Disconnect
TB13-15 Orange Day/Night
TB13-16 NC NC
TB13-17 NC NC
TB13-18 NC NC
TB13-19 NC NC

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 12 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
14. Connect the 61531-035 cable assembly to the bottom card rack’s TBX04 according to the table
below, except for the black wire, which goes to the position 2 of the terminal block for the crew’s
quarters.
Card Rack - TBX04
Terminal Wire Color Function
TBX04-4 Orange Alarm mute
TBX04-5 Yellow Alarm
TBX04-6 Red/blue Page
TBX04-7 Black/yellow Alarm common
TBX04-8 Red Party 2
TBX04-9 Tan/red Party common
TBX04-10 Violet Party 1
TBX04-11 Blue/red Page common
15. Install the modular RJ11 splitter into the RJ11 jack on the rear on the AMI. Connect the phone cable
from the AMI Centra-Page Interface into one of the splitter RJ11 jacks. Connect the telephone line
into the other splitter RJ11 jack.
16. Remove the Flash Memory card from the AMI and replace it with the Flash Memory card that came
with the AMI Centra-Page Interface. Keep the Flash Memory card as a spare.
NOTE:The 12 V dc Walpac is not used in this installation.
17. Connect the 33-ohm resistor to Page L1 and L2 on the P1 connector of the AMI.
18. All field wiring is brought into the terminal blocks on the cabinet back panel. After the field wiring is
connected, apply 24 V dc to TB11 on the central cabinet’s rear panel. Refer to Figure 3.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 13 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Startup
The AMI begins its startup procedure when 24 V dc is applied. When the startup procedure is complete,
the AMI will be communicating with the 69407-002 I/O controller PCBA on the Model 10961-101
Interface.
“System Up” will be displayed on the AMI. When viewed from the rear of the cabinet, LED1 on the
69407-002 should be flashing. Use the display and the buttons on the front of the AMI to set the time and
date. Refer to GAI-Tronics Pub. 42004-345 for more setup and operation information for the AMI.
Quick Test
1. Press the PRIORITY 1button on the front of the Interface panel to play the Alarm 1 tone over the
Centra-Page station and the crew’s quarters speakers.
2. Press the CLEAR button on the front panel of the AMI Centra-Page Interface to stop the alarm tone.
3. Set the DAY/NIGHT switch on the front of the AMI Centra-Page Interface panel to Night Mode. Call
the AMI from an external line or a phone with a different number than the AMI.
4. When ringing can be heard through the Centra-Page system, press the ACCESS button on the front
of the Interface panel to answer the phone.
5. From a Centra-Page station set to party line 1, take the handset off-hook. There should be two-way
audio with the calling phone.
6. Press the DISCONNECT button on the front of the AMI Centra-Page Interface panel to hang up the
phone.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 14 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Operation
General
The Model 10959-208 AMI has an on-board MP3 player that generates pre-recorded tones and speech
messages. It stores these sound and its configuration files on a Flash Memory card. It also contains a
telephone interface PCBA that connects to the Public Switched Telephone Network (PSTN).
The Model 10961-101 AMI Centra-Page Interface is designed to allow the capabilities of the AMI to be
used by a Centra-Page system. The AMI Centra-Page Interface contains two boards: the 69407-002 I/O
controller and the 69542-001 AMI Centra-Page Interface PCBAs. The interface connects the alarm, page,
and party audio between the AMI and the Centra-Page system. In addition, the panel and remote switches
connect to the AMI Centra-Page Interface communicating their state to the AMI.
Alarms and Paging
Five alarms can be activated from the push buttons on the front panel of the AMI Centra-Page Interface or
from remote switches (momentary/N.O.). The alarms can be cleared or reset using the push button on the
front panel. For convenience, a remote switch can be connected to control each alarm. Use terminal
block TB11 on the Centra-Page central cabinet’s rear panel to connect the remote switches.
Each alarm plays a different tone and each has a different priority level assigned to it. Alarm 1 has the
highest priority and Alarm 5 the lowest. If an alarm tone is playing and a higher priority alarm is
activated, the higher priority will override the lower priority alarm. Pot 15 on the 69542-001 PCBA
adjusts the alarm audio level.
If an alarm is playing and someone makes a page from a Centra-Page station the alarm will be reduced by
-7 dB and the page will play over top of the alarm. If the alarm is still active when the page is complete,
the alarm level will return to its normal level.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 15 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Crew’s Quarters Muting
The crew’s quarters speakers are normally muted and no alarms or pages are broadcast. The Model
10961-101 Interface has an output that allows the crew’s quarters speakers to be unmuted so that selected
alarms can be heard. The output can be set up so that it is active when one or all of the first three alarms
are played.
Jumpers P1 to P3 are used to select alarms 1 to 3. Putting the jumper across positions 1 and 2 makes the
output inactive for that alarm and putting the jumper in positions 2 and 3 activates the output for that
alarm. The output is on TBX04 on the AMI Centra-Page Interface’s 69542-001 PCBA. It is position 9 of
TBX04 and will have a black wire long enough to connect to the back panel of the Crew’s Quarters
terminal block.
P3
P2
P1
Figure 9. Crew’s Quarters Jumpers on the 69542-001 PCBA in the
Model 10961-101 AMI Centra-Page Interface

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 16 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Telephone Interface
The Model 10959-208 AMI connects to the PSTN, and through the Model 10961-101 AMI Centra-Page
Interface, connects to the Centra-Page system. Pressing the Interface’s front panel ACCESS and
DISCONNECT buttons causes the AMI to take the phone line on or off-hook. Pot R10 on the 69542-001
PCBA can adjust the level of the audio from the phone line to the Centra-Page party line.
NOTE:The IN USE LED on the front panel of the Interface lights when the phone line is connected to
party line 1.
There are two modes of operation: Day mode and Night mode. The Day/Night mode toggle switch on the
Interface’s front panel is used to switch between the two modes. If the toggle switch is put in the Night
position, a remote switch (maintained) connected to terminal block TB13 on the rear panel of the Centra-
Page Central Cabinet can be used.
Day Mode
An attendant, with access to a phone on the same line as the AMI and a Centra-Page station, answers the
incoming call and pages the person being called. When that person answers on party line 1 of the Centra-
Page system, the attendant presses the ACCESS button to connect the phone line to the party line. Upon
completion of the call, the attendant presses the DISCONNECT button to hang up the phone line.
If the attendant is not there, the AMI will auto-answer after the fourth ring. The caller will hear two
beeps, and can then make a live page. When a Centra-Page station goes off-hook after the page, the
phone is connected to party line 1. The AMI will go back on-hook 15 seconds after the station goes back
on-hook.
Night Mode
In night mode an incoming call is auto-answered after one ring. The ring message is played over the
paging system until a Centra-Page station on party line 1 goes off-hook. The page then stops and the
phone line is connected to party line 1. The AMI will go back on-hook 15 seconds after the station goes
back on-hook.
There is a one-minute time out if the page is not answered and then the AMI will hang up the call.

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 17 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Options
The configuration on the Flash Memory card in the AMI contains all the parameters for alarm, paging and
telephone operation. To change any of these operating parameters, the ACT software that comes with the
AMI must be installed on a PC with a card reader. Using the ACT software, the configuration can be
edited and the Flash Memory card can be reprogrammed.
The ACT software has a Default AMI Centra-Page configuration template available from Configuration
pull down window. Select “Add New” then from the New Configuration window, select AMI Centra
Page Default, and give the new configuration a unique name. The new configuration will show up in the
list of configurations and can be selected and edited.
Use ACT Software Version 2.1.9M or greater for creating default Centra-Page configurations.
Using Optional Inputs and Outputs
To use the optional inputs and outputs on the AMI and I/O controller PCBA, the AMI configuration must
be changed. Refer to the Model 10959-208 AMI manual, GAI-Tronics Pub. 42004-345, and online help
to set them up. The charts below show the layouts for the inputs and outputs.
Input Layout for Default AMI Centra Page Configuration
Inputs in ACT
Configuration
Where Input Terminal is Located:
Description
1 Input 1 on AMI TB2 (Audio): 2 & 1 Not used
2 Input 2 on AMI TB2 (Audio): 3 & 1 Not used
3 Input 3 on AMI TB2 (Audio): 4 & 1 Not used
4 Input 4 on AMI TB2 (Audio): 5 & 1 Not used
5 Input 5 on AMI TB2 (Audio): 6 & 10 Not used
6 Input 6 on AMI TB2 (Audio): 7 & 10 Not used
7 Input 7 on AMI TB2 (Audio): 8 & 10 Not used
8 Input 8 on AMI TB2 (Audio): 9 & 10 Not used
9 On rear panel TB12:4, 10 (PRIORITY 1, SW. COM.) Alarm 1
10 On rear panel TB12:5, 10 (PRIORITY 2, SW. COM.) Alarm 2
11 On rear panel TB12:6, 10 (PRIORITY 3, SW. COM.) Alarm 3
12 On rear panel TB12:7, 10 (PRIORITY 4, SW. COM.) Alarm 4
13 On rear panel TB12:8, 10 (PRIORITY 5, SW. COM.) Alarm 5
14 On rear panel TB12:9, 10 (Reset, SW. COM.) Clear Alarms
15 Input 7 on I/O controller TB5:13, 14 Not used
16 Input 8 on I/O controller TB5:15, 16 Not used
17 On rear panel TB13:13, 12 (DISCON., SW. COM.) Phone Disconnect
18 On rear panel TB13:14, 12 (ACCESS, SW. COM.) Phone Access

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 18 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Inputs in ACT
Configuration
Where Input Terminal is Located:
Description
19 On rear panel TB13:15, 12 (MODE SEL., SW.COM.) Day/Night mode
20 Input 12 on I/O controller TB6:7, 8 Station Off-Hook
21 Input 13 on I/O controller TB6:9, 10 Alarm Mute
22 Input 14 on I/O controller TB6:11, 12 Not used
23 Input 15 on I/O controller TB6:13, 14 Not used
24 Input 16 on I/O controller TB6:15, 16 Not used
25 Input 17 on I/O controller TB7:1, 2 Not used
26 Input 18 on I/O controller TB7:3, 4 Not used
27 Input 19 on I/O controller TB7:5, 6 Not used
28 Input 20 on I/O controller TB7:7, 8 Not used
29 Input 21 on I/O controller TB7:9, 10 Not used
30 Input 22 on I/O controller TB7:11, 12 Not used
31 Input 23 on I/O controller TB7:13, 14 Not used
32 Input 24 on I/O controller TB7:15, 16 Not used
33 Input 25 on I/O controller TB8:1, 2 Not used
34 Input 26 on I/O controller TB8:3, 4 Not used
35 Input 27 on I/O controller TB8:5, 6 Not used
36 Input 28 on I/O controller TB8:7, 8 Not used
37 Input 29 on I/O controller TB8:9, 10 Not used
38 Input 30 on I/O controller TB8:11, 12 Not used
39 Input 31 on I/O controller TB8:13, 14 Not used
40 Input 32 on I/O controller TB8:15, 16 Not used

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 19 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Output Layout for Default AMI Centra Page Configuration
Outputs in ACT
Configuration
Where Input terminal is Located:
Description
1 Output 1 on AMI TB1: 2 & 1 Not used
2 Output 2 on AMI TB1: 3 & 1 Not used
3 Output 3 on AMI TB1: 4 & 1 Not used
4 Output 4 on AMI TB1: 5 & 1 Not used
5 Output 5 on AMI TB1: 6 & 10 Not used
6 Output 6 on AMI TB1: 7 & 10 Not used
7 Output 7 on AMI TB1: 8 & 10 Not used
8 Output 8 on AMI TB1: 9 & 10 Not used
9 Output 1 on I/O controller TB10:1 Not used
10 Output 2 on I/O controller TB10:2 Not used
11 Output 3 on I/O controller TB10:3 Not used
12 Output 4 on I/O controller TB10:4 Not used
13 Output 5 on I/O controller TB10:5 Not used
14 Output 6 on I/O controller TB10:6 Not used
15 Output 7 on I/O controller TB10:7 Not used
16 Output 8 on I/O controller TB10:8 Not used
17 Output 9 on I/O controller TB10:9 Not used
18 Output 10 on I/O controller TB10:10 Not used
19 Output 11 on I/O controller TB10:11 Not used
20 Output 12 on I/O controller TB10:12 Not used
21 Output 13 on I/O controller TB10:13 Not used
22 Output 14 on I/O controller TB10:14 Not used
23 Output 15 on I/O controller TB10:15 Not used
24 Output 16 on I/O controller TB10:16 Not used
25 Output 17 on I/O controller TB9:1 Not used
26 Output 18 on I/O controller TB9:2 Priority 1 Crew’s
Quarters active
27 Output 19 on I/O controller TB9:3 Priority 2 Crew’s
Quarters active
28 Output 20 on I/O controller TB9:4 Priority 3 Crew’s
Quarters active
29 Output 21 on I/O controller TB9:5 Telephone Page

Pub. 42004-401D
Model 10961-101 AMI Centra-Page Interface Page: 20 of 22
p:\standard ioms - current release\42004 instr. manuals\42004-401d.doc
02/16
Outputs in ACT
Configuration
Where Input terminal is Located:
Description
30 Output 22 on I/O controller TB9:6 Phone In Use LED
31 Output 23 on I/O controller TB9:7 Not used
32 Output 24 on I/O controller TB9:8 Not used
33 Output 25 on I/O controller TB9:9 Not used
34 Output 26 on I/O controller TB9:10 Not used
35 Output 27 on I/O controller TB9:11 Not used
36 Output 28 on I/O controller TB9:12 Not used
37 Output 29 on I/O controller TB9:13 Not used
38 Output 30 on I/O controller TB9:14 Not used
39 Output 31 on I/O controller TB9:15 Not used
40 Output 32 on I/O controller TB9:16 Not used
NOTE:The ground connections for the outputs on the I/O controller are TB1:1, 2 and any unused input
ground terminals, which are the even number terminals of TB5, TB6, TB7 and TB8. Refer to Figure 10.
Figure 10. I/O Module Terminal Block Layout
Table of contents
Other GAI-Tronics Recording Equipment manuals