manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Galvin Engineering
  6. •
  7. Bathroom Aid
  8. •
  9. Galvin Engineering GalvinAssist CLEVA050 Instruction sheet

Galvin Engineering GalvinAssist CLEVA050 Instruction sheet

Other Galvin Engineering Bathroom Aid manuals

Galvin Engineering GalvinAssist 41992CP Instruction sheet

Galvin Engineering

Galvin Engineering GalvinAssist 41992CP Instruction sheet

Galvin Engineering CliniLever TC51FC1C Instruction sheet

Galvin Engineering

Galvin Engineering CliniLever TC51FC1C Instruction sheet

Galvin Engineering GalvinAssist 41985CP User manual

Galvin Engineering

Galvin Engineering GalvinAssist 41985CP User manual

Galvin Engineering 41999CP User manual

Galvin Engineering

Galvin Engineering 41999CP User manual

Popular Bathroom Aid manuals by other brands

Cobi Rehab XXL-Rehab Rise N Tilt user manual

Cobi Rehab

Cobi Rehab XXL-Rehab Rise N Tilt user manual

Invacare 9630E Styxo Assembly, installation and operating instructions

Invacare

Invacare 9630E Styxo Assembly, installation and operating instructions

Leckey firefly splashy BIG user manual

Leckey

Leckey firefly splashy BIG user manual

NRS Healthcare H85350 User instructions

NRS Healthcare

NRS Healthcare H85350 User instructions

Pressalit Care R2040 Assembly instruction

Pressalit Care

Pressalit Care R2040 Assembly instruction

WENKO 23285100 Assembly instructions

WENKO

WENKO 23285100 Assembly instructions

Dietz SmartCare TAYO operating instructions

Dietz SmartCare

Dietz SmartCare TAYO operating instructions

Invacare Aquatec Ocean user manual

Invacare

Invacare Aquatec Ocean user manual

Roth Mobeli 1400222H2S instruction manual

Roth

Roth Mobeli 1400222H2S instruction manual

ZACK CARVO 40510 quick start guide

ZACK

ZACK CARVO 40510 quick start guide

lopital Elexo Instruction card

lopital

lopital Elexo Instruction card

AddLife SVAN CARE R3 Installation and user manual

AddLife

AddLife SVAN CARE R3 Installation and user manual

Invacare Aquatec ORCA Repair instructions

Invacare

Invacare Aquatec ORCA Repair instructions

SEVERIN LB 7220 manual

SEVERIN

SEVERIN LB 7220 manual

NRS Mowbray Lite Plus User instructions

NRS

NRS Mowbray Lite Plus User instructions

HMN Nielsen Line user guide

HMN

HMN Nielsen Line user guide

Pressalit R6414 Mounting instruction

Pressalit

Pressalit R6414 Mounting instruction

Pressalit R360070 Mounting instruction

Pressalit

Pressalit R360070 Mounting instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Product Installation Guidelines
© Galvin Engineering Pty Ltd
Version 1, 2nd June 2022, Page 1of 4
GalvinAssist®Hand Shower Kit, Inverted LH T 700 X 1100
SS Hygienic G/Rail, ClevaCare Shw –Low
PRODUCT CODES:
- CLEVA050
SPECIFICATIONS
- CP Brass swing arm with stainless steel spring.
- Supplied with stainless steel fasteners.
- Finished in bright chrome plate for easy cleaning and added durability.
IMPORTANT: All Galvin Engineering taps are tested in accordance with AS/NZS 3662 and leave
our premises in good working order.
TECHNICAL DATA
Inlet
 Female
Outlet
Handheld Shower
Headwork
N/A
Working Pressure Range (kPa)
Min
150
Max
500
Working Temperature Range (°C)
Min
5
Max
55
Nominal Flow Rate (LPM)
8.24
Finish
N/A
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change
without notice.
TOOLS REQUIRED
−Power drill
−Spanner or adjustable crescent
© Galvin Engineering Pty Ltd
Version 1, 2 June 2022, Page 2of 4
Product Installation Guidelines
Version 1, 2nd June 2022, Page 2of 4
PRE-INSTALLATION
MOUNTING DETAILS
−If the mounting holes do not already exist, mark out and drill the holes as shown in rough-in
dimensions.
Figure 1








© Galvin Engineering Pty Ltd
Version 1, 2 June 2022, Page 3of 4
Product Installation Guidelines
Version 1, 2nd June 2022, Page 3of 4
INSTALLATION
INSTALLATION COMPLIANCE: Galvin Engineering products must be installed in accordance with these
installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements.
Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of the
product.
1. Top Flange
Mark the height of the top flange centre point by
measuring vertically 2275mm above the floor. Then
measure approximately 150mm horizontally to the
left or right (depending on the position of the
shower recess) of the centre of the existing supply
fitting. Drill 2 holes Ø8 x 50mm deep, 38mm
horizontally apart to suit the top flange.
2. Bottom Flange
Mark the position of the bot
 point. Then mark
the two holes for mounting the bottom flange in a similar
manner to the top flange.
Note: The bottom flange is mounted in a vertical
orientation.
Important: the functionality of this product relies on the
accuracy of the vertical alignment between the top and
bottom flanges.
3. Mount the shower arm
Attach both the wall flanges using the plastic star
plugs and self-tapping screws supplied (these
fasteners may not be appropriate for all wall
materials. If this is the case, other fastening
systems will have to be sourced by the installer).
4. Attach the hose
When fitting the inlet hose, lay the arm against the wall
in the 
The arm will tend to return to this position when not in
use.
38
DRILL 2 HOLES
Ø8x50 DEEP
2275mm ABOVE
THE FLOOR
© Galvin Engineering Pty Ltd
Version 1, 2 June 2022, Page 4of 4
Product Installation Guidelines
Version 1, 2nd June 2022, Page 4of 4
5. Check Shower for operation and leaks
Check the hose is securely connected. Turn on water supply, the shower should now be working. Once
installation is completed and the unit must be tested for any leaks.
To comply with backflow prevention standards, the hand spray must hang at least 55mm above the
floor provide an ‘air-gap’ (See Figure 1). If the hand piece lies on the floor, then an appropriate
backflow prevention device must be installed.
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin
Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties,
express or implied. Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties,
express or implied, including but not limited to the implied warranties of merchantability and fitness for a
particular purpose.

download from www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the
product is free from operational defects in workmanship and materials for the warranty period as shown

replace or repair any defective products manufactured by Galvin Engineering without charge, so long as
the terms 
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive
remedy for breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any
incidental, special or consequential damages, including without limitation, lost profits or the cost of
repairing or replacing other property which is damaged if this product does not work properly, other
costs resulting from labour charges, delays, vandalism, negligence, fouling caused by foreign material,
damage from adverse water conditions, chemical, electrical or any other circumstances over which
Galvin Engineering has no control. This warranty shall be invalidated by any abuse, misuse,
misapplication, improper installation or improper maintenance or alteration of the product.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Water is not flowing or
inconsistant flow
Shower arm is blocked with
debris.
Remove debris from shower arm.