manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Galvin Specialised
  6. •
  7. Mixer
  8. •
  9. Galvin Specialised CliniLever TM-BASCP User manual

Galvin Specialised CliniLever TM-BASCP User manual

Specialised commercial taps and valves
© Galvin Engineering Pty Ltd: 2011
CliniLever® Healthcare Tapware
1. From fixing kit fit 'O'ring (10) into groove in the
underside of mixer body (9), screw studs (11) into
underside of mixer body (9).
2. Apply suitable lubricant to 'O'rings (12). Pass flexible
tail (16) (with red indication) up through deck hole
and install into hole marked 'H' in underside of
mixer body (9). Pass remaining flexible tail (with blue
indication) up through deck hole and install into hole
marked 'C'. Tighten both tails (16) firmly by hand.
3. Place mixer over vanity cut out, fit gasket (13) and
fixing plate (14) over studs (11) then screw on fixing
nuts (15). Position mixer as required then tighten
fixing nuts (15).
4. Connect the flexible tails (16) to the hot and cold
isolating stop taps, taking care that flexible tails
are not kinked, twisted or in tension as they are
tightened
ImportantReplacing Cartridge
TM-BASCP
Important InformationInstallation (Fig 1)
CliniLever® Single Lever Basin Mixer
- All pipework must be thoroughly flushed prior to
installation as foreign materials may block the flow
regulating device and reduce the flow of water.
Note: Aerator insert housing must be retightened
to prevent removal by hand.
- Not suitable for gravity feed systems.
- Mixer is fitted with a 5 L/min flow regulated
aerator insert. This low flow rate may not be
suitable for connection to some Instantaneous
Gas Water Heaters, some Tempering Valves,
some Solar Water Heaters and some
Thermostatic Mixing Valves.
- Check with the manufacturers of these products.
- Isolating stop taps are recommended to be fitted
to the inlet connections.
Pressure & Temperature Requirements.
- Hot and cold water inlet pressures should be equal.
- Inlet pressure range: 150-500 kPa
(Ref. AS/NZS 3500.1 -2003, Clause 3.3.4)
- Maximum hot water temperature : 80°C.
Deck Requirements
- Deck thickness: 45mm maximum
- Tap body hole (in deck): Ø33-35mm
1. Turn off hot and cold water supplies at isolating stop
taps.
2. Remove indicator plug (3). Using 2.5mm allen key
(4) loosen screw (2) and remove handle (1). Remove
cap (5) taking care not to damage the decorative
finish. Unscrew nut (6) then lift out old cartridge (8).
3. Ensure inside face of mixer body (9) is clean. Fit new
cartridge (8) into mixer body, taking care that two
lugs on base of cartridge (8) fit into mating holes in
mixer body (9).
4. Screw on nut (6). Important: Nut (6) should be
tightened to a torque of 12 Nm.
5. Replace cap (5), tightening by hand. Fit handle
(1) taking care that it is pushed fully down, tighten
screw (2) and replace indicator plug (3), position
with red to the left.
6. Turn on isolating stop taps and check operation.
7. To adjust the maximum hot water temperature refer
to the instruction on the next page:- 'Adjusting the
anti-scald stop ring'.
July 2015
Specialised commercial taps and valves
© Galvin Engineering Pty Ltd: 2013 (Issue 07/2015)
CliniLever® Healthcare Tapware
410 Victoria Rd, Malaga, WA 6090
Within Australia: 1300 514 074 Outside Australia: +61 (0)8 9249 5900
Fax: +61 (0)8 9249 5916 Email: [email protected]
www.galvinengineering.com.au
PERTH I SYDNEY I MELBOURNE I BRISBANE I ADELAIDE
ABN: 78 008 719 382
A business unit of
TM-BASCP
As supplied, this mixer delivers full flow hot and cold
water. To use the anti-scald feature adjust the stop ring
as follows:
1. Remove indicator plug (3). Using 2.5mm allen key
(4) loosen screw (2) and remove handle (1). Unscrew
cap (5) taking care not to damage the chrome finish.
2. Using a small screwdriver, carefully remove the red
stop ring (7) and reposition it in an anti-clockwise
direction as required so that the spline teeth in the
stop ring (7) engage with the spilne teeth on the
cartridge (8). As a guide, rotate the stop ring (7) by 1
spline in an anti-clockwise direction. This will restrict
the handle movement in the hot water direction by 8
degrees of rotation. Push the stop ring (7) fully down.
3. Check the hot water temperature with the handle
in the fully open hot water position. If required
adjust the stop ring (7) until a satisfactory hot water
temperature is achieved. Ensure stop ring is fully
pushed down.
4. Replace cap (5), tighten by hand. Fit handle (1)
taking care that it is pushed fully down. Tigthen grub
screw (2) and replace handle plug (3).
Adjusting the Anti-scald Stop Ring (Fig 2)
Replacing Aerator Insert
1. Carefully remove aerator housing (17) from mixer
body (9) taking care not to damage the decorative
finish.
2. Remove seal (19) and aerator insert (18) from aerator
housing. Check that aerator housing is clean and
clean any debris that is blocking the flow.
3. Fit new aerator insert (18) into aerator housing (17)
followed by seal (19) then screw assembly into mixer
body (9) and tighten securely (to prevent removal by
hand).
July 2015

Popular Mixer manuals by other brands

Azden FMX-2 instructions

Azden

Azden FMX-2 instructions

LANDY S-BC Operator's manual

LANDY

LANDY S-BC Operator's manual

Makita UT001G instruction manual

Makita

Makita UT001G instruction manual

Phonic POWERPOD 620 PLUS Service manual

Phonic

Phonic POWERPOD 620 PLUS Service manual

Kogan KAHTNSNDMIX user manual

Kogan

Kogan KAHTNSNDMIX user manual

Topmatic PKM-1800.1BG instruction manual

Topmatic

Topmatic PKM-1800.1BG instruction manual

Mutable Instruments Warps user manual

Mutable Instruments

Mutable Instruments Warps user manual

Fritel CM 2400 manual

Fritel

Fritel CM 2400 manual

B+BTec Diamond 3 MX11 operating manual

B+BTec

B+BTec Diamond 3 MX11 operating manual

Graphite 58G788 instruction manual

Graphite

Graphite 58G788 instruction manual

OPTi RK-0241 operating instructions

OPTi

OPTi RK-0241 operating instructions

Scarlett SC-HM40S01 instruction manual

Scarlett

Scarlett SC-HM40S01 instruction manual

Herdsking SM-2019BG instruction manual

Herdsking

Herdsking SM-2019BG instruction manual

Avantco Equipment 177MIX8GY user manual

Avantco Equipment

Avantco Equipment 177MIX8GY user manual

CONTINENTAL EDISON CY-613A instruction manual

CONTINENTAL EDISON

CONTINENTAL EDISON CY-613A instruction manual

GRASS VALLEY INDIGO HD EXPANSION datasheet

GRASS VALLEY

GRASS VALLEY INDIGO HD EXPANSION datasheet

American Audio Q-2411 User guide and reference manual

American Audio

American Audio Q-2411 User guide and reference manual

Makita UT1305 instruction manual

Makita

Makita UT1305 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.