Electronic Central Tsi Light Manual
1
22
21
03
10
07
06
11
08
13
05
09
04
12
01
02
14
23
16
17
18
20
19
15
LIMIT SWITCH
CONNECTOR INPUT
MOTOR WIRE INPUT
127/220V VOLTAGE
SELECTION SWITCH
ELECTRIC NETWORK INPUT
THERMAL SENSOR
INPUT OF THE MOTOR
FEATURES
1 - Programming Led;
2 - Programming Led;
3 - Selector Key 127/220V ;
4 - Independent opening and closing door buttons (CM: Common (GND) + BTF = Closing Door
Button / Common (GND) + BTA = Opening Door Button) ;
5 - Tamper Sensor;
6 - ARM® micro controller: state-of-the-art 32-bit micro controller with 48Mhz processing;
7 - External Memory: Makes it easy to replace the electronic central without having to
reprogram all the controls and allows up to 511 buttons / controls programmed in the 24(L)
C16 memory;
8 -Heterodyne receiver: Does not lose frequency calibration;
9 -12 VDC auxiliary output max 60mA ;
10 - 2 (two) Limit Switch Connectors: 5 and 3 pin input;
11 - Easy programming of the electronic central through the 7-segment display ;
12 - Encoder: better motor positioning and precision during ramps and stops ;
13 - Communication with Optional 8F board: that aggregates the functions of garage light, lock,
signal and alarm;
14 - Programming buttons: (UP, DOWN, ENTER);
15 - Transformer;
16 - S ( Photocell signal);
17 - Fuse
18 - Electrical power input; 19 - Motor connection (U,V,W); 20 - Thermal relay input;
21 - Motor Led: On = motor on; Off = motor off;
22 - Led TX/RX Blinking: Software communicating OK;
23 - Double command.
Complementary Features
- Arrival ramp adjustment: Electronic deceleration;
- Start ramp adjustment: Acceleration rate;
- Independent speed adjustment for opening and closing;
- Independent ramp adjustment for opening and closing;
- IGBT module with built-in thermal protection (Protects components and engine burning).

On the right side of the buttons, it has a 7-segment display, where it will signal through
numbers and letters what state the menu is in.
STANDBY (AT REST)
Symbolizes open limit switch
(FCA)
Symbolizes closed limit switch
(FCF)
No limit switch triggered
PROGRAMMING
The function options are selected in the MAIN MENU, where it goes from 0 to 9.
TABLE OF ALERTS
NOTE :
The programming buttons are locked, while some
alert is shown.
DOUBLE COMMAND ( CM.DOUBLE ) (7)
When closing the jumper, the opening button and closing button controls are unified and the
electronic central starts to operate with a BTA or BTF command for both opening and closing.
The condominium function (F.Condo) must be off (0).
PHOTOCELL (10)
If the photocell is interrupted while the gate is open, it will prevent any closing command and it
will remain open until the photocell detects no obstacle. During closure, the obstacle detection
via the photocell will stop the motor and reverse the direction to open automatically, regardless
of the reverse function status.
HOW TO NAVIGATE IN THE SETUP MENUS (6)
UP = Increase (+) / DOWN = Decrease (-)
“ENTER” Button: Select function. If the "ENTER" button is pressed for 2 seconds, its operation
will be from ESC, i.e. exit / cancel selection / return to the initial screen.
To navigate between the options use the "UP" or "DOWN" keys and to select an option press
"ENTER."
Once inside the settings screens, if no button is pressed within 13 seconds, the electronic
central returns to standby mode.
CONFIGURING THE ELECTRONIC CENTRAL
The electronic central has 4 "MENU" states.
Example: MAIN MENU
MENU 2
MENU 3
MENU 4.
3 4
DISPLAY
ERROR
a
ENCODER ERROR
b
TAMPER SENSOR
c
THERMAL RELAY
d
TEMPERATURE
SENSOR
MAIN MENU
FUNCTION
MENU 2
FUNCTION
MENU 3
FUNCTION
MENU 4
FUNCTION
--
STANDYBY
1
TX
C
REGISTER
C
CONFIRM
A
DELETE
0-A
DELETE
2
STROKE
C
PROG. STROKE
1-C
START STROKE
A
ADJUST
A
OPENING
c
CONTINUE
F
CLOSING
3
SPEED
A
OPENING
0-9
45 hZ ~180 Hz (15Hz)
F
CLOSURE
0-9
45 hZ ~180 Hz (15Hz)
4
FINAL SPEED
0-9
15 Hz ~ 60Hz (5Hz)
5
RAMP
A
OPENING
0-9
15% ~60% (5%)
F
CLOSURE
0-9
15% ~60% (5%)
6
PAUSE
0-9
OFF~90SEC(10SEC)
7
FUNCTIONS
0-1
REVERSAL
0-1
CONDOMINIUM F.
0-1
DIRECTION
8
RATE
A
ACCELERATION
0-9
30Hz~120Hz(10Hz/S)
d
DECELERATION
0-9
30Hz~120Hz(10Hz/S)
9
STARTING TIME
0-9
OFF ~900Ms (100Ms)
0
RESET
1-F
FACTORY RESET

MAIN MENU
To navigate through the options you must enter the main menu. When the display is in standby
press the "ENTER" button once to enter the menu. Use the "UP" and "DOWN" buttons to
choose functions from 0 to 9.
The led (LD_2) will light up symbolizing that it is inside the menu.
( 1 ) (TX) Press the "ENTER" button to access the "TX" function.
Within the "TX" option you have two more options : Register and Delete
Using the "UP" or "DOWN" buttons, choose “C” to register or "A" to delete.
1.1 (C) REGISTER: After choosing the letter "C", click on the "ENTER" button to enter
the function " REGISTER".
1.1.1. Already in the function, the display will clear. Press the button of the control you want to
register, the letter "C" will appear, signaling that you have identified a control, press and release
the "ENTER" button, then the letter "P" will appear confirming the recording. The electronic
central will wait for new buttons to be registered, or to exit, press
"ENTER" once or wait 10 seconds
1.2(A) DELETE: After choosing the letter " A", click the "ENTER" button to enter the
function " DELETE".
1.2.1 Already in the function, press and release the "UP" button until the display shows the
letter " A". Press the button
“ENTER” to confirm.
The led(LD_2) will flash until the electronic central has finished erasing the memory.
After finishing, the panel will return to the main menu.
(2)
STROKE = (First activation of the motor)
It’s necessary to program the stroke before any activation to avoid damage to the electronic
central and gate.
Press the "ENTER" button to access the "STROKE" function.
Within the "STROKE" you have two more options: Program Stroke and Adjust
Using the "UP" or "DOWN" buttons to navigate until the letters "C” for Program Stroke or "A” for
Adjustment appear on the display.
2.1(C) PROGRAM STROKE: After choosing the letter " C ", click the "ENTER" button to
enter the function
“PROGRAM STROKE”.
2.1.1. Already in the function, press the "UP" or "DOWN" button until the letter "C" appears in
the display. Press the button
“ENTER” for the engine to start moving and look for the limit switch.
NOTE: First operation must be the closure, otherwise the wires must be reversed
of the “U” motor through “W” and also the limit switch. Then remove and replace the jumper of
the "TAMPER".
When the limit switch is found, the letter “c” will appear on the display, which means to
continue, press and release the “ENTER” again for the engine to run to the other limit switch,
then the letter “P” will appear on the display meaning that the stroke has been programmed
correctly.
2.2 (A) ADJUST: It serves to fix the ends of the opening and closing limit switches. After
choosing the letter "a", click the "ENTER" button to enter the "ADJUSTMENT" function.
2.2.1.Already in the function with the "UP" button pressed, the automator moves in the
opening direction, and the "DOWN" button in the closing direction.
(3)
(SPEED)
Maximum speed achieved during opening or closing. Press the "ENTER" button to access the
"SPEED" function.
Using the "UP" or "DOWN" buttons, choose " A " for Opening or " F " for Closing.
3.1(A) OPENING: After choosing the letter " A", click the "ENTER" button to enter the "OPEN"
function.
Already in the function, press the "UP" or "DOWN" button to increase or decrease the motor
speed from 45Hz to 180Hz, "0" = 45Hz, "9" = 180Hz (Increase and decrease of 15Hz).
3.2 (F) CLOSURE: After choosing the letter "F", click the "ENTER" button to enter the
"CLOSE" function.
Already in the function, press the "UP" or "DOWN" button to increase or decrease the motor
speed from 45Hz to 180Hz, "0" = 45Hz, "9" = 180Hz (Increase and decrease of 15Hz).
(4)
(FINAL SPEED)
Motor speed in hertz (Hz) during the course learning and after the deceleration of the arrival
near the end of stroke.
Press the "ENTER" button to access the "FINAL SPEED" function.
Within the "FINAL SPEED " option you have 10 adjustment levels. Press the “UP” or
“DOWN” key to increase or decrease the final speed, which goes from 15Hz to 60Hz, "0" =
15Hz, "9" = 60Hz (Increase and decrease of 5Hz).
(5)
(RAMP)
Distance from the stop where the motor will slow down. The values refer to the percentage of
the course learned.
Press the "ENTER" button to access the " RAMP" function.
Using the "UP" or "DOWN" buttons, choose " A " for Opening or " F " for Closing.
5.1(A) OPENING: After choosing the letter "A", click the "ENTER" button to enter the function
“OPENING”.
Already in function, press the "UP" or "DOWN" button to increase or decrease the size of the
ramp that the motor will run, from 15% to 60%, "0" = 15%, "9" = 60% (Increase and decrease
of 5Hz).
5.2 (F) CLOSURE: After choosing the letter "F", click the "ENTER" button to enter the in the
"CLOSURE" function.
5 6

Already in the function, press the "UP" or "DOWN" key to increase or decrease the ramp size
that the motor will execute, from 15% to 60%, "0" = 15%, "9" = 60% (Increase and decrease of
5Hz).
(6)
(PAUSE)
Time that the gate will stay open before closing automatically. If the pause time is over and the
photocell or loop is active, the electronic central will not perform the closing, it will wait to
release the photocell or loop, wait 1 second and only then will execute the closure.
Within the "PAUSE" option there are ten parameters. Each display number adds 10 seconds.
“0” = OFF, “9” = 90 seconds.
(7)
(FUNCTIONS)
Press the “ENTER” button to access “REVERSE FUNCTION”
If pressed again “CONDOMINIUM FUNCTION”
If pressed again “DIRECTION FUNCTION”
Each function when enabled or disabled causes the electronic central to exit from
programming mode, returning to standby mode.
Using the "UP" or "DOWN" buttons, choose " 0 or 1 ", "1" being enabled and "0" disabled
7.1 REVERSION:
With the reversing function enabled "1", the electronic central ignores commands during opening
and closing and only needs one command to stop and reverse the motor to the opening direction
again.
7.2 (F) CONDOMINIUM FUNCTION
With the condominium function enabled "1", the electronic central works as follows:
The “DOUBLE CM” jumper must be open. In the loop function the plate needs a button
command between CM and BTA to start the full opening of the gate and a command between
CM and BTF to execute the closing. The command between CM and BTF must proceed as
follows:
-Loop state 1: Close CM with BTF = keep the gate open and ignore remote control and
automatic closing commands (pause).
-Loop state 2: Open CM with BTF = it will wait 1 second and start closing.
-Loop state 3: If during the closing movement the CM is closed with BTF = it will revert the
motor to the opening direction. Once opened if the CM with BTF remains closed the operating
logic returns to loop state 1.
If during opening and within loop state 3 and the CM and BTF command is released,
the electronic central will finish the opening and change to loop state 2.
7.3 DIRECTION:
The electronic central leaves the factory with the limit switch and motor connected to act in the same
direction of operation. To reverse the operating direction, simply enable the "1" direction
function, thus not having to disconnect the motor wires and the limit switch.
7
(8) (RATE)
Press the "
ENTER" button to access the "RATE" function.
Using the "
UP" or "DOWN" buttons, choose “A” for Acceleration or "D" for Deceleration.
8.1 (A) ACCELERATION:
After choosing the letter "a", click the "ENTER" button to enter the
"ACCELERATION
" function.
Already in the function, press the "
UP" or "DOWN" key to increase or decrease the acceleration that
the motor will execute, which goes from 30Hz/s to 120Hz/s "0" = 30Hz/s, "9" = 120Hz/s (10 Hz
increase and decrease).
8.1 (d) DECELERATION:
After choosing the letter "d", click the "ENTER" button to enter the
"DECELERATION
" function.
In the function, press the "
UP" or "DOWN" key to increase or decrease the deceleration that the engine
will execute, which goes from 60Hz/s to 150Hz/s "0" = 60Hz/s, "9" = 150Hz/s (increase and decrease of
10 Hz).
(9) (STARTING TIME)
This function assists in the starting of the gate (opening and closing) so that the machine starts in slow
mode, the values can be adjusted from 0 to 9 where each increment is equivalent to 100 milliseconds. This
function is very useful for heavy gates as it allows the weight of the inertia to be removed in a slow manner,
avoiding bumps and even initial screwing, after the gate is already working, the center assumes the
adjusted speed and ramp values.
Press the
"ENTER" button to access the "STARTING TIME" function. Within
the "
STARTING TIME" option there are 10 levels of adjustments.
Already in the function, press the "
UP" or "DOWN" button to increase or decrease the starting time the
motor will run. Each display number adds 100ms. “0” = OFF, “9” = 900ms
(0) (RESET)
Press the "
ENTER" button to access the "RESET" function.
Use the "
UP" or "DOWN" buttons to navigate until the letter " F" appears in the
display. Press the “
ENTER” button
After pressing, the center will start the "
RESET" process, returning to the original factory settings. The
letter "
P" will appear in the display, symbolizing "FACTORY STANDARD", then the center exits the
programming mode.
When doing a full reset on the board only the settings such as speeds and ramps will be lost. The stroke
and the registered controls will not be changed.
The maximum consumption of equipment connected to the center should not exceed 60mA. * with risk of damaging the
ATTENTION
ATTENTION
Do not connect to motor wires, accessories such as lock, signalling, garage light or photocell, this
type of connection causes the product to burn. For these cases it is necessary to use the optional module 8F *not
included in the kit*.
It is mandatory to use limit switches (magnets), without the same risk of burning and malfunctioning of the
product.
ATTENTION
Use of safety photocell *not included in kit* is mandatory
ATTENTION
8

WARRANTY TERM
The GAREN AUTOMAÇÃO S/A manufacturing equipment, located at Rua São Paulo, 760, Vila Araceli,
Garça- SP, CNPJ: 13.246.724/0001-61, IE: acquired by Vs., was tested and approved by the Engineering,
Quality and Production departments. We guarantee this product against defects in design, manufacture and
assembly and/or jointly as a result of defects in the quality of the material that make it unsuitable or improper
for consumption for the legal period of 90 (ninety) days from the date of purchase, provided that the
guidelines for installation, use and care described in the manual are observed. In the event of a defect,
within the warranty period, our responsibility is restricted to the repair or replacement of the device.
Out of respect for the consumer and as a consequence of the credibility and trust placed in our
products, we add 275 days to the legal period, totaling 1 (one) year from the date of proven purchase. In this
additional period of 275 days, only visits and transport will be charged. In locations where there is no
authorized technical assistance, the costs of transporting the equipment and/or technician are the
responsibility of the consumer. Replacement or repair of the equipment does not extend the warranty
period.
This warranty loses its effect if the product is not used under normal conditions; is not used for its
intended purpose; suffers any damage caused by accidents or agents of nature such as lightning, floods,
landslides, etc.; is installed in an improper electrical network or in disagreement with the instructions in the
technical manual; suffers damage caused by accessories or equipment installed in the product.
Recommendations
We recommend the installation and maintenance of the equipment through authorized technical service.
Only it is authorized to open, remove, replace parts or components, as well as repair defects covered by the
warranty. Installation and repairs carried out by unauthorized persons will result in automatic exclusion from
the warranty.
Buyer:
Address:
City: Zip Code:
Reseller:
Date of the Purchase: Phone:
Product identification:
Garen Automação S/A
CNPJ: 13.246.724/0001-61
Rua São Paulo, 760 - Vila Araceli
Zip Code: 17400-000 - Garça - São Paulo - Brasil
garen.com.br
BRAZILIAN IND.
FEITO NO BRASIL
HECHO EN BRASIL
MADE IN BRAZIL
Authorized distributor:
NOTES
9

Garen Automação S/A
CNPJ: 13.246.724/0001-61
Rua São Paulo, 760 - Vila Araceli
Zip Code: 17400-000 - Garça - São Paulo - Brasil
garen.com.br
BRAZILIAN IND.
FEITO NO BRASIL
HECHO EN BRASIL
MADE IN BRAZIL
Table of contents
Popular Engine manuals by other brands

Deprat
Deprat TEMPO PLUS MIXTE 050TPM008 installation instructions

Mercedes-Benz
Mercedes-Benz OM 457 LA operating instructions

Hitachi
Hitachi SH7750 series Programming manual

Assun
Assun AM-PI45115AN Series product manual

Northern Lights
Northern Lights M944T Operator's manual

Maco
Maco HAUTAU SA 650N Mounting and operating instructions