Garland P10GMSFE-5 User manual

User Guide
P10GMSFE-5
P10GMSFE-6
P10GMSFE-7
P10GMSFE-8
P10GMSFE-9
P10GSSFE-5
P10GSSFE-6
P10GSSFE-7
P10GSSFE-8
P10GSSFE-9
01/2023
Release Version: 4.22.1
1

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Copyright © 2022 Garland Technology, LLC. All rights reserved.
No part of this document may be reproduced in any form or by any means without prior written permission of
Garland Technology, LLC.
The Garland Technology trademarks, service marks ("Marks") and other Garland Technology trademarks are the
property of Garland Technology, LLC. PacketMAX Series products of marks are trademarks or registered
trademarks of Garland Technology, LLC. You are not permitted to use these Marks without the prior written
consent of Garland Technology.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Garland
Technology and the customer. All or part of the products, services and features described in this document may
not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
2

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Table of Contents (click topic to go directly to the page)
1. Dashboard 6
Span Mode 6
LED Indications 6
Breakout 7
LED Indications 7
Filter 8
LED Indications 8
Aggregate 9
LED Indications 9
Filter Tap 10
LED Indications 10
2. System 11
System Info 12
General 12
Admin 12
Users 12
Groups 13
Authentication 13
Local Authentication Disable 14
Local Authentication Enable 14
TACACS Primary Authentication 14
TACACS Test 14
TACACS Ping Test 14
TACACS Secondary Authentication 15
TACACS Test 15
TACACS Ping Test 15
Network Settings 15
IPv4 / Disable 16
IPv4 Enable 16
IPv6 Enable 16
IPv6 Disable 16
Add SSL Certificate 17
Disable Using Uploaded SSL Certificate 17
Date & Time 18
Timezone 18
UTC 18
Manually Set Date & Time 18
NTP No Authentication (Symmetric) 18
NTP Authentication (Symmetric) 19
Syslog 19
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
3

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Syslog Test 20
SNMP 20
SNMP Test 21
Export Configuration 21
Import Configuration 21
Software Upgrade 22
Reboot 22
3. Span Mode 23
4. Breakout Mode 24
5. Filter Mode 25
Packet Broker 26
Filter Templates 27
Config Map 28
Ingress 28
Filters 29
Egress 30
Config Map Save 30
Modify a Config Map 30
Config Map Statistics 31
Delete Config Map 31
Config Map Priority 32
Method 1 32
Method 2 32
Enable/Disable Config Map 33
Disable Config Map 33
Enable Config Map 33
6. Aggregate Mode 34
7. Filter Tap Mode 35
Packet Broker 36
Filter Templates 37
Config Maps 38
Filter 39
Egress 40
Config Map Save 40
Modify a Config Map 41
Delete Config Map 42
Method 1 43
Method 2 43
Enable/Disable Config Map 43
Disable Config Map 44
Enable Config Map 44
8. Port Info 44
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
4

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
1. Dashboard
This section provides an overview of the dashboard architectures and LED indications. The port
assignments and LED indications will change on the dashboard based on the mode configured.
The dashboard provides an exact detail of the unit’s faceplate. However, some LED indications that
are displayed on the faceplate, are not displayed on the dashboard. The P10GXXFE-X supports multiple
modes of operation, Span, Breakout, Filter, Aggregate and Filter Tap.
Span Mode
LED Indications
Port 1 L/A1 Network Port Link/Activity LED
Port 2 L/A2 Span Port Link/Activity LED
BP N/A
Port 3 L/A Span Port Link/Activity LED
Port 3 H/M N/A
Port 4 L/A Span Port Link/Activity LED
Port 4 H/M N/A
* The L/A1, L/A2, Port 3 L/A and Port 4 L/A LEDs only indicate link in the GUI.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
6

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Breakout
LED Indications
Port 1 L/A1 Network Port Link/Activity LED
Port 2 L/A2 Network Port Link/Activity LED
BP N/A
Port 3 L/A Breakout Port Link/Activity LED
Port 3 H/M N/A
Port 4 L/A Breakout Port Link/Activity LED
Port 4 H/M N/A
* The L/A1, L/A2, Port 3 L/A and Port 4 L/A LEDs only indicate link in the GUI.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
7

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Filter
LED Indications
Port 1 L/A1 Filter Port Link/Activity LED
Port 2 L/A2 Filter Port Link/Activity LED
BP N/A
Port 3 L/A Filter Port Link/Activity LED
Port 3 H/M N/A
Port 4 L/A Filter Port Link/Activity LED
Port 4 H/M N/A
* The L/A1, L/A2, Port 3 L/A and Port 4 L/A LEDs only indicate link in the GUI.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
8

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Aggregate
LED Indications
Port 1 L/A1 Network Port Link/Activity LED
Port 2 L/A2 Network Port Link/Activity LED
BP N/A
Port 3 L/A Aggregate Port Link/Activity LED
Port 3 H/M N/A
Port 4 L/A Aggregate Port Link/Activity LED
Port 4 H/M N/A
* The L/A1, L/A2, Port 3 L/A and Port 4 L/A LEDs only indicate link in the GUI.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
9

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Filter Tap
LED Indications
Port 1 L/A1 Network Port Link/Activity LED
Port 2 L/A2 Network Port Link/Activity LED
BP N/A
Port 3 L/A Breakout/Aggregate Port Link/Activity LED
Port 3 H/M N/A
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
10

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
Port 4 L/A Breakout/Aggregate Port Link/Activity LED
Port 4 H/M N/A
* The L/A1, L/A2, Port 3 L/A and Port 4 L/A LEDs only indicate link in the GUI.
2. System
The following configuration options may be displayed, modified, enabled or disabled under the System
panel.
System Info SNMP
General Export Configuration
Admin Import Configuration
Network Settings Software Upgrade
Date & Time Reboot
Syslog
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
11

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
1. Select System on the Dashboard Menu bar.
The System panel will be displayed. The system configuration options will be displayed on the
left side of the panel.
System Info
The System Information panel displays the following.
Chassis Name Chassis Model Chassis Serial Number
MAC Address Software Version
1. Select System Info.
The System Information panel will be displayed.
General
The following configuration options may be displayed or modified.
Chassis Name
Key Press Timeout
1. Select General.
The General System Settings panel will be displayed.
2. Select Edit Configuration.
3. Enter the desired Chassis Name.
4. Enter the desired Key Press Timeout.
5. Select Save to save updates.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
12

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
6. Select Cancel to return to the General System Settings panel.
Admin
The following configuration options may be displayed, modified, enabled or disabled.
Users
Groups
Authentication
Local
TACACS Primary
TACACS Secondary
1. Select Admin.
The Admin Settings panel will displayed.
Users
The default user is “admin”. Changes to the default user “admin” are allowed. However, the “admin”
user may not be deleted. Users displayed on the Admin Settings panel are for local authentication
only, not used for TACACS.
1. Select Users + to create a new user.
The Create New User panel will be displayed.
2. Enter the Username.
3. Enter the Password.
4. Select the group for the user.
5. Select Save to save updates.
The new user will be displayed on the Admin Settings panel.
6. Select Cancel to return to the Admin Settings panel.
7. Edit the username, password or assigned group by selecting the pencil.
8. Delete the user by selecting the Red X.
Groups
The group defines the authorization for a user or group of users. A group may be used for local
or TACACS authorization. In Use “true” means that there is at least one local user assigned to
the group. If a group is used by TACACS, the In Use will indicate “false”. There are three default
groups, admin, OPER and NOC. All three groups may be modified, however only the OPER and
NOC groups may be deleted.
1. Select Groups + to create a new group.
The Create New Group panel will be displayed.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
13

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
2. Enter the Group Name.
3. Select the desired privileges.
4. Select Save to save updates.
The new group will be displayed on the Admin Settings panel.
5. Select Cancel to return to the Admin Settings panel.
6. Modify the group privileges by selecting the pencil.
7. Deleted the group by selecting the Red X.
If a group has at least one user assigned it cannot be deleted.
Authentication
Two authentication options are supported, local or TACACS. TACACS authentication supports two
options, primary and secondary. The TACACS primary and secondary options may be enabled or
disabled independently. Local or TACACS authentication may be enabled or disabled independently,
however, at least one option must be enabled. The TACACS primary or secondary function supports
IPv4 only, IPv6 is not supported.
1. Select Authentication Settings.
The Authentication Settings panel will be displayed. Local authentication is enabled by default.
Local Authentication Disable
1. Deselect Local Authentication.
Local authentication may only be disabled provided that TACACS authentication, primary
or secondary has previously been enabled.
2. Select Save.
Local Authentication Enable
1. Select Local Authentication.
2. Select Save.
TACACS Primary Authentication
1. Select Enable Primary.
The TACACS Primary panel will be displayed.
2. Enter the IP Address, IPv4 or IPv6.
3. Enter the Secret Word, (optional).
4. Select Save to save updates.
5. Select Cancel to return the Admin Settings panel.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
14

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
TACACS Test
This option may be used to verify the authentication of a TACACS user, password and
authorization group. The TACACS Test option will be active only if TACACS authentication
has previously been enabled.
1. Select TACACS Test.
The TACACS Test panel will appear.
2. Select Primary.
3. Enter the Username.
4. Enter the Password.
5. Select Test.
The GUI will display the results of the test, “Authentication Test Successful”. As well as
messages for “authentication:Success”, authorization:Success” and
“authorization:group:abcdef.
TACACS Ping Test
This option may be used to verify the network connectivity from the unit to the TACACS server.
The TACACS Ping option will be active only if TACACS authentication has been previously enabled.
1. Select TACACS 1 Ping.
The GUI will display the results of the ping, “TACACS 1 Ping Successful”.
TACACS Secondary Authentication
1. Select Enable Secondary.
The TACACS Secondary panel will be displayed.
2. Enter the IP Address, IPv4 or IPv6.
3. Enter the Secret Word, (optional).
4. Select Save to save updates.
5. Select Cancel to return the Admin Settings panel.
TACACS Test
This option may be used to verify the authentication of a TACACS user, password and
authorization group. The TACACS Test option will be active only if TACACS authentication
has previously been enabled.
1. Select TACACS Test.
The TACACS Test panel will appear.
2. Select Secondary.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
15

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
3. Enter the Username.
4. Enter the Password.
5. Select Test.
The GUI will display the results of the test, “Authentication Test Successful”. As well as
messages for “authentication:Success”, authorization:Success” and
“authorization:group:abcdef.
TACACS Ping Test
This option may be used to verify the network connectivity from the unit to the TACACS server.
The TACACS Ping option will be active only if TACACS authentication has been previously enabled.
1. Select TACACS 2 Ping.
The GUI will display the results of the ping, “TACACS 2 Ping Successful”.
Network Settings
Upon the initial turn up via the serial interface the IPv4 address, IPv4 gateway, IPv6 address and IPv6
gateway may have been already established. The IPv4 and IPv6 management interfaces may be
enabled or disabled independently as well as both enabled or disabled simultaneously. If the IPv4
and IPv6 management interfaces are disabled simultaneously, access is only allowed via the serial
interface. Any modifications made to any setting option will cause GUI disruption for about 60 seconds.
Also note that modifying the management interfaces may cause network disruption if prior consideration
and planning have not been performed.
The default system network configurations are as follows:
IPv4 enabled
IPv4 address 10.10.10.200
IPv4 gateway 10.10.10.1
IPv6 is disabled.
Via the GUI, the following options may be displayed, modified, enabled or disabled.
IPv4 Enable/Disable IPv4 Address IPv4 Gateway
IPv6 Enable/Disable IPv6 Address IPv6 Gateway
SSL Certificate Loaded
Using Uploaded SSL Certificate
1. Select Network Settings.
The Network Settings panel will be displayed with the current configuration.
IPv4 / Disable
1. Deselect Enable IPv4.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
16

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
2. Select Save.
If the IPv6 management interface has not been enabled the GUI will display a
message “Disabling IPv4 and IPv6, GUI will disconnect. Are you sure?
3. Select OK.
IPv4 Enable
1. Select Enable IPv4.
2. Enter the desired Address.
3. Enter the desired Gateway.
4. Select Save.
IPv6 Enable
1. Select Enable IPv6.
2. Enter the desired Address.
3. Enter the desired Gateway.
4. Select Save.
IPv6 Disable
1. Deselect Enable IPv6.
2. Select Save.
If the IPv4 management interface has not been enabled the GUI will display a
message “Disabling IPv4 and IPv6, GUI will disconnect. Are you sure?
3. Select OK.
Add SSL Certificate
Uploading a custom SSL certificate involves two files. The cert.pem file and key.pem file. The unit will
validate these files during the upload. If the files do not match or one of the files are corrupted the unit will
abort the upload.
1. Select Add SSL Certificate.
The Select Certificate and Select Key File panel will appear.
2. Select Choose File for Select Certificate.
3. Select the desired cert.pem file.
4. Select Open.
5. Select the Choose File for Select Key File.
6. Select the desired key.pem file.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
17

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
7. Select Open.
8. Select Upload.
The GUI message will be displayed, “Please wait. Browser will refresh after 90 seconds”.
9. Verify SSL Certificate Loaded “true”.
10. Verify Using Uploaded SSL Certificate “true”.
Disable Using Uploaded SSL Certificate
1. Select Edit Settings.
2. Deselect Using Uploaded SSL Certificate.
3. Select Save.
The GUI message will be displayed,”Saved Settings. Changes will cause network
connectivity disruption for about 60 seconds”.
4. Refresh Browser.
5. Verify SSL Certificate Loaded “true”.
6. Verify Using Uploaded SSL Certificate “false”.
Date & Time
The following configuration options may be displayed, modified, enabled or disabled.
Timezone
UTC
NTP No Authentication (Symmetric)
NTP Authentication (Symmetric)
Time
Date
1. Select Date & Time.
The Date & Time Settings panel will be displayed.
Timezone
1. Select Edit Settings.
2. Select the desired Timezone using the pull down panel.
3. Select Save.
4. Select Cancel to return to the Date & Time Settings panel.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
18

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
UTC
1. Select Edit Settings.
2. Select the desired UTC using the pull down panel.
3. Select Save.
4. Select Cancel to return to the Date & Time Settings panel.
Manually Set Date & Time
1. Select Edit Settings.
2. Enter the Hours or use the up/down arrows to select.
3. Enter the Minutes or use the up/down arrows to select.
4. Enter the Date, MM/DD/YYYY or use the calendar to select.
5. Select Save.
6. Select Cancel to return to the Date & Time Settings panel.
NTP No Authentication (Symmetric)
The system supports an IPv4 or IPv6 address for NTP timing. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
1. Select Edit Settings.
2. Select NTP timing.
3. Enter the IPv4 or IPv6 Address.
4. Verify Authenticate, None.
5. Select Save.
The NTP Status will display “syncing”. Eventually the NTP Status will display “Synced”.
This can take several minutes.
6. Select Cancel to return to the Date & Time Settings panel.
NTP Authentication (Symmetric)
The system supports an IPv4 or IPv6 address for NTP timing. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
1. Select Edit Settings.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
19

User Guide
XtraTAP | P10GxxFE-X | 4.22.1
2. Select NTP timing.
3. Enter the IPv4 or IPv6 Address.
4. Select Authenticate, Symmetric.
5. Select Encryption Type, (MD5, SHA1, SHA224, SHA256, SHA384, SHA512)
6. Enter the Key Number.
7. Enter the Key.
8. Select Save.
The NTP Status will display “syncing”. Eventually the NTP Status will display “Synced”.
This can take several minutes.
9. Select Cancel to return to the Date & Time Settings panel.
Syslog
The system supports an IPv4 or IPv6 address for Syslog. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
1. Select Syslog.
The Syslog Configuration panel will be displayed.
2. Select Edit Settings.
3. Select Enable Syslog Config.
4. Enable Unit ID, (optional).
5. Enter the Unit ID, (optional).
6. Enter the IPv4 or IPv6 Address.
7. Enter the desired UDP Port Number or use the default, 514.
8. Select Save.
9. Select Cancel to return the Syslog Configuration panel.
Syslog Test
1. Select Syslog Test.
The GUI message will be displayed,”Syslog Test Successful!”.
2. Verify the Syslog Test Message on the Syslog server.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.
20
This manual suits for next models
9
Table of contents
Other Garland Switch manuals
Popular Switch manuals by other brands

THOMSON
THOMSON TTN-BAS-0808CP installation manual

Alcatel-Lucent
Alcatel-Lucent OmniSwitch 6855-24 Hardware user's guide

sourcetec
sourcetec UNO installation guide

Vega
Vega VEGAPOINT 31 operating instructions

SMC Networks
SMC Networks 8748L2 FICHE Management guide

D-Link
D-Link DES-1228 - Web Smart Switch manual