Multi Gas Clip User’s Manual
V1.7 Portable gas detectors you can count on. 3 of 16
Warnings Statements/Avertisseement
Do not substitute components as this may interfere with the intrinsic safety of the device.
Ne remplacez pas les composants car cela pourrait interférer avec la sécurité intrinsèque de l'appareil.
DO NOT substitute any other battery type than specified and supplied by Gas Clip Technologies.
Only use Gas Clip Technologies parts in the detector. Non approved parts will void the warranty and are
considered unsafe.
Before daily use check that all sensor and audio ports are clear of any obstructions i.e. debris or blockage
The detector contains a lithium battery that must be disposed of by a qualified recycler. Check local
regulations for proper disposal
DO NOT charge the instrument in a hazardous location.
DO NOT use IR communications when an explosive atmosphere may be present.
If you suspect any malfunction or have any technical problems, contact GCT at 877-525-0808
Warning: The battery may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat
above 100°C (212°F), or incinerate. Contact Gas Clip Technologies for replacement instructions. Use of
another battery may present a risk of fire or explosion.
DO NOT charge the instrument in temperatures above or below the specified range of 0°C to 40°C
Keep new and used batteries away from children
DO NOT expose the detector to known combustible sensor poisons such as but not limited to alcohol and
citrus based cleaners, silicones, lead compounds (eg: tetraethyl lead), sulfur compounds, phosphorus,
halogenated hydrocarbons, and aerosols
If suspected combustible sensor poisoning has occurred, recheck the instrument (both calibrate and bump
test).
The detector should be bump tested before use with a known concentration of methane to confirm its ability
to respond to gas. Calibrate the detector if the readings are not within the specified limits.
Le détecteur doit être testé avant utilisation bosse avec une concentration connue de méthane pour
confirmer sa capacité à répondre à gaz. Calibrer le détecteur si les relevés ne sont pas dans les limites
spécifiées.
Any rapid up-scale reading followed by a declining or erratic reading may indicate a gas concentration
beyond upper scale limit which may be hazardous.
Toute rapide haut de gamme lecture suivie d'une lecture erratique baisse ou peut indiquer une concentration
de gaz supérieure à la limite supérieure de l'échelle qui peut être dangereux.
Strong Electromagnetic Interference (EMI) may cause incorrect operaions.
Only the combustible gas detection portion of this instrument has been assessed for performance by CSA
International.
READ FIRST BEFORE OPERATION
Gas Clip Technologies (GCT) Multi Gas Clip (MGC) detectors are personal safety devices
designed to detect the presence of specific toxic gases Carbon Monoxide (CO), Hydrogen
Sulfide (H2S), Oxygen (O2), and Combustible gases/Lower Explosive Limit (LEL). Ensure you
have been properly trained on the use of the equipment and appropriate actions in the
event of an alarm condition.