LUCE AMICA
infrared detector for light switching
INTRODUCTION
LUCE AMICA 44..068/3F is a volumetric passive infrared sensor detecting
people's presence; it is provided with a triac output, suitable for lamp swit-
ching-on or load actuation. The detecting component is made up of a
pyroelectric sensor and a Fresnel lens. The control device is equipped with
a twilight sensor which makes the output operate only when the room light
drops below the preset threshold. After a detection, the output is activated
for an adjustable time by means of a special timer.
The front panel is provided with:
a) a Fresnel lens
b) a twilight sensor transparent win-
dow
Pt1 Light switching-on time adjust-
ment
Pt2 twilight threshold adjustment
It is installed onto 1 System 44 modu-
le. From the mechanical point of view,
it is compatible with all System 44
components and can also be installed
onto flush-mounting round boxes.
TECHNICAL DATA
•Power supply: 230 Vac
•Allowed variation: 198 to 253 Vac
•Mains frequency: 50 - 60 Hz.
•Max current demand: 12 mA at 230 Vac
•Reference temperature and relative humidity: 25°C – RH 65%
•Room temperature range: 0°C to +40°C
•Max relative humidity: 90% at 35°C
•Loads to be controlled with alternate current:
– Resistive load (cosϕ= 1): 1A max at 230 Vac
– Inductive load: 25÷200VA
– Filament lamps: 25÷200W
– Fluorescent lamps: 25÷200W (power factor corrected in parallel).
b
+
-
a
Pt2 Pt1
-
+
Note: not advisable for energy conservation lamps control.
•Load trigging time: 20 s to 5 min (20% tolerance)
•Twilight threshold adjustment: 10 lx to 7.000 lx.
•Overall dimensions: nr. 1 System 44 module
•Protection degree: IP41
STANDARD REFERENCES
CEI EN 60669-2-1 "Circuit breakers for domestic fixed installations and
similar uses"
COVERING DIAGRAM
(fig. 1)
a) Plan view b) Side view
OPERATING DESCRIPTION
Initial test
On connecting the device to the power supply, it is affected by the following
conditions:
• Lamp test: output 0.5s OFF and then 30s ON
• Covering test: Under this condition the detector can activate the load
independently from the room light level. At every detection the load is
controlled for 4 s. (the thresholds preset from Pt1 and Pt2 are not deter-
minant). The test duration is fixed and corresponds to 180s.approx.
Operation
The sensor is enabled to switch lights on when detecting any movement at
a temperature different from the one of the scanned area only if the room
light is lower than the one set by the special potentiometer (Pt2).
Once the load has been turned on, it remains in such a condition for the
time preset by the special potentiometer (Pt1). If anybody walks in front of
the detector during the load activation time, the timing in progress is auto-
matically restored by starting from zero, without interrupting the load on
restoring.
NOTE: to avoid any possible irregular operation due to the short distance
between the detector and the controlled lamp, we recommend to proceed as
follows:
•for 2 seconds from the lamp switching-off (OFF) the detector is "masked"
(does not operate);
•likewise, during the ON period the twilight threshold (b) is masked.
Do not install the device next to heat (convectors) and light sources.
We recommend likewise not to install the device near components subject
to heat (light dimmers, relays, etc..).
APPLICATION DIAGRAMS
•Installation to control the load from one detecting spot
(Fig. 2)
•Installation to control the load from two or more detecting spots
(Fig. 3).
150°
m
1,2 m
1051,5 8
Figure 1
Figure 2
Figure 3
a)
b)
N
L
L1
L
N
230Vca
N
L
L1
L
F
C.516 - 04 - 201009
N
L
L1
L
N
230Vac
L
F
L: load 25÷200W
F: fuse type T 1 H 250V
Legend figures 2 / 3
IMPORTANT NOTES:
• Products should be sold in their original packaging. Otherwise, the retailer and/or
installer is obliged to follow, as well as to communicate to the user, the instructions
for use which are supplied with the product and/or are published on the website
www.ave.it as well as in the current product catalog.
• AVE products are installation products
• Products must be installed by trained professionals in compliance with the
installation regulations
• Once the product is unpacked, make sure that the appliance is undamaged. Do
not use the appliance if there is any doubt, but contact a qualified technician
• Even before unpacking, the appliance should be handled with care and stored in
a dry place at temperatures between –5°C and +40°C
• Before carrying out any maintenance on the appliance, cut off the mains power
• Special attention should be paid to the preparation of the cable terminals to be
inserted into the appliance terminals so as to maintain sufficient isolation distance
between contacts
• When tightening the terminal screws, special care should be taken to avoid
overheating which could start a fire or damage the cables.
• The product must be used in dry, dust-free areas
• Suitable products must be used in any other conditions
• There is a risk of electric shock or malfunction of the device if not handled
properly.
• Install products and accessories according to the prescriptions in the catalogue
and the instructions sheet and in compliance with specific standards and rules
• Warranty certificate for a specific product, which specifies the warranty period
and conditions in accordance with local regulations, is issued by the seller at the
moment of sale of product
The manufacturer's warranty: The 5 year warranty applies only
to damaged or malfunctioning products caused by manufacturer’s
negligence, taking into account the rights and obligations
prescribed by law (art. 1490, 1512 C.C., DL 24/2002, Directive
1999/44/CE, art. 1519 C.C.). The defect must be notified within 2
month from the date it was discovered. Five years are intended
from the date of delivery of the product to the final customer.

Other AVE Security Sensor manuals

AVE AF964R-DB User manual

AVE

AVE AF964R-DB User manual

AVE LUCE AMICA 44 068/3F Series User manual

AVE

AVE LUCE AMICA 44 068/3F Series User manual

AVE Domina Smart AF964R-DB User manual

AVE

AVE Domina Smart AF964R-DB User manual

AVE domina AF968R-DBN User manual

AVE

AVE domina AF968R-DBN User manual

AVE AF962 User manual

AVE

AVE AF962 User manual

AVE AF962 User manual

AVE

AVE AF962 User manual

AVE AF45362 User manual

AVE

AVE AF45362 User manual

AVE AF969R User manual

AVE

AVE AF969R User manual

AVE AF969F User manual

AVE

AVE AF969F User manual

AVE domina AF976R-DB User manual

AVE

AVE domina AF976R-DB User manual

AVE AF974R-DB User manual

AVE

AVE AF974R-DB User manual

AVE AF969R User manual

AVE

AVE AF969R User manual

AVE LUCE AMICA User manual

AVE

AVE LUCE AMICA User manual

AVE AF974R-DB User manual

AVE

AVE AF974R-DB User manual

AVE AF975R-DB User manual

AVE

AVE AF975R-DB User manual

AVE AF970R User manual

AVE

AVE AF970R User manual

AVE AF45 62 Series User manual

AVE

AVE AF45 62 Series User manual

Popular Security Sensor manuals by other brands

UTC Fire and Security Det-Tronics X2200 instructions

UTC Fire and Security

UTC Fire and Security Det-Tronics X2200 instructions

Texecom Capture P15-W manual

Texecom

Texecom Capture P15-W manual

Technimount System Safety Arm System 500 user guide

Technimount System

Technimount System Safety Arm System 500 user guide

industrie technik SEW-PT1000 instructions

industrie technik

industrie technik SEW-PT1000 instructions

DMP Electronics XT30INT installation guide

DMP Electronics

DMP Electronics XT30INT installation guide

Dräger X-plore 5500 Instructions for use

Dräger

Dräger X-plore 5500 Instructions for use

Busch-Jaeger WaveLINE 6721 Installation and operating instructions

Busch-Jaeger

Busch-Jaeger WaveLINE 6721 Installation and operating instructions

Medusa MS-350 manual

Medusa

Medusa MS-350 manual

GST DC-9103 manual

GST

GST DC-9103 manual

FRIEDLAND Spectra Plus L420N WHI instruction manual

FRIEDLAND

FRIEDLAND Spectra Plus L420N WHI instruction manual

Interlogix 6540 Installation sheet

Interlogix

Interlogix 6540 Installation sheet

Boltek LRX-1 Installation & operation guide

Boltek

Boltek LRX-1 Installation & operation guide

STEINEL PROFESSIONAL DALI-2 IS 3360 Information

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL DALI-2 IS 3360 Information

Veeder-Root FX Quick troubleshooting guide

Veeder-Root

Veeder-Root FX Quick troubleshooting guide

Osram HIGH BAY Fitting instructions

Osram

Osram HIGH BAY Fitting instructions

Niko 100-00700 instructions

Niko

Niko 100-00700 instructions

Fisher Darex 715004 Instructions for use

Fisher Darex

Fisher Darex 715004 Instructions for use

Hytronik HIR24 quick start guide

Hytronik

Hytronik HIR24 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.