FOR YOUR SAFETY
If you smell gas:
1. Shut off the gas to the appliance.
2. Extinguish any open flame.
3. If odour continues, immediately call your gas supplier.
Do not store or use gasoline or other flammable vapour
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Read the instructions thoroughly before installing or
servicing this equipment.
FOR OUTDOOR USE ONLY
PROPANE GAS
The ideal solution for extending the season of
outdoor entertaining
Creates a stylish and attractive ambience
Direct ignition
Stainless steel burner for extra long-term reliability
Complete with hose and POL regulator
Efficient and powerful 32 MJ/h output
Adjustable heat output
Operates for approximately 9 hours on a properly
filled 9Kg Propane cylinder
For outdoor use only
Gas certified to Australian standards
EDEN
Model No. GF1003BLK
FLORENCE
Model No. GF1002CH
MOUNTAIN ASH
GAS FIRE PIT

2
Installation, Operation and Maintenance Instructions
INSTALLATION
3. Proper clearance from combustible materials must
be maintained at all times. The minimum clearances
are as follows:
Minimum Clearance from Combustibles:
Side 500 mm Rear 500 mm
Ceiling 1000 mm
Combustible materials are considered to be wood,
compressed paper, plant fibres, plastic, plexiglas or
other materials capable of being ignited and burned.
Such materials shall be considered combustible even
though flame proofed, fire-retardant treated or plastered.
Additional clearance may be required for glass, painted
surfaces and other materials which may be damaged by
radiant or convection heat.
4. The appliance must be placed on a level and
adequate footing and be readily accessible.
5. The gas manifold supply pressure must be regulated
at 2.75 kPa utilising an AGA approved regulator
(supplied with heater).
6. The appliance must be inspected before each use,
and at least annually by a qualified service person.
a. The appliance area must be kept clear and free
of combustible materials, gasoline and other
flammable vapours and liquids.
b. Gas orifices and burner must be kept clear of
dirt and cobwebs. Flow of combustion and
ventilation air through the perforated portions
of the heater must not be obstructed. Cleaning
with a soft brush before use and at least every
six months is recommended.
c. All gas connections should be checked for
leaks utilising a soap solution. Never use a
flame for this purpose.
d. The flame pattern should be visually checked
whenever the appliance is operated. If flames
extend beyond surface of the guard the
appliance should be turned off and should not
be operated again until the unit is serviced and
or repaired.
e. Any cleaning agent used on the appliance
should be of a non-combustible and non-
corrosive nature.
Important Safety Rules
This appliance must only be used in a well
ventilated area.
1. This appliance shall not be installed or used
indoors, in buildings, garages or any other
enclosed area.
2. DO NOT place articles on or against this
appliance.
3. DO NOT use or store flammable materials near
this appliance.
4. Children and adults should be alerted to the
hazards of high surface temperatures, burns
and clothing ignition.
5. Children should be carefully supervised when
they are in the area of the appliance.
6. NEVER hang anything including clothes or
other flammable items on the appliance.
7. DO NOT operate this appliance unless it is
fully assembled with burner guard in place.
8. DO NOT SPRAY AEROSOLS IN THE
VICINITY OF THIS APPLIANCE WHILE IT IS
IN OPERATION.
9. Installation and repair should be done by a
qualified service person. The appliance must
be inspected before use and at least annually
by a qualified service person. It is imperative
that the control compartment, burners and
circulating air passages of the appliance be
kept clean.
Prior to assembling your appliance, the following must
be reviewed. Compliance with the following should result
in satisfactory heater operation. This instruction manual
should be retained for future reference. The installation
must conform with local codes or authority having
jurisdiction.
1. The appliance is intended for residential and non-
residential outdoor spaces. The installation must
conform with local codes and with the Australian
Standard AS/NZS 5601.
2. Adequate clearance around air openings into the
combustion chamber, clearances from combustible
materials, provisions for accessibility and for
combustion and ventilating air supply must be
maintained at all times when the appliance is
operating.

3
Installation, Operation and Maintenance Instructions 7. The hose must be protected from contact with
hot or sharp surfaces both during use and while
in storage. The hose assembly should be visually
inspected prior to each use of the heater. If
excessive abrasion or wear is evident, or the hose
is cut, it must be replaced prior to operating the
heater. The replacement hose assembly may be
obtained from the manufacturer.
8. DO NOT use any pressure regulator or hose
assembly other than those supplied with the
appliance. Replacement pressure regulator
and hose assembly must be those specified.
Replacement parts may be obtained from the
manufacturer or your local sales representative.
9. Installation and use of this appliance must conform
with local codes and AS/NZS 5601.
10. This appliance is designed to operate with a
standard 9Kg propane cylinder with Approved
Cylinder Connection.
11. The valve outlet must be maintained in good
condition. When the cylinder is not in use, be sure
to cover it with a dust cap. A leak test should be
performed with soapy water whenever connecting a
new cylinder. NEVER use a match to test for leaks.
12. The propane cylinder must be turned off whenever
the appliance is not in use. When the appliance
is to be stored indoors, the propane cylinder and
the heater must be disconnected and the cylinder
stored in accordance with the Standard for Storage
and Handling of Liquefied Gases.
IMPORTANT
Storage of an appliance indoors with the cylinder
attached is only permitted if the size of the cylinder
complies with AS/NZS 1596; otherwise cylinders
must be stored outdoors in a well ventilated area.
The guards are fitted to this appliance to reduce
the risk of fire or injury from burns and no part of it
should be removed.
This appliance must be protected from exposure to
rain. Use cover, not supplied.
This appliance must not be operated in the rain.
Any modification to the appliance not described in the
installation instructions may compromise the safety of
this appliance. Special concern is as follows:
(1) DO NOT bypass thermocouple;
(2) DO NOT operate the appliance without
the glass guard;
Clothing or other flammable materials should not be
hung from the heater, or placed on or near the heater.
The area above the burner may be extremely hot. Direct
contact with these metal surfaces should be avoided in
order to prevent burns or clothing ignition.
Screw the coupling nut of regulator into the cylinder valve
outlet.
POL CYLINDER CONNECTION DEVICE
Type of Gas Propane
Consumption 32 MJ/h
Operating Pressure 2.75 kPa
Injector Size 1.58 mm
Appliance specifications can be found on the data label.

LEAK CHECK
WARNING!
A leak test must be performed annually and each
time a cylinder is hooked up or if a part of the gas
system is replaced.
WARNING!
Never use an open flame to check for gas leaks.
Be certain no sparks or open flames are in the area
while you check for leaks. Sparks or open flames
will result in a fire or explosion, damage to property,
serious bodily injury, or death.
Leak Testing
This must be done before initial use, annually and
whenever any components are replaced or serviced.
Do not smoke while performing this test, and remove all
sources of ignition. Turn burner control to the off position.
Turn gas supply valve on.
Spray or brush a solution of liquid soap and water
onto all joints and connections of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose
joint or have the part replaced with one recommended by
our service agent and have the appliance inspected by a
certified gas installer.
If the leak cannot be stopped, immediately shut off gas
supply, disconnect it, and have the appliance inspected
by a certified gas installer or dealer. Do not use the fire pit
until the leak has been corrected.
4
Servicing Instructions
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is firmly secured.
WARNING!
For storage and cylinder exchange, disconnect
the cylinder only. Do not disconnect hose from the
appliance.

LEAK CHECK
STEP 1
Position the fire pit in the outdoor area you would like to use it. Ensure that this location is OUTDOORS, refer to page 7
for clearances.
Pour the glass pebbles into the burner area away from the square metal cover.
Position the pebbles evenly around the burner and level out and try to keep the pebbles lower around the square metal
cover.
OUTDOOR GAS FIRE PIT ASSEMBLY
5
KEEP CLEAR
IMPORTANT: Remove all transit and packaging material from all components before beginning assembly. Dispose of in
an environmentally friendly manner.
This manual suits for next models
1
Table of contents
Other Gasmate Outdoor Fireplace manuals
Popular Outdoor Fireplace manuals by other brands

The Fireplace
The Fireplace JETMASTER 700 D installation instructions

Superior
Superior VRE4543EN Installation and operation instructions

Napoleon
Napoleon PATIOFLAME GPFN Installation and operation instructions

Endless Summer
Endless Summer Dakota GAD19101ES owner's manual

Vermont Castings
Vermont Castings ODGSR36A Homeowner's installation and operating manual

FEUERHAND
FEUERHAND PYRON user manual