I. GENERAL
This luminaire has a beautiful outline, be compact, lightweight and
easy to use. It also has the features of soft light, safety and high
efficiency. It is main designed for indoor lighting application, and
should not be used in areas of limited ventilations, or in high ambient
temperature enclosures. It is suitable for mounting on a normally
flammable surface. Best results will be obtained if installed and
maintained according to the following recommendations. Please refer
section III for the application limitation details.
The Manufacturer has made every effort during the design and
construction stages to make its products completely free of risks
when correctly used. Note however that accident prevention and
safety regulations stipulate that the users of the product is obliged
to ensure that all persons involved in servicing, installing, handling,
using or selling the products are familiar with the information supplied
by the Manufacturer and fully aware of any precautions that must
be adopted. Depending on the circumstances, the instructions in
this document must be communicated, together with any other
information that may be necessary, to any Company or person
involved in the installation of GE lighting products.
II. UNPACKING
The luminaire has been properly packed to avoid damage during
transit. Inspect the luminaries to confirm there is no damage. Do not
install a damaged luminaire or damaged luminaire components.
The carton consists of:
• Fixture
• Leaflet
• Accessories
III. APPLICATION NOTICE
PLEASE APPLY THE PRODUCT ACCORDING TO FOLLOWING
STATEMENT
This is a fixed general-purpose luminaire mounted with fluorescent
lamp, which can be used for interior installation, or connect to
a series. Application can be in kitchen, shopping market & office
building.
IV. INSTALLATION
TOOLS/ACCESSRIES YOU WILL NEED
Screwdriver – (6~12mm): Used for drive the screw in for the mounting
Class II IP20 220-240V~ 50/60Hz
GE
Lighting Installation, Use and Maintenance Manual
T5 Fluorescent Fixture Series
These Instructions do not purport to cover all details or variations in
luminaire nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should fur-
ther information be desired or should particular problem arise which
are not covered sufficiently for the purchaser’s purpose, the matter
should be referred to General Electric Company.
READ THROUGHLY BEFORE INSTALLATION
Save these instructions for future use
CAUTION FOR ELECTRIC SHOCK/RISK OF BURN/PROPER
INSTALLATION
• Non-professionals are not allowed to operate. Shut off the
power before maintenance.
• Risk of burn, allow lamps/fixture to cool down before handling.
WARNING
• Ensure this manual is provided to the installers and users;
• Cut off the power before installation and maintenance;
• If series connection is applied, the luminaire quantities must be
not more than 10.
• This fixture is only used for indoor, under no circumstances be
used in high temperature and high humidity environment.
WARNING
Risk of Injury
• Luminaire may fall down if not installed properly, follow instal-
lation instructions
• Ware safety glasses and proper aid during installation and
maintenance
CAUTION
The luminaire can be installed at a fixed surface with two brackets.
(See Fig.1)
Step by Step:
1) Confirm the installation room, and refer to section VI the size of
luminaire.
2) Install the two brackets to fixed surface with screws of provided.
(Ensuring that the screws don’t touch any obstructions such as
cables, water pipes, etc.)
3) Fix the luminaire to the two brackets directly.
4) Adjust luminaire to desirable position.
5) Refer to section V for installation of lamp.
2. Series connection
Fixture can be connected by two ways, and the maximum
allowable connection quantity is 10 pieces. (See Fig.2)
In addition to above introduction, we are also providing multiple combinations to customer, including with/without diffuser, different lamp color
temperature, package and accessories. For detail information please contact GE’s sales team or distribution agency.
PRODUCT DIMENSIONS AND OUTLINES (mm)
VI. PRODUCT INFORMATION
PRODUCT BASIC INFO
V. MAINTENANCE / LAMP REPLACEMENT
FAILURE PARTS NEED TO BE REPLACED IF YOU INSPECT THE
LAMP EXTINCT, FLICKING OR CYCLING. ORDER THE REPLACEMENT
PART INDIVIDUALLY. CONTACT THE MANUFACTURES FOR THE
MAINTENANCE SERVICE.
LAMP REPLACEMENT
Light output is also dependent on burning time of lamp. In
applications where light levels are critical, it may be desirable to
replace lamps before the end of life. Lamp manufacturer can provide
life curve datasheet of light
output
1) Shut off power.
2) Carefully remove the diffuser if have.
3) Use one hand to push the both side of end cap and another hand
release the cover. (See Fig.3)
4) Turn 90°and remove the lamps to be replaced.
5) Re-install the luminaire in line with the requirements of qualified lamp.
6) Restore.
If lamp is handled, fingerprint, grease or oils should be removed from
lamp with isopropyl alcohol. This will remove material that will cause
whitish spotting, and premature lamp failure. Dry lamp carefully with
cotton or clean cloth.
GE T5 Starcoat ™ lamp is recommended
Notice: Luminaires suitable for direct mounting on normally
flammable surfaces.
Wiring Series
connection
Coupler Series
connection
(Fig.1)
(Fig.2)
• Please note the lamp type, wattage shall be same as the indi-
cation of the product label.
• Cut off the power before installation, and let lamp and fixture
cool down.
• The diffuser is frangible, cannot press hardly.
WARNING
(Fig.3)
Description Lamp & Power Rating
Voltage
Power
Current
Frequency PF Max Series
Current
Recommended
GE lamp
Size mm (LxWxH)
DMS 08 Series T5 LFL 1x8W 220-240V~ 0.075A 50/60Hz 0.95 0.85A F8T5 318x24.5x47
DMS 14 Series T5 LFL 1x14W 220-240V~ 0.13A 50/60Hz 0.95 1.4A F14W/T5/HE 579x24.5x47
DMS 21 Series T5 LFL 1x21W 220-240V~ 0.11A 50/60Hz 0.95 2A F21W/T5/HE 879x24.5x47
DMS 28 Series T5 LFL 1x28W 220-240V~ 0.14A 50/60Hz 0.95 1.5A F28W/T5/HE 1179x24.5x47
www.gelighting.com
and General Electric are both registered trademarks
of the General Electric Company
INSTALL LUMINAIRE
1. Install Luminaire
904822
GE Lighting Co., Ltd.
No. 88, Lane 1517, Hu Yi Gong Road,
Jiading District, Shanghai, 201802, P.R.C
+86-400-821-1186
www.gelighting.com

Other GE Lighting Light Fixture manuals

GE Lighting Evolve User manual

GE Lighting

GE Lighting Evolve User manual

GE Lighting Albeo ABR1 Series User manual

GE Lighting

GE Lighting Albeo ABR1 Series User manual

Popular Light Fixture manuals by other brands

Skystar SR-300 user manual

Skystar

Skystar SR-300 user manual

Martin MAC Viper Wash user guide

Martin

Martin MAC Viper Wash user guide

Ayra ERO 540 MKII user manual

Ayra

Ayra ERO 540 MKII user manual

Metalux RSRK installation instructions

Metalux

Metalux RSRK installation instructions

SEBSON SET 8 UNDER quick start guide

SEBSON

SEBSON SET 8 UNDER quick start guide

Spaulding Lighting FRESNO SQ. installation instructions

Spaulding Lighting

Spaulding Lighting FRESNO SQ. installation instructions

Philips Lytespan 8108 specification

Philips

Philips Lytespan 8108 specification

Renkforce 1493869 operating instructions

Renkforce

Renkforce 1493869 operating instructions

Lumiere Cambria 355 Specifications

Lumiere

Lumiere Cambria 355 Specifications

Ryobi ONE+ PCL662 Operator's manual

Ryobi

Ryobi ONE+ PCL662 Operator's manual

U-Line H-7272 manual

U-Line

U-Line H-7272 manual

SImx LHT1115 installation instructions

SImx

SImx LHT1115 installation instructions

Cooper Lighting HALO LV208 Specification sheet

Cooper Lighting

Cooper Lighting HALO LV208 Specification sheet

KERN Optics OZB-IF User instructions

KERN Optics

KERN Optics OZB-IF User instructions

e-conolight C-LITE C-AR-B-DD Series installation instructions

e-conolight

e-conolight C-LITE C-AR-B-DD Series installation instructions

Cooper Lighting FAIL-SAFE CFF Specifications

Cooper Lighting

Cooper Lighting FAIL-SAFE CFF Specifications

Toplicht DHR 180 Mounting instructions

Toplicht

Toplicht DHR 180 Mounting instructions

Nicols INDECURVE 5 user guide

Nicols

Nicols INDECURVE 5 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.