manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Cooktop
  8. •
  9. GE Monogram ZGU122NPSS Manual

GE Monogram ZGU122NPSS Manual

This manual suits for next models

1

Other GE Cooktop manuals

GE PP989 Original instructions

GE

GE PP989 Original instructions

GE JGP628BEKBB Manual

GE

GE JGP628BEKBB Manual

GE JP676J Installation instructions

GE

GE JP676J Installation instructions

GE Monogram ZEU304 User manual

GE

GE Monogram ZEU304 User manual

GE JGP337 Operating instructions

GE

GE JGP337 Operating instructions

GE Monogram ZHU30 User manual

GE

GE Monogram ZHU30 User manual

GE Profile PP945 User manual

GE

GE Profile PP945 User manual

GE Radiant JP5030DJBB User manual

GE

GE Radiant JP5030DJBB User manual

GE JGP328SEKSS - 30" B/I Gas CKTP Manual

GE

GE JGP328SEKSS - 30" B/I Gas CKTP Manual

GE Profile JP340 User manual

GE

GE Profile JP340 User manual

GE PROFILE JP969BH User manual

GE

GE PROFILE JP969BH User manual

GE PCP912 User manual

GE

GE PCP912 User manual

GE JCP910 User manual

GE

GE JCP910 User manual

GE Profile JP340 User manual

GE

GE Profile JP340 User manual

GE JGP328 User manual

GE

GE JGP328 User manual

GE JGP628 How to use

GE

GE JGP628 How to use

GE ZEU676YSB User manual

GE

GE ZEU676YSB User manual

GE Halogen/Radiant Cooktop User manual

GE

GE Halogen/Radiant Cooktop User manual

GE Profile PP942SMSS Manual

GE

GE Profile PP942SMSS Manual

GE Monogram ZX2L SS User manual

GE

GE Monogram ZX2L SS User manual

GE JP389 Training manual

GE

GE JP389 Training manual

GE Profile PGP990SENSS Original instructions

GE

GE Profile PGP990SENSS Original instructions

GE PCP912 User manual

GE

GE PCP912 User manual

GE PHP9030 User manual

GE

GE PHP9030 User manual

Popular Cooktop manuals by other brands

Bonnet OPTIMUM 700 Technical instructions

Bonnet

Bonnet OPTIMUM 700 Technical instructions

Jenn-Air JGCP430 installation instructions

Jenn-Air

Jenn-Air JGCP430 installation instructions

Frigidaire FES367FCC Wiring diagram

Frigidaire

Frigidaire FES367FCC Wiring diagram

Ztove EZ2 DUO instruction manual

Ztove

Ztove EZ2 DUO instruction manual

Kleenmaid cooking GCTK9011 Instructions for use and warranty details

Kleenmaid

Kleenmaid cooking GCTK9011 Instructions for use and warranty details

Jenn-Air JGC2536EB00 Use & care guide

Jenn-Air

Jenn-Air JGC2536EB00 Use & care guide

Waldorf RN8603E-B Technical data sheet

Waldorf

Waldorf RN8603E-B Technical data sheet

Whirlpool SMP658CNEIXL quick guide

Whirlpool

Whirlpool SMP658CNEIXL quick guide

Wolf CI243C/B Use and care guide

Wolf

Wolf CI243C/B Use and care guide

Fulgor Milano F5PGK305S1 installation instructions

Fulgor Milano

Fulgor Milano F5PGK305S1 installation instructions

Wells WV-2HFG owner's manual

Wells

Wells WV-2HFG owner's manual

IKEA Lagan HGA4K user manual

IKEA

IKEA Lagan HGA4K user manual

Samsung NA36N9755 installation manual

Samsung

Samsung NA36N9755 installation manual

Miele KM 404 operating instructions

Miele

Miele KM 404 operating instructions

Lacor 69562 Instructions for use and maintenance

Lacor

Lacor 69562 Instructions for use and maintenance

Keating Of Chicago MG-2 manual

Keating Of Chicago

Keating Of Chicago MG-2 manual

Jenn-Air CCE1400 Use and care guide

Jenn-Air

Jenn-Air CCE1400 Use and care guide

KitchenAid KGCP482KSS0 parts list

KitchenAid

KitchenAid KGCP482KSS0 parts list

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
170135
Specification Created 10/08
ZGU122NPSS - Natural Gas Built-in Dual-Burner Cooktop
ZGU122LPSS - LP Gas Built-in Dual-Burner Cooktop
Dimensions and Installation Information (in inches)
Outdoor Built-in Cooktop
These cooktops are designed to be installed into a
non-combustible enclousure.
• The cooktop drops into the opening and hangs
from the side flanges. It does not require support
from the bottom.
• The cutout must be completely covered with
non-combustible material such as stone, brick,
ceramic tile, concrete board, etc. The countertop
surface and edges must be flat and level.
• If the countertop has an overhang, it must be
notched or cut back flush with the front face of
the cabinet below. See notched detail below.
• Allow 12" minimum clearance on both sides
and the back of the grill to adjacent vertical
combustible construction.
• These gas cooktops cannot be used below any
type of overhead construction.
• These cooktops are designed for outdoor use only.
Do not locate the cooktop in a building, garage or
other enclosed or semi-enclosed area.
• Locate the backside of the cooktop away from
prevailing winds and avoid cooking in windy
conditions.
26-1/2"
13"
10-1/2" to
the Bottom
of the Side
Support Flange
12" Min. to
Combustibles
on All Sides
11"
7/8" Overlap
at the back
*25" Countertop Depth
28" to Front of Bullnose
26-1/2" to Front
of Control Panel
10-7/8"
24-1/2"
11-7/8"
Gas and Electrical Locations
Outdoor
Cooktop
ZGU122
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
170135
Specification Created 10/08
ZGU122NPSS - Natural Gas Built-in Dual-Burner Cooktop
ZGU122LPSS - LP Gas Built-in Dual-Burner Cooktop
Features and Benefits
• A pair of 15,000-BTU sealed side burners offers
additional space for preparing pasta or boiling water
• The burner grates are uniquely contoured on one
side to hold woks
• Stainless steel cooktop burner cover
• Electronic, 120-volt ignition system makes grill
activation as simple as pressing a knob control
• High-altitude conversion kit allows the grill to
maintain gas efficiency in mountaintop locations
WB28X10119
• Model ZGU122NPSS - Naural gas
• Model ZGU122LPSS - Liquid propane Monogram grills are factory-set for Natural or LP gas
operation. Be sure to order the correct model for the
installation situation.
Conversion kits (WB28X10116 - LP to Natural gas and
WB28X10117 - Natural gas to LP) are available if the
wrong fuel type is ordered.
High altitude kit (WB28X10119) is also available for
operation above 2,000 feet. Order WB28X10118
to change the connection from LP portable (20 lb.
tank) to whole house stationary tank or to change a
stationary tank to portable.
Conversion kits must be installed by a qualified
service technician at additional cost. Order these kits
from your Monogram supplier.