GE DDC4500TWH User manual

WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQLQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDOFRGHV
,QWKHDEVHQFHRIORFDOFRGHV
LQVWDOODWLRQPXVWFRPSO\ZLWK1DWLRQDO)XHO*DV&RGH$16,=1)3$RUWKH&DQDGLDQ1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGH
&6$%
California Safe Drinking Water and Toxic Enforcement Act
7KLVDFWUHTXLUHVWKHJRYHUQRURI&DOLIRUQLDWRSXEOLVKDOLVWRIVXEVWDQFHVNQRZQWRWKHVWDWHWRFDXVHFDQFHUELUWKGHIHFWV
RU RWKHU UHSURGXFWLYH KDUP DQG UHTXLUHV EXVLQHVVHV WR ZDUQ FXVWRPHUV RI SRWHQWLDO H[SRVXUH WR VXFK VXEVWDQFHV *DV
DSSOLDQFHVFDQFDXVHPLQRUH[SRVXUHWRIRXURIWKHVHVXEVWDQFHVQDPHO\EHQ]HQHFDUERQPRQR[LGHIRUPDOGHK\GHDQGVRRW
FDXVHGSULPDULO\E\WKHLQFRPSOHWHFRPEXVWLRQRIQDWXUDOJDVRU/3IXHOV3URSHUO\DGMXVWHGGU\HUVZLOOPLQLPL]HLQFRPSOHWH
FRPEXVWLRQ([SRVXUHWRWKHVHVXEVWDQFHVFDQEHPLQLPL]HGIXUWKHUE\SURSHUO\YHQWLQJWKHGU\HUWRWKHRXWGRRUV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VH
RQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWRWKHRXWGRRUV
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHG
LWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKHVHLQVWUXFWLRQVDQGORFDOFRGHV)OH[LEOHYHQWLQJPDWHULDOVDUH
NQRZQWRFROODSVHEHHDVLO\FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWRZDWHUDQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKHFXVWRPHU
IN THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or
Jas ¿tter
When using ball-type gas shut-off valves, they shall be
the T-handle type
A flexible gas connector, when used, most not exceed 3
feet
INSTALLATION
INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully
IMPORTANT-6DYHWKHVHLQVWUXFWLRQVIRUORFDOLQVSHFWRU·VXVH
IMPORTANT-2EVHUYHDOOJRYHUQLQJFRGHVDQGRUGLQDQFHV
Note to Installer -%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKHFXVWRPHU
Note to Customer -.HHSWKHVHLQVWUXFWLRQVZLWK\RXU2ZQHU·V0DQXDOIRUIXWXUH
UHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRUGLVFDUGHGUHPRYHWKHGU\HUGRRU
,QVSHFWWKHGU\HUH[KDXVWRXWOHWDQGVWUDLJKWHQWKHRXWOHWZDOOVLIWKH\DUHEHQW
6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDPDUHORFDWHGLQWKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH&ORVHVXSHUYLVLRQRIFKLOGUHQLV
QHFHVVDU\ZKHQWKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLVDERYH)IRUVDWLVIDFWRU\RSHUDWLRQ
RIWKHGU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRWFRYHUHGXQGHUWKH:DUUDQW\
234D1582P010 31-16677 03-12 GE
COMMERCIAL
STACKED
GAS DRYERS 10
Tools and Materials You
Will Need
6OLSMRLQWSOLHUVµSLSHZUHQFKDQG
µDGMXVWDEOHZUHQFKHV[
6FUHZGULYHUVVORWWHGRUSKLOOLSVKHDG
&KDLQV[
µ[µVWXGV
:DOOKRRNV
µGLDPHWHUULJLGPHWDOGXFWGXFW
FODPSVHOERZVDQGH[KDXVWKRRG
)OH[LEOHJDVFRQQHFWRU
3LSHFRPSRXQG
6RDSVROXWLRQIRUOHDNGHWHFWLRQ
%DVLFVDIHW\SURWHFWLRQVXFKDVVDIHW\
JRJJOHVJORYHVDQGDUPSURWHFWLRQDUH
UHFRPPHQGHG
-'RQRWVWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOHYDSRUV
DQGOLTXLGVLQWKHYLFLQLW\RIWKLVRUDQ\RWKHUDSSOLDQFH
-WHAT TO DO IF YOU SMELL GAS
'RQRWOLJKWDQ\DSSOLDQFH
'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQH
LQ\RXUEXLOGLQJ
&OHDUWKHURRPEXLOGLQJRUDUHDRIDOORFFXSDQWV
,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU·V
SKRQH)ROORZWKHJDVVXSSOLHU·VLQVWUXFWLRQV
,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKHILUH
GHSDUWPHQW
-,QVWDOODWLRQDQGVHUYLFHPXVWEHSHUIRUPHGE\DTXDOL¿HG
LQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU
WARNING )RU\RXUVDIHW\WKHLQIRUPDWLRQ
LQWKLVPDQXDOPXVWEHIROORZHGWRPLQLPL]HWKHULVN
RI¿UHRUH[SORVLRQRUWRSUHYHQWSURSHUW\GDPDJH
SHUVRQDOLQMXU\RUGHDWK
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE
7KH$16,=VWDQGDUGUHTXLUHVWKHIROORZLQJVDIHW\
FDXWLRQVEHSRVWHGDQGGLVSOD\HGLQDSURPLQHQW
ORFDWLRQ
D,QVWUXFWLRQVWREHIROORZHGLQWKHHYHQWWKHXVHUVPHOOV
JDV7KHLQIRUPDWLRQWREHSRVWHGVKDOOEHREWDLQHGE\
FRQVXOWLQJZLWKWKHORFDOJDVVXSSOLHU
E7KLVQRWH
Printed in Canada

7+('5<(50867127%(,167$//('256725(',1
$1$5($:+(5(,7:,//%((;326('72:$7(5$1'
25:($7+(53/($6(3529,'($'(48$7(63$&()25
23(5$7,1*$1'6(59,&,1*
'U\HUVLQVWDOOHGLQJDUDJHVLIDOORZHGE\ORFDOFRGHVPXVW
EHHOHYDWHGLQFKHVFPDERYHWKHÀRRU
STEP 1
$WWDFKWZRFKDLQVXVLQJ3KLOOLSVKHDGVFUHZVWRHDFKHQGRI
XSSHUXQLWFDELQHW
STEP 2
/RFDWHWZRZDOOVWXGVEHKLQGGHVLUHGRSHUDWLQJORFDWLRQRI
VWDFNHGXQLWV
127()RUZDOOVWXGVQRWDSSURSULDWHO\VSDFHGVHHVHFWLRQ
IRU$OWHUQDWH0HWKRGIRU,QVWDOODWLRQRI:DOO+RRNV
STEP 3
6FUHZWZRZDOOKRRNVLQWRWZRZDOOVWXGVVDPHKHLJKWDV
FKDLQFRQQHFWLRQVRQFDELQHWRIXSSHUXQLW%RWKFKDLQV
VKRXOGSXOOVWUDLJKWEDFNWRZDOOVWXGVRUDQJOHRXWZDUG
1(,7+(5FKDLQVKRXOGDQJOHLQZDUG
127(7KH¿QDOFRQVWUXFWLRQPXVWZLWKVWDQGDSXOORI
OEV
STEP 4
&RQQHFWERWKGU\HUVWRJDVVXSSO\
6HH*$6&211(&7,21,1)250$7,21RIWKLV
LQVWUXFWLRQ
STEP 5
&RQQHFWERWKGU\HUVWRSRZHUVXSSO\6HH(/(&75,&$/
&211(&7,21,1)250$7,21VHFWLRQRIWKLVLQVWUXFWLRQ
STEP 6
&RQQHFWERWKGU\HUVWRH[WHUQDOH[KDXVW6HH(;+$867
,1)250$7,21VHFWLRQRIWKLVLQVWUXFWLRQ
STEP 7
+RRNERWKFKDLQVIURPXSSHUXQLWWRDSSURSULDWHZDOOKRRNV
WDNLQJXSDQ\VODFN
STEP 8
$GMXVWDOOOHYHOOLQJOHJV'U\HUPXVWEHOHYHOOHGDQGUHVW
¿UPO\RQDOOOHYHOOLQJOHJV
Installation Instructions
WARNING Personal Injury Hazard
Because of its weight and size, more than one person
is reTuired to lift, tilt or move the washerdryerFailure
to do so may result in personal injury
CAUTION: FOR PERSONAL SAFETY, STACKED
UNITS MUST BE FASTENED SECURELY TO WALL
Preparing the Installation Site and Unpacking the Dryer
3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
&KHFNWREHVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV
8VLQJWKHIRXUVKLSSLQJFDUWRQFRUQHUSRVWVDVSDGGLQJWZRRQHDFKVLGHFDUHIXOO\OD\WKHGU\HURQLWVOHIWVLGHDQG
UHPRYHIRDPVKLSSLQJSDG
5HWXUQWKHGU\HUWRDQXSULJKWSRVLWLRQ
0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
STEP 1
STEP 2
STEP 3
STEP 8
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU&RQVLGHUDWLRQ
mustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRURSHUDWLRQDQGVHUYLFH

1PREPARING FOR INSTALLATION OF
NEW DRYER
TIP: Install your dryer before installing your washer
This will allow better access when installing dryer exhaust
DISCONNECTING GAS
WARNING - NEVER REUSE
OLD FLE;IBLE CONNECTORS
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOH
FRQQHFWRUVZKHQLQVWDOOLQJJDVDSSOLDQFHV
REMOVING LINT FROM WALL EXHAUST
OPENING
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
7,/77+('5<(56,'(:$<6$1'5(029(7+()2$0
6+,33,1*3$'6%<38//,1*$77+(6,'(6$1'
%5($.,1*7+(0$:$<)5207+('5<(5/(*6%(685(
725(029($//2)7+()2$03,(&(6$5281'7+(
/(*6
Installation Instructions
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD DUCTING MATERIAL.
REPLACE WITH NEW CSA(AGA)
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
2GAS REQUIREMENTS
WARNING
,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQG
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6
&2'($16,=
7KLVJDVGU\HULVHTXLSSHGZLWKD9DOYH%XUQHU
$VVHPEO\IRUXVHRQO\ZLWKQDWXUDOJDV8VLQJFRQYHUVLRQ
NLW:(;\RXUORFDOVHUYLFHRUJDQL]DWLRQFDQ
FRQYHUWWKLVGU\HUIRUXVHZLWKSURSDQH/3JDV$//
&219(56,2160867%(0$'(%<3523(5/<75$,1('
$1'48$/,),('3(56211(/$1',1$&&25'$1&(:,7+
/2&$/&2'(6$1'25',1$1&(5(48,5(0(176
7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJV\VWHPGXULQJDQ\SUHVVXUHWHVWLQJRIWKDWV\V
WHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȺYDOYHGXULQJ
DQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJRIWHVW
SUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
$LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ
DFFHVVLEOHIRUWHVWJDXJHFRQQHFWLRQPXVWEHLQVWDOOHG
LPPHGLDWHO\XSVWUHDPRIWKHJDVVXSSO\FRQQHFWLRQWR
WKHGU\HU&RQWDFW\RXUORFDOJDVXWLOLW\VKRXOG\RXKDYH
TXHVWLRQVRQWKHLQVWDOODWLRQRIWKHSOXJJHGWDSSLQJ
6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
URRPZLWKWKHGU\HU
8VHSLSHWKUHDGVHDOHUFRPSRXQGDSSURSULDWHIRU
QDWXUDORU/3JDVRUXVH7HÀRQWDSH
<RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU
OLVWHGFRQQHFWRU$16,=&6$7KHOHQJWKRI
WKHFRQQHFWVKDOOQRWH[FHHGIW
&RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
2SHQVKXWRȺYDOYH
2"
2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
Alternate Method for Installation of Wall Hooks
STEP 1
,IZDOOVWXGVDUHQRWFRUUHFWO\VSDFHGRUFHQWHUHGEHKLQGXSSHUXQLWLW
PD\EHQHFHVVDU\WRDWWDFKDKRUL]RQWDOµ[µERDUGWRWKHH[LVWLQJZDOO
STEP 2
$WWDFKZDOOKRRNVLQDSSUR[LPDWHSRVLWLRQRIWZRFKDLQVRIXSSHUXQLWVR
HDFKFKDLQSXOOVVWUDLJKWEDFNWRZDOO
127(,IZDOOLVFRQFUHWHRUEORFNGULOOKROHVDQGXVHDSSURSULDWHZDOO
DQFKRUV7KH¿QDOFRQVWUXFWLRQPXVWZLWKVWDQGDSXOORIOEV
INTERNAL DUCT
OPENING CHECK THAT EXHAUSE
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL

Installation Instructions
3RECONNECTING GAS
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTER
ELBOW
ITEMS NOT SUPPLIED
ADAPTER
SHUT-OFF
VALVE
PIPE SIZE
AT LEAST 1/2"
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
3/8" NPT
Listed connector ANSI Z21.24 / CSA 6.10
FLARE NPT
127(7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
RQO\RQWKHRULJLQDOLQVWDOODWLRQDQGDUHQRWWREHUHXVHG
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
HQGRIDGDSWRUIUHHRIJUHDVHRLODQGWKUHDGVHDODQW
CAUTION: 8VHDGDSWRUVDVVKRZQ&RQQHFWRU
QXWVPXVWQRWEHFRQQHFWHGGLUHFWO\WRSLSHWKUHDGV
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
Tighten the flexible
gas line using two
adjustable wrenches.
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
7LJKWHQDOOFRQQHFWLRQVXVLQJWZRDGMXVWDEOH
ZUHQFKHV Do not over torque gas connections!
&KHFNDOOFRQQHFWLRQVIRUOHDNVZLWKVRDS\VROXWLRQRU
HTXLYDOHQW$SSO\VRDSVROXWLRQLeak test solution must
not contain ammonia which could cause damage to the
brass ¿ttings,IOHDNVDUHIRXQGFORVHYDOYHUHWLJKWHQWKH
MRLQWDQGUHSHDWWKHVRDSWHVW
4LEAK TEST
WARNING - NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS
OPEN
GAS VALVE.

6EXHAUST CONNECTION
WARNING -
BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE TO
DISCONNECT THE DRYER FROM ITS ELECTRICAL
SUPPLYPROTECT YOUR HANDS AND ARMS
FROM SHARP EDGES WHEN WORKING INSIDE
THE CABINETBE SURE TO WEAR GLOVES
7KHGU\HUVFRPHVUHDG\IRUUHDUH[KDXVWLQJ8QLWVKDYH
VHSDUDWHH[KDXVWV
REAR EXHAUST LOCATION
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\RI
ELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRGZDOOFDS,IWZRWXUQVPXVWEHFORVHUWKDQ
IWGHGXFWIWIURPWKHPD[LPXPOHQJWKVVKRZQLQWKH
WDEOHIRUHDFKRFFXUUHQFH
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
SEALING OF JOINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
7KHGXFWVKDOOQRWEHDVVHPEOHGZLWKVFUHZVRURWKHU
IDVWHQLQJPHDQVWKDWH[WHQGLQWRWKHGXFWDQGFDWFKOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\
ZUDSSLQJWKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULV
QHDUDLUFRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFH
FRQGHQVDWLRQDQGOLQWEXLOGXS
NOTE:1HYHULQVWDOOVFUHHQLQVLGHH[KDXVWGXFW
5EXHAUST INFORMATION
EXHAUST LENGTH
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDS
DQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXPGXFWOHQJWK
IRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOHEHORZ
0RUHWKDQWZRWXUQVLVQRWUHFRPPHQGHG7KHWRWDO
OHQJWKRIÀH[LEOHPHWDOGXFWVKDOOQRWH[FHHGIWP,Q
&DQDGDDQGLQWKH8QLWHG6WDWHVWKHUHTXLUHGH[KDXVWGXFW
GLDPHWHULVµPP
WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUKRPHH[KDXVWGXFW
8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDOVHPL
ULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HUWRWKHKRPH
H[KDXVWGXFW,WPXVWEHLQVWDOOHGLQDFFRUGDQFHZLWK
WKHVHLQVWUXFWLRQVDQGORFDOFRGHV
'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOODFHLOLQJ
JDV YHQW FUDZO VSDFH DWWLF XQGHU DQ HQFORVHG ÀRRU
RU LQ DQ\ RWKHU FRQFHDOHG VSDFH RI D EXLOGLQJ 7KH
DFFXPXODWHGOLQWFRXOGFUHDWHDSRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFWZLWK
DNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRIJUHDVHDQG
OLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'R QRW XVH GXFW ORQJHU WKDQ VSHFL¿HG LQ WKH H[KDXVW
OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJ
DSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVH OLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG
'R QRW DVVHPEOH GXFWZRUN ZLWK DQ\ IDVWHQHUV WKDW
H[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQDFFXPXODWH
OLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
3URYLGH DQ DFFHVV IRU LQVSHFWLRQ DQG FOHDQLQJ RI WKH
H[KDXVW V\VWHP HVSHFLDOO\ DW WXUQV DQG MRLQWV ([KDXVW
V\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDWOHDVWRQFHD\HDU.
,QVSHFLDOLQVWDOODWLRQVLWPD\EHQHFHVVDU\WRFRQQHFW
WKHGU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLO
W\SH GXFW $ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW
PD\EHXVHG21/<LQLQVWDOODWLRQVZKHUHULJLGPHWDORU
ÀH[LEOHPHWDOVHPLULJLGGXFWLQJFDQQRWEHXVHG$1'
ZKHUH D µ GLDPHWHU FDQ EH PDLQWDLQHG WKURXJKRXW
WKHHQWLUHOHQJWKRIWKHWUDQVLWLRQGXFW,Q&DQDGDDQG
LQ WKH 8QLWHG 6WDWHV RQO\ WKH ÀH[LEOH PHWDO IRLOW\SH
GXFWVWKDWFRPSO\ ZLWK WKH´2XWOLQHIRU&ORWKHV 'U\HU
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
Installation Instructions
4" DIA.
4"
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90° Elbows Rigid Metal
45 ft.
35 ft.
25 ft.
30 ft.
20 ft.
10 ft.
0
1
2
Use only for short
run installations
Rigid Metal
3 1/2"
11 3/4"
Screw location
inside duct
NOTE: Add
to vertical
dimension
the distance
between
cabinet
bottom to
ÀRRUVXUIDFH

6EXHAUST CONNECTION CONT
THIS DRYER COMES READY FOR REAR
EXHAUSTINGIF SPACE IS LIMITED, USE
THESE INSTRUCTIONS TO EXHAUST
DIRECTLY FROM THE LEFT SIDE OR
BOTTOM OF THE CABINETNOTE: This
dryer cannot be exhausted to the right
side
Never use Àexible duct inside dryer
'HWDFK DQG UHPRYH WKH ERWWRP RU OHIW VLGH NQRFNRXW DV
GHVLUHG
5HPRYHWKH VFUHZLQVLGH WKHGU\HUH[KDXVWGXFWDQGVDYH
3XOOWKHGXFWRXWRIWKHGU\HU3URWHFWVKDUSHGJHVDURXQGWKH
NQRFNRXWDQGH[KDXVWRSHQLQJZLWKWKHWDSH
&XWWKHGXFWDVVKRZQ.HHSSRUWLRQ$
7KURXJKWKHUHDURSHQLQJORFDWHWKHWDELQWKHPLGGOHRI
WKHDSSOLDQFHEDVH/LIWWKHWDEWRDERXWXVLQJDÀDW
VFUHZGULYHU
5HFRQQHFWDQGVHFXUHWKHFXWSRUWLRQ$RIWKHGXFW
WRWKHEORZHUKRXVLQJ0DNHVXUHWKDWWKH¿[LQJKROHLV
DOLJQHGZLWKWKHWDELQWKHEDVH8VHWKHVFUHZRILWHP
WRVHFXUHWKHGXFWLQSODFHWKURXJKWKHWDERQWKH
DSSOLDQFHEDVH
8VHVWDQGDUGPHWDOHOERZVDQGGXFWWRFRPSOHWH
H[KDXVWV\VWHP,QVHUWVWDQGDUGHOERZDQGGXFWV
WKURXJKUHDUDQGVLGHRUERWWRPRSHQLQJV
&RYHUWKHRSHQLQJDWWKHEDFNZLWKWKHSODWH.LW
:(0DYDLODEOHIURP\RXU/RFDO6HUYLFH3URYLGHU
PARTS AVAILABLE FROM LOCAL SERVICE
ORGANIZATION
5LJLG0HWDO'XFW&RPSRQHQWV
:;;µ;·'XFW
:;;µ[·'XFW
:;;µ(OERZ
:;;$OXPLQXP+RRG
)OH[LEOH0HWDO'XFW&RPSRQHQWV
:;;µGLD)OH[LEOH0HWDO6HPL5LJLG
8//LVWHG7UDQVLWLRQ'XFWLQFOXGHVHOERZV
Installation Instructions
9
"
AB
FIXING HOLE
WARNING-NEVER LEAVE THE
BACK OPENING WITHOUT THE PLATE
7ALCOVE OR CLOSET INSTALLATION
,I \RXUGU\HULVDSSURYHG IRULQVWDOODWLRQLQDQDOFRYHRU
FORVHWLWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
7KH GU\HU MUST EH YHQWHG WR WKH RXWGRRUV 6HH WKH
EXHAUST INFORMATIONVHFWLRQ
0LQLPXPFOHDUDQFHIURPFRPEXVWLEOHVXUIDFHVDQGQRQ
FRPEXVWLEOHVXUIDFHVIRUDLULQWDNHSXUSRVHVLV
LQHLWKHUVLGH
LQIURQWDQGUHDU
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE
REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE
WALL IS 55 in
0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
&ORVHW GRRUV PXVW EH ORXYHUHG RU RWKHUZLVH YHQWLODWHG
DQGPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHU
DQGDGU\HUGRRUVPXVWFRQWDLQDPLQLPXPRIVTLQ
RIRSHQDUHDHTXDOO\GLVWULEXWHG
7KH FORVHW VKRXOG EH YHQWHG WR WKHRXWGRRUV WR SUHYHQW
JDVSRFNHWLQJLQFDVHRIDJDVOHDNLQWKHVXSSO\OLQH
1RRWKHUIXHOEXUQLQJDSSOLDQFHVKDOOEHLQVWDOOHGLQWKH
VDPHFORVHWZLWKWKHGU\HU

Installation Instructions
CARE AND CLEANING
USER MAINTENANCE INSTRUCTIONS
The Drum7KHGUXPLVUXVWUHVLVWDQWDQGUHTXLUHV
QRVSHFLDOFDUH
The Exterior:LSH RȺ DQ\ VSLOOVRUZDVKLQJFRPSRXQGV
:LSHRUGXVWZLWKGDPSFORWK7U\QRWWRVWULNHWKHVXUIDFH
ZLWKVKDUSREMHFWV
The Lint Filter:LSHOLQW¿OWHUEHIRUHHYHU\XVH3HULRGLFDOO\
OLQW¿OWHUVKRXOGEHUHPRYHGDQGVXFWLRQKRVHIURPYDFXXP
FOHDQHUVKRXOGEHLQVHUWHGLQWRWKHRSHQLQJ
Dryer Exhaust ,QVSHFW DQG FOHDQ WKH GU\HU H[KDXVW
GXFWLQJDWOHDVWRQFHD\HDU
'RQRWREVWUXFWWKHÀRZRIFRPEXVWLRQDQGYHQWLODWLQJDLU
7KHDLULQWDNHLVORFDWHGRQUHDURIGU\HU
.HHSGU\HUDUHDFOHDUDQGIUHHIURPFRPEXVWLEOHPDWHULDOV
JDVROLQHDQGRWKHUÀDPPDEOHYDSRUVDQGOLTXLGV
To store dryer)RUVKRUWSHULRGRIWLPHGLVFRQQHFWSRZHU
VXSSO\DQGFOHDQOLQW¿OWHU
'RQRWLQVWDOORUVWRUHGU\HUZKHUHLWZLOOEHH[SRVHGWRWKH
ZHDWKHU
CAUTION:
'U\HUFRQWUROSDQHODQG¿QLVKHVPD\EHGDPDJHGE\
VRPHODXQGU\SUHWUHDWPHQWVRLODQGVWDLQUHPRYHU
SURGXFWVLIVXFKSURGXFWVDUHVSUD\HGRQRUKDYHGLUHFW
FRQWDFWZLWKWKHGU\HU
$SSO\WKHVHSUHWUHDWPHQWSURGXFWVDZD\IURPWKH
GU\HU7KHIDEULFPD\WKHQEHZDVKHGDQGGULHG
QRUPDOO\'DPDJHWR\RXUGU\HUFDXVHGE\SUHWUHDWPHQW
SURGXFWVLVQRWFRYHUHGE\\RXU:DUUDQW\
8ELECTRICAL CONNECTION INFORMATION
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK, AND
PERSONAL INJURY:
DO NOT USE AN EXTENSION CORD
OR AN ADAPTER PLUG WITH THIS
APPLIANCE
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFH
ZLWKORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFH
RIORFDOFRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/
(/(&75,&$/&2'($16,1)3$12
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, protected by a 15- or 20-amp circuit breaker or
time delay fuseIf electrical supply provided does not
meet the above speci¿cations, it is recommended that
a licensed electrician install an approved outlet
WARNING - THIS DRYER IS
EQUIPPED WITH A THREE-PRONG
(GROUNDING) PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD
AND SHOULD BE PLUGGED DIRECTLY
INTO AN INDIVIDUAL, PROPERLY
GROUNDED THREE-PRONG RECEPTACLE
DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THIS PLUG
ATTACH GROUND WIRE (OBTAIN
LOCALLY) TO EACH DRYER
ENSURE PROPER GROUND EXISTS BEFORE USE
$QH[WHUQDOJURXQGZLUHQRWSURYLGHGZKLFKPHHWVORFDO
FRGHVPD\EHDGGHGE\DWWDFKLQJWRWKHJUHHQJURXQG
VFUHZRQWKHUHDURIWKHGU\HUDQGWRDJURXQGHGPHWDO
FROGZDWHUSLSHRURWKHUHVWDEOLVKHGJURXQG
EXTERNAL GROUND (IF REQUIRED)
NOTE TO INSTALLER
AFTER INSTALLATION CHECK THE FOLLOWING:
(;+$867'8&70XVWPHHWVSHFVLQWKH(;+$867
,1)250$7,21VHFWLRQ
*5281',1*'U\HUPXVWEHSURSHUO\JURXQGHGWRFRQIRUPWR
ORFDOFRGHVDQGRUGLQDQFHUHTXLUHPHQWV
23(5$7,217XUQGU\HURQDQGFKHFNIRUKHDW
+DQGFXVWRPHUWKH2ZQHU·V0DQXDO*LYHLQVWUXFWLRQVRQ
RSHUDWLQJWKHGU\HU$QVZHUDQ\TXHVWLRQV
*LYHWKHVH,QVWDOODWLRQ,QVWUXFWLRQVWRWKHFXVWRPHU
REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY
IMPORTANT PRODUCT NOTIFICATIONS
3OHDVHJRWRZZZ*($SSOLDQFHVFRPRUPDLOLQWKH
3URGXFW5HJLVWUDWLRQ&DUG
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU
&DQDGD
*DVFORWKHVGU\HUVLQSXWUDWLQJVDUHEDVHGRQVHDOHYHO
RSHUDWLRQDQGQHHGQRWEHDGMXVWHGIRURSHUDWLRQDWRU
EHORZIWHOHYDWLRQ
)RURSHUDWLRQDWHOHYDWLRQVDERYHIWLQSXWUDWLQJV
VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFKIW
DERYHVHDOHYHO
,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQGRUGLQDQFHVRU
LQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6&2'($16,=
ADJUSTING FOR ELEVATION

Installation Instructions
Table of contents
Other GE Dryer manuals
Popular Dryer manuals by other brands

Intelligent
Intelligent G-Force Junior user manual

Alliance Laundry Systems
Alliance Laundry Systems 510977R9 Installation & operation

Hotpoint
Hotpoint DLB2880D Use and care

Electrolux
Electrolux IQ-Touch EIMGD60LT installation guide

Whirlpool
Whirlpool W10184516A installation instructions

Samsung
Samsung DV431AEP user manual

Midea
Midea MLE52N4AWW User's manual & installation instructions

Hoover
Hoover DYC 88132BX Instruction book

Frigidaire
Frigidaire FDE7970E operating instructions

Maytag
Maytag MDG78PNAWS installation manual

Simpson
Simpson SDV457HQWA user manual

Whirlpool
Whirlpool AWZ8CDS/PRO Health & safety, use & care and installation guide