GE GTDN500EMWS User manual

WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQ
LQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQ
DFFRUGDQFHZLWKORFDOFRGHV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWR
WKHRXWGRRUV
DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV
,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH
8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQG
LQConnecting The Dryer To House Vent RQSDJHRIWKLVPDQXDO
)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHG
DQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQG
LQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOG
EHH[SRVHGWRZDWHUDQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQVInstallers:%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHPDQXIDFWXUHU·V
LQVWUXFWLRQVDQGORFDOFRGHV
NOTE: Installation and service of this dryer
requires basic mechanical and electrical
skills. It is your responsibility to contact
a quali¿ed installer to make the electrical
connections.
Installation
Instructions
Electric Dryer
04
Questions on Installation? Call: 800.GE.CARES (US)
RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT-6DYHWKHVHLQVWUXFWLRQV
IRUORFDOLQVSHFWRU·VXVH
IMPORTANT-2EVHUYHDOOJRYHUQLQJ
FRGHVDQGRUGLQDQFHV
Note to Installer -%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
Note to Customer -.HHSWKHVHLQVWUXFWLRQV
ZLWK\RXU2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
GLVFDUGHGUHPRYHWKHGU\HUGRRU
,QVSHFWWKHGU\HUH[KDXVWRXWOHWDQGVWUDLJKWHQ
WKHRXWOHWZDOOVLIWKH\DUHEHQW
6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDP
DUHORFDWHGLQWKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH
&ORVHVXSHUYLVLRQRIFKLOGUHQLVQHFHVVDU\ZKHQ
WKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLV
DERYH)IRUVDWLVIDFWRU\RSHUDWLRQRIWKH
GU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQ
LVQRWFRYHUHGXQGHUWKHZDUUDQW\
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
TOOLS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT (IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
4” COVER PLATE (IF NEEDED
(KIT WE1M454)
234D1582P004 31-16224-2 03-12 GE
6WHS3UHSDUHWKH$UHDDQG([KDXVWIRU,QVWDOODWLRQRI
1HZ'U\HUVHHVHFWLRQ
6WHS&KHFNDQG(QVXUHWKH([LVWLQJ([WHUQDO([KDXVWLV
&OHDQVHHVHFWLRQDQG0HHWV$WWDFKHG,QVWDOODWLRQ
6SHFL¿FDWLRQVVHHVHFWLRQ
6WHS5HPRYHWKH)RDP6KLSSLQJ3DGVVHHVHFWLRQ
6WHS0RYHWKH'U\HUWRWKH'HVLUHG/RFDWLRQ
6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ
6WHS&RQQHFWWKH([WHUQDO([KDXVWVHHVHFWLRQ
6WHS/HYHO<RXU'U\HUVHHVHFWLRQ
6WHS&KHFNWKH2SHUDWLRQRIWKH3RZHU6XSSO\9HQWLQJ
6WHS3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ
,QVWUXFWLRQVLQDORFDWLRQZKHUHWKH\ZLOOEHQRWLFHGE\WKH
RZQHU
)RU$OFRYHRU&ORVHW,QVWDOODWLRQVHHVHFWLRQ
)RU%DWKURRPRU%HGURRP,QVWDOODWLRQVHHVHFWLRQ
)RU0RELOHRU0DQXIDFWXUHG+RPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ
)RUVLGHRUERWWRPH[KDXVWVHHVHFWLRQ

Installation Instructions
2
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU
&RQVLGHUDWLRQmustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
1PREPARING FOR INSTALLATION
OF NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
2ELECTRICAL CONNECTION
INFORMATION
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK AND PERSONAL
INJURY:
DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFHZLWK
ORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFHRIORFDO
FRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/(/(&75,&$/
&2'($16,1)3$12
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: SInce January 1,1996, the National Electric code
requires that the new constructions utilize a 4-wire
connection to an electric dryer.
WARNING:Only a 4-conductor cord shall be
used when the appliance is installed in a location where
grounding through the neutral conductor is prohibited.
Grounding through the neutral is prohibited for the new
branch-circuit installations, mobile homes, recreational
vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
UHFHSWDFOH
5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHU
EDFN
5HPRYHDQGGLVFDUGJURXQGVWUDS.HHSWKHJUHHQ
JURXQGVFUHZIRUVWHS
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHURI
WKHWHUPLQDOEORFNPDUNHG1
$WWDFKJURXQGZLUHRISRZHUFRUGZLWKWKHJUHHQ
JURXQGVFUHZKROHDERYHVWUDLQUHOLHIEUDFNHW7LJKWHQ
DOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
N
L2
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
ELECTRICAL REQUIREMENTS
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDO
EUDQFKFLUFXLWSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\
IXVHVRUFLUFXLWEUHDNHUV$IRXURUWKUHHZLUHVLQJOH
SKDVH9RU9+]DPSFLUFXLW
LVUHTXLUHG,IWKHHOHFWULFVXSSO\GRHVQRWPHHWWKH
DERYHVSHFL¿FDWLRQVWKHQFDOODOLFHQVHGHOHFWULFLDQ
GROUNDING INSTRUCTIONS
7KLVGU\HUPXVWEHFRQQHFWHGWRDJURXQGHGPHWDO
SHUPDQHQWZLULQJV\VWHPRUDQHTXLSPHQWJURXQGLQJ
FRQGXFWRUPXVWEHUXQZLWKWKHFLUFXLWFRQGXFWRUVDQG
FRQQHFWHGWRWKHHTXLSPHQWJURXQGLQJWHUPLQDORQWKH
DSSOLDQFH
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.

Installation Instructions
3
CONNECTING DRYER USING 3-WIRE
CONNECTION
3-wire Connection
1RWIRUXVHLQ&DQDGD
'2127XVHIRU0RELOH+RPH,QVWDOODWLRQV
127IRUXVHRQQHZFRQVWUXFWLRQ
127IRUXVHRQUHFUHDWLRQDOYHKLFOHV
127IRUXVHLQDUHDVZKHUHORFDOFRGHVSURKLELW
JURXQGLQJWKURXJKWKHQHXWUDOFRQGXFWLRQ
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHU
EDFN
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHU
RIWKHWHUPLQDOEORFNPDUNHG1
%HVXUHJURXQGVWUDSLVFRQQHFWHGWRQHXWUDOFHQWHU
WHUPLQDORIEORFNDQGWRJUHHQJURXQGVFUHZRQFDEL
QHWUHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
COVER
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
3EXHAUST INFORMATION
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\
RIELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
NeverLQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHG
GRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRG
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
WARNING - IN CANADA AND IN
THE UNITED STATES, THE REQUIRED EX-
HAUST DUCT DIAMETER IS 4 IN (102mm). DO
NOT USE DUCT LONGER THAN SPECIFIED IN
THE EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect
installation are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQ
GXFW
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOO
FDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXP
GXFWOHQJWKIRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOH
EHORZ
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elb ows Rigid
Metal Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
0
1
2
3
4
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
Use only for sho rt
run installations
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.

Installation Instructions
4
5
LEVELING AND STABILIZING YOUR DRYER
LEVEL
SIDE-TO-SIDE.
4 LEVELING LEGS
LEVEL
FRONT-TO-BACK.
EXHAUST INFORMATION (cont)
SEALING OF JOINTS
$OOMRLQWVVKRXOGEHWLJKWWRDYRLGOHDNV7KHPDOHHQGRI
HDFKVHFWLRQRIGXFWPXVWSRLQWDZD\IURPWKHGU\HU
'RQRWDVVHPEOHWKHGXFWZRUNZLWKIDVWHQHUVWKDW
H[WHQGLQWRWKHGXFW7KH\ZLOOVHUYHDVDFROOHFWLRQ
SRLQWIRUOLQW
'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\
ZUDSSLQJWKHRYHUODSSHGMRLQWVZLWKGXFWWDSH
+RUL]RQWDOUXQVVKRXOGVORSHGRZQWRZDUGWKHRXWGRRUV
LQFKSHUIRRW
INSULATION
'XFWZRUNWKDWUXQVWKURXJKDQXQKHDWHGDUHDRULV
QHDUDLUFRQGLWLRQLQJVKRXOGEHLQVXODWHGWRUHGXFH
FRQGHQVDWLRQDQGOLQWEXLOGXS
NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL
NOT PLASTIC.
DUCT TAPE OR
DUCT CLAMP
4” METAL DUCT
(CUT TO PROPER
LENGTH)
DUCT TAPE OR
DUCT CLAMP
EXTERNAL
DUCT
OPENING
FOR STRAIGHT LINE INSTALLATION,
CONNECT THE DRYER EXHAUST TO
THE EXTERNAL EXHAUST HOOD
USING DUCT TAPE OR CLAMP.
STANDARD REAR EXHAUST
(Vented at floor level)
4EXHAUST CONNECTION
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 10 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.
WARNING - TO REDUCE THE
RISK OF FIRE OR PERSONAL INJURY:
7KLVFORWKHVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUWKHKRPHH[KDXVW
GXFW
8VHRQO\µULJLGPHWDORU8/OLVWHGÀH[LEOHPHWDO
VHPLULJLGRUIRLOW\SHGXFWWRFRQQHFWWKHGU\HU
WRWKHKRPHH[KDXVWGXFW,WPXVWEHLQVWDOOHG
LQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQGLQ
´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRI
WKLVPDQXDO
'RQRWWHUPLQDWHH[KDXVWLQDFKLPQH\DZDOO
DFHLOLQJJDVYHQWFUDZOVSDFHDWWLFXQGHUDQ
HQFORVHGÀRRURULQDQ\RWKHUFRQFHDOHGVSDFH
RIDEXLOGLQJ7KHDFFXPXODWHGOLQWFRXOGFUHDWHD
SRWHQWLDO¿UHKD]DUG
1HYHUWHUPLQDWHWKHH[KDXVWLQWRDFRPPRQGXFW
ZLWKDNLWFKHQH[KDXVWV\VWHP$FRPELQDWLRQRI
JUHDVHDQGOLQWFUHDWHVDSRWHQWLDO¿UHKD]DUG
'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVW
OHQJWKWDEOH/RQJHUGXFWVFDQDFFXPXODWHOLQW
FUHDWLQJDSRWHQWLDO¿UHKD]DUG
1HYHULQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
ZLOOFDXVHOLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UH
KD]DUG
'RQRWDVVHPEOHGXFWZRUNZLWKDQ\IDVWHQHUV
WKDWH[WHQGLQWRWKHGXFW7KHVHIDVWHQHUVFDQ
DFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
'RQRWREVWUXFWLQFRPLQJRUH[KDXVWHGDLU
3URYLGHDQDFFHVVIRULQVSHFWLRQDQGFOHDQLQJRI
WKHH[KDXVWV\VWHPHVSHFLDOO\DWWXUQVDQGMRLQWV
([KDXVWV\VWHPVKDOOEHLQVSHFWHGDQGFOHDQHGDW
OHDVWRQFHD\HDU
RECOMMENDED
CONFIGURATION
TO MINIMIZE
EXHAUST
BLOCKAGE.
ELBOW HIGHLY
RECOMMENDED
ELBOW HIGHLY
RECOMMENDED
NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.
STANDARD REAR EXHAUST
(Vented above floor level)

Installation Instructions
5
CONNECTING THE DRYER TO HOUSE VENT
RIGID METAL TRANSITION DUCT
)RUEHVWGU\LQJSHUIRUPDQFHDULJLGPHWDOWUDQVLWLRQGXFWLV
UHFRPPHQGHG
5LJLGPHWDOWUDQVLWLRQVGXFWVUHGXFHWKHULVNRIFUXVKLQJDQG
NLQNLQJ
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT
,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHWDO
VHPLULJLGGXFWLQJFDQEHXVHG.LW:;;
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
)RUPDQ\DSSOLFDWLRQVLQVWDOOLQJHOERZVDWERWKWKHGU\HU
DQGWKHZDOOLVKLJKO\UHFRPPHQGHGVHHLOOXVWUDWLRQVEHORZ
(OERZVDOORZWKHGU\HUWRVLWFORVHWRWKHZDOOZLWKRXWNLQNLQJ
DQGRUFUXVKLQJWKHWUDQVLWLRQGXFWPD[LPL]LQJGU\LQJ
SHUIRUPDQFH
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT
,QVSHFLDOLQVWDOODWLRQVLWPD\EHQHFHVVDU\WRFRQQHFWWKH
GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$8/OLVWHGÀH[LEOHPHWDOIRLOW\SHGXFWPD\EHXVHG21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG
GXFWLQJFDQQRWEHXVHG$1'ZKHUHDµGLDPHWHUFDQEH
PDLQWDLQHGWKURXJKRXWWKHHQWLUHOHQJWKRIWKHWUDQVLWLRQ
GXFW
,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO
W\SHGXFWVWKDWFRPSO\ZLWKWKH´2XWOLQHIRU&ORWKHV'U\HU
7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG
1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRU
RWKHUHQFORVHGVSDFHV
7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW
P
$YRLGUHVWLQJWKHGXFWRQVKDUSREMHFWV
)RUEHVWGU\LQJSHUIRUPDQFH
6OLGHRQHHQGRIWKHGXFWRYHUWKHFORWKHVGU\HURXWOHWSLSH
6HFXUHWKHGXFWZLWKDFODPS
:LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFWWR
LWVIXOOOHQJWK$OORZµRIGXFWWRRYHUODSWKHH[KDXVWSLSH
&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKW
DVSRVVLEOHIRUPD[LPXPDLUÀRZ
6HFXUHWKHGXFWWRWKHH[KDXVWSLSHZLWKWKHRWKHUFODPS
DO
ELBOW HIGHLY
RECOMMENDED
ELBOWS HIGHLY
RECOMMENDED
DON’T
DO NOT USE
EXCESSIVE
EXHAUST
LENGTH
DO NOT
CRUSH
FLEXIBLE
EXHAUST
AGAINST
WALL
DO NOT
SIT DRYER
ON FLEXIBLE
EXHAUST
7
BATHROOM OR BEDROOM INSTALLATION
7KHGU\HUMUSTEHYHQWHGWRWKHRXWGRRUV6HH
EXHAUST INFORMATIONVHFWLRQ
7KHLQVWDOODWLRQPXVWFRQIRUPZLWKORFDOFRGHVRULQWKH
DEVHQFHRIORFDOFRGHVZLWKWKHNATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70.
8
MOBILE OR MANUFACTURED HOME
INSTALLATION
,QVWDOODWLRQMUSTFRQIRUPWRWKHMANUFACTURED HOME
CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-80
RUZKHQVXFKVWDQGDUGLVQRWDSSOLFDEOHZLWKAMERICAN
NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO.
501B.
7KHGU\HUMUSTEHYHQWHGWRWKHRXWGRRUVZLWKWKH
WHUPLQDWLRQVHFXUHO\IDVWHQHGWRWKHPRELOHKRPHVWUXFWXUH
6HHEXHAUST INFORMATIONVHFWLRQ
7KHYHQWMUST NOTEHWHUPLQDWHGEHQHDWKDPRELOHRU
PDQXIDFWXUHGKRPH
7KHYHQWGXFWPDWHULDOMUST BE METAL
'RQRWXVHVKHHWPHWDOVFUHZVRURWKHUIDVWHQLQJGHYLFHV
ZKLFKH[WHQGLQWRWKHLQWHULRURIWKHH[KDXVWYHQW
6HHVHFWLRQIRUHOHFWULFDOFRQQHFWLRQLQIRUPDWLRQ
6ALCOVE OR CLOSET INSTALLATION
,I\RXUGU\HULVDSSURYHGIRULQVWDOODWLRQLQDQDOFRYHRUFORVHW
LWZLOOEHVWDWHGRQDODEHORQWKHGU\HUEDFN
7KHGU\HUMUSTEHYHQWHGWRWKHRXWGRRUV6HHWKHEXHAUST
INFORMATIONVHFWLRQV
0LQLPXPFOHDUDQFHEHWZHHQGU\HUFDELQHWDQGDGMDFHQWZDOOV
RURWKHUVXUIDFHVLV
LQHLWKHUVLGH
LQIURQWDQGUHDU
0LQLPXPYHUWLFDOVSDFHIURPÀRRUWRRYHUKHDGFDELQHWV
FHLOLQJHWFLVLQ
&ORVHWGRRUVPXVWEHORXYHUHGRURWKHUZLVHYHQWLODWHGDQG
PXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHDHTXDOO\
GLVWULEXWHG,IWKHFORVHWFRQWDLQVERWKDZDVKHUDQGDGU\HU
GRRUVPXVWFRQWDLQDPLQLPXPRIVTLQRIRSHQDUHD
HTXDOO\GLVWULEXWHG

Installation Instructions
6
10 DRYER EXHAUST TO RIGHT, LEFT
OR BOTTOM CABINET
WARNING - BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE
TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR HANDS
AND ARMS FROM SHARP EDGES WHEN
WORKING INSIDE THE CABINET. BE SURE TO
WEAR GLOVES
Note: Only 4” round rigid metal ducting allowed inside
dryer.
TAB LOCATION
Detach and remove the bottom, right or left side knockout
as desired. Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dryer.
REMOVE
SCREW
AND SAVE.
REMOVE
DESIRED
KNOCKOUT
(ONE ONLY).
ADDING NEW DUCT
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET
3UHDVVHPEOHµHOERZZLWKµGXFW:UDSGXFWWDSH
DURXQGMRLQW
,QVHUWGXFWDVVHPEO\HOERZ¿UVWWKURXJKWKHVLGH
RSHQLQJDQGFRQQHFWWKHHOERZWRWKHGU\HULQWHUQDO
GXFW
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer when inserting the
duct.
Cut the duct as shown and keep portion A.
9"
AB
FIXING HOLE
Through the rear opening, locate the tab in the middle of
the appliance base. Lift the tab to about 45º using a flat
blade screwdriver.
BEND TAB
UP 45 o
Reconnect the cut portion (A) of the duct to the blower
housing. Make sure that the shortened duct is aligned with
the tab in the base. Use the screw saved previously to secure
the duct in place through the tab on the appliance base.
RIGHT OR
LEFT SIDE
EXHAUST
PORTION "A"
FIXING
HOLE
EXHAUST CAN
BE ADDED TO
LEFT OR RIGHT SIDE
DUCT
TAPE
GARAGE INSTALLATION (IF ALLOWED
BY LOCAL CODES)
'U\HUVLQVWDOOHGLQJDUDJHVPXVWEHHOHYDWHGLQFKHV
FPDERYHWKHÀRRU
9

Installation Instructions
7
$SSO\GXFWWDSHDVVKRZQRQWKHMRLQWEHWZHHQWKH
GU\HULQWHUQDOGXFWDQGWKHHOERZ
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
,QVHUWWKHHOERZWKURXJKWKHUHDURSHQLQJDQGFRQQHFW
LWWRWKHGU\HULQWHUQDOGXFW
$SSO\GXFWWDSHRQWKHMRLQWEHWZHHQWKHGU\HULQWHUQDO
GXFWDQGHOERZDVVKRZQRQSDJH
ADDING COVER PLATE TO REAR
OF CABINET (SIDES AND BOTTOM
EXHAUST)
&RQQHFWVWDQGDUGPHWDOHOERZVDQGGXFWVWRFRPSOHWH
WKHH[KDXVWV\VWHP&RYHUEDFNRSHQLQJZLWKDSODWH.LW
:(0DYDLODEOHIURP\RXUORFDOVHUYLFHSURYLGHU
3ODFHGU\HULQ¿QDOORFDWLRQ
WARNING-NEVER LEAVE THE BACK
OPENING WITHOUT THE PLATE. (Kit
WE1M454)
PL ATE
(KIT WE1M454)
CHANGING DIRECTION OF
DOOR OPENING
2SHQWKHGRRUDQGUHPRYHWKH¿OOHUSOXJVRSSRVLWHWKH
KLQJHV:LWKWKHGRRUFRPSOHWHO\RSHQUHPRYHWKH
ERWWRPVFUHZVIURPHDFKKLQJHRQWKHGU\HUIDFH,Q
VHUWWKHVHVFUHZVDERXWKDOIZD\LQWRWKHTOPKROHVIRU
HDFKKLQJHRQWKHRSSRVLWHVLGHZKHUH\RXUHPRYHG
WKH¿OOHUSOXJV$SSO\¿UPSUHVVXUHWRJHWWKHVFUHZ
VWDUWHG
/RRVHQWKHWRSVFUHZVIURPHDFKKLQJHRQWKHGU\HU
IDFHKDOIZD\:LWKRQHKDQGKROGLQJWKHWRSRIWKH
GRRUDQGWKHRWKHUKDQGKROGLQJWKHERWWRPUHPRYH
WKHGRRUIURPWKHGU\HUE\OLIWLQJLWUPDQGOUT
5RWDWHWKHGRRU,QVHUWWKHGRRURQWKHRSSRVLWH
VLGHRIWKHRSHQLQJE\PRYLQJWKHGRRUINDQGDOWN
XQWLOWKHWRSKLQJHDQGWKHERWWRPKLQJHDUHUHVWLQJRQ
WKHWRSVFUHZVLQVHUWHGLQVWHS
5HPRYHWKHUHPDLQLQJVFUHZVIURPWKHVLGHRIWKH
RSHQLQJIURPZKLFKWKHGRRUZDVUHPRYHG:LWKWKHVH
VFUHZVVHFXUHHDFKKLQJHDWWKHERWWRP7LJKWHQWKH
WZRWRSVFUHZVRQHDFKKLQJH5HLQVHUWWKHSODVWLF
SOXJVRQWKHVLGHIURPZKLFKWKHGRRUZDVUHPRYHG
REMOVE THE
BOTTOM SCREW
FROM EACH HINGE
ON THE DRYER FACE
LOOSEN THE TOP SCREWS
FROM EACH HINGE ON
THE DRYER FACE
HALF WAY
MOVE THE DOOR IN AND
DOWN UNTIL THE TOP HINGE
AND THE BOTTOM HINGES ARE
RESTING ON THE TOP SREWS
INSERTED IN STEP 1
SECURE EACH HINGE
AT THE BOTTOM AND
TIGHTEN THE TWO TOP
SCREWS OF EACH HINGE
DUCT
TAPE
CAUTION:
Internal duct joints must besecured with tape,
otherwisethey may separateand causea
safety hazard.
CAUTION:
Internal duct joints must be
secured with tape, otherwise
they may separate and cause
a safety hazard.

Installation Instructions
8
WATER SUPPLY REQUIREMENTS
+RWDQGFROGZDWHUIDXFHWV0867EHLQVWDOOHGZLWKLQ
LQFPRI\RXUZDVKHU·VZDWHULQOHW7KHIDXFHWV
0867EHLQFPJDUGHQKRVHW\SHVRLQOHWKRVHV
FDQEHFRQQHFWHG:DWHUSUHVVXUH0867EHEHWZHHQ
DQGSRXQGVSHUVTXDUHLQFK<RXUZDWHUGHSDUWPHQW
FDQDGYLVH\RXRI\RXUZDWHUSUHVVXUH
NOTE: $ZDWHUVRIWHQHULVUHFRPPHQGHGWRUHGXFH
EXLOGXSRIVFDOHLQVLGHWKHVWHDPJHQHUDWRULIWKHKRPH
ZDWHUVXSSO\LVYHU\KDUG
CONNECTING INLET HOSES
(on some models)
7RSURGXFHVWHDPWKHGU\HUPXVWFRQQHFWWRWKHFROG
ZDWHUVXSSO\6LQFHWKHZDVKHUPXVWDOVRFRQQHFWWRWKH
FROGZDWHUD´<µFRQQHFWRULVLQVHUWHGWRDOORZERWKLQOHW
KRVHVWRPDNHWKDWFRQQHFWLRQDWWKHVDPHWLPH
NOTE:8VHWKHQHZLQOHWKRVHVSURYLGHGQHYHU
XVHROGKRVHV
1.7XUQWKHFROGZDWHUIDXFHWRȺ5HPRYHWKHZDVKHULQOHW
KRVHIURPWKHZDVKHU¿OOYDOYHFRQQHFWRUFROG
2.(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGVFUHZWKH
IHPDOHFRXSOLQJRIWKHVKRUWKRVHRQWRWKHZDVKHU¿OO
YDOYHFRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
3.$WWDFKWKHIHPDOHHQGRIWKH¶·<··FRQQHFWRUWRWKH
PDOHFRXSOLQJRIWKHVKRUWKRVH(QVXUHWKHUXEEHUÀDW
ZDVKHULVLQSODFH7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
4.,QVHUWWKH¿OWHUVFUHHQLQWKHFRXSOLQJRIWKHZDVKHU·V
LQOHWKRVH,IDUXEEHUÀDWZDVKHULVDOUHDG\LQSODFH
UHPRYHLWEHIRUHLQVWDOOLQJWKH¿OWHUVFUHHQ$WWDFKWKLV
FRXSOLQJWRRQHPDOHHQGRIWKH¶·<··FRQQHFWRU7LJKWHQ
E\KDQGXQWLO¿UPO\VHDWHG
5.(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFKWKH
GU\HU·VORQJLQOHWKRVHWRWKHRWKHUPDOHHQGRIWKH¶·<··
FRQQHFWRU7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
6.(QVXUHWKHUXEEHUÀDWZDVKHULVLQSODFHDQGDWWDFK
WKHRWKHUHQGRIWKHGU\HU·VORQJLQOHWKRVHWRWKH¿OO
YDOYHFRQQHFWRUDWWKHERWWRPRIWKHGU\HUEDFNSDQHO
7LJKWHQE\KDQGXQWLO¿UPO\VHDWHG
CONNECTING INLET HOSES (cont.)
7.8VLQJSOLHUVWLJKWHQDOOWKHFRXSOLQJVZLWKDQDGGLWLRQDO
WZR²WKLUGVWXUQ
NOTE:'RQRWRYHUWLJKWHQ'DPDJHWRWKHFRXSOLQJVPD\
UHVXOW
8.7XUQWKHZDWHUIDXFHWRQ
9.&KHFNIRUOHDNVDURXQGWKH¶·<··FRQQHFWRUIDXFHWDQG
KRVHFRXSOLQJV
SERVICING
WARNING LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICING/INSTALLATION.
)RUVHUYLFLQJSKRQHQXPEHUVIRUUHSODFHPHQWSDUWVDQG
RWKHULQIRUPDWLRQUHIHUWR2ZQHU·V0DQXDORUYLVLWRXU
:HEVLWH
5(*,67(5<2851(:$33/,$1&(725(&(,9($1<
,03257$17352'8&7127,),&$7,216
3OHDVHJRWRZZZGEAppliances.comRUPDLOLQ\RXU
3URGXFW5HJLVWUDWLRQ&DUG
)RUTXHVWLRQVRQLQVWDOODWLRQFDOO86RU
&DQDGD
This manual suits for next models
18
Table of contents
Other GE Dryer manuals

GE
GE DBVH512 User manual

GE
GE DDG7986RAL User manual

GE
GE PCVH485EK Original instructions

GE
GE DPGT750ECPL - Profile Harmony 7.3 cu. Ft. Electric... User manual

GE
GE DBB5500 User manual

GE
GE 4500 User manual

GE
GE Profile DPVH880EJ How to use

GE
GE GTDS820ED0WS User manual

GE
GE Appliances DCCB330 Manual

GE
GE GFD65 Original instructions

GE
GE Appliances Profile PFDS450 Operating instructions

GE
GE CleanSpeak GTD81ESSJWS User manual

GE
GE DuraDrum GTDP200GM Manual

GE
GE DBB5000 User manual

GE
GE 450 User manual

GE
GE Profile DPGT750 Operating instructions

GE
GE DBVH520EJ User manual

GE
GE GFDS175 User manual

GE
GE VH Series 2000 User manual

GE
GE GFMN100ELWW User manual